Search NASA⌕ Search

SEARCH · Search NASA

Results for “Corrected equation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Simple Two-Dimensional Corrections for One-Dimensional Pulse Tube Models

One-dimensional oscillating flow models are very useful for designing pulse tubes. They are simple to use, not computationally intensive, and the physical relationship between temperature, pressure and mass flow are easy to understand when used in conjunction with phasor diagrams. They do not possess, however, the ability to directly calculate thermal and momentum diffusion in the direction transverse to the oscillating flow. To account for transverse effects, lumped parameter corrections, which are obtained though experiment, must be used. Or two-dimensional solutions of the differential fluid equations must be obtained. A linear two-dimensional solution to the fluid equations has been obtained. The solution provides lumped parameter corrections for one-dimensional models. The model accounts for heat transfer and shear flow between the gas and the tube. The complex Nusselt number and complex shear wall are useful in describing these corrections, with phase relations and amplitudes scaled with the Prandtl and Valensi numbers. The calculated ratio, a, between a two-dimensional solution of the oscillating temperature and velocity and a one-dimensional solution for the same shows a scales linearly with Va for Va less than 30. In this region alpha less than 0.5, that is, the enthalpy flow calculated with a two-dimensional model is 50% of a calculation using a one-dimensional model. For Va greater than 250, alpha = 0.8, showing that diffusion is still important even when it is confined to a thing layer near the tube wall.

Lee, J. M.↗

Computational Analyses in Support of Sub-scale Diffuser Testing for the A-3 Facility: Steady Predictions - Part 1

Simulation technology can play an important role in rocket engine test facility design and development by assessing risks, providing analysis of dynamic pressure and thermal loads, identifying failure modes and predicting anomalous behavior of critical systems. Advanced numerical tools assume greater significance in supporting testing and design of high altitude testing facilities and plume induced testing environments of high thrust engines because of the greater inter-dependence and synergy in the functioning of the different sub-systems. This is especially true for facilities such as the proposed A-3 facility at NASA SSC because of a challenging operating envelope linked to variable throttle conditions at relatively low chamber pressures. Facility designs in this case will require a complex network of diffuser ducts, steam ejector trains, fast operating valves, cooling water systems and flow diverters that need to be characterized for steady state performance. In this paper, we will demonstrate with the use of CFD analyses s advanced capability to evaluate supersonic diffuser and steam ejector performance in a sub-scale A-3 facility at NASA Stennis Space Center (SSC) where extensive testing was performed. Furthermore, the focus in this paper relates to modeling of critical sub-systems and components used in facilities such as the A-3 facility. The work here will address deficiencies in empirical models and current CFD analyses that are used for design of supersonic diffusers/turning vanes/ejectors as well as analyses for confined plumes and venting processes. The primary areas that will be addressed are: (1) supersonic diffuser performance including analyses of thermal loads (2) accurate shock capturing in the diffuser duct; (3) effect of turning duct on the performance of the facility (4) prediction of mass flow rates and performance classification for steam ejectors (5) comparisons with test data from sub-scale diffuser testing and assessment of confidence levels in CFD based flowpath modeling of the facility. The analyses tools used here expand on the multi-element unstructured CFD which has been tailored and validated for impingement dynamics of dry plumes, complex valve/feed systems, and high pressure propellant delivery systems used in engine and component test stands at NASA SSC. The analyses performed in the evaluation of the sub-scale diffuser facility explored several important factors that influence modeling and understanding of facility operation such as (a) importance of modeling the facility with Real Gas approximation, (b) approximating the cluster of steam ejector nozzles as a single annular nozzle, (c) existence of mixed subsonic/supersonic flow downstream of the turning duct, and (d) inadequacy of two-equation turbulence models in predicting the correct pressurization in the turning duct and expansion of the second stage steam ejectors. The procedure used for modeling the facility was as follows: (i) The engine, test cell and first stage ejectors were simulated with an axisymmetric approximation (ii) the turning duct, second stage ejectors and the piping downstream of the second stage ejectors were analyzed with a three-dimensional simulation utilizing a half-plane symmetry approximation. The solution i.e. primitive variables such as pressure, velocity components, temperature and turbulence quantities were passed from the first computational domain and specified as a supersonic boundary condition for the second simulation. (iii) The third domain comprised of the exit diffuser and the region in the vicinity of the facility (primary included to get the correct shock structure at the exit of the facility and entrainment characteristics). The first set of simulations comprising the engine, test cell and first stage ejectors was carried out both as a turbulent real gas calculation as well as a turbulent perfect gas calculation. A comparison for the two cases (Real Turbulent and Perfect gas turbulent) of the Ma Number distribution and temperature distributions are shown in Figures 1 and 2 respectively. The Mach Number distribution shows small yet distinct differences between the two cases such as locations of shocks/shock reflections and a slightly different impingement point on the wall of the diffuser from the expansion at the exit of the nozzle. Similarly the temperature distribution indicates different flow recirculation patterns in the test cell. Both cases capture all the essential flow phenomena such as the shock-boundary layer interaction, plume expansion, expansion of the first stage ejectors, mixing between the engine plume and the first stage ejector flow and pressurization due to the first stage ejectors. The final paper will discuss thermal loads on the walls of the diffuser and cooling mechanisms investigated.

Allgood, Daniel C.↗

Computational Analyses in Support of Sub-scale Diffuser Testing for the A-3 Facility: Steady Predictions - Part 1

Simulation technology can play an important role in rocket engine test facility design and development by assessing risks, providing analysis of dynamic pressure and thermal loads, identifying failure modes and predicting anomalous behavior of critical systems. Advanced numerical tools assume greater significance in supporting testing and design of high altitude testing facilities and plume induced testing environments of high thrust engines because of the greater inter-dependence and synergy in the functioning of the different sub-systems. This is especially true for facilities such as the proposed A-3 facility at NASA SSC because of a challenging operating envelope linked to variable throttle conditions at relatively low chamber pressures. Facility designs in this case will require a complex network of diffuser ducts, steam ejector trains, fast operating valves, cooling water systems and flow diverters that need to be characterized for steady state performance. In this paper, we will demonstrate with the use of CFD analyses s advanced capability to evaluate supersonic diffuser and steam ejector performance in a sub-scale A-3 facility at NASA Stennis Space Center (SSC) where extensive testing was performed. Furthermore, the focus in this paper relates to modeling of critical sub-systems and components used in facilities such as the A-3 facility. The work here will address deficiencies in empirical models and current CFD analyses that are used for design of supersonic diffusers/turning vanes/ejectors as well as analyses for confined plumes and venting processes. The primary areas that will be addressed are: (1) supersonic diffuser performance including analyses of thermal loads (2) accurate shock capturing in the diffuser duct; (3) effect of turning duct on the performance of the facility (4) prediction of mass flow rates and performance classification for steam ejectors (5) comparisons with test data from sub-scale diffuser testing and assessment of confidence levels in CFD based flowpath modeling of the facility. The analyses tools used here expand on the multi-element unstructured CFD which has been tailored and validated for impingement dynamics of dry plumes, complex valve/feed systems, and high pressure propellant delivery systems used in engine and component test stands at NASA SSC. The analyses performed in the evaluation of the sub-scale diffuser facility explored several important factors that influence modeling and understanding of facility operation such as (a) importance of modeling the facility with Real Gas approximation, (b) approximating the cluster of steam ejector nozzles as a single annular nozzle, (c) existence of mixed subsonic/supersonic flow downstream of the turning duct, and (d) inadequacy of two-equation turbulence models in predicting the correct pressurization in the turning duct and expansion of the second stage steam ejectors. The procedure used for modeling the facility was as follows: (i) The engine, test cell and first stage ejectors were simulated with an axisymmetric approximation (ii) the turning duct, second stage ejectors and the piping downstream of the second stage ejectors were analyzed with a three-dimensional simulation utilizing a half-plane symmetry approximation. The solution i.e. primitive variables such as pressure, velocity components, temperature and turbulence quantities were passed from the first computational domain and specified as a supersonic boundary condition for the second simulation. (iii) The third domain comprised of the exit diffuser and the region in the vicinity of the facility (primary included to get the correct shock structure at the exit of the facility and entrainment characteristics). The first set of simulations comprising the engine, test cell and first stage ejectors was carried out both as a turbulent real gas calculation as well as a turbulent perfect gas calculation. A comparison for the two cases (Real Turbulent and Perfect gas turbulent) of the Ma Number distribution and temperature distributions are shown in Figures 1 and 2 respectively.

Allgood, Daniel C.↗

Physics of Reconnection and MMS Mission

Reconnection is the most important process driving the Earth's magnetosphere. Key to the success of the MMS science plan is the coupling of theory and observation. Determining the kinetic processes occurring in the diffusion region and physical parameters that control the rate of magnetic reconnection are among primary objectives of the MMS mission. Analysis of the role played by particle inertial effects in the diffusion region where the plasma is unmagnetized will be presented. The reconnection electric field in he diffusion region is supported primarily by particle non-gyrotropic effects. At the quasi-steady stage the reconnection electric field serves to accelerate and heat the incoming plasma population to maintain the current flow in the diffusion region the pressure balance. The primary mechanism controlling the dissipation in the vicinity of the reconnection site is incorporated into the fluid description in terms of non-gyrotropic corrections to the. induction and energy equations. The results of kinetic and fluid simulations illustrating the physics of magnetic reconnection will be presented. We will dem~:tistrate that kinetic nongyrotropic effects can significantly alter the global magnetosphere evolution and location of reconnection sites.

Kuznetsova, M. M.↗

A uniqueness proof for a transonic flow problem

The uniqueness of the first-order lifting-line correction to the two-dimensional transonic small disturbance potential for the flow past a lifting, three-dimensional, large-aspect-ratio wing is proved. The correction is the solution of a linear equation of mixed type in the plane slit along the positive x-axis. The boundary data consist of Neumann data, continuity restrictions, the Kutta condition, and the form of the asymptotic behavior at infinity. The zeroth-order flow is assumed to be shock-free, and hence the correction is shock-free.

Cook, L. P.↗

Nasa Glenn Icing Research Tunnel: 2018 Change in Drop-Sizing Equations Due to Change in Cloud Droplet Probe Sample Area

Although there has been no physical change to the cloud drop diameters in the NASA Glenn Icing Research Tunnel (IRT), the IRT cloud calibration team now has an improved understanding of the facility’s drop-sizing instrumentation, which has resulted in a recent change to the drop-sizing equations. Only the calculated values given in the previous calibration report have changed. In 2017, IRT staff found reason to believe that since at least 2014, the sample area for its Cloud Droplet Probe (CDP) (Droplet Measurement Technologies, Inc.) has been closer to 0.289 mm2, rather than the user manual’s suggested value of 0.24 mm2. In September 2017, the probe’s sample area was measured both before and after the probe was realigned, and the end sample area was measured to be 0.248 mm2. Following the probe’s realignment, drop size measurements were made in the IRT using the CDP as well as optical array probes OAP–230X and OAP–230Y (Particle Measurement Systems, Inc.). These measurements suggested that 0.289 mm2 was the more accurate value for historical measurements. When the CDP sample area used for calculations was changed from 0.24 to 0.289 mm2, distributions previously reported to have a median volumetric diameter (MVD) between 30 and 100 μm were instead calculated to have MVD values 10 to 18 percent higher. The analyses that led to these conclusions are reported in this paper, as well as the new drop-sizing equations that have been developed for the corrected measurement values. This report contains updates to drop-sizing data for the IRT’s “normal” operating conditions (MVD < 50 μm) and discusses the effects on the IRT’s “large-drop” conditions (Mod1 nozzles, Pair < 10 psig), but it does not include updates to the drop-sizing equations for those large-drop conditions.

Particle sizing↗

Atmospheric Pre-Corrected Differential Absorption Techniques to Retrieve Columnar Water Vapor: Theory and Simulations

Two different approaches exist to retrieve columnar water vapor from imaging spectrometer data: (1) Differential absorption techniques based on: (a) Narrow-Wide (N/W) ratio between overlapping spectrally wide and narrow channels; (b) Continuum Interpolated Band Ratio (CIBR) between a measurement channel and the weighted sum of two reference channels. (2) Non-linear fitting techniques which are based on spectral radiative transfer calculations. The advantage of the first approach is computational speed and of the second, improved retrieval accuracy. Our goal was to improve the accuracy of the first technique using physics based on radiative transfer. Using a modified version of the Duntley equation, we derived an "Atmospheric Pre-corrected Differential Absorption" (APDA) technique and described an iterative scheme to retrieve water vapor on a pixel-by-pixel basis. Next we compared both, the CIBR and the APDA using the Duntley equation for MODTRAN3 computed irradiances, transmissions and path radiance (using the DISORT option). This simulation showed that the CIBR is very sensitive to reflectance effects and that the APDA performs much better. An extensive data set was created with the radiative transfer code 6S over 379 different ground reflectance spectra. The calculated relative water vapor error was reduced significantly for the APDA. The APDA technique had about 8% (vs. over 35% for the CIBR) of the 379 spectra with a relative water vapor error of greater than +5%. The APDA has been applied to 1991 and 1995 AVIRIS scenes which visually demonstrate the improvement over the CIBR technique.

Borel, Christoph C.↗

Nonlinear evolution of quadratic gravity in 3 + 1 dimensions

We present a numerically stable system of ( 3 + 1 ) evolution equations for the nonlinear gravitational dynamics of quadratic-curvature corrections to General Relativity (quadratic gravity). We also report on the numerical implementation of these evolution equations. We recover a well-known linear instability and gather evidence that—aside from said instability—quadratic gravity exhibits a physically stable Ricci-flat subsector. In particular, we demonstrate that Teukolsky-wave perturbations of a Schwarzschild black hole as well as a full binary inspiral (evolved up to merger) remain Ricci flat throughout evolution. Furthermore, this suggests that, at least in vacuum, classical quadratic gravity can mimic General Relativity, even in the fully nonlinear strong-gravity regime.

79 ASTRONOMY AND ASTROPHYSICS↗

Magnetic frame-dragging correction to the electromagnetic solution of a compact neutron star

ABSTRACT Neutron stars are usually modelled as spherical, rotating perfect conductors with a predominant intrinsic dipolar magnetic field anchored to their stellar crust. Due to their compactness, General Relativity corrections must be accounted for in Maxwell’s equations, leading to modified interior and exterior electromagnetic solutions. We present analytical solutions for slowly rotating magnetized neutron stars, taking into account the magnetic frame-dragging correction. For typical compactness values, i.e. Rs ∼ 0.5 [R*], we show that the new terms lead to a per cent order correction in the magnetic field orientation and strength compared to the case, with no magnetic frame-dragging correction. Also, we obtain a self-consistent redistribution of the surface azimuthal current. We verify the validity of the derived solution through two-dimensional particle-in-cell simulations of an isolated neutron star. Defining the azimuthal electric and magnetic field amplitudes during the transient phase as observables, we prove that the magnetic frame-dragging correction reduces the transient wave amplitude, as expected from the analytical solution. We show that simulations are more accurate and stable, when we include all first-order terms. The increased accuracy at lower spatiotemporal resolutions translates into a reduction in simulation runtimes.

Torres, R. (ORCID:0000000291820228)↗

Auto Emission Testing

The photos show automobile engines being tested for nitrous oxide emissions, as required by the Environmental Protection Agency (EPA), at the Research and Engineering Division of Ford Motor Company, Dearborn. Michigan. NASA technical information helped the company develop a means of calculating emissions test results. Nitrous oxide emission readings vary with relative humidity in the test facility. EPA uses a standard humidity measurement, but the agency allows manufacturers to test under different humidity conditions, then apply a correction factor to adjust the results to the EPA standard. NASA's Dryden Flight Research Center developed analytic equations which provide a simple, computer-programmable method of correcting for humidity variations. A Ford engineer read a NASA Tech Brief describing the Dryden development and requested more detailed information in the form of a technical support package, which NASA routinely supplies to industry on request. Ford's Emissions Test Laboratory now uses the Dryden equations for humidity-adjusted emissions data reported to EPA.

Source record↗

Meteorological Sensor Calibration Facility

The meteorological sensor calibration facility is designed to test and assess radiosonde measurement quality through actual flights in the atmosphere. United States radiosonde temperature measurements are deficient in that they require correction for errors introduced by long- and short-wave radiation. The effect of not applying corrections results in a large bias between day time and night time measurements. This day/night bias has serious implications for users of radiosonde data, of which NASA is one. The derivation of corrections for the U.S. radiosonde is quite important. Determination of corrections depends on solving the heat transfer equation of the thermistor using laboratory measurements of the emissivity and absorptivity of the thermistor coating. The U.S. radiosonde observations from the World Meteorological Organization International Radiosonde Intercomparison were used as the data base to test whether the day/night height bias can be removed. Twenty-five noon time and 26 night time observations were used. Corrected temperatures were used to calculate new geopotentials. Day/night bias in the geopotentials decreased significantly when corrections were introduced. Some testing of thermal lag attendant with the standard carbon hygristor took place. Two radiosondes with small bead thermistors imbedded in the hygristor were flown. Detailed analysis was not accomplished; however, cursory examination of the data showed that the hygristor is at a higher temperature than the external thermistor indicates.

Schmidlin, F. J.↗

Associative Flow Rule Used to Include Hydrostatic Stress Effects in Analysis of Strain-Rate-Dependent Deformation of Polymer Matrix Composites

designing reliable composite engine cases that are lighter than the metal cases in current use. The types of polymer matrix composites that are likely to be used in such an application have a deformation response that is nonlinear and that varies with strain rate. The nonlinearity and the strain-rate dependence of the composite response are due primarily to the matrix constituent. Therefore, in developing material models to be used in the design of impact-resistant composite engine cases, the deformation of the polymer matrix must be correctly analyzed. However, unlike in metals, the nonlinear response of polymers depends on the hydrostatic stresses, which must be accounted for within an analytical model. By applying micromechanics techniques along with given fiber properties, one can also determine the effects of the hydrostatic stresses in the polymer on the overall composite deformation response. First efforts to account for the hydrostatic stress effects in the composite deformation applied purely empirical methods that relied on composite-level data. In later efforts, to allow polymer properties to be characterized solely on the basis of polymer data, researchers at the NASA Glenn Research Center developed equations to model the polymers that were based on a non-associative flow rule, and efforts to use these equations to simulate the deformation of representative polymer materials were reasonably successful. However, these equations were found to have difficulty in correctly analyzing the multiaxial stress states found in the polymer matrix constituent of a composite material. To correct these difficulties, and to allow for the accurate simulation of the nonlinear strain-rate-dependent deformation analysis of polymer matrix composites, in the efforts reported here Glenn researchers reformulated the polymer constitutive equations from basic principles using the concept of an associative flow rule. These revised equations were characterized and validated in an experimental program carried out through a university grant with the Ohio State University, wherein tensile and shear deformation data were obtained for a representative polymer for strain rates ranging from quasi-static to high rates of several hundred per second. Tensile deformation data also were obtained over a variety of strain rates and fiber orientation angles for a representative polymer matrix composite composed using the polymer.

Goldberg, Robert K.↗

Three-step LES-C models for flows at high Reynolds numbers

Here, we investigate the need for the second correction step in the recently proposed LES-C models for fluid flows at high Reynolds numbers. These models use a predictor-corrector idea to enhance the efficiency of the existing Large Eddy Simulation models. Different three-step(one defect step, two corrections) LES-C models, based on the Leray-α, ADM and NS-ω LES models, are tested in three different situations. The new Leray-α-C2 model (C2 stands for two correction steps) is applied to the Navier–Stokes equations; the ADC2 is applied to the MagnetoHydroDynamic flow; and the NS-ω-C2 is used in the fluid-fluid interaction problem. We evaluate the effectiveness of the second correction step in all these settings, using qualitative and quantitative numerical tests.

97 MATHEMATICS AND COMPUTING↗

Simulation of Oxygen Disintegration and Mixing With Hydrogen or Helium at Supercritical Pressure

The simulation of high-pressure turbulent flows, where the pressure, p, is larger than the critical value, p(sub c), for the species under consideration, is relevant to a wide array of propulsion systems, e.g. gas turbine, diesel, and liquid rocket engines. Most turbulence models, however, have been developed for atmospheric-p turbulent flows. The difference between atmospheric-p and supercritical-p turbulence is that, in the former situation, the coupling between dynamics and thermodynamics is moderate to negligible, but for the latter it is very significant, and can dominate the flow characteristics. The reason for this stems from the mathematical form of the equation of state (EOS), which is the perfect-gas EOS in the former case, and the real-gas EOS in the latter case. For flows at supercritical pressure, p, the large eddy simulation (LES) equations consist of the differential conservation equations coupled with a real-gas EOS. The equations use transport properties that depend on the thermodynamic variables. Compared to previous LES models, the differential equations contain not only the subgrid scale (SGS) fluxes, but also new SGS terms, each denoted as a correction. These additional terms, typically assumed null for atmospheric pressure flows, stem from filtering the differential governing equations, and represent differences between a filtered term and the same term computed as a function of the filtered flow field. In particular, the energy equation contains a heat-flux correction (q-correction) that is the difference between the filtered divergence of the heat flux and the divergence of the heat flux computed as a function of the filtered flow field. In a previous study, there was only partial success in modeling the q-correction term, but in this innovation, success has been achieved by using a different modeling approach. This analysis, based on a temporal mixing layer Direct Numerical Simulation database, shows that the focus in modeling the q-correction should be on reconstructing the primitive variable gradients rather than their coefficients, and proposes the approximate deconvolution model (ADM) as an effective means of flow field reconstruction for LES heat flux calculation. Further, results for a study conducted for temporal mixing layers initially containing oxygen in the lower stream, and hydrogen or helium in the upper stream, show that, for any LES, including SGS-flux models (constant-coefficient Gradient or Scale-Similarity models, dynamic-coefficient Smagorinsky/Yoshizawa or mixed Smagorinsky/Yoshizawa/Gradient models), the inclusion of the q-correction in the LES leads to the theoretical maximum reduction of the SGS heat-flux difference. The remaining error in modeling this new subgrid term is thus irreducible.

Bellan, Josette↗

Computer simulation of transonic flow past airfoils with boundary layer correction

A computer program has been developed to solve the compressible flow equation for the velocity potential. The exterior of the airfoil is mapped onto the unit circle and the flow is computed on a grid in the circle plane. A relaxation method using backward differencing in the flow direction at supersonic points permits solutions for large supersonic areas. The pressure distribution resulting from the flow becomes the input to the von Karman momentum equation which when integrated gives the displacement thickness. This displacement thickness is smoothed and added to the airfoil to account for the turbulent boundary layer. The boundary layer correction is computed iteratively with the flow. Results from this program and test data agree well.

Bauer, F.↗

Documenting the NASA Armstrong Flight Research Center Oblate Earth Simulation Equations of Motion and Integration Algorithm

A desire for more complete documentation of the National Aeronautics and Space Administration (NASA) Armstrong Flight Research Center (AFRC), Edwards, California legacy code used in the core simulation has led to this e ort to fully document the oblate Earth six-degree-of-freedom equations of motion and integration algorithm. The authors of this report have taken much of the earlier work of the simulation engineering group and used it as a jumping-o point for this report. The largest addition this report makes is that each element of the equations of motion is traced back to first principles and at no point is the reader forced to take an equation on faith alone. There are no discoveries of previously unknown principles contained in this report; this report is a collection and presentation of textbook principles. The value of this report is that those textbook principles are herein documented in standard nomenclature that matches the form of the computer code DERIVC. Previous handwritten notes are much of the backbone of this work, however, in almost every area, derivations are explicitly shown to assure the reader that the equations which make up the oblate Earth version of the computer routine, DERIVC, are correct.

integrators↗