Search NASA⌕ Search

SEARCH · Search NASA

Results for “Computational imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Data Validation: Difference Imaging and Centroid Analysis

This Design Note describes the theory and application of difference imaging for automated validation of planet candidates in the Data Validation (DV) CSCI. This is one of the diagnostic tools employed in DV for planet candidate validation. The other DV diagnostics are described in separate KADNs and in the reference documents listed below. This document describes the difference image generation process, PRF-based centroiding of the out-of-transit and difference images, computation of quarterly centroid offsets and associated uncertainties, and determination of robust weighted mean centroid offsets/uncertainties over all available quarterly data sets. PRF-based centroiding is performed with calls to a library of functions that is shared with thePhotometric Analysis (PA) and Photometer Data Quality (PDQ) CSCIs. The centroiding library will be the subject of a separate Design Note.

Twicken, Joseph↗

Using X-Ray Computed Tomography to Image Apollo Drive Tube 73002

The Apollo missions collected 382 kg of rock, regolith, and core samples from six locations on the nearside of the Moon. Today, just over 84% by mass of the Apollo collection remains in pristine condition within the curation facility at Johnson Space Center. Most Apollo samples have been well characterized, however there are several types of samples that have remained wholly or largely unstudied since their return, and/or that have been curated under special conditions. These sample types are: (1) unopened samples sealed under vacuum on the Moon; (2) unopened (but unsealed) drive tubes; (3) Apollo 17 samples frozen shortly after their return; and (4) Apollo 15 samples opened and stored in a helium atmosphere since their return. Last summer, NASA solicited proposals for the Apollo Next Generation Sample Analysis Program (ANGSA), and 9 teams were selected to study: (1) unsealed, unopened drive tube 73002; (2) sealed, unopened drive tube 73001 (paired with 73002); and (3) a subset of the frozen and He-purged samples [1]. The first sample opened as part of the ANGSA program was drive tube 73002. This is a 30 cm long, 4 cm diameter drive tube collected on a landslide deposit near Lara Crater at the Apollo 17 landing site. It was part of a 60 cm long double drive tube collected, and the bottom half of the tube (73001) was sealed under vacuum on the Moon [2]. Prior to opening sample 73002, the sample was imaged with a high resolution Xray Computed Tomography (XCT) scan of the entire tube. Additional XCT scans have been made of “large” clasts removed from the core as part of the dissection process [3]. Here we present a first look at the XCT data from 73002, and talk about the utility of the scans as part of the curation process, including the potential for future science returns from the high resolutions scans.

Zeigler, R. A.↗

Development of a Computer Tool to Analyze MISSE Images

The Materials International Space Station Experiment (MISSE) contains individual experiments focused on the investigation of the effects that occur because of the exposure of the material to the space environment. The specimens are mounted on the exterior of the International Space Station (ISS) on the MISSE-Flight Facility (MISSE-FF) and are exposed to the extreme environmental conditions. There have been 14 MISSE missions since the establishment in 2001. This project will evaluate MISSE 9 - MISSE 13 specimens and how they change due to the space environment.

MISSE↗

Stimuli Responsive/Rheoreversible Hydraulic Fracturing Fluids for Enhanced Geothermal Energy Production (Part II)

We have used an environmentally friendly and recyclable hydraulic fracturing fluid - diluted aqueous solutions of polyallylamine or PAA – for reservoir stimulation in Enhanced Geothermal System (EGS). This fluid undergoes a controlled and large volume expansion with a simultaneous increase in viscosity triggered by CO2 at EGS temperatures. We are presenting here the results of laboratory-scale hydraulic fracturing experiment using the fluid on small cylindrical rock cores (1.59 cm in diameter and 5.08 cm in length) from the Coso geothermal field in California. Rock samples consisted of Mesozoic diorite metamorphosed to greenschist facies. The experiments were conducted on 5 samples for realistic ranges of pressures (up to 275 bar) and temperatures (up to 210 °C) for both the rock samples and the injected fluid. After fracturing, cores were subjected to a CO2 leakage test, injection of KI solution, and X-ray microtomography (XMT) scanning to examine the formation and distribution of fractures. The design and conduct of these experiments will be presented and discussed in details. Based on the obtained XMT images, Computational Fluid Dynamics (CFD) simulations were then performed to visualize hydraulic fractures and compute the bulk permeability. OpenFOAM (OpenCFD Ltd., Reading, UK), was used to solve the steady state simulation. The flow predictions, based upon the laminar, 3-D, incompressible Navier-Stokes equations for fluid mass and momentum, show the remarkable stimulation of the permeability in the core samples and demonstrate the efficiency of such a CO2 triggered fluid in EGS.

CO2-activated↗

ShrinkWrap: 3D model abstraction for remote sensing simulation

Remote sensing simulations often require the use of 3D models of objects of interest. There are a multitude of these models available from various commercial sources. There are image processing, computational, database storage, and . data access advantages to having a regularized, encapsulating, triangular mesh representing the surface of a 3D object model. However, this is usually not how these models are stored. They can have too much detail in some areas, and not enough detail in others. They can have a mix of planar geometric primitives (triangles, quadrilaterals, n-sided polygons) representing not only the surface of the model, but also interior features. And the exterior mesh is usually not regularized nor encapsulating. This paper presents a method called SHRlNKWRAP which can be used to process 3D object models to achieve output models having the aforementioned desirable traits. The method works by collapsing an encapsulating sphere, which has a regularized triangular mesh on its surface, onto the surface of the model. A GUI has been developed to make it easy to leverage this capability. The SHRlNKWRAP processing chain and use of the GUI are described and illustrated.

97 MATHEMATICS AND COMPUTING↗

Knowledge-based low-level image analysis for computer vision systems

Two algorithms for entry-level image analysis and preliminary segmentation are proposed which are flexible enough to incorporate local properties of the image. The first algorithm involves pyramid-based multiresolution processing and a strategy to define and use interlevel and intralevel link strengths. The second algorithm, which is designed for selected window processing, extracts regions adaptively using local histograms. The preliminary segmentation and a set of features are employed as the input to an efficient rule-based low-level analysis system, resulting in suboptimal meaningful segmentation.

Dhawan, Atam P.↗

Volume of Lytic Vertebral Body Metastatic Disease Quantified Using Computed Tomography–Based Image Segmentation Predicts Fracture Risk After Spine Stereotactic Body Radiation Therapy

Purpose: To determine a threshold of vertebral body (VB) osteolytic or osteoblastic tumor involvement that would predict vertebral compression fracture (VCF) risk after stereotactic body radiation therapy (SBRT), using volumetric image-segmentation software. Methods and Materials: A computational semiautomated skeletal metastasis segmentation process refined in our laboratory was applied to the pretreatment planning CT scan of 100 vertebral segments in 55 patients treated with spine SBRT. Each VB was segmented and the percentage of lytic and/or blastic disease by volume determined. Results: The cumulative incidence of VCF at 3 and 12 months was 14.1% and 17.3%, respectively. The median follow-up was 7.3 months (range, 0.6-67.6 months). In all, 56% of segments were determined lytic, 23% blastic, and 21% mixed, according to clinical radiologic determination. Within these 3 clinical cohorts, the segmentation-determined mean percentages of lytic and blastic tumor were 8.9% and 6.0%, 0.2% and 26.9%, and 3.4% and 15.8% by volume, respectively. On the basis of the entire cohort (n=100), a significant association was observed for the osteolytic percentage measures and the occurrence of VCF (P<.001) but not for the osteoblastic measures. The most significant lytic disease threshold was observed at ≥11.6% (odds ratio 37.4, 95% confidence interval 9.4-148.9). On multivariable analysis, ≥11.6% lytic disease (P<.001), baseline VCF (P<.001), and SBRT with ≥20 Gy per fraction (P=.014) were predictive. Conclusions: Pretreatment lytic VB disease volumetric measures, independent of the blastic component, predict for SBRT-induced VCF. Larger-scale trials evaluating our software are planned to validate the results.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Texture functions in image analysis: A computationally efficient solution

A computationally efficient means for calculating texture measurements from digital images by use of the co-occurrence technique is presented. The calculation of the statistical descriptors of image texture and a solution that circumvents the need for calculating and storing a co-occurrence matrix are discussed. The results show that existing efficient algorithms for calculating sums, sums of squares, and cross products can be used to compute complex co-occurrence relationships directly from the digital image input.

Cox, S. C.↗

Spatial Modulation Improves Performance in CTIS

Suitably formulated spatial modulation of a scene imaged by a computed-tomography imaging spectrometer (CTIS) has been found to be useful as a means of improving the imaging performance of the CTIS. As used here, "spatial modulation" signifies the imposition of additional, artificial structure on a scene from within the CTIS optics. The basic principles of a CTIS were described in "Improvements in Computed- Tomography Imaging Spectrometry" (NPO-20561) NASA Tech Briefs, Vol. 24, No. 12 (December 2000), page 38 and "All-Reflective Computed-Tomography Imaging Spectrometers" (NPO-20836), NASA Tech Briefs, Vol. 26, No. 11 (November 2002), page 7a. To recapitulate: A CTIS offers capabilities for imaging a scene with spatial, spectral, and temporal resolution. The spectral disperser in a CTIS is a two-dimensional diffraction grating. It is positioned between two relay lenses (or on one of two relay mirrors) in a video imaging system. If the disperser were removed, the system would produce ordinary images of the scene in its field of view. In the presence of the grating, the image on the focal plane of the system contains both spectral and spatial information because the multiple diffraction orders of the grating give rise to multiple, spectrally dispersed images of the scene. By use of algorithms adapted from computed tomography, the image on the focal plane can be processed into an image cube a three-dimensional collection of data on the image intensity as a function of the two spatial dimensions (x and y) in the scene and of wavelength (lambda). Thus, both spectrally and spatially resolved information on the scene at a given instant of time can be obtained, without scanning, from a single snapshot; this is what makes the CTIS such a potentially powerful tool for spatially, spectrally, and temporally resolved imaging. A CTIS performs poorly in imaging some types of scenes in particular, scenes that contain little spatial or spectral variation. The computed spectra of such scenes tend to approximate correct values to within acceptably small errors near the edges of the field of view but to be poor approximations away from the edges. The additional structure imposed on a scene according to the present method enables the CTIS algorithms to reconstruct acceptable approximations of the spectral data throughout the scene.

Bearman, Gregory H.↗

Sci-Thur PM - Colourful Interactions: Highlights 06: Patient-specific calibration of cone-beam computed tomographic (CBCT) image sets for on-line dose tracking and plan assessment

Purpose: To develop a radiotherapy dose tracking and plan evaluation technique using cone-beam computed tomography (CBCT) images. Methods: We developed a patient-specific method of calibrating CBCT image sets for dose calculation. The planning CT was first registered with the CBCT using deformable image registration (DIR). A scatter plot was generated between the CT numbers of the planning CT and CBCT for each slice. The CBCT calibration curve was obtained by least-square fitting of the data, and applied to each CBCT slice. The calibrated CBCT was then merged with original planning CT to extend the small field of view of CBCT. Finally, the treatment plan was copied to the merged CT for dose tracking and plan evaluation. The proposed patient-specific calibration method was also compared to two methods proposed in literature. To evaluate the accuracy of each technique, 15 head-and-neck patients requiring plan adaptation were arbitrarily selected from our institution. The original plan was calculated on each method’s data set, including a second planning CT acquired within 48 hours of the CBCT (serving as gold standard). Clinically relevant dose metrics and 3D gamma analysis of dose distributions were compared between the different techniques. Results: Compared to the gold standard of using planning CTs, the patient-specific CBCT calibration method was shown to provide promising results with gamma pass rates above 95% and average dose metric agreement within 2.5%. Conclusions: The patient-specific CBCT calibration method could potentially be used for on-line dose tracking and plan evaluation, without requiring a re-planning CT session.

60 APPLIED LIFE SCIENCES↗

DREAMS and IMAGE: A Model and Computer Implementation for Concurrent, Life-Cycle Design of Complex Systems

Computing architectures are being assembled that extend concurrent engineering practices by providing more efficient execution and collaboration on distributed, heterogeneous computing networks. Built on the successes of initial architectures, requirements for a next-generation design computing infrastructure can be developed. These requirements concentrate on those needed by a designer in decision-making processes from product conception to recycling and can be categorized in two areas: design process and design information management. A designer both designs and executes design processes throughout design time to achieve better product and process capabilities while expanding fewer resources. In order to accomplish this, information, or more appropriately design knowledge, needs to be adequately managed during product and process decomposition as well as recomposition. A foundation has been laid that captures these requirements in a design architecture called DREAMS (Developing Robust Engineering Analysis Models and Specifications). In addition, a computing infrastructure, called IMAGE (Intelligent Multidisciplinary Aircraft Generation Environment), is being developed that satisfies design requirements defined in DREAMS and incorporates enabling computational technologies.

Hale, Mark A.↗

Quantum graph learning and algorithms applied in quantum computer sciences and image classification

Graph and network theory play a fundamental role in quantum computer sciences, including quantum information and computation. Random graphs and complex network theory are pivotal in predicting novel quantum phenomena, where entangled links are represented by edges. Quantum algorithms have been developed to enhance solutions for various network problems, giving rise to quantum graph computing and quantum graph learning (QGL). Here, in this review, we explore graph theory and graph learning methods as powerful tools for quantum computers to generate efficient solutions to problems beyond the reach of classical systems. We delve into the development of quantum complex network theory and its applications in quantum computation, materials discovery, and research. We also discuss quantum machine learning (QML) methodologies for effective image classification using qubits, quantum gates, and quantum circuits. Additionally, the paper addresses the challenges of QGL and algorithms, emphasizing the steps needed to develop flexible QGL solvers. This review presents a comprehensive overview of the fields of QGL and QML, highlights recent advancements, and identifies opportunities for future research.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Image

The computer side of the IMAGE project consists of a collection of Perl scripts that perform a variety of tasks; scripts are available to insert, update and delete data from the underlying Oracle database, download data from NCBI's Genbank and other sources, and generate data files for download by interested parties. Web scripts make up the tracking interface, and various tools available on the project web-site (image.llnl.gov) that provide a search interface to the database.

Marsh, Amber↗

Using X-Ray Computed Tomography to Image Apollo Drive Tube 73002

The Apollo missions collected 382 kg of rock, regolith, and core samples from six locations on the Moon. Although most Apollo samples are well characterized, several types of samples remain wholly or largely unstudied since their return: unopened and/or sealed drive tube samples, samples frozen upon return, and samples stored in a He-purged environment. NASA selected nine teams to participate in the Apollo Next Generation Sample Analysis (ANGSA) Program to study representative samples from each of these categories. The first sample studied as part of the ANGSA program is drive tube 73002, a 4 cm diameter unopened (but unsealed) drive tube collected on a landslide deposit near Lara Crater at the Apollo 17 landing site. It was part of a ~60 cm long double drive tube, and the bottom half of the tube (73001)was sealed under vacuum on the Moon (and will be studied next). As part of the preliminary examination of sample 73002, the entire drive tube was imaged with a high resolution X-ray Computed Tomography (XCT) scan prior to opening and dissecting the sample. Additionally, >50 XCT scans have been made of “large” clasts (>4 mm) removed from the core as part of the ongoing dissection process. Here we will present both the whole drive tube XCT data showing the overall structure of sample 73002 prior to dissection, as well as XCT scans of individual clasts that reveal the types and abundance of different lithologies present within the drive tube. We will also discuss the utility of the scans as part of the curation and preliminary examination process, as well as the potential for future science returns from the XCT scans.

Ryan A Zeigler↗

Using X-Ray Computed Tomography to Image Apollo Drive Tube 73002

The Apollo missions collected 382 kg of rock, regolith, and core samples from six locations on the nearside of the Moon. Today, just over 84% by mass of the Apollo collection remains in pristine condition within the curation facility at Johnson Space Center. Most Apollo samples have been well characterized, however there are several types of samples that have remained wholly or largely unstudied since their return, and/or that have been curated under special conditions. These sample types are: (1) unopened samples sealed under vacuum on the Moon; (2) unopened (but unsealed) drive tubes; (3) Apollo 17 samples frozen shortly after their return; and (4) Apollo 15 samples opened and stored in a helium atmosphere since their return. NASA solicited proposals for the Apollo Next Generation Sample Analysis Program (ANGSA), and 9 teams were selected to study: (1) unsealed, unopened drive tube 73002; (2) sealed, unopened drive tube 73001 (paired with 73002); and (3) a subset of the frozen and He-purged samples [1]. The first sample opened as part of the ANGSA program was drive tube 73002. This was originally a ~30 cm long, 4 cm diameter drive tube collected on a landslide deposit near Lara Crater at the Apollo 17 landing site. It was part of a ~60 cm long double drive tube collected, and the bottom half of the tube (73001) was sealed under vacuum on the Moon [2]. Prior to opening sample 73002, the sample was imaged with a high resolution X-ray Computed Tomography (XCT) scan of the entire tube. Additional XCT scans have been made of “large” clasts removed from the core as part of the dissection process [3]. Here we present the whole tube and close-up XCT data from 73002, and talk about the utility of the scans as part of the curation process, including the potential for future science returns from the high resolutions scans.

R A Zeigler↗

A comparison of digitally simulated holographic images with actual holographic images

In making digitally generated holograms the digital computer and its associated plotting equipment degrade the quality of the hologram. It is necessary then to study the computer generated hologram in terms of these degradations. A computer simulated optical processor allows the results to be observed via computer simulated images. This research reports a method for optimizing the computer image reconstruction and compares these images with optically produced holographic images. The versatility of the simulated optical processor is illustrated by several spatial filtering and hologram reconstructions.

Calhoun, M. D.↗

Material Characterization and Geometric Segmentation of a Composite Structure Using Microfocus X-Ray Computed Tomography Image-Based Finite Element Modeling

This study utilizes microfocus x-ray computed tomography (CT) slice sets to model and characterize the damage locations and sizes in thermal protection system materials that underwent impact testing. ScanIP/FE software is used to visualize and process the slice sets, followed by mesh generation on the segmented volumetric rendering. Then, the local stress fields around several of the damaged regions are calculated for realistic mission profiles that subject the sample to extreme temperature and other severe environmental conditions. The resulting stress fields are used to quantify damage severity and make an assessment as to whether damage that did not penetrate to the base material can still result in catastrophic failure of the structure. It is expected that this study will demonstrate that finite element modeling based on an accurate three-dimensional rendered model from a series of CT slices is an essential tool to quantify the internal macroscopic defects and damage of a complex system made out of thermal protection material. Results obtained showing details of segmented images; three-dimensional volume-rendered models, finite element meshes generated, and the resulting thermomechanical stress state due to impact loading for the material are presented and discussed. Further, this study is conducted to exhibit certain high-caliber capabilities that the nondestructive evaluation (NDE) group at NASA Glenn Research Center can offer to assist in assessing the structural durability of such highly specialized materials so improvements in their performance and capacities to handle harsh operating conditions can be made.

Abdul-Aziz, Ali↗