Search NASA⌕ Search

SEARCH · Search NASA

Results for “COUNTING RATES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Degradation of Commercial Lithium-Ion Cells as a Function of Chemistry and Cycling Conditions

Energy storage systems with Li-ion batteries are increasingly deployed to maintain a robust and resilient grid and facilitate the integration of renewable energy resources. However, appropriate selection of cells for different applications is difficult due to limited public data comparing the most commonly used off-the-shelf Li-ion chemistries under the same operating conditions. This article details a multi-year cycling study of commercial LiFePO 4 (LFP), LiNi x Co y Al 1–x–y O 2 (NCA), and LiNi x Mn y Co 1–x–y O 2 (NMC) cells, varying the discharge rate, depth of discharge (DOD), and environment temperature. The capacity and discharge energy retention, as well as the round-trip efficiency, were compared. Even when operated within manufacturer specifications, the range of cycling conditions had a profound effect on cell degradation, with time to reach 80% capacity varying by thousands of hours and cycle counts among cells of each chemistry. The degradation of cells in this study was compared to that of similar cells in previous studies to identify universal trends and to provide a standard deviation for performance. All cycling files have been made publicly available at batteryarchive.org, a recently developed repository for visualization and comparison of battery data, to facilitate future experimental and modeling efforts.

25 ENERGY STORAGE↗

Valorisation of Wasted Immature Tomato to Innovative Fermented Functional Foods

In this study, the lactic fermentation of immature tomatoes as a tool for food ingredient production was evaluated as a circular economy-oriented alternative for valorising industrial tomatoes that are unsuitable for processing and which have wasted away in large quantities in the field. Two lactic acid bacteria (LAB) were assessed as starter cultures in an immature tomato pulp fermentation to produce functional food ingredients with probiotic potential. The first trial evaluated the probiotic character of Lactiplantibacillus plantarum (LAB97, isolated from immature tomato microbiota) and Weissella paramesenteroides (C1090, from the INIAV collection) through in vitro gastrointestinal digestion simulation. The results showed that LAB97 and C1090 met the probiotic potential viability criterion by maintaining 6 log10 CFU/mL counts after in vitro simulation. The second trial assessed the LAB starters’ fermentative ability. Partially decontaminated (110 °C/2 min) immature tomato pulp was used to prepare the individually inoculated samples (Id: LAB97 and C1090). Non-inoculated samples, both with and without thermal treatment (Id: CTR-TT and CTR-NTT, respectively), were prepared as the controls. Fermentation was undertaken (25 °C, 100 rpm) for 14 days. Throughout storage (0, 24, 48, 72 h, 7, and 14 days), all the samples were tested for LAB and Y&M counts, titratable acidity (TA), solid soluble content (SSC), total phenolic content (TPC), antioxidant capacity (AOx), as well as for organic acids and phenolic profiles, and CIELab colour and sensory evaluation (14th day). The LAB growth reached ca. 9 log10 CFU/mL for all samples after 72 h. The LAB97 samples had an earlier and higher acidification rate than the remaining ones, and they were highly correlated to lactic acid increments. The inoculated samples showed a faster and higher decrease rate in their SSC levels when compared to the controls. A nearly two-fold increase (p < 0.05) during the fermentation, over time, was observed in all samples’ AOx and TPC (p < 0.05, r = 0.93; similar pattern). The LAB97 samples obtained the best sensory acceptance for flavour and overall appreciation scores when compared to the others. In conclusion, the L. plantarum LAB97 starter culture was selected as a novel probiotic candidate to obtain a potential probiotic ingredient from immature tomato fruits.

Pereira, Nelson (ORCID:0000000345745615)↗

Strategies for on-chip digital data compression for X-ray pixel detectors

Here, the continued desire for X-ray pixel detectors with higher frame rates will stress the ability of application-specific integrated circuit (ASIC) designers to provide sufficient off-chip bandwidth to reach continuous frame rates in the 1 MHz regime. To move from the current 10 kHz to the 1 MHz frame rate regime, ASIC designers will continue to pack as many power-hungry high-speed transceivers at the periphery of the ASIC as possible. In this paper, however, we present new strategies to make the most efficient use of the off-chip bandwidth by utilizing data compression schemes for X-ray photon-counting and charge-integrating pixel detectors. In particular, we describe a novel in-pixel compression scheme that converts from analog to digital converter units to encoded photon counts near the photon Poisson noise level and achieves a compression ratio of >1.5x independent of the dataset. In addition, we describe a simple yet efficient zero-suppression compression scheme called "zeromask" (ZM) located at the ASIC's edge before streaming data off the ASIC chip. ZM achieves average compression ratios of >4x, >7x, and >8x for high-energy X-ray diffraction, ptychography, and X-ray photon correlation spectroscopy datasets, respectively. We present the conceptual designs, register-transfer level block diagrams, and the physical ASIC implementation of these compression schemes in 65 nm CMOS. When combined, these two digital compression schemes could increase the effective off-chip bandwidth by a factor of 6-12x.

47 OTHER INSTRUMENTATION↗

Fill and dump measurement of the neutron lifetime using an asymmetric magneto-gravitational trap

The past two decades have yielded several new measurements and reanalysis of older measurements of the neutron lifetime. These have led to a 4.4 standard deviation discrepancy between the most precise measurements of the neutron decay rate producing protons in cold neutron beams and the most precise lifetime measured in neutron storage experiments. Measurements using different techniques are important for investigating whether there are unidentified systematic effects in any of the measurements. In this paper we report a new measurement using the Los Alamos asymmetric magnetogravitational trap where the surviving neutrons are counted external to the trap using the fill and dump method. The new measurement gives a free neutron lifetime of $τ_n$ = 876.3(2.4) stat (0.8) syst . Although this measurement is not as precise, it is in statistical agreement with previous results using in situ counting in the same apparatus.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Impact of intense sanitization procedures on bacterial communities recovered from floor drains in pork processing plants

Pork processing plants in the United States (US) cease operations for 24–48 h every six or twelve months to perform intense sanitization (IS) using fogging, foaming, and further antimicrobial treatments to disrupt natural biofilms that may harbor pathogens and spoilage organisms. The impact such treatments have on short-term changes in environmental microorganisms is not well understood, nor is the rate at which bacterial communities return. Swab samples were collected from floor drains to provide representative environmental microorganisms at two US pork processing plants before, during, and after an IS procedure. Samples were collected from four coolers where finished carcasses were chilled and from four locations near cutting tables. Each sample was characterized by total mesophile count (TMC), total psychrophile count (TPC), and other indicator bacteria; their biofilm-forming ability, tolerance of the formed biofilm to a quaternary ammonium compound (300 ppm, QAC), and ability to protect co-inoculated Salmonella enterica. In addition, bacterial community composition was determined using shotgun metagenomic sequencing. IS procedures disrupted bacteria present but to different extents depending on the plant and the area of the plant. IS reduced TPC and TMC, by up to 1.5 Log 10 CFU only to return to pre-IS levels within 2–3 days. The impact of IS on microorganisms in coolers was varied, with reductions of 2–4 Log 10 , and required 2 to 4 weeks to return to pre-IS levels. The results near fabrication lines were mixed, with little to no significant changes at one plant, while at the other, two processing lines showed 4 to 6 Log 10 reductions. Resistance to QAC and the protection of Salmonella by the biofilms varied between plants and between areas of the plants as well. Community profiling of bacteria at the genus level showed that IS reduced species diversity and the disruption led to new community compositions that in some cases did not return to the pre-IS state even after 15 to 16 weeks. The results found here reveal the impact of using IS to disrupt the presence of pathogen or spoilage microorganisms in US pork processing facilities may not have the intended effect.

59 BASIC BIOLOGICAL SCIENCES↗

First experimental determination of the ⁴⁰Ar(𝑛, 2𝑛)³⁹Ar reaction cross section and ³⁹Ar production in Earth’s atmosphere

The cosmogenic ³⁹Ar(t1∕2 = 268 years) isotope of argon is used for geophysical dating and tracing of underground and ocean water, as well as ice owing to its appropriate half-life and chemical inertness as a noble gas; ³⁹Ar serves also in nuclear weapon test monitoring. We measured for the first time the total cross section of the main ³⁹Ar cosmogenic production reaction in the atmosphere, namely ⁴⁰Ar(𝑛, 2𝑛)39 Ar, using 14.8 ± 0.3 MeV neutrons. The neutrons, produced by a deuterium-tritium generator, impinged on a stainless steel sphere filled with Ar gas highly enriched in the ⁴⁰Ar isotope and were monitored by a stack of fast-neutron activation foils. The reaction yield was measured by atom counting of long-lived ³⁹Ar with noble gas accelerator mass spectrometry and, independently, by decay counting relative to atmospheric argon (³⁹Ar/Ar= 8.12 × 10−16 ). A total ⁴⁰Ar(𝑛, 2𝑛)39 Ar cross section of 610 ± 100 mb was determined at 14.8 ± 0.3 MeV incident neutron energy. This result serves as a benchmark for recent theoretical calculations and evaluations, found to reproduce well the experimental total cross section. We use these energy-dependent theoretical cross sections together with experimental spectra of cosmogenic neutrons at different altitudes to calculate the global average rate of neutron-induced ³⁹Ar atmospheric production, resulting in 770 ± 240 39 Ar atoms/cm²/day. The secular equilibrium between the ³⁹Ar calculated production rate and radioactive decay rate leads to a partial isotopic abundance ³⁹Ar/Ar = (5.9 ± 1.8) × 10−16 , showing that ≈73% of atmospheric ³⁹Ar is produced by cosmogenic neutrons, the remaining part believed to be induced by muons and high-energy 𝛾 rays. The ⁴⁰Ar(𝑛, 2𝑛)³⁹Ar cross section at 14 MeV is also a key parameter for quantifying the anthropogenic contribution to atmospheric 39 Ar produced during the thermonuclear tests of the 1960s. We estimate that anthropogenic ³⁹Ar accounts for roughly 20% of the present atmospheric inventory.

39 Ar atmospheric production↗

Toward an AI-Powered Software Pipeline for Real-Time Tracking and Analysis of Wildfire and Smoke

Real-time tracking of wildfires and smoke is crucial for effective response, minimizing damage, protecting lives, and efficiently managing resources during fire emergencies. We develop a web-based AI-powered pipeline that detects wildfires in aerial video and estimates deployment-relevant behavior metrics, including cumulative burned area, burned-area growth rate, fire spread direction, and smoke dispersion. The system combines a YOLO-based detector with YCbCr-based fire segmentation, HSV-based smoke segmentation, Farneback optical flow, and centroid-based spatiotemporal tracking. Using ground sampling distance (GSD), pixel-level fire masks are converted to physical burned-area measurements by correlating fire pixel counts with camera altitude and tilt angle. We benchmark YOLO variants and non-YOLO baselines (GoogLeNet, CNN, DBN, Autoencoder, U-Net, and AlexNet) on the IEEE FLAME dataset and a newly created aerial frame dataset, Wildfire-DB. Cross-dataset evaluation uses a strict threshold-transfer protocol: decision thresholds are selected on FLAME validation and transferred unchanged to Wildfire-DB to quantify generalization under domain shift. YOLOv6 achieves the strongest cross-dataset frame-level fire detection on Wildfire-DB (ROC-AUC 0.8200, PR-AUC 0.8044, and transferred-threshold F1 0.7596). For tracking-oriented deployment requiring oriented localization, YOLO11-OBB provides the most reliable cross-dataset behavior among OBB-capable models while remaining computationally feasible. To analyze the feasibility of UAV deployment, we further measure inference efficiency using synchronized GPU and CPU power logs on a fixed workload of 1569 frames. YOLO-family models process the video in 5.73–12.47 seconds with net energy of 1247.28–1775.39 J, substantially lower latency and energy than heavier classification and reconstruction baselines. Overall, model optimality depends on operational objectives: YOLOv6 is best for cross-dataset detection robustness, whereas YOL...

Color segmentation↗

Poisson Log-Normal Process for Count Data Prediction

Modeling count data is important in physics and other scientific disciplines, where measurements often involve discrete, non-negative quantities such as photon or neutrino detection events. Traditional parametric approaches can be trained to generate integer-count predictions but may struggle with capturing complex, non-linear dependencies often observed in the data. Gaussian process (GP) regression provides a robust non-parametric alternative to modeling continuous data; however, it cannot generate integer outputs. We propose the Poisson Log-Normal (PoLoN) process, a framework that employs GP to model Poisson log-rates. As in GP regression, our approach relies on the correlations between data points captured via GP kernel structure rather than explicit functional parameterizations. We demonstrate that the PoLoN predictive distribution is Poisson-LogNormal and provide an algorithm for optimizing kernel hyperparameters. Furthermore, we adapt the PoLoN approach to the problem of detecting weak localized signals superimposed on a smoothly varying background - a task of considerable interest in many areas of science and engineering. Our framework allows us to predict the strength, location and width of the detected signals. We evaluate PoLoN's performance using both synthetic and real-world datasets, including the open dataset from CERN which was used to detect the Higgs boson at the Large Hadron Collider. Our results indicate that the PoLoN process can be used as a non-parametric alternative for analyzing, predicting, and extracting signals from integer-valued data.

Saha, Anushka [Rutgers U., Piscataway]↗

Fill and dump measurement of the neutron lifetime using an asymmetric magneto-gravitational trap

The past two decades have yielded several new measurements and reanalysis of older measurements of the neutron lifetime. These have led to a 4.4 standard deviation discrepancy between the most precise measurements of the neutron decay rate producing protons in cold neutron beams and the most precise lifetime measured in neutron storage experiments. Measurements using different techniques are important for investigating whether there are unidentified systematic effects in any of the measurements. In this paper we report a new measurement using the Los Alamos asymmetric magneto-gravitational trap where the surviving neutrons are counted external to the trap using the fill and dump method. In this work, the new measurement gives a free neutron lifetime of $τ_n$ = 876.3(2.4) stat (0.8) syst . Although this measurement is not as precise, it is in statistical agreement with previous results using in situ counting in the same apparatus.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Advanced Mixing Condensation Particle Counter (aMCPC) Instrument Handbook

The U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility’s aerosol counting, composition, extinction, and sizing system (ACCESS) includes a base module (9400), a filter sampler (9401), an advanced mixing condensation particle counter (aMCPC, 9403), a miniaturized optical practical counter (MOPC, 9405), and a single-channel tricolor absorption photometer (STAP, 9406). This handbook focuses on the aMCPC, which measures the ultra-fast total aerosol particle number concentration at 180 ms response rate with a detection diameter (D 50 = 7 nm).

54 ENVIRONMENTAL SCIENCES↗

Analysis of Three Types of Collocated Disdrometer Measurements at the ARM Southern Great Plains Observatory

To better provide U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facility’s disdrometer deployment strategy and support ARM precipitation-related projects, this study analyzes 18 months of drop size distribution (DSD) observations from six collocated disdrometers deployed at the ARM Southern Great Plains (SGP) site. Emphasis is placed on quantifying the uncertainties related to DSD and rainfall properties using different types of disdrometers and different pairing concepts. The instrument sampling errors are also discussed, which improves our understanding of instrument-specific impacts on rainfall measurements. The key findings are as follows: 1) All the disdrometers show consistent behaviors overall regarding accumulated precipitation, mean rainfall rate, DSD parameters, and radar reflectivity values; and 2) Strong agreement is shown between three disdrometer types in terms of their DSDs for mid-size drop range (D = 1 mm-4 mm). The two-dimensional video disdrometer performance meets expectations as the most accurate unit among all. The paired disdrometer shows a reduced statistical sampling error in terms of drop counts and other DSD properties. A concept of deploying two or more collocated disdrometers side by side is recommended for future ARM field campaigns.

54 ENVIRONMENTAL SCIENCES↗

Stimulated Emission of Signal Photons from Dark Matter Waves

The manipulation of quantum states of light has resulted in significant advancements in both dark matter searches and gravitational wave detectors. Current dark matter searches operating in the microwave frequency range use nearly quantum-limited amplifiers. Future high frequency searches will use photon counting techniques to evade the standard quantum limit. We present a signal enhancement technique that utilizes a superconducting qubit to prepare a superconducting microwave cavity in a nonclassical Fock state and stimulate the emission of a photon from a dark matter wave. By initializing the cavity in an | n = 4 ⟩ Fock state, we demonstrate a quantum enhancement technique that increases the signal photon rate and hence also the dark matter scan rate each by a factor of 2.78. Using this technique, we conduct a dark photon search in a band around 5.965 GHz ( 24.67 μ eV ), where the kinetic mixing angle ε ≥ 4.35 × 10 − 13 is excluded at the 90% confidence level. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Extinction Monitoring of Pulsed Proton Beams Using FPGA-Based Peak Detection

The Mu2e experiment at Fermilab imposes stringent requirements on the elimination of out-of-time beam in its pulsed proton beam - a requirement known as "extinction". We present a method to measure the out-of-time particle rates to calculate the level of extinction in the inter-pulse gaps. The proposed method utilizes an array of quartz Cherenkov radiators and photomultiplier tubes to detect particles scattered from a vacuum chamber in the M4 transfer beamline at Fermilab.The measurement will employ a new μTCA-based FPGA system for data acquisition and signal processing, utilizing real-time peak detection algorithms to count scattered beam particles. By integrating data over many transfers, the time profile of the out-of-time beam will be resolved to fractional levels relative to that of the in-time beam. These results are compared with G4beamline simulations to validate models of beam transport, dynamics, and extinction, providing critical input for optimizing beam delivery to Mu2e.

Hensley, Ryan [UC, Davis]↗

Charged particle diagnostics for inertial confinement fusion and high-energy-density physics experiments

MeV-range ions generated in inertial confinement fusion (ICF) and high-energy-density physics experiments carry a wealth of information, including fusion reaction yield, rate, and spatial emission profile; implosion areal density; electron temperature and mix; and electric and magnetic fields. Here, the principles of how this information is obtained from data and the charged particle diagnostic suite currently available at the major US ICF facilities for making the measurements are reviewed. Time-integrating instruments using image plate, radiochromic film, and/or CR-39 detectors in different configurations for ion counting, spectroscopy, or emission profile measurements are described, along with time-resolving detectors using chemical vapor deposited diamonds coupled to oscilloscopes or scintillators coupled to streak cameras for measuring the timing of ion emission. A brief description of charged-particle radiography setups for probing subject plasma experiments is also given. The goal of the paper is to provide the reader with a broad overview of available capabilities, with reference to resources where more detailed information can be found.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Kinetic and X-ray Absorption Spectroscopic Analysis of Catalytic Redox Cycles over Highly Uniform Polymetal Oxo Clusters

Metal–organic framework materials (MOFs) offer an opportunity for investigating catalytic properties of polymetal oxo clusters that are highly well defined and uniform in nature, in contrast to other classes of catalysts that may exhibit a propensity toward active site heterogeneity. We report herein a kinetic and X-ray absorption spectroscopy (XAS) analysis of the two-electron oxidation of CO over divalent metal sites in MIL-100(M = Fe, Cr) (MIL = Materials of Institut Lavoisier) materials carrying μ 3 -oxo bridged trimers, and connect observations about the kinetic relevance of redox steps to density functional theory (DFT) predictions published previously. The high degree of uniformity evident from in situ titration measurements leads to a congruence in mechanistic inferences made from steady-state catalytic, transient stoichiometric, isotopic exchange, and isotopic tracer data that all point to a sequential mechanism comprised of separate oxidation and reduction half-cycle steps conjoined by an active oxygen intermediate. In situ XAS data reinforce mechanistic conclusions derived from kinetic analysis, and suggest that the active oxygen intermediate may be more appropriately characterized as an iron-oxyl (Fe 3+ –O – ) rather than an iron-oxo (Fe 4+ =O 2– ) species. The Cr analogue of MIL-100 exhibits contrasting rate features that can be rationalized using an identical sequence of steps as MIL-100(Fe), but with a highly dissimilar set of kinetic parameters that can also be validated using transient stoichiometric experiments. The larger coverages of active oxygen intermediates on MIL-100(Cr) are consistent with predictions from prior DFT studies that suggest more stable and less reactive active oxygen species for metals with lower d-electron counts, and point to metal identity as a lever for precisely controlling the kinetic relevance of oxidation and reduction half-cycles in catalytic redox sequences over polymetal oxo clusters. Importantly, the results presented point to the utility of developing broadly applicable structure–catalytic property relationships over MOF nodes specifically, and highly uniform catalysts more generally.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Analysis of Loss-of-Offsite-Power Events: 2021 Update

Loss-of-offsite power (LOOP) can have a negative impact on a nuclear power plant’s ability to achieve and maintain safe shutdown conditions. LOOP event frequencies and times required for subsequent restoration of offsite power are important inputs to plant probabilistic risk assessments. This report presents a statistical and engineering analysis of LOOP frequencies and durations at U.S. commercial nuclear power plants. The data used in this study were based on the operating experience during calendar years 1987–2021, while the most recent 15-year data (i.e., from 2007–2021) were used for most analyses in this report. LOOP events during critical operation that did not result in a reactor trip are not included. Frequencies and durations were determined for four LOOP event categories: plant-centered, switchyard-centered, grid-related, and weather-related. These categories (and the All-LOOPs group which contains all LOOPs without regarding of the four categories) could be further grouped by whether a LOOP event occurred during critical operation, during shutdown operation, or during all operations. The following decreasing trends in the LOOP occurrence rates were identified for the most recent 10-year period (2012–2021): All-LOOPs during critical operation, switchyard-centered LOOPs during critical operation, and grid-related LOOPs during critical operation. Adverse trends in LOOP durations continue for switchyard-centered LOOPs during all operations, All-LOOPs during all operations, and All-LOOPs during shutdown operation for the 1997–2021 period. Statistical tests show the LOOP counts for the period of 2007–2021 are not uniformly distributed across the 12 months, and variation among the months exists for grid-related LOOPs during all operations, All-LOOPs during all operations, and All-LOOPs during critical operation. The engineering analysis of LOOP data showed for the period of 2007–2021, the equipment failure events were dominated by failures of relay and other; human errors have been less frequent and occurred primarily in maintenance and switching; and weather were dominated by tornadoes then by lightning and hurricane. Weather was the cause for 45% of LOOPs for the last fifteen years (2007– 2021) but only for 20% of LOOPs for the previous 20 years (1987–2006) .

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Characterization and Optimization of Skipper CCDs for the SOAR Integral Field Spectrograph

We present results from the characterization and optimization of Skipper charge-coupled devices (CCDs) for use in a focal plane prototype for the Southern Astrophysical Research Integral Field Spectrograph (SIFS). We tested eight Skipper CCDs and selected six for SIFS based on performance results. The Skipper CCDs are 6k × 1k, 15 μm pixels, thick, fully depleted, p-channel devices that have been thinned to ~250 μm, backside processed, and treated with an anti-reflective coating. We demonstrate a single-sample readout noise of <4.3 e - rms pixel -1 in all amplifiers. We optimize the readout sequence timing to achieve a readout noise of 0.5 e - rms pixel -1 after 74 non-destructive measurements, which can be accomplished in a region covering 5% of the detector area in a readout time of <4 minutes. We demonstrate single-photon-counting in all 24 amplifiers (four amplifiers per detector) with a readnoise of σ N ~ 0.18 e - rms pixel -1 after N samp = 400 samples, and we constrain the degree of nonlinearity to be ≲1% at low signal levels (0 e - to 50 e - ). Clock-induced charge (CIC) remains an important issue when the Skipper CCD is configured to provide a large full-well capacity. We achieve a CIC rate of <1.45 × 10 -3 e - pixel -1 frame -1 for a full-well capacity of ~900 e - , which increases to a CIC rate of ~3 e - pixel -1 frame -1 for full-well capacities ~40,000-65,000 e - . We also perform conventional CCD characterization measurements such as charge transfer inefficiency (3.44 × 10 -7 on average), dark current (~2 × 10 -4 e - pixel -1 s -1 ), photon transfer curves, cosmetic defects (<0.45% “bad” pixels), and charge diffusion (point-spread function < 7.5 μm) to verify that these properties are consistent with expectations from conventional p-channel CCDs used for astronomy. Furthermore, we provide the first measurements of the brighter-fatter effect and absolute quantum efficiency (≳80% between 450 and 980 nm; ≳90% between 600 and 900 nm) using Skipper CCDs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗