Search NASA⌕ Search

SEARCH · Search NASA

Results for “Cooling Load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

The evolving role of geothermal energy for decarbonizing the United States

Geothermal energy is often referred to as a niche technology that is too localized, too small or too expensive to make much of a difference in how renewable energy will be supplied in a fully decarbonized future. As a result, geothermal energy has been undervalued in terms of what it could provide to complement, rather than compete with, electricity generation from wind, solar photovoltaic, concentrating solar power and other renewables. Geothermal energy systems are fully dispatchable and can provide baseload or load-following electric power or heat suitable for a wide range of applications including supplying district heating for communities and cities, and heating and cooling of individual buildings. The focus of our study is on the potential of utilizing geothermal energy for providing heat for buildings and industry at lower temperatures, a substitute for the combustion of fossil fuels. Because heating represents about 20% (20 EJ per year) of the annual primary energy consumption in the U.S.—with most of it coming from burning natural gas, oil and/or propane in furnaces—deploying geothermal heating on a national scale could have a significant impact on lowering carbon emissions. In heating-dominated states in the U.S. Northern Tier, heating often is among the largest contributors to the state's carbon footprint. This review begins with a discussion of the motivation and rationale behind considering geothermal as a key low-carbon heating option for the U.S. The study summarizes the U.S. geothermal resource and describes the applications and main engineering components of using geothermal energy for heating and cooling, electric power generation, and co-generation using district heating, geothermal heat pumps, and power conversion with steam flashing and organic Rankine plants. Environmental benefits and impacts are described. An extensive discussion of geologic and thermal-hydraulic aspects of the subsurface is included in the review because of their critical role in determining reservoir designs at specific sites to ensure sufficient productivity that is both safe and economically viable. Models for estimating levelized costs of district heating are used to show how costs are affected by reservoir performance, infrastructure capital costs, and financial parameters. Here, the review concludes with an assessment of technical subsurface issues associated with reservoir performance and the economic requirements for providing geothermal heating in district heating systems at a sufficient scale to have an impact on decarbonizing the U.S.

15 GEOTHERMAL ENERGY↗

Material effects on dynamics in triple-nozzle gas-puff Z pinches

Here, the gas-puff Z pinch has a long history with myriad applications as an efficient neutron or x-ray source. Its simplicity as a load configuration makes it suitable for studying fundamental plasma physics phenomena such as instabilities and energy transport. For example, the implosion of cylindrical shells onto a fusion fuel are inherently susceptible to instability growth on their external surfaces; if such instabilities are unmitigated, then the consequences in terms of degraded performance can be substantial. Similarly, mitigating heat transport from a hot fuel to its colder surrounding container can make fusion conditions more easily achievable. Here we have conducted a systematic study of triple-nozzle (outer liner, inner liner, fuel) gas puffs using two-dimensional (2D) magnetohydrodynamic simulations to investigate the effect of load material on the relevant dynamics. Analogous to past studies on spherical blast waves and converging shock waves, a trend emerges linking increased radiative cooling, lower adiabatic index, and increased magneto-Rayleigh-Taylor instability growth. Notably, our results suggest that, for the present configuration, Ar radiates less than both Ne and Kr during the early stages of the implosion while mass is being swept up and perturbations begin to seed instability growth. Consequently, pinches with Ar on the outer surface exhibit more stable 2D behavior. Here we also present a parameter scan of thermonuclear neutron yield, Y, as a function of peak current, I pk and dopant concentration with Ne or Ar, depending on the inner liner material. Above 6 MA, our results suggest Y ∝ $I$$^{5}_{pk}$ and even substantial mixing (10% by volume) of Ne into the fuel does not drastically reduce yield, suggesting an Ar/Ne/fuel configuration may reliably achieve DD thermonuclear yields of 10 13 – 10 14 /cm in the 10–20 MA range.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Techno-Economic Analysis of a Nuclear Reactor System coupled with a Liquid Metal Battery

There is a need for nuclear reactor systems to become more dynamic as defossilization and renewable energy sources continue to reshape the energy grid. One option to meet these changing demands is to pair the reactor with an energy storage system. This work details a technoeconomic analysis and sensitivity analysis of a high temperature gas cooled microreactor, supercritical carbon dioxide power cycle, and liquid metal battery. Dynamic modeling has shown that these three systems compliment each other to provide load following and black-start capabilities to the grid. Current cost estimates for installing the systems yield a competitive levelized cost of electricity and levelized cost of storage, indicating that such a combined system may be economically viable as technological advances lead to them being technically feasible.

25 ENERGY STORAGE↗

Multi-Physics System-level Simulations of a Generic Pebble Bed High-Temperature Gas Cooled Reactor with Coupled SAM/Griffin Model

A SAM model for a 200 MWth generic pebble bed high-temperature gas-cooled reactor (PBHTGR) is presented in this work. As an extension to the modeling effort from FY-22 (Ooi et al. (2022)), an improved core channel approach is used to model the pebble bed of the reactor. The improvement greatly simplifies the model and reduces the run time of the model. Furthermore, the SAM model is coupled to the Griffin reactor physics model from Stewart et al. (2021) using the MOOSE MultiApp system where neutronics calculations are performed by the Griffin model and thermal hydraulics calculations by the SAM model. Favorable predictions are produced by the SAM/Griffin coupled model for steady-state normal operating condition. A load-following transient is also simulated with the coupled model where the neutronics and thermal hydraulics responses of the core are predicted correctly by the model. A protected Pressurized Loss of Forced Cooling (PLOFC) accident is simulated with the SAM model, in which the reactor power is determined using the decay heat curve, and therefore the Griffin model is not needed and thus decoupled. A simplified RCCS (Reactor Cavity Cooling System) loop is added to the model to remove decay heat from the core during the transient. Qualitatively, the prediction by the SAM model matches the expected behavior of a PB-HTGR during a PLOFC accident.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Dynamic Thermal Performance Analysis of PCM Products Used for Energy Efficiency and Internal Climate Control in Buildings

PCMs are attractive for the future generation of buildings, where energy efficiency targets and thermal comfort expectations are increasingly prioritized. Experimental analysis of local thermal processes in these dynamic components and whole-building energy consumption predictions are essential for the proper implementation of PCMs in buildings. This paper discusses the experimental analysis of the thermophysical characteristics of both a latent heat storage material (PCM) and a product containing this PCM. The prototype product under investigation is a panelized PCM technology containing inorganic, salt-hydrate-based PCM. The thermal analysis includes studies of melting and freezing temperatures, enthalpy changes during phase change processes, nucleation intensity, sub-cooling effects, and PCM stability. The PCM’s stability is also investigated, as is the ability of PCM products to control local temperatures and peak load transmission times. Two inorganic PCM formulations based on calcium chloride hexahydrate (CaCl 2 .6H 2 O) were prepared and tested in laboratory conditions. Material-scale testing results were compared with outcomes from the system-scale analysis, using both laboratory test methods as well as field exposure in test huts. This work demonstrates that PCM technologies used in buildings can effectively control both the magnitude of thermal storage capacity as well as the time of the peak thermal load. It was found that commonly used material-scale testing methods may not always be beneficial in assessing the dynamic thermal performance characteristics of building technologies containing PCMs.

42 ENGINEERING↗

Peak Power Minimization for Commercial Thermostatically Controlled Loads in Multi-Unit Grid-Interactive Efficient Buildings

The load profiles of most commercial and industrial consumers are characterized by brief periods of very high power consumption followed by intervals of lower demand. To encourage such consumers to flatten their load profiles, power utilities in and around the world often levy a monthly demand charge (DC) on the peak demand measured over brief intervals. In this work, we consider the joint optimization of energy costs (EC) and the instantaneous peak power of a multi-unit building which uses a hydronic heating, ventilation and cooling (HVAC) system and responds to a demand response (DR) program. Despite the non-linear structure of the problem, we show how optimal solutions can be obtained efficiently using linear programming. Next, we study the power demand patterns resulting from our proposed strategy for thermostatically controlled loads (TCLs), and evaluate the strategy’s performance for various climate zones in the US, under both typical and atypical weather conditions. Finally, the results show that depending on the ambient conditions and the tariff structure, our strategy can result in utility bill savings of up to nearly 19% compared to the baseline. The results also indicate that our power control strategy can significantly reduce the instantaneous peak power consumption in commercial TCLs.

HVAC↗

Multi-cycle reload analysis of a long cycle gas-cooled fast modular reactor

There is currently significant interest in deploying HALEU-fueled fast reactors, including the General Atomics (GA) Fast Modular Reactor (FMR). Such reactors can achieve very long fuel cycles, but with multi-batch loading will take decades to reach equilibrium. This motivates design and analysis of both the initial core and multi-cycle reload, which is typically performed using fast-running, deterministic fast reactor codes such as the Argonne Reactor Computation (ARC) codes. In this paper, multicycle reload of the GA FMR is analyzed using the ARC codes. The GA FMR utilizes 19.75 % enriched fuel in a 16 year cycle with a three-batch strategy, with twice-burned fuel placed on the core periphery. The GA FMR has a softened neutron spectrum due to reflecting elements in the core, so the neutronic solution is first benchmarked against the OpenMC Monte Carlo code. Discrepancy on k eff is 400–600 pcm, likely due to the softened neutron spectrum, heterogeneous fuel assembly design and central reflector. However, the rms discrepancy on the assembly power distribution is only 0.6 %, despite the presence of the central reflector. A reload strategy is devised for the first three cycles of such a reactor, ultimately spanning the first 45–48 years of its operation. The fresh core uses 19.75 %, 19.25 % and 16.75 % enriched fuel in place of fresh, once-burned and twice-burned and is then subsequently refueled with only 19.75 % enriched fuel. The cycle length is varied over 3 cycles of operation to balance fuel utilization and reactor availability, specifically with use of an extended 18-year Cycle 1, followed by a shortened 11-year Cycle 2. Cycle 3 is close to the target 16-year length. Finally, placing twice burned assemblies next to the GA FMR central reflector can reduce power peaking by 3 %, at the expense of slightly reducing the cycle length.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Assessing concurrent effects of climate change on hydropower supply, electricity demand, and greenhouse gas emissions in the Upper Yangtze River Basin of China

Hydropower importantly provides flexible low-carbon electricity, however, climate change will affect the hydropower system through altering hydrologic regimes while also affecting electricity demands for heating and cooling that hydropower resources serve. This study assesses the effect of climate change on hydropower and electricity demand in the Upper Yangtze River Basin (UYRB) in China on the regional net electric load and greenhouse gas (GHG) emissions. This is accomplished by using climate projections from five global climate models (GCMs) to simultaneously force (1) a physically-based hydrological model and a statistically-based hydropower model to estimate the future generating capacity of 21 large hydropower plants in the UYRB and (2) an empirical electricity demand model accounting for socioeconomic and climatic factors. Under climate change, the projected hydropower generation in the UYRB tends to increase in the 21st century but is far less than the increase in electricity demand, increasing the gap between demand and supply. Future increases in overall electricity demand are driven by GDP growth, but climate change will alter the distribution of the seasonal electricity demand. Climate warming decreases electricity demand for heating in winter and increases electricity demand for cooling in summer, but ultimately increases demand. Meanwhile, there is an increasing mismatch between electricity demand and hydropower supply associated with inter- and intra-annual variations, owing to the temporal climate change and increase in compound climate extremes (droughts and heatwaves). Finally, meeting the gap between supply and demand due to climate change is estimated to contribute 79.0–184.6 and 50.6–316.2 MMT CO 2e /yr of additional GHG emissions by the mid and end of 21st century, respectively.

13 HYDRO ENERGY↗

ITER ECH Transmission Line System Design and Status

The electron cyclotron (EC) heating & current drive (H&CD) system on ITER provides plasma heating by generating, transmitting, and launching high-intensity, high-frequency (170 GHz) electromagnetic wave energy steerable across the plasma cross-section. The transmission line (TL) subsystem connects the Matching Optics Unit (MOU) on each of the 24 gyrotrons to the 32 feed points in the four upper launchers and the 24 feed points in the equatorial launcher. Each TL must be able to operate at up to 1.2 MW of input power for up to 1 hour pulse lengths. The TL system contains 50 mm water-cooled corrugated waveguide, 90o miter bends, 140o miter bends, polarizer miter bend pairs, switches, expansion units, pumpouts, DC breaks, MOU-TL adapters, Radio Frequency (RF) loads, and isolation shutter valves. A detailed finite element analysis has been used to verify the thermo-mechanical performance of each component. The microwave performance has been analyzed using a 2-D electromagnetic code combined with a Monte Carlo code. This approach allows the impact of manufacturing and installation tolerances to be assessed and optimized to provide a high probability of achieving the system performance requirements. Prototypes of the waveguide and TL components have been fabricated and tested at high-power. Production contracts are now being issued for fabrication and delivery of the waveguide and components to ITER.

Hanson, Gregory↗

Groundwater Inflows to the Columbia River Along the Hanford Reach and Associated Nitrate Concentrations

Healthy river ecosystems require the interaction of many physical and biological processes to maintain their status. One physical process supporting biogeochemical cycling is hydrologic exchange (i.e., hydrologic exchange flows, HEFs) between relatively fast-flowing channel waters and slower-flowing surface and subsurface waters (lateral and vertical). Land uses adjacent to rivers have the potential to alter the water quality of off-channel surface and subsurface waters, and HEFs therefore have the potential to deliver solutes associated with river-adjacent land uses to rivers. HEFs can be nonpoint, diffuse sources of pollution, making the ultimate pollution source difficult to identify, especially in large rivers. Here, we seek to identify HEFs in the Columbia River near Richland, WA by looking for anomalies in temperature and electrical conductivity (EC) along the bed of the river in February, June, July, August, and November 2018. These are ultimately the “ends” of HEFs as they are locations of subsurface inflow to the river. We found these anomalies to be a combination of warmer or colder and higher (but not lower) EC than river water. We identified a majority of warm anomalies in February and July 2018, and majority cold anomalies in June, August, and November 2018. High-EC anomalies were found mostly in February, August, and November. Combined, we observe a shift from warm, high EC anomalies dominating in February to equivalent EC, warm anomalies in June, to equivalent EC, cool anomalies dominating July. In August, we also measured dissolved nitrate ($NO^-_3$) in-situ to determine whether anomalies were associated with increased $NO^-_3$ loading to the river, especially along the eastern shoreline, which is dominated by agricultural land use. Inflows along the eastern shoreline have greater concentrations of nitrate than river water (up to 10 mg $N–NO^-_3$/L). This research demonstrates that HEFs are temporally and spatially dynamic transferring heat and solutes to rivers.

54 ENVIRONMENTAL SCIENCES↗

3D Printable Polymers for Radiological Applications

Additive manufacturing of polymers is a widely used and growing technology throughout the DOE complex. Composite filaments for Fused Deposition Modeling (FDM) printers are commonly used to enhance material properties such as mechanical strength, operating temperature and chemical resistance. Radio luminescent properties were added to 3D filaments by impregnating clear poly(ethylene terephthalate)-glycol (PETG) with X-ray scintillator powder. X-ray scintillators have unique, narrow emission spectra which can be imaged with low light DSLR cameras, photomultiplier tubes, or spectrometers. Filament Production: 1. Pellets are loaded into the hopper. 2. Temperature and extrusion speed are set on extruder. 3. Extruder turned on and filament is pulled from nozzle along air path to cool. 4. Spooler drive speeds set. 5. Filament is inserted through Filameasure then guided along drive wheels and into traverse. 6. Parameters adjusted to obtain 1.75 mm diameter 7. Filament is inserted into spooler wheel. Traverse speed set and slip nut adjusted to make tight and even roll. From Raw Materials to Printed Part: Clear PETG pellets were dipped in ZnS:Cu scintillator powder to coat pellets. Coated and uncoated pellets were mixed together before inserting into hopper. Filament showed trace amounts of powder and luminesced under UV light. Powder distribution is random and not reproducible thus providing a unique identification marker potentially useful for national security applications. Multiple X-ray scintillators can be arranged in a panel to discriminate incident X-ray photon energies. Variable panel arrangement: pixelated, layered, solid from homogenous filament. Ratio of emission intensities. Response varies with incident photon energy. Spectrally separate scintillators. Scintillators: Yttrium Oxide Europium Doped - Red, Gadolinium Oxysulfide Terbium Doped - Green, Barium Magnesium Aluminate Europium Doped - Blue, Zinc Sulfide Copper Doped - Green. Powder concentrations will need to be increased in the filament for use in the energy discriminating panel. Homogeneity in the filament will be a challenge that can be solved by turning the pellets into a powder and mixing it with scintillator powder prior to extrusion. The panels will be tested using x-ray booths and button sources such as Am-241, Cs-137, and Co-60.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Cooling Egypt: Cost and benefits of room air conditioner efficiency improvement in Egypt

Egypt is one of the largest countries in the Middle East and North Africa region with a population of a total of 106 million (as of July 2022). Increasing urbanization, population growth, and increasing temperatures will likely continue to drive demand for electricity from air conditioning, with corresponding negative impacts on the peak load, air quality, and greenhouse gas emissions from refrigerant use and energy consumption. Since 2003, Egypt has adopted a standards and labeling program for various appliances, and has improved its room air conditioner (RAC) energy efficiency requirements in 2016 and 2017. However, its market is still dominated by inefficient fixed-speed drive (FSD) RACs due to a price-sensitive market. Seasonal metrics such as Cooling Season Performance Factor (CSPF) measure the energy efficiency of FSD and variable-speed drive (VSD) RACs on the same scale. Leading markets, most notably China, have already adopted a new MEPS in 2020 and 2022, which align largely with the United for Efficiency (U4E) Model Regulations Guidelines. India has also adopted a CSPF metric. Both India and China are now experiencing (1) increased demand and consumption of higher efficiency VSD RACs, as well as (2) a corresponding drop in prices from the economies of scale of production of these higher efficiency RACs. Because China is a leading manufacturer in the global air conditioner (AC) market, its adoption of the model U4E regulations have effectively raised the energy efficiency of the ACs in the global market. To achieve the benefits of taking a similar approach to Egypt’s market, we offer the following recommendations: 1. Adopt a common metric to measure the efficiency of both FSD and VSD RACs 2. Raise the stringency of MEPS to the level of the U4E Model Regulation Guidelines 3. Restructure the labeling program from the “A++” labeling scheme to a simpler A through E or a star-rating program 4. Strengthen the compliance regime governing the Egyptian AC MEPS 5. Assist small and medium AC manufacturers in Egypt to transition manufacturing lines to produce low-cost, high-efficiency VSD RACs. Adopting these recommendations would reduce Egypt’s electricity consumption to 11 TWh in 2030 and 89 TWh in 2050—with corresponding carbon dioxide (CO2) emissions reductions and avoided generation capacity requirements compared to the baseline.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Best Practices for Shielding Analyses of Activated Metals and Spent Resins from Reactor Operation

This report investigated best practices for performing shielding evaluations of Type B waste packages, as defined in 10 CFR Part 71 regulations on packaging and transportation of radioactive material, or packages for which the contents are not defined before loading and may include a broad range of nuclides, geometries, and non-fuel materials. The following non-fuel waste streams were analyzed: Activated metals from decommissioned commercial power reactors, including Type 304 stainless steel, reactor vessel steel, and Inconel, Control blades from boiling water reactors, Neutron-activated corrosion products on surfaces of activated metals, and Spent resins from power plant operations. Measured elemental compositions, including major constituents and impurities, for steel and Inconel samples from commercial power reactors were used in activation calculations to determine radionuclide inventories in activated metals. For a simplified cask model, 60 Co contribution to the total external package dose rate at 30 days after shutdown varied from approximately 60% to 95%, depending on the activated metal, initial cobalt impurity concentration in the metal, and the thickness of the overpack gamma shield. Its maximum contribution to the total external package dose rate of approximately 100% was reached within the time interval of 2 to 5 years after shutdown and was maintained for up to 45 to 60 years after shutdown, depending on material, initial cobalt impurity concentration, and shield thickness. Thereafter, the 60 Co contribution to external package dose rate decreased with increasing decay time. Cobalt-60 is primarily produced by neutron reactions with the cobalt impurity in steel and Inconel. Other important radionuclides in activated metals contributing to package external dose rate are radionuclides with relatively short decay times, including 51 Cr, 59 Fe, 58 Co, and 54 Mn. These radionuclides may be represented as an equivalent 60 Co activity/source because 60 Co gamma ray emissions are bounding in terms of source strength and energy to other important radionuclides identified in the analyzed activated metals. Approaches for modeling the neutron-activated corrosion products that may be attached to activated reactor components were analyzed in this report. It was demonstrated that a surface source is more conservative than a uniform volumetric source for the treatment of neutron-activated corrosion products with respect to external package dose rates. An analysis of the maximum radionuclide loadings reported on spent resins identified the radionuclides 137 Cs, 60 Co, 134 Cs, 65 Zn, and 58 Co as the primary contributors to external package dose rate. For a resin cooled for 3.08 years, the external package dose rate was entirely produced by the reported 137 Cs and 60 Co inventory. The neutron sources from actinides found on spent resins or activated metals produced negligible dose rates and may be ignored in dose rate analyses. Effects of idealized waste material, source geometry, and spatial material/source distributions on external package dose rates were determined based on dose rate results for a simplified cask model under normal conditions of transport. Type 304 stainless steel, zirconium, and aluminum with adjusted mass densities based on a maximum content weight were analyzed for material modeling effects on external package dose rate. These materials produced identical external package dose rates within the statistical uncertainties of the dose rate estimates. Among four different source geometry configurations with homogeneous material of different mass densities, uniform volumetric source distribution, and the same source strength, the geometry configuration with lowest mass density (i.e., minimum self-shielding effect among the four cases) was most conservative. Spatial source distributions that better represent localized peak 60 Co activity values were more conservative than a uniform volumetric source distribution, assuming the same weight and total source strength per package. The increase in external dose rate caused by localized source peaks can be as much as the ratio between source peak activity density to average activity density, depending on the location of the activated metal with peak activity density. Therefore, the shielding analysis may be simplified if localized peak activities and the average activity per package can be measured/determined and documented at the time of cask loading. For simplicity, external package dose rates may be determined based on average source activity and a uniform volumetric source distribution. The dose rate results from that calculation model multiplied by the ratio of peak activity density to average activity density will produce maximum dose rate values for conservative estimates.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Preliminary Investigation on the Performance of a Dual-Source Heat Pump using both the Air and the Ground

Air source heat pumps (ASHPs) and ground source heat pumps (GSHPs) are the two most common types of electric-driven heat pumps in the marketplace to replace fossil fuel-based heating systems. However, the performance and efficiency of ASHPs depend on the ambient air conditions. Therefore, ASHPs usually are equipped with electric resistance heaters to provide supplemental heating when the ambient temperature is low, and the heating demand is high. The electric resistance heaters could result in high power draws when they are turned on. On the other hand, due to the relatively steady temperature of the ground, GSHPs are more energy efficient than ASHPs when providing space heating and cooling to the buildings. However, the adoption of GSHP is hindered by its high initial cost, mostly due to the cost of drilling boreholes for installing ground heat exchangers (GHE). To solve the above issues, our study investigates the performance of dual-source heat pumps (DSHPs) with respect to that of ASHPs and GSHPs. The DSHP will use ambient air when its temperature is favorable for the efficient operation of the heat pump. When the ambient temperature is too hot or too cold, the ground source will be utilized to retain the high-efficiency operation of the heat pump. Because the cumulative thermal load of the GHE is shared with the ambient air, the size of the GHE could be smaller than those of the conventional GSHPs. The study will model the DSHP and simulate its performance in providing heating and cooling for a typical single-family house in regions with hot, mild, or cold climates. In addition, the required GHE size of the DSHP system will be determined through annual simulations and compared with that of conventional GSHPs.

Anees, Fady↗

Collective Thomson scattering measurement of plasma evolution during the current pulse in a laser-triggered switch

High-voltage laser-triggered switches (HV-LTSs) are used in pulsed-power applications where low jitter and precise timing are required. The switches allow operation in the megaampere, megavolt regime while maintaining low insertion losses. Currently, there is a lack of detailed plasma measurements in these switches, yet such measurements are needed to elucidate the detailed physics, which include a range of processes such as laser breakdown, streamer formation and growth, current flow, plasma evolution, and cooling. Detailed spatially- and temporally resolved measurements of plasma properties within the switches could contribute to validating and advancing numeric models of these systems. This contribution presents laser Thomson scattering measurements of the electron number density and temperature evolution in a HV-LTS. The switch was operated at 6 kV with current flow for a duration of 145 ns and a peak current density of 0.2 MA/cm2 into a matched load. The Thomson scattering diagnostic system uses a 532 nm probe from an Nd:YAG laser allowing a temporal resolution of ∼10 ns. We find that during the switch current pulse, the plasma electron temperature rose from a starting value of 8.1 ± 1.6 eV (due to cooling of the earlier trigger laser plasma) to a peak value of 26 ± 5 eV with an associated increase in the electron density from 8.6 ± 1.7 × 1017 to 3.1 ± 0.6 × 1018 cm−3.

Gottfried, Jacob A. (ORCID:0000000290058841)↗

Dust-planetary boundary layer interactions amplified by entrainment and advections

Mineral dust contributes to more than half of the global aerosol loading. However, the radiative impacts of dust aerosols on planetary boundary layer (PBL) structure have not been explored sufficiently. During a typical dust storm event over Tarim Basin, dust aerosols exhibit a well-mixed distribution during the daytime in spite of a shallow layer of dust particles accumulated at higher altitudes. By contrast, nocturnal dust plumes are located near the surface due to stable stratification. We demonstrate that these differentiated vertical distributions determine the spatial heterogeneity of dust loading, radiative fluxes and PBL height variations. Dust aerosols cause daytime PBL suppression and nighttime PBL promotion through modulating surface and atmospheric radiative budgets. Specifically, dust-induced cooling effect within PBL directly inhibits the daytime PBL development. PBL suppression effect is then amplified by entrainment processes resulting in excessively low PBL height, especially for dust particles below but near the PBL top. Dust plumes weaken updrafts from PBL and downdrafts of the free atmosphere, which further reduce the entrainment mixing through attenuating horizontal and vertical advection, and eventually amplify PBL suppression. At night, near-surface dust aerosols stimulate a warm and unstable lower atmosphere, generate warm advection heating and promote the PBL development. Our study highlights the importance of specifying entrainment parameters and nighttime advection activities in quantifying the dust-PBL interactions.

54 ENVIRONMENTAL SCIENCES↗

Potential of Utilizing Thermal Energy Storage Integrated Ground Source Heat Pump System to Reshape Electricity Demand in the United States

Each year, more than 20% of electricity generated in the United States is consumed for meeting the thermal demands (e.g., space cooling, space heating, and water heating) in residential and commercial buildings. Integrating thermal energy storage (TES) with building’s HVAC systems has the potential to reshape the electric load profile of the building and mitigate the mismatch between the renewable generation and the demand of buildings. A novel ground source heat pump (GSHP) system integrated with underground thermal energy storage (UTES) has been proposed to level the electric demand of buildings while still satisfying their thermal demands. This study assessed the potential impacts of the proposed system with a bottom-up approach. The impacts on the electricity demand in various electricity markets were quantified. The results show that, within the capacity of the existing electric grids, the maximum penetration rate of the proposed system in different wholesale markets could range from 51% to 100%. Altogether, about 46 million single-family detached houses can be retrofitted into the proposed system without increasing the annual peak demand of the corresponding markets. By implementing the proposed system at its maximum penetration rate, the grid-level summer peak demand can be reduced by 9.1% to 18.2%. Meanwhile, at the grid level, the annual electricity consumption would change by –12% to 2%. The nationwide total electricity consumption would be reduced by 9%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗