Search NASA⌕ Search

SEARCH · Search NASA

Results for “Computational Fluid Dynamics Conduction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Intermediate Temperature Proton‐Conducting Solid Oxide Electrolysis Cells with Improved Performance and Durability

Technical understanding: A high-performance and stable intermediate temperature proton-conducting solid oxide electrolysis cell (PCEC) will add significantly to the hydrogen roadmap of EERE. However, the low electrocatalytic activity of the air electrode and the instability of the electrolyte are technical barriers. In this research, we utilized computational fluid dynamic modeling and materials/microstructure engineering to investigate the complex reaction chain and to improve the performance and reliability of the protonic ceramic electrochemical cells. An active and stable Pr 1.8 Ba 0.2 NiO 4+δ -BaZr 0.1 Ce 0.7 Y 0.1 Yb 0.1 O 3-δ (BZCYYb) scaffold conformal coating electrode was rationally designed where the robust Pr 1.8 Ba 0.2 NiO 4+δ functions both as a catalytic active and a protective layer. The PCECs with porosity-optimized scaffold conformal coating electrodes demonstrate 1.46 Acm -2 under 1.3 V at 600°C, which is among the highest in recent years. The final optimization by computational fluid dynamic modeling and conformal coating technique was applied to evolve the PCEC air electrode from Pr 2 NiO 4+δ to Pr 1.8 Ba 0.2 NiO 4+δ -BaZr 0.1 Ce 0.7 Y 0.1 Yb 0.1 O 3-δ scaffold conformal coating. The electrolysis current was boosted from 0.445A/cm 2 to 1.46A/cm 2 at 600°C and 1.3V. A superior low degradation rate of 1mV/kh was achieved in a 5000-hour of operation. Technical effectiveness and economic feasibility: The effectiveness of this TCO conformal coating on electrolyte backbone as air electrode has been proven by long-term demonstration. Based on the highly conductive BZCYYb electrolyte and the TCO steam electrode PNO, this project rationally took advantage of the existent materials to structure a PCEC device with high TRL and low risk. The solution infiltration method used to structure the conformal coating is a standard method used by the solid oxide cell community. Very minimal adoption is needed in the current SOC fabrication process. It is a cost-effective, scalable method for manufacturing, and brings up remarkable impact on the current technical status of PCEC. Benefit to the public: The findings in the research showed the industry that the severe challenge in PCEC can be overcome in a practical way. A various energy-hydrogen ecosystem is not beyond reach. The success of this technology provides sustainable and affordable H 2 to society. It will stimulate investment from the governmental and private sectors in response to the device manufacture and deployment, and the related infrastructure construction. It will generate high-pay domestic jobs and environmental benefits to the general public in the United States.

08 HYDROGEN↗

Single-Fuel Reactivity Controlled Compression Ignition Combustion Enabled by Onboard Fuel Reformation (Final Report)

Reactivity-Controlled Compression Ignition (RCCI) is a promising new advanced, low temperature combustion mode that offers efficiencies equal to or greater than conventional diesel combustion, but significantly lower soot and NOx emissions. Additionally, RCCI has enhanced controllability over the combustion process compared to some of the other advanced combustion modes. Therefore, RCCI combustion has the potential to be of great benefit to the public by increasing the efficiency and reducing the harmful pollutant emissions from transportation. However, RCCI combustion achieves this favorable level of performance through the use of two distinct fuels (e.g., diesel and gasoline, diesel and natural gas, or diesel and ethanol). In a vehicle application, RCCI therefore requires two different fuel tanks and fuel injection systems, which presents a significant drawback to the commercialization RCCI. This project proposed a new concept to enable RCCI combustion from a single parent fuel stored onboard the vehicle in a single fuel tank. Specifically, the parent fuel would be stored in the fuel tank and one branch of the fuel system would deliver the parent fuel, unaltered, to the cylinder, while a second branch of the fuel system would route the parent fuel through a fuel reformer to chemically react the fuel into a gaseous fuel mixture, called “reformate”, that has different properties from the original parent fuel. In this way, there can be two fuels at the engine that have different properties, but only one parent fuel needs to be stored and refilled in the vehicle. This initial, exploratory investigation into the feasibility of this promising new concept included reacting three potential parent fuels (diesel, gasoline, and natural gas) in a fuel reformer and determining the composition of the gaseous reformate fuel that exited the fuel reformer. There are different types of reformation processes, but since this project was a proof-of-concept investigation into the potential of Single-Fuel RCCI and the combustion process in the cylinder, a catalytic partial oxidation (CPOX) reformation process was selected, which is more straightforward to perform and control, and would potentially be easier to implement in a vehicle application compared to other reformation processes. Once the three parent fuels were reformed to varying degrees and their reformate compositions were determined, their autoignition tendencies were experimentally determined by comparing advanced combustion results of the reformate mixtures with known reference fuels. This showed that diesel fuel and its reformate fuel mixture exhibited the largest reactivity separation, which is necessary to enable RCCI combustion in the cylinder. Using diesel fuel as the parent fuel, experimental testing was conducted to provide a better understanding of the operational considerations, benefits, and drawbacks of Single-Fuel RCCI with onboard fuel reformation. The experimental testing was accompanied by computational fluid dynamics and system-level modeling to help complement the experiments and further expand the understanding. The main conclusions are that Single-Fuel RCCI using diesel fuel as the direct injected, high reactivity fuel and diesel’s gaseous reformate mixture as the premixed, low reactivity fuel is viable. The efficiencies were equal to, or sometimes greater than, RCCI with conventional fuel pairs, and the emissions were comparable as well. A key consideration is that gaseous reformate fuel contains a large amount of diluents in the fuel which displace air entering the cylinder and act as EGR inside the cylinder. Additionally, the reactivity separation between diesel and its reformate fuel mixture is larger than diesel-gasoline, but less than diesel-natural gas, and the combustion process therefore responded in a manner that was between the two conventional fuel pairs. Finally, although achievable in the cylinder, there are practical drawbacks or other disadvantages of Single-Fuel RCCI with onboard fuel reformation. First, this project used a CPOX reformation process which is exothermic, meaning that a portion of the fuel’s energy was released in the reformer where it could not be converted into useful work. This constituted an efficiency penalty of the system of on the order of 10% or 4 percentage points. Future research should therefore focus on alternate reforming processes including steam-methane reforming or autothermal reforming where there might not be any energy released in the reformer, or there could even be an energy gain in the reformer (through an endothermic process with waste heat recovery). Practical drawbacks that exist, but were beyond the scope of this preliminary proof-of-concept research project, are the added cost of the fuel reformer, which is a catalyst made of precious metals, transient response of the system, and the lifetime of the fuel reformer.

33 ADVANCED PROPULSION SYSTEMS↗

SACCON Forced Oscillation Tests at DNW-NWB and NASA Langley 14x22-Foot Tunnel

A series of three wind tunnel static and forced oscillation tests were conducted on a generic unmanned combat air vehicle (UCAV) geometry. These tests are part of an international research effort to assess the state-of-the-art of computational fluid dynamics (CFD) methods to predict the static and dynamic stability and control characteristics. The experimental dataset includes not only force and moment time histories but surface pressure and off body particle image velocimetry measurements as well. The extent of the data precludes a full examination within the scope of this paper. This paper provides some examples of the dynamic force and moment data available as well as some of the observed trends.

Vicroy Dan D.↗

An Empirical Non-TNT Approach to Launch Vehicle Explosion Modeling

In an effort to increase crew survivability from catastrophic explosions of Launch Vehicles (LV), a study was conducted to determine the best method for predicting LV explosion environments in the near field. After reviewing such methods as TNT equivalence, Vapor Cloud Explosion (VCE) theory, and Computational Fluid Dynamics (CFD), it was determined that the best approach for this study was to assemble all available empirical data from full scale launch vehicle explosion tests and accidents. Approximately 25 accidents or full-scale tests were found that had some amount of measured blast wave, thermal, or fragment explosion environment characteristics. Blast wave overpressure was found to be much lower in the near field than predicted by most TNT equivalence methods. Additionally, fragments tended to be larger, fewer, and slower than expected if the driving force was from a high explosive type event. In light of these discoveries, a simple model for cryogenic rocket explosions is presented. Predictions from this model encompass all known applicable full scale launch vehicle explosion data. Finally, a brief description of on-going analysis and testing to further refine the launch vehicle explosion environment is discussed.

Blackwood, James M.↗

Modeling the Drying of a Mock Used Fuel Assembly with COBRA-SFS Cycle-4 - 18597

The processing and storage of nuclear fuel is an ever increasingly pressing issue. Around 70,000 tons of used fuel are currently in either dry or wet storage on site at nuclear power plants or at specified spent fuel storage facilities. Additionally, about 2,000 tons are added to that sum each year. To promote retrievability, limit degradation in the canister, and reduce potential for hydrogen generation, spent fuel that is initially in wet storage must be dried before moving to dry cask storage. Therefore, this research seeks to use a mock used fuel storage cask to replicate the conditions in the industry during the drying process of fuel being moved from storage pools. To simulate this, a mock storage cask has been constructed to closely resemble those used in industry such that any areas that tend to retain water are replicated effectively. It is able to hold one mock used fuel assembly. The assembly used is an AREVA 10A 10 x 10 assembly with 78 rods filled with depleted uranium, 12 heater rods to simulate decay heat, a 3 x 3 BWR water channel, and one interchangeable rod position for tests such as a simulated failed fuel rod, BWR water rod, and PWR guide tube tests. The industry standard procedure is used in drying the assembly which involves stepping the system pressure down and holding for certain periods until reaching 3 torr and holding for 30 minutes. This is believed to sufficiently dry the assembly. The goal is to record data throughout these tests that can provide the industry with a greater understanding of how well the process works. This data will also be used to develop and validate a computer model of the drying process. Mechanistic models are currently under development. Reduced order models are being investigated for incorporation into current related engineering codes such as COBRA-SFS. COBRA-SFS is a member of the COBRA family of codes which is mainly used in the evaluation of thermal hydraulic systems containing spent nuclear fuel. However, it does not currently have the capability to account for processes such as evaporation encountered during drying operations. Therefore, those physical models are to be added to the source code. At present a model of the experiment has been created using the COBRA-SFS Cycle-4 code. A number of steady state models along with transient models have been developed and presented. Each of these yield valuable results for comparison with the experiments conducted. In addition to comparison with experimental results, the data collected from COBRA-SFS is compared with that which has been generated from other computer models which utilize computational fluid dynamics. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

THERMAL ANALYSIS OF GEOLOGIC HIGH-LEVEL RADIOACTIVE WASTE PACKAGES

The engineering design of disposal of the high level waste (HLW) packages in a geologic repository requires a thermal analysis to provide the temperature history of the packages. Calculated temperatures are used to demonstrate compliance with criteria for waste acceptance into the geologic disposal gallery system and as input to assess the transient thermal characteristics of the vitrified HLW Package. The objective of the work was to evaluate the thermal performance of the supercontainer containing the vitrified HLW in a non-backfilled and unventilated underground disposal gallery. In order to achieve the objective, transient computational models for a geologic vitrified HLW package were developed by using a computational fluid dynamics method, and calculations for the HLW disposal gallery of the current Belgian geological repository reference design were performed. An initial two-dimensional model was used to conduct some parametric sensitivity studies to better understand the geologic system's thermal response. The effect of heat decay, number of co-disposed supercontainers, domain size, humidity, thermal conductivity and thermal emissivity were studied. Later, a more accurate three-dimensional model was developed by considering the conduction-convection cooling mechanism coupled with radiation, and the effect of the number of supercontainers (3, 4 and 8) was studied in more detail, as well as a bounding case with zero heat flux at both ends. The modeling methodology and results of the sensitivity studies will be presented.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Characterization of the Finite Element Computational Fluid Dynamics Capabilities in the Multiphysics Object Oriented Simulation Environment

We report the multiphysics object-oriented simulation environment (moose) is a code package that couples a variety of physics modules, allowing for highly accessible multiphysics simulations. The physics modules include a finite element Navier–Stokes (N–S) module that is designed to solve laminar fluid dynamics problems. The usage of this module in multiple recent studies coupled with the growing interest in moose for usage in nonlight water reactor safety studies by the Nuclear Regulatory Commission (NRC) prompted the authors to investigate the computational fluid dynamics capabilities of moose. A two-dimensional laminar flow past a circular cylinder scenario is simulated in the moose framework to investigate the effectiveness of the N–S module. Simulations assumed an unsteady laminar flow with a Reynolds number of 200. To verify the results from moose, similar simulations were conducted using the well-utilized simulation of turbulent flow in arbitrary regions—computational continuum mechanics C++ (star-ccm + ) finite volume code. Results from both codes are also compared to some results from literature. Velocity and pressure profiles of both transient simulations were compared. The numerical and input errors in moose are also visualized with contour plots to qualitatively understand the evolution of the errors across time and space. The comparisons between moose and star-ccm + showed nearly perfect agreement between the codes for velocity and pressure, especially after the development of the vortex street in later time-steps. The force coefficients showed excellent agreement after the development of the vortex street, but demonstrated notable discrepancies prior to the vortex street development, which is likely due to how each code simulated the approach to the vortex street in earlier time-steps.

97 MATHEMATICS AND COMPUTING↗

A Simulation Framework for Analyzing the Impact of Stochastic Occupant Behaviors on Demand Flexibility in Typical Commercial Buildings

As one of the primary users of the electric grid, buildings and building equipment, including heating, ventilation, and air conditioning (HVAC) systems, can be leveraged to provide the flexible demand needed to balance the grid. Typical strategies to achieve demand flexibility are to reduce electricity use during peak or critical periods by shutting down equipment or relaxing system setpoints, which will inevitably impact the occupants’ comfort. When occupants feel uncomfortable, they may take actions to regain their comfort, and some of those actions (such as turning on a personal fan) may have a negative impact on meeting the demand response goal. Therefore, it is important to incorporate occupant behaviors into the assessment ofthe building demand flexibility potential. In this study, a simulation framework that includes simulation of zone thermal loads, an HVAC system, and occupant behaviors, was developed to investigate the impact of occupant behaviors on demand flexibility. A case study was conducted using a small office model from the U.S. Department of Energy (DOE) Commercial Prototype Building Models to simulate the building envelope and zone loads. An agent-based occupant thermal behavior model was adapted to forecast occupants’ thermal comfort and their resulting thermal behaviors. An artificial neural network (ANN) based airflow model trained from a computational fluid dynamics (CFD) model of the zone was adopted to better predict the ambient environment of each occupant. An air-source heat pump simulation model that was calibrated from a real two-stage air-source heat pump system was used as the HVAC system. A typical load shedding event during peak hours was studied. Repeated simulations were conducted to capture the stochastic effects of occupant behaviors. The interplay between the demand flexibility, occupant comfort and behavior were analyzed by evaluating key performance indicators, including the energy use, occupant discomfort duration, and occupant behavior duration during the peak period. The results suggest that this framework can be used to analyze typical commercial buildings and their HVAC systems in terms ofdemand flexibility potential under the impact of occupant behaviors.

Chen, Zhelun↗

Whitepaper: Optimal Control from a Fluid Dynamics Perspective

An optimal control problem described by the Hamilton-Jacobi-Bellman equation can be developed into a problem that can be solved by general computational fluid dynamics packages. We describe how this formulation would allow a classical problem in optimal control, Zermelo’s problem, to be treated as a multi-fluid problem. This approach has the advantage of allowing optimal navigation problems to be conducted over large areas, as well as to include moderately larger numbers of ships. We draw comparisons between this approach and the field of fluid control for fluid animations in movies.

42 ENGINEERING↗

Fuel-Flexible Combustion System for Refinery and Chemical Plant Process Heaters

This project culminated in the demonstration of a full-scale industrial burner which allows a broad range of “opportunity” gaseous fuels to be cost-effectively and efficiently utilized while generating minimal emissions of criteria air pollutants. The burner is capable of maintaining a stable flame when the fuel composition changes rapidly. This enhanced stability will contribute significantly to improving the safety and reliability of burner operation in manufacturing sites. Process heating in the refining and chemicals sectors is the primary application for this burner. The refining and chemical sectors account for more than 40% of total industrial natural gas use. Prior to the completion of this project, an enabling technology did not exist that would allow these energy-intensive industries to take full advantage of opportunity fuels and thereby reduce their natural gas consumption. Opportunity gaseous fuels include biogas (from animal and agricultural wastes, wastewater plants, and landfills) as well as syngas (from the gasification of biomass, municipal solid wastes, construction wastes, and refinery residuals). The primary challenge to using gaseous opportunity fuels is that their composition and combustion performance differ significantly from those of conventional fuels such as natural gas and refinery fuel gas. An effective fuel-flexible burner must accept fuels that range widely in quality and change in composition over time, often rapidly. In Phase 1 of this project, the team applied computational fluid dynamics analysis to optimize the prototype burner’s aerodynamic, combustion, heat transfer, and emissions performance. In Phase 2, full-scale testing and refinement of two prototype burners were conducted in test furnaces at Zeeco’s offices in Broken Arrow, OK. These tests demonstrated that the full range of conventional and opportunity fuels could be utilized by the project’s burner while achieving robust flame stability and very low levels of air pollutant emissions. In Phase 3, the team retrofitted three fuel-flexible burners into a fired heater at a Shell plant and demonstrated the project’s technology over a 6-month period. The project burners performed well during this period. They remain in commercial service at the Shell plant. Through this work, an improved understanding of flame stabilization mechanisms was gained. Also, methods for accommodating a wide range of fuel compositions were developed. This knowledge facilitated the commercialization of a new generation of burners that are suitable for the fuels of the future.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Overview of the Aeroelastic Prediction Workshop

The AIAA Aeroelastic Prediction Workshop (AePW) was held in April, 2012, bringing together communities of aeroelasticians and computational fluid dynamicists. The objective in conducting this workshop on aeroelastic prediction was to assess state-of-the-art computational aeroelasticity methods as practical tools for the prediction of static and dynamic aeroelastic phenomena. No comprehensive aeroelastic benchmarking validation standard currently exists, greatly hindering validation and state-of-the-art assessment objectives. The workshop was a step towards assessing the state of the art in computational aeroelasticity. This was an opportunity to discuss and evaluate the effectiveness of existing computer codes and modeling techniques for unsteady flow, and to identify computational and experimental areas needing additional research and development. Three configurations served as the basis for the workshop, providing different levels of geometric and flow field complexity. All cases considered involved supercritical airfoils at transonic conditions. The flow fields contained oscillating shocks and in some cases, regions of separation. The computational tools principally employed Reynolds-Averaged Navier Stokes solutions. The successes and failures of the computations and the experiments are examined in this paper.

Heeg, Jennifer↗

Mach 5 to 7 RBCC Propulsion System Testing at NASA-LeRC HTF

A series of Mach 5 to 7 freejet tests of a Rocket Based Combined Cycle (RBCC) engine were cnducted at the NASA Lewis Research Center (LERC) Hypersonic Tunnel Facility (HTF). This paper describes the configuration and operation of the HTF and the RBCC engine during these tests. A number of facility support systems are described which were added or modified to enhance the HTF test capability for conducting this experiment. The unfueled aerodynamic perfor- mance of the RBCC engine flowpath is also presented and compared to sub-scale test results previously obtained in the NASA LERC I x I Supersonic Wind Tunnel (SWT) and to Computational Fluid Dynamic (CFD) analysis results. This test program demonstrated a successful configuration of the HTF for facility starting and operation with a generic RBCC type engine and an increased range of facility operating conditions. The ability of sub-scale testing and CFD analysis to predict flowpath performance was also shown. The HTF is a freejet, blowdown propulsion test facility that can simulate up to Mach 7 flight conditions with true air composition. Mach 5, 6, and 7 facility nozzles are available, each with an exit diameter of 42 in. This combination of clean air, large scale, and Mach 7 capabilities is unique to the HTF. This RBCC engine study is the first engine test program conducted at the HTF since 1974.

Perkins, H. Douglas↗

Data Driven Smart Proxy for CFD Application of Big Data Analytics & Machine Learning in Computational Fluid Dynamics, Report Two: Model Building at the Cell Level

To ensure the usefulness of simulation technologies in practice, their credibility needs to be established with Uncertainty Quantification (UQ) methods. In this project, smart proxy is introduced to significantly reduce the computational cost of conducting large number of multiphase CFD simulations, which is typically required for non-intrusive UQ analysis. Smart proxy for CFD models are developed using pattern recognition capabilities of Artificial Intelligence (AI) and Data Mining (DM) technologies. Several CFD simulation runs with different inlet air velocities for a rectangular fluidized bed are used to create a smart CFD proxy that is capable of replicating the CFD results for the entire geometry and inlet velocity range. The smart CFD proxy is validated with blind CFD runs (CFD runs that have not played any role during the development of the smart CFD proxy). The developed and validated smart CFD proxy generates its results in seconds with reasonable error (less than 10%). Upon completion of this project, UQ studies that rely on hundreds or thousands of smart CFD proxy runs can be accomplished in minutes. Following figure demonstrates a validation example (blind CFD run) showing the results from the MFiX simulation and the smart CFD proxy for pressure distribution across a fluidized bed at a given time-step (the layer number corresponds to the vertical location in the bed).

97 MATHEMATICS AND COMPUTING↗

Data Driven Smart Proxy for CFD Application of Big Data Analytics & Machine Learning in Computational Fluid Dynamics, Part Three: Model Building at the Layer Level

To ensure the usefulness of simulation technologies in practice, their credibility needs to be established with Uncertainty Quantification (UQ) methods. In this project smart proxy is introduced to significantly reduce the computational cost of conducting large number of multiphase CFD simulations. Smart proxy for CFD models are developed using pattern recognition capabilities of Artificial Intelligence (AI), Machine Learning (LM) and Data Mining (DM) technologies. Several CFD simulation runs with different inlet air velocities for a rectangular fluidized bed are used to create a smart CFD proxy that is capable of replicating the CFD results for a wide variety of inlet velocities. The smart CFD proxy is validated with blind CFD runs (CFD runs that have not played any role during the development [training, calibration and validation] of the smart CFD proxy). In our earlier work, CFD data was used to train ANN at the cell level. That is an ANN was trained for each computational cell used in the CFD simulations. In the present work, the ANN is constructed and trained based on cross sectional area average of each variable, such as pressure, velocities and volume fraction (Layer Level). This leads to improvements in the training time at the expense of less spatial resolution. The resulting trained ANN provides spatially average value of parameters of interest, along the length of the fluidized bed. Upon completion of this project, UQ studies that rely on hundreds or thousands of smart CFD proxy runs can be accomplished in minutes. Following figure demonstrates a validation example (blind CFD run) showing the results from the MFiX and the smart CFD proxy for pressure drop across a fluidized bed at time-step of 1400 (the layer number corresponds to the vertical location in the bed).

97 MATHEMATICS AND COMPUTING↗

Assessment of Near-Field Sonic Boom Simulation Tools

A recent study for the Supersonics Project, within the National Aeronautics and Space Administration, has been conducted to assess current in-house capabilities for the prediction of near-field sonic boom. Such capabilities are required to simulate the highly nonlinear flow near an aircraft, wherein a sonic-boom signature is generated. There are many available computational fluid dynamics codes that could be used to provide the near-field flow for a sonic boom calculation. However, such codes have typically been developed for applications involving aerodynamic configuration, for which an efficiently generated computational mesh is usually not optimum for a sonic boom prediction. Preliminary guidelines are suggested to characterize a state-of-the-art sonic boom prediction methodology. The available simulation tools that are best suited to incorporate into that methodology are identified; preliminary test cases are presented in support of the selection. During this phase of process definition and tool selection, parallel research was conducted in an attempt to establish criteria that link the properties of a computational mesh to the accuracy of a sonic boom prediction. Such properties include sufficient grid density near shocks and within the zone of influence, which are achieved by adaptation and mesh refinement strategies. Prediction accuracy is validated by comparison with wind tunnel data.

Casper, J. H.↗

A dynamic 2D Borehole Thermal Energy Storage (BTES) model for enhanced computational efficiency

Progressing toward a future increasingly reliant on renewable energy sources, the development of effective, durable energy storage solutions becomes essential to balance supply and demand fluctuations. Borehole Thermal Energy Storage (BTES) is a long-duration thermal energy storage technology that captures excess heat generated from renewable energy sources and stores it underground for later use, enabling the efficient utilization of sustainable energy. This approach is particularly valuable in district energy networks when integrated with Ground Source Heat Pumps (GSHP) to provide stable heating and cooling. However, traditional three-dimensional (3D) numerical models of BTES systems demand extensive computational resources, limiting their practicality for real-time and large-scale applications. This study introduces a novel two-dimensional (2D) modeling approach that reduces computational costs while maintaining high accuracy. By employing a radial ring-based discretization method, the model simulates heat injection, retention, and retrieval dynamics over seasonal cycles. A new thermal-mass weighted-average temperature parameter is introduced to evaluate the performance of BTES systems. Model validation against FEFLOW simulations demonstrates a 17-fold improvement in computational speed compared to traditional Computational Fluid Dynamics (CFD) models while achieving a mean absolute percentage error (MAPE) of 2 % during charging and 4 % during discharging. Additionally, a trade-off analysis between computational efficiency and accuracy is conducted, ensuring the model's applicability for real-world scenarios. The findings of this research contribute to the development of computationally efficient BTES models, facilitating better optimization, control, and integration into renewable energy systems. This work provides a foundation for further studies in techno-economic analysis, multi-year performance evaluation, and real-time operational strategies for BTES applications, supporting a more sustainable energy future.

2D modeling↗

Heat transfer in rotating passages with smooth walls and radial outward flow

Experiments were conducted to determine the effects of rotation on heat transfer in turbine blade internal coolant passages. The experiments were conducted with a smooth wall, large-scale heat transfer model. The objective was to obtain the heat transfer data base required to develop heat transfer correlations and to assess computational fluid dynamic techniques for rotating coolant passages. An analysis of the governing equations showed that four parameters influence the heat transfer in rotating passages (coolant density ratio, Rossby number, Reynolds number, and radius ratio). These four parameters were varied over ranges that exceed the ranges of current open literature results, but that are typical of current and advanced gas turbine engine operating conditions. Rotation affected the heat transfer coefficients differently for different locations in the coolant passage. For example, heat transfer at some locations increased with rotation, but decreased and then increased again at other locations. Heat transfer coefficients varied by as much as a factor of five between the leading and trailing surfaces for the same test condition and streamwise location. Comparisons with previous results are presented.

Wagner, J. H.↗

Euler Technology Assessment program for preliminary aircraft design employing SPLITFLOW code with Cartesian unstructured grid method

This report documents results from the Euler Technology Assessment program. The objective was to evaluate the efficacy of Euler computational fluid dynamics (CFD) codes for use in preliminary aircraft design. Both the accuracy of the predictions and the rapidity of calculations were to be assessed. This portion of the study was conducted by Lockheed Fort Worth Company, using a recently developed in-house Cartesian-grid code called SPLITFLOW. The Cartesian grid technique offers several advantages for this study, including ease of volume grid generation and reduced number of cells compared to other grid schemes. SPLITFLOW also includes grid adaptation of the volume grid during the solution convergence to resolve high-gradient flow regions. This proved beneficial in resolving the large vortical structures in the flow for several configurations examined in the present study. The SPLITFLOW code predictions of the configuration forces and moments are shown to be adequate for preliminary design analysis, including predictions of sideslip effects and the effects of geometry variations at low and high angles of attack. The time required to generate the results from initial surface definition is on the order of several hours, including grid generation, which is compatible with the needs of the design environment.

Finley, Dennis B.↗