At least 379 records · Page 21

Analysis and Optimization of a Novel Hexagonal Waveguide Concentrator for Solar Thermal Applications

This paper analyzes a novel, cost-effective planar waveguide solar concentrator design that is inspired by cellular hexagonal structures in nature with the benefits of facile installation and low operation and maintenance cost. A coupled thermal and optical analysis of solar irradiation through an ideal hexagonal waveguide concentrator integrated with a linear receiver is presented, along with a cost analysis methodology, to establish the upper limit of performance. The techno-economic model, coupled with numerical optimization, is used to determine designs that maximized power density and minimized the cost of heat in the temperature range of 100–250 °C, which constitutes more than half of the industrial process heat demand. Depending on the incident solar irradiation and the application temperature, the cost of heat for the optimal design configuration ranged between 0.1–0.27 $/W and 0.075–0.18 $/W for waveguide made of ZK7 glass and polycarbonate, respectively. A techno-economic analysis showed the potential of the technology to achieve cost as low as 80 $/m2 and 61 $/m2 for waveguide made of ZK7 glass and polycarbonate material, respectively, which is less than half the cost of state-of-the-art parabolic trough concentrators. Overall, the hexagonal waveguide solar concentrator technology shows immense potential for decarbonizing the industrial process heat and thermal desalination sectors.

14 SOLAR ENERGY↗

Ice nucleating particle concentrations measured by the CSU-CFDC during the AGINSGP field experiment

Real-time, immersion mode ambient ice nucleating particle (INP) concentrations were measured at ARM&rsquo;s Southern Great Plains (SGP) site during the AGINSGP field experiment using a continuous flow diffusion chamber (CFDC) from Colorado State University (CSU). The CSU-CFDC is an ice-thermal gradient diffusion chamber that optically detects the freezing of single aerosol particles (Rogers 1988; Rogers et al. 2001; and Eidhammer et al. 2010). The instrument was located in the guest instrument facility (GIF) and measured INP concentrations from April 8th to April 29th. Air was drawn into the GIF through custom aluminum stack inlets (6&rdquo; inner diameter) attached vertically to the outer GIF wall and the GIF outside platform. A blower pulled air through the stacks at a velocity of 1 m/s. Aerosol instruments subsampled via wall ports, through either 3/8&rdquo; or 1/4" copper lines, depending on sample flow of the instrument. Rogers, D. C., Development of a continuous flow thermal gradient diffusion chamber for ice nucleation studies, Atmospheric Research, 22(2), 149-181, doi:10.1016/0169-8095(88)90005-1, 1988. Rogers, D. C., P. J. DeMott, S. M. Kreidenweis and Y. Chen, A continuous flow diffusion chamber for airborne measurements of ice nuclei, J. Atmos. Oceanic Technol., 18, 725-741, doi:10.1175/1520-0426(2001)018<0725:ACFDCF>2.0.CO;2, 2001. Eidhammer, T., DeMott, P. J., Prenni, A. J., Petters, M. D., Twohy, C. H., Rogers, D. C., Stith, J., Heymsfield, A., Wang, Z., Haimov, S., French, J., Pratt, K., Prather, K., Murphy, S., Seinfeld, J., Subramanian, R., and Kreidenweis, S. M., Ice initiation by aerosol particles: Measured and predicted ice nuclei concentrations versus measured ice crystal concentrations in an orographic wave cloud, J. Atmos. Sci., 67, 2417-2436, doi:10.1175/2010JAS3266.1, 2010

54 ENVIRONMENTAL SCIENCES↗

Electrochemical Impedance Spectroscopy and Cyclic Voltammetry Methods for Monitoring SmCl 3 Concentration in Molten Eutectic LiCl-KCl

Molten salt solutions consisting of eutectic LiCl-KCl and concentrations of samarium chloride (0.5 to 3.0 wt%) at 500 C were analyzed using both cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The CV technique gave the average diffusion coefficient for Sm 3+ over the concentration range. Equipped with Sm 3+ diffusion coefficient, the Randles-Sevcik equation predicted Sm 3+ concentration values that agree with the given experimental values. From CV measurements; the anodic, cathodic, and half-peak potentials were identified and subsequently used as a parameter to acquire EIS spectra. A six-element Voigt model was used to model the EIS data in terms of resistance-time constant pairs. The lowest resistances were observed at the half-peak potential with the associated resistance-time constant pairs characterizing the reversible reaction between Sm 3+ and Sm 2+ . By extrapolation, the Voigt model estimated the polarization resistance and established a polarization resistance-concentration relationship.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Phototrophs in high-iron-concentration microbial mats: physiological ecology of phototrophs in an iron-depositing hot spring

At Chocolate Pots Hot Springs in Yellowstone National Park the source waters have a pH near neutral, contain high concentrations of reduced iron, and lack sulfide. An iron formation that is associated with cyanobacterial mats is actively deposited. The uptake of [(14)C]bicarbonate was used to assess the impact of ferrous iron on photosynthesis in this environment. Photoautotrophy in some of the mats was stimulated by ferrous iron (1.0 mM). Microelectrodes were used to determine the impact of photosynthetic activity on the oxygen content and the pH in the mat and sediment microenvironments. Photosynthesis increased the oxygen concentration to 200% of air saturation levels in the top millimeter of the mats. The oxygen concentration decreased with depth and in the dark. Light-dependent increases in pH were observed. The penetration of light in the mats and in the sediments was determined. Visible radiation was rapidly attenuated in the top 2 mm of the iron-rich mats. Near-infrared radiation penetrated deeper. Iron was totally oxidized in the top few millimeters, but reduced iron was detected at greater depths. By increasing the pH and the oxygen concentration in the surface sediments, the cyanobacteria could potentially increase the rate of iron oxidation in situ. This high-iron-content hot spring provides a suitable model for studying the interactions of microbial photosynthesis and iron deposition and the role of photosynthesis in microbial iron cycling. This model may help clarify the potential role of photosynthesis in the deposition of Precambrian banded iron formations.

NASA Discipline Exobiology↗

Relative reactivity of ribosyl 2'-OH vs. 3'-OH in concentrated aqueous solutions of phosphoimidazolide activated nucleotides

Phosphoimidazolide activated ribomononucleotides (*pN, see structure) are useful substrates for the non-enzymatic synthesis of oligonucleotides. In the presence of metal ions, aqueous solutions of *pN yield primarily the two internucleotide-linked (pN2' pN and pN3' pN) and the pyrophosphate-linked (N5' ppN) dimers. Small amounts of cyclic dimers and higher oligomers are also produced. In this study the relative reactivity of 2'-OH vs. 3'-OH was determined from the ratio of the yields of pN2' pN vs. pN3' pN. Experiments were performed at 23 degrees C in the range 7.2 < or = pH < or = 8.4 with substrates that differ in nucleobase (guanosine (G), cytidine (C), uridine (U), and adenosine (A)) and leaving group (imidazole (Im), 2-methylimidazole (2-MeIm) and 2,4-dimethylimidazole (2,4-diMeIm)). Two metal ions (Mg2+ or Mn2+) were employed as catalysts. The conditions used here, i.e. a substrate concentration in the range 0.1 M to 1.0 M and metal ion concentration in the range 0.05 M to 0.2 M, favor base-stacking interactions. The ratio pN2' pN: pN3' pN = 2'-5': 3'-5' was found independent of nucleobase and typically varied between 2 to 3 indicating that the 2'-OH is about 2 to 3 times more reactive than the 3'-OH. *pN with Im, compared to 2-MeIm and 2,4-diMeIm leaving group, produce lower yields of internucleotide linked dimers, and a higher pN2' pN: pN3' pN ratio. Trends in the data, observed with all three leaving groups, suggest an increase in pN2' pN: pN3' pN ratio with decreasing substrate concentration (up to 5.47 with 0.051 M ImpG). The observations are in accord with earlier studies reporting a relative reactivity 2'-5': 3'-5' = 6 to 9 obtained with Im as the leaving group, in dilute nucleotide solutions and under conditions that disfavor stacking. It is speculated that the concentration induced change in the relative reactivity is the result of self-association via base-stacking that enhances selectively the proximity of the 3'-OH of one molecule to the reactive P-N bond of an other molecule. The implication of these conclusions for oligomerization/ligation reactions is discussed.

NASA Discipline Exobiology↗

A New Method to Correct the Electrochemical Concentration Cell (ECC) Ozonesonde Time Response and its Implications for "Background Current" and Pump Efficiency

The electrochemical concentration cell (ECC) ozonesonde has been the main instrument for in situ profiling of ozone worldwide; yet, some details of its operation, which contribute to the ozone uncertainty budget, are not well understood. Here, we investigate the time response of the chemical reactions inside the ECC and how corrections can be used to remove some systematic biases. The analysis is based on the understanding that two reaction pathways involving ozone occur inside the ECC that generate electrical currents on two very different timescales. The main fast-reaction pathway with a time constant of about 20 s is due the conversion of iodide to molecular iodine and the generation of two free electrons per ozone molecule. A secondary slow-reaction pathway involving the buffer generates an excess current of about 2 %–10 % with a time constant of about 25 min. This excess current can be interpreted as what has conventionally been considered the “background current”. This contribution can be calculated and removed from the measured current instead of the background current. Here we provide an algorithm to calculate and remove the contribution of the slow-reaction pathway and to correct for the time lag of the fast-reaction pathway. This processing algorithm has been applied to ozonesonde profiles at Costa Rica and during the Central Equatorial Pacific Experiment (CEPEX) as well as to laboratory experiments evaluating the performance of ECC ozonesondes. At Costa Rica, where a 1 % KI, 1/10th buffer solution is used, there is no change in the derived total ozone column; however, in the upper troposphere and lower stratosphere, average reported ozone concentrations increase by up to 7 % and above 30 km decrease by up to 7 %. During CEPEX, where a 1 % KI, full-buffer solution was used, ozone concentrations are increased mostly in the upper troposphere, with no change near the top of the profile. In the laboratory measurements, the processing algorithms have been applied to measurements using the majority of current sensing solutions and using only the stronger pump efficiency correction reported by Johnson et al. (2002). This improves the accuracy of the ECC sonde ozone profiles, especially for low ozone concentrations or large ozone gradients and removes systematic biases relative to the reference instruments. In the surface layer, operational procedures prior to launch, in particular the use of filters, influence how typical gradients above the surface are detected. The correction algorithm may report gradients that are steeper than originally reported, but their uncertainty is strongly influenced by the prelaunch procedures.

electrochemical concentration cell (ECC) ozonesond↗

Dilution of Boundary Layer Cloud Condensation Nucleus Concentrations by Free Tropospheric Entrainment During Marine Cold Air Outbreaks

Recent aircraft measurements over the northwest Atlantic enable an investigation of how entrainment from the free troposphere (FT) impacts cloud condensation nucleus (CCN) concentrations in the marine boundary layer (MBL) during cold-air outbreaks (CAOs), motivated by the role of CCN in mediating transitions from closed to open-cell regimes. Observations compiled over eight flights indicate predominantly far lesser CCN concentrations in the FT than in the MBL. For one flight, a fetch-dependent MBL-mean CCN budget is compiled from estimates of sea-surface fluxes, entrainment of FT air, and hydrometeor collision-coalescence, based on in-situ and remote-sensing measurements. Results indicate a dominant role of FT entrainment in reducing MBL CCN concentrations, consistent with satellite-observed trends in droplet number concentration upwind of CAO cloud-regime transitions over the northwest Atlantic. Relatively scant CCN may widely be associated with FT dry intrusions, and should accelerate cloud-regime transitions where underlying MBL air is CCN-rich, thereby reducing regional albedo.

Boundary Layer Cloud Condensation Nucleus Concentr↗

Ground Testing of an Oxygen Concentrator in a Simulated International Space Station (ISS) Cabin Environment

The method for supplying medical oxygen to respiratorily-compromised astronauts on the International Space Station (ISS) and in future Orion missions consists of drawing oxygen from high pressure oxygen tanks. An Oxygen Concentrator Module (OCM) is a device that pulls in ambient air and separates out the nitrogen, resulting in a high concentration oxygen source. This technology has the potential to eliminate resupply and oxygen-enrichment issues associated with using high pressure oxygen tanks and become an alternative technology to support medical oxygen operations for future exploration missions. In this study, we test the long-term performance of a Commercial Off-the-Shelf (COTS) OCM in a simulated ISS cabin environment. Humidified air, carbon dioxide, and fifteen representative trace contaminants are continuously injected through a enclosed test chamber where the OCM is challenged. This study included the first successful demonstration of the Trace Gas Injection System (TGIS), which reliably and continuously produced ISS levels of trace contaminants, carbon dioxide, and humidity in an enclosed environment. The TGIS is a new and unique ground capability with significant implications for Test Readiness Level (TRL) advancement of COTS items and Government Furnished Equipment (GFE). This study demonstrated that the tested OCM reliably delivers enriched oxygen mostly at desired performance specifications. This study also demonstrated that the OCM does not inadvertently concentrate trace gases in its oxygen product stream, as detectable concentrations of trace contaminants in the oxygen product stream were at all times below the simulated ISS levels.

medical oxygen↗

Ground Testing of an Oxygen Concentrator in a Simulated International Space Station (ISS) Cabin Environment

The method for supplying medical oxygen to respiratorily-compromised astronauts on the International Space Station (ISS) and in future Orion missions consists of drawing oxygen from high pressure oxygen tanks. An Oxygen Concentrator Module (OCM) is a device that pulls in ambient air and separates out the nitrogen, resulting in a high concentration oxygen source. This technology has the potential to eliminate resupply and oxygen-enrichment issues associated with using high pressure oxygen tanks and become an alternative technology to support medical oxygen operations for future exploration missions. In this study, we test the long-term performance of a Commercial Off-the-Shelf (COTS) OCM in a simulated ISS cabin environment. Humidified air, carbon dioxide, and fifteen representative trace contaminants are continuously injected through an enclosed test chamber where the OCM is challenged. This study included the first successful demonstration of the Trace Gas Injection System (TGIS), which reliably and continuously produced ISS levels of trace contaminants, carbon dioxide, and humidity in an enclosed environment. The TGIS is a new and unique ground capability with significant implications for Test Readiness Level (TRL) advancement of COTS items and Government Furnished Equipment (GFE). This study demonstrated that the tested OCM reliably delivers enriched oxygen mostly at desired performance specifications. This study also demonstrated that the OCM does not inadvertently concentrate trace gases in its oxygen product stream, as detectable concentrations of trace contaminants in the oxygen product stream were at all times below the simulated ISS levels.

medical oxygen↗

VENTSAR V3.0: A Python GUI for Estimating Contaminant Concentrations on or Near Buildings Due to Building Effects and Plume Rise and For Calculating Inhalation and Plume Shine Doses

VENTSAR: Originated as VENTAX (Smith and Weber 1983) on the IBM Mainframe at the Savannah River Site (SRS) as a Fortran program. Updated to VENTSAR XL V1.0 (Simpkins 1997) as a spreadsheet version using macros created in Microsoft Excel. Later updated to VENTSAR XL V2.0 (Dixon 2018) as a spreadsheet executing a modified version of the original VENTAX Fortran code. Estimates contaminant concentrations on or near a building from a release at a nearby location. Calculates concentrations for a given meteorological exceedance probability or for a given stability and wind speed combination. Can model a single building with or without a penthouse on top or a ground location from either a stack or ground release. Plume rise can be considered. Contaminant releases can be chemical or radioactive with downwind concentrations determined at user-specified distances. Wind passing over and around buildings creates a complicated dispersion pattern. Air-intake vents may be located on building roofs or near the ground downwind of a release source. An estimation of pollutant concentrations on or near a structure is important in determining expected pollutant levels. Meteorological data are selected based on a specific area of the site. Fortran-based VENTAX able to make fast, complex mathematical calculations. Not user-friendly VENTSAR XL V1.0 no longer supported due to obsolete Excel macros. VENTSAR XL V2.0 an interim solution using an Excel spreadsheet to interface with the modified VENTAX Fortran code. Requires user to have Microsoft Excel. Not an intuitive interface for someone unfamiliar with VENTSAR. Does not perform dose calculations. VENTSAR V3.0 goal to combine the strengths of previous versions of VENTSAR into a single, powerful yet user-friendly program with a Graphical User Interface (GUI). Not dependent upon a specific program or plug-ins. Self-contained package to be used on any computer running Microsoft Windows. User-friendly, intuitive GUI created in Python for parameter input. Executes same modified VENTAX Fortran code as VENTSAR XL V2.0. Outputs formatted text file of completed calculations for easy review and dissemination. Performs inhalation and plume shine dose calculations for up to 11 user-selected nuclides from a nuclide dose factor library of almost 500 nuclides. 12 test cases were created for verification of V1.0 and V2.0. Same test cases run in V3.0 to verify correct performance. V3.0 produced similar results to V1.0. Confirmed GUI did not alter calculations in any way. Comparisons of the test case results confirm the V3.0 GUI does not influence the VENTSAR calculations. Simply passes same input parameters to VENTAX Fortran code for execution. Provides end user an easy-to-use, intuitive tool to quickly make building effect and plume rise calculations, as well as, inhalation and plume shine dose calculations. No experience with or working knowledge of Fortran, Excel, command line, or macros required. Self-contained package allows VENTSAR be deployed to any Windows computer without the need for specific programs or plug-ins.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Low Level Radon Concentration and Radon Daughter Dose Monitoring in an Arid-zone Waste Store - 20081

Radioactive waste containing predominantly soil and rubble from the clean-up of a former uranium and thorium minerals processing research facility is currently stored at the Woomera Test Range in South Australia awaiting final disposal. Prior to commencing any manipulation of the nearly 10,000 waste drums (205 L or 55 gallon each), radon concentration monitoring and radon daughter dosimetry has been undertaken to (i) gain understanding of the temporal and spatial variation of radon and its daughters within the storage facility, which could provide insights into the radiological source term and (ii) confirm that radiological risks to workers are below the guideline values. A time series of nearly 12 months of detailed observations shows low level radon concentrations with annual average values that are slightly above the average radon concentrations in Australian homes. Peak values in summer are about three times higher than the annual average based on the CRM measurements. Both radon concentrations and annual effective dose are well below the regulatory limits. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Meteorological Conditions and Atmospheric Components Concentration in Urban Sites in Knoxville, USA. 2024

This dataset, which contains five csv files, reports several meteorological conditions such as temperature, wind speed, solar radiation, and net radiation measured in Cumberland Estates Park (CEP) and Socially Equal Energy Efficient Development (SEEED) sites in Knoxville, Tennessee, USA. Also, hourly concentration of particulate matter (PM) with different aerodynamic diameter and inorganic gases such as ozone and nitrogen dioxide measured in the two are included in this dataset. The concentrations of PM and inorganic gases were monitored using the MODULAIR, a low-cost sensor equipped with a solar power module. The measurement of the concentration of biogenic and anthropogenic volatile organic compounds (VOCs) of the two sites was determined using a High-Resolution Proton Transfer Reaction Time of Flight Mass Spectrometer (PTR-ToF-MS). The VOCs were collected using miniature canister (400 mL) equipped with female RAVEqc valve to 1/4” male compression fitting and an integrated passive air sampling kit. This work is a part of a larger study which investigates the impact of soil moisture and plant evapotranspiration on ambient temperature and relative humidity in several city parks in Knoxville, Tennessee.

54 ENVIRONMENTAL SCIENCES↗

Concentration‐dependent Cycling of Phenothiazine‐based Electrolytes in Nonaqueous Redox Flow Cells

Increasing redox-active species concentrations can improve viability for organic redox flow batteries by enabling higher energy densities, but the required concentrated solutions can become viscous and less conductive, leading to inefficient electrochemical cycling and low material utilization at higher current densities. To better understand these tradeoffs in a model system, we study a highly soluble and stable redox-active couple, N-(2-(2-methoxyethoxy)ethyl)phenothiazine (MEEPT), and its bis(trifluoromethanesulfonyl)imide radical cation salt (MEEPT-TFSI). We measure the physicochemical properties of electrolytes containing 0.2–1 M active species and connect these to symmetric cell cycling behavior, achieving robust cycling performance. Specifically, for a 1 M electrolyte concentration, we demonstrate 94% materials utilization, 89% capacity retention, and 99.8% average coulombic efficiency over 435 h (100 full cycles). This demonstration helps to establish potential for high-performing, concentrated nonaqueous electrolytes and highlights possible failure modes in such systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Impact of gel concentration on filter fluxes in microfiltration of Hanford tank wastes and simulants

Abstract Treatment processes have been proposed that will utilize crossflow filtration to concentrate sludge waste streams at the Department of Energy's Hanford Site. Challenges associated with solid–liquid separation of the waste streams drive a necessary evaluation of available Hanford high level waste (HLW) filtration data. Limiting flux conditions during crossflow filtration are elucidated with the formation of a cake layer on the membrane surface. A mass transfer coefficient between the gel and bulk concentrations plays a critical role in determining filter flux. A correlation between the gel concentration and mass transfer coefficient is made to assist in determining filter performance of select HLW streams. As a process alternative to crossflow filtration, gravity settling of waste streams may be deployed as a solid–liquid separation technique. However, this results in a contrasting performance with the centrifuged solids concentration. A method was developed to estimate expected filtration and settling performance based on physical characterization data for Hanford tank waste samples. By assessing the estimated processing performance of HLW, technical support can be provided during flowsheet planning.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Integrating Mercury Concentrations in American Alligators ( Alligator mississippiensis ) with Hunter Consumption Surveys to Estimate Exposure Risk

Mercury is a naturally occurring element but is also considered a widespread contaminant due to global anthropogenic activity. Even in moderate amounts, mercury (Hg) is an established neurotoxin and is associated with a range of adverse outcomes both in humans and wildlife. Humans in the United States are most commonly exposed to Hg through contaminated food or drinking water, and the consumption of game species, particularly those occupying higher trophic levels, has the potential to expose hunters to high concentrations of Hg. In the present study, we determined Hg concentrations in tail muscle and blood from American alligators (Alligator mississippiensis) inhabiting a region (Savannah River Site, SC, USA) with known Hg contamination. We then integrated these data with alligator harvest records and previously published surveys of alligator meat consumption patterns to estimate potential exposure risk. We found that the average Hg concentrations in tail muscle (1.34 mg/kg, wet wt) from sampled alligators exceeded the recommended threshold for Hg exposure based on the World Health Organization's guidelines (0.5mg/kg, wet wt). In addition, based on regional consumption patterns reported for both adults and children, we estimated Hg exposures (x¯ Adult = 0.419 μg/kg/day, x¯ Child = 2.24 μg/kg/day) occurring well above the US Environmental Protection Agency methylmercury reference dose of 0.1 μg/kg/day. Although the two reservoirs sampled in the present study are not currently open to alligator hunting, they are connected to waters that are publicly accessible, and the extent of alligator mobility across these sites is not known. Together, the findings reported in the present study further demonstrate the need for active monitoring of Hg concentrations in game species, which can convey substantial exposure risks to the public.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Molar Absorptivities of U(VI), U(IV), and Pu(III) in Nitric Acid Solutions of Various Concentrations Relevant to Developing Nuclear Fuel Recycling Flowsheets

Testing of a co-decontamination (CoDCon) tributyl phosphate (TBP) based solvent extraction flowsheet is being performed to optimize conditions for achieving a target U/Pu ratio in the Pu-containing product. The flowsheet is designed to directly produce a mixture of U and Pu with a U/Pu mass ratio of 7/3. The system is monitored in real time using optical spectroscopy, which allows for control of the U/Pu ratio in the aqueous U/Pu nitrate product. On-line spectrophotometric monitoring of the aqueous stream at the reductive stripping step involves determination of U(VI), U(IV) and Pu(III) concentrations and relies on molar absorptivities of these species in nitric acid at a number of wavelengths corresponding to their peaks’ maxima. The magnitudes of these molar absorptivities are a sensitive function of nitric acid concentration and have to be determined as precisely as possible using an off-line spectrophotometry under well controlled conditions. This step (called training set acquisition) is typically performed not in a high contamination area of radiological glovebox where flow-through cells and other on-line equipment are installed but in a less aggressive environment of a radiological fume hood with much better control of stock solutions quality, dilution factors, optical absorbance scale calibration, etc. This is followed by the calibration transfer between the off-line instrument and the instrument deployed during extraction and stripping runs. This paper reports values of molar absorptivities of U(VI), U(IV), and Pu(III) in nitric acid solution of 0.5 M to 4 M concentration and compares them with available technical literature data. Results of off-line spectrophotometric analysis of selected aqueous grab samples from one of CoDCon runs show satisfactory agreement with total uranium and plutonium concentrations determined in the same samples by ICP-MS.

Sinkov, Sergey I.↗

Variation of the Passive Film on Compositionally Concentrated Dual-Phase Al 0.3 Cr 0.5 Fe 2 Mn 0.25 Mo 0.15 Ni 1.5 Ti 0.3 and Implications for Corrosion

The passive film on a dual-phase Al 0.3 Cr 0.5 Fe 2 Mn 0.25 Mo 0.15 Ni 1.5 Ti 0.3 FCC + Heusler (L2 1 ) compositionally concentrated alloy formed during extended exposure to an applied potential in the passive range in dilute chloride solution was characterized. Each phase, with its own distinct composition of passivating elements, formed unique passive films separated by a heterophase interface. High-resolution, surface sensitive characterization enabled chemical analysis of the passive film formed over individual phases. The film formed over the L2 1 phase had a higher concentration of Al, Ni, and Ti, while the film formed over FCC phase was of similar thickness but contained comparatively higher Cr, Fe, and Mo concentrations, consistent with the differences in bulk microstructure composition. The passive film was continuous across phase boundaries and the distribution of passivating elements (Al, Cr, and Ti) indicated both phases were independently passivated. Spatially resolved analysis of the surface chemistry of the dual-phase CCA revealed that the cation with the highest composition in passive film formed on the FCC phase was Cr (52.4 at. pct) and for the L2 1 phase was Ti (53.1 at. pct) despite the bulk concentration of each element being below 20 at. pct in their respective phases. Al, Cr, and Ti were enriched in both phases within the passive film relative to their respective bulk compositions. In parallel studies, single-phase alloys with compositions representative of the FCC and L2 1 phases were synthesized to evaluate the corrosion behavior of each phase in isolation. The corrosion behavior of the dual-phase alloy showed passivity evidenced by a pitting potential of 0.615 V SCE in 0.01 M NaCl. The pitting potential and other electrochemical parameters suggested a combination of behaviors of both single-phase samples, suggesting that the global corrosion behavior may be represented by a composite theory applied to phases, their area fractions, and interphase length. However, the interphase in the dual-phase CCA was a local corrosion initiation site and may limit localized corrosion protectiveness. The alloy design implications for optimization of second phase structure and morphology are discussed.

36 MATERIALS SCIENCE↗

Change of Electrical and Transport Properties of Nickel Oxide by Carrier Concentration and Temperature through First-Principle Calculations

Abstract Nickel is typically used as one of the main components in electrical contact devices or connectors. Nickel oxide (NiO) is usually formed on the surfaces of electrodes and can negatively impact system performance by introducing electrical contact resistance. The thermal, electrical, and transport properties of NiO, as a Mott insulator or a p-type semiconductor, can be altered by operating and environmental conditions such as temperature and stress/strain by contact. In this study, we investigate the fundamental material properties of NiO through the first-principle calculations. First, we obtain and compare the lattice parameter, magnetic moment, and electronic structure for NiO via the WIEN2K simulations with four different potentials (i.e., GGA, GGA + U, LSDA, and LSDA + U). Then, using the WIEN2K simulation results with LSDA + U potential that produces a highly accurate bandgap for NiO, we calculate the electrical conductivity and electrical part of the thermal conductivity of nickel and NiO as a function of temperature and carrier concentration through the BoltzTraP simulations. Systematic simulation results revealed that the electrical conductivity relative to the relaxation time for NiO increases with the carrier concentration, while it shows a slightly decreasing trend with temperature under a fixed carrier concentration. By contrast, the electrical part of the thermal conductivity shows an increasing trend considering carrier concentration and temperature.

Shah, Nayem Md. Reza↗