Search NASA⌕ Search

SEARCH · Search NASA

Results for “Count”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

High-Resolution Mosaic Imaging with Multifocal, Multiphoton Photon-Counting Microscopy

High-resolution mosaic imaging is performed for the first time to our knowledge with a multifocal, multiphoton, photon-counting imaging system. We present a novel design consisting of a home-built femtosecond Yb-doped KGdWO{sub 4} laser with an optical multiplexer, which is coupled with a commercial Olympus IX-71 microscope frame. Photon counting is performed using single-element detectors and an inexpensive electronic demultiplexer and counters.

47 OTHER INSTRUMENTATION↗

A Block-Based Triangle Counting Algorithm on Heterogeneous Environments

Triangle counting is a fundamental building block in graph algorithms. In this paper, we propose a block-based triangle counting algorithm to reduce data movement during both sequential and parallel execution. Our block-based formulation makes the algorithm naturally suitable for heterogeneous architectures. The problem of partitioning the adjacency matrix of a graph is well-studied. Our task decomposition goes one step further: it partitions the set of triangles in the graph. By streaming these small tasks to compute resources, we can solve problems that do not fit on a device. We demonstrate the effectiveness of our approach by providing an implementation on a compute node with multiple sockets, cores and GPUs. The current state-of-the-art in triangle enumeration processes the Friendster graph in 2.1 seconds, not including data copy time between CPU and GPU. Using that metric, our approach is 20 percent faster. When copy times are included, our algorithm takes 3.2 seconds. This is 5.6 times faster than the fastest published CPU-only time.

97 MATHEMATICS AND COMPUTING↗

Photon Counting Techniques for the Bandlimited Optical Channel

Two methods of estimating received photon counts given a realistic noisy and bandlimited optical channel are presented. The function of estimating photon counts is critical in any optical communications receiver. The purpose of this work is to compare two methods, neither of which is generically optimal, with realistic channels-for the purpose of assessing which is more appropriate for application in a hardware receiver given the current state-of-the art.

photons↗

Counting RG flows

Here, interpreting renormalization group flows as solitons interpolating between different fixed points, we ask various questions that are normally asked in soliton physics but not in renormalization theory. Can one count RG flows? Are there different "topological sectors" for RG flows? What is the moduli space of an RG flow, and how does it compare to familiar moduli spaces of (supersymmetric) dowain walls? Analyzing these questions in a wide variety of contexts -- from counting RG walls to AdS/CFT correspondence -- will not only provide favorable answers, but will also lead us to a unified general framework that is powerful enough to account for peculiar RG flows and predict new physical phenomena. Namely, using Bott's version of Morse theory we relate the topology of conformal manifolds to certain properties of RG flows that can be used as precise diagnostics and "topological obstructions" for the strong form of the C-theorem in any dimension. Moreover, this framework suggests a precise mechanism for how the violation of the strong C-theorem happens and predicts "phase transitions" along the RG flow when the topological obstruction is non-trivial. Along the way, we also find new conformal manifolds in well-known 4d CFT's and point out connections with the superconformal index and classifying spaces of global symmetry groups.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Casimir meets Poisson: improved quark/gluon discrimination with counting observables

Charged track multiplicity is among the most powerful observables for discriminating quark- from gluon-initiated jets. Despite its utility, it is not infrared and collinear (IRC) safe, so perturbative calculations are limited to studying the energy evolution of multiplicity moments. While IRC-safe observables, like jet mass, are perturbatively calculable, their distributions often exhibit Casimir scaling, such that their quark/gluon discrimination power is limited by the ratio of quark to gluon color factors. In this paper, we introduce new IRC-safe counting observables whose discrimination performance exceeds that of jet mass and approaches that of track multiplicity. The key observation is that track multiplicity is approximately Poisson distributed, with more suppressed tails than the Sudakov peak structure from jet mass. By using an iterated version of the soft drop jet grooming algorithm, we can define a “soft drop multiplicity” which is Poisson distributed at leading-logarithmic accuracy. In addition, we calculate the next-to-leading-logarithmic corrections to this Poisson structure. If we allow the soft drop groomer to proceed to the end of the jet branching history, we can define a collinear-unsafe (but still infrared-safe) counting observable. Exploiting the universality of the collinear limit, we define generalized fragmentation functions to study the perturbative energy evolution of collinear-unsafe multiplicity.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Performance of Tantalum STJ X-ray Detectors at Elevated Count Rates

Here, we have developed an X-ray detector system based on Ta superconducting tunnel junctions (STJs) with an energy resolution below 10 eV under 1 keV. A principal advantage of STJs over other low-temperature detectors is their high count rate capability. In this work, we have optimized the operating conditions and digital pulse processing parameters for input count rates up to 25 kcps/pixel. Resolution below 10 eV is maintained up to 2.5 kcps/pixel, and at input rates of 25 kcps per pixel the resolution is 26 eV FWHM at 525 eV.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Calculation of the cross and auto power spectral densities for low neutron counting from pulse mode detectors

Here, this report introduces a methodology to calculate the prompt neutron decay constant of a subcritical assembly from the cross and auto power spectral densities of detectors operating in pulse mode when the neutron counting is low. The pulse operation mode allows the easy discrimination of the gamma contribution to the detector signal by the pulse height or shape techniques. The methodology is based on a MATLAB script that allows to change arbitrary parameters at any time after the experiment is performed. This technique requires list mode data and is much more flexible than programming the digital acquisition system because in the latter case the arbitrary parameters are set prior to the experiment and cannot be changed any longer after the experiment is performed. The MATLAB script processes all the detectors timestamps from several thousand pulses of the particle accelerator and redistributes them into a time interval that spreads over only 10 particle accelerator pulses. This pulses collapsing procedure has been performed because of the low neutron counting.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hydrogen cluster/network in tobermorite as studied by multiple-quantum spin counting {sup 1}H NMR

Proton multiple-quantum (MQ) spin-counting experiment has been employed to study arrangement of hydrogen atoms in 9 Å/11 Å natural/synthetic tobermorites. Even though all tobermorite samples give similar characterless, broad static-powder {sup 1}H NMR spectra, their MQ spin-counting spectra are markedly different; higher quanta in 11 Å tobermorite do not grow with the MQ excitation time, while those in 9 Å one do. A statistical analysis of the MQ results recently proposed [26] is applied to show that hydrogens align in 9 Å tobermorite one dimensionally, while in 11 Å tobermorite they exist as a cluster of 5–8 hydrogen atoms.

36 MATERIALS SCIENCE↗

Demonstration of low-level biogenic fuel content using quench curve and direct liquid scintillation counting (LSC) methods

In this work, an investigation into the direct method for liquid scintillation counting (LSC) quantification of biogenic fuel content in fuel blendstock is presented. This method development intentionally used a colored matrix (~99 wt%), fossil diesel fraction, and low-level biogenic fractions (~1 wt%) to determine the applicability of the LSC technique in colored blend mixtures. LSC procedures for quench correction, including the use of an instrument internal standard (Quantulus SQP values), color quench curves, and an internal 14 C standard spike on samples containing low-level amounts of biogenic gasoline, jet, and diesel mixed with fossil fuel, were compared. Samples were analyzed on both Perkin-Elmer Quantulus and Tri-Carb instruments, and the 14 C contents were compared with those determined by accelerator mass spectrometry (AMS). Results from the Tri-Carb instrument showed that percent differences of <10 % compared to AMS-reported values are achievable at 5-hour count times despite colored samples. A comparison between the impact of chemical and color quenching in the fuel samples showed that color quenching in highly colored samples reduces efficiency significantly more than chemical quenching, indicating that chemical quench curves are not appropriate for highly colored biofuel/fossil-fuel blended samples. Results indicate that both the direct method with internal spike quench correction and the use of a color-quench curve provide accurate results for 1 % biogenic fuel blends. Additionally, we have explored the use of Fourier transform infrared (FTIR) spectroscopy in measuring the biogenic content of the colored blended fuel samples. Preliminary results show the presence of biogenic carbon-derived fingerprints that are absent in fossil-derived sample. However, further work is needed to develop an FTIR-based quantitative method.

09 BIOMASS FUELS↗

Circulating Lymphocyte Counts Early During Radiation Therapy Are Associated With Recurrence in Pediatric Medulloblastoma

Decreased peripheral lymphocyte counts are associated with survival after radiation therapy (RT) in several solid tumors, although they appear late during or after the radiation course and often correlate with other clinical factors. Here we investigate if absolute lymphocyte counts (ALCs) are independently associated with recurrence in pediatric medulloblastoma early during RT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of pulse shape discrimination performance of stilbene and liquid scintillator under high count-rate active interrogation conditions

Here, we compare the pulse-shape-discrimination performance of a large Stilbene detector, manufactured at the Lawrence Livermore National Laboratory, to a similarly sized liquid scintillator, made by Eljen Technologies, Inc. (type EJ309), under various high-count-rate scenarios, such as can be expected during Active Interrogation of objects using an electric neutron generator for detecting the presence of Special Nuclear Materials and contraband. Pulse Shape Discrimination (PSD) is performed with an extension of previously described wavelet and event fitting algorithms, which are also used to reject pileup events and to correct the energy calibration for event signals clipped during digitization. We find that strong PSD and pileup rejection cuts are required to function in this high-count-rate environment. Whereas the Stilbene detector has intrinsically better pulse-shape discrimination performance, the pulses of events from the liquid scintillator are somewhat narrower, reducing pileup. We use an event fitting cut that provides simultaneous PSD identification and pileup rejection. When applying the same cut to data taken with both detectors, we find that Stilbene has higher event use efficiency by about a factor of two and retains a better gamma rejection ratio compared to EJ309.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Algorithms of pulse shape analysis for Gammasphere under high count rate conditions

The implementation of digital electronics for the multi-detector Gammasphere array has provided an opportunity to perform experiments which exceed the technical capabilities of its analog counterpart. The pulse shape analysis of HPGe detectors is presented for the purpose of determining the γ-ray energy under high-counting rates and short integration times with the aim of improving the data throughput. A revised trapezoidal algorithm is delineated which is able to determine the γ-ray energies during the offline analysis without being constrained by predetermined parameters. The performance of this algorithm is discussed, and compared with that of the analog system. The measured energy resolution meets expectations for operations with high-counting rates and short integration times.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Absolute decay counting of 146 Sm with 4π cryogenic microcalorimetry

We present a methodology for absolute activity counting of long-lived isotopes based on cryogenic Decay Energy Spectroscopy. A 146 Sm source was produced at the TRIUMF Laboratory and then processed and purified at Lawrence Livermore National Laboratory, yielding a pure sample. The source was embedded within a 4π thermal absorber coupled to a magnetic microcalorimeter achieving nearly 100% counting efficiency. Experimental uncertainties were studied and modeled, including thermal coupling of the source to the absorber, pulse pile-up, trigger, and event selection efficiencies. Here, the absolute activity of the pure 146 Sm source was measured to better than 1% uncertainty.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Clean and Convenient Tessellations for Number Counting Jastrow Factors

We introduce a basis of counting functions that, by cleanly tessellating three-dimensional space, allows real space number counting Jastrow factors to be straightforwardly applied to general molecular situations. Here, by exerting direct control over electron populations in local regions of space and encoding pairwise correlations between these populations, these Jastrow factors allow even very simple reference wave functions to adopt nodal surfaces well suited to many strongly correlated settings. Being trivially compatible with traditional Jastrow factors and diffusion Monte Carlo and having the same cubic per-sample cost scaling as a single determinant trial function, these Jastrow factors thus offer a powerful new route to the simultaneous capture of weak and strong electron correlation effects in a wide variety of molecular and materials settings. In multiple strongly correlated molecular examples, we show that even when paired with the simplest possible single determinant reference, these Jastrow factors allow quantum Monte Carlo to out-perform coupled cluster theory and approach the accuracy of traditional multireference methods.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Photon Counting Data Analysis: Application of the Maximum Likelihood and Related Methods for the Determination of Lifetimes in Mixtures of Rose Bengal and Rhodamine B

It is often convenient to know the minimum amount of data needed in order to obtain a result of desired accuracy and precision. It is a necessity in the case of subdiffraction-limited microscopies, such as stimulated emission depletion (STED) microscopy, owing to the limited sample volumes and the extreme sensitivity of the samples to photobleaching and photodamage. We present a detailed comparison of probability-based techniques (the maximum likelihood method and methods based on the binomial and the Poisson distributions) with residual minimization-based techniques for retrieving the fluorescence decay parameters for various two-fluorophore mixtures, as a function of the total number of photon counts, in time-correlated, single-photon counting experiments. The probability-based techniques proved to be the most robust (insensitive to initial values) in retrieving the target parameters and, in fact, performed equivalently to 2-3 significant figures. This is to be expected, as we demonstrate that the three methods are fundamentally related. Furthermore, methods based on the Poisson and binomial distributions have the desirable feature of providing a bin-by-bin analysis of a single fluorescence decay trace, which thus permits statistics to be acquired using only the one trace for not only the mean and median values of the fluorescence decay parameters but also for the associated standard deviations. Lastly, these probability-based methods lend themselves well to the analysis of the sparse data sets that are encountered in subdiffraction-limited microscopies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Planck 2015 results: XXIV. Cosmology from Sunyaev-Zeldovich cluster counts

In this work, we present cluster counts and corresponding cosmological constraints from the Planck full mission data set. Our catalogue consists of 439 clusters detected via their Sunyaev-Zeldovich (SZ) signal down to a signal-to-noise ratio of 6, and is more than a factor of 2 larger than the 2013 Planck cluster cosmology sample. The counts are consistent with those from 2013 and yield compatible constraints under the same modelling assumptions. Taking advantage of the larger catalogue, we extend our analysis to the two-dimensional distribution in redshift and signal-to-noise. We use mass estimates from two recent studies of gravitational lensing of background galaxies by Planck clusters to provide priors on the hydrostatic bias parameter, (1-b). In addition, we use lensing of cosmic microwave background (CMB) temperature fluctuations by Planck clusters as an independent constraint on this parameter. These various calibrations imply constraints on the present-day amplitude of matter fluctuations in varying degrees of tension with those from the Planck analysis of primary fluctuations in the CMB; for the lowest estimated values of (1-b) the tension is mild, only a little over one standard deviation, while it remains substantial (3.7σ) for the largest estimated value. We also examine constraints on extensions to the base flat ΛCDM model by combining the cluster and CMB constraints. The combination appears to favour non-minimal neutrino masses, but this possibility does little to relieve the overall tension because it simultaneously lowers the implied value of the Hubble parameter, thereby exacerbating the discrepancy with most current astrophysical estimates. In conclusion, improving the precision of cluster mass calibrations from the current 10%-level to 1% would significantly strengthen these combined analyses and provide a stringent test of the base ΛCDM model.

79 ASTRONOMY AND ASTROPHYSICS↗

The SRG/eROSITA All-Sky Survey: Constraints on ultralight axion dark matter through galaxy cluster number counts

Ultralight axions are hypothetical scalar particles that influence the evolution of large-scale structures of the Universe. Depending on their mass, they can potentially be part of the dark matter component of the Universe as candidates commonly referred to as fuzzy dark matter. While strong constraints have been established for pure fuzzy dark matter models, the more general scenario where ultralight axions constitute only a fraction of the dark matter has been limited to only a few observational probes. In this work, we use the galaxy cluster number counts obtained from the first All-Sky Survey (eRASS1) of the SRG/eROSITA mission together with gravitational weak lensing data from the Dark Energy Survey, the Kilo-Degree Survey, and the Hyper Suprime-Cam to constrain the fraction of ultralight axions in the mass range 10 −32 eV to 10 −24 eV. We put upper bounds on the ultralight axion relic density Ω a in independent logarithmic axion mass bins by performing a full cosmological parameter inference. We find an exclusion region in the intermediate ultralight axion mass regime with the tightest bounds reported so far in the mass bins around m a = 10 −27 eV with Ω a < 0.0035 and m a = 10 −26 eV with Ω a < 0.0079; both are at a 95% confidence level. When combined with cosmic microwave background probes, these bounds are tightened to Ω a < 0.0030 in the m a = 10 −27 eV mass bin and Ω a < 0.0058 in the m a = 10 −26 eV mass bin, with both at a 95% confidence level. This is the first time that constraints on ultralight axions have been obtained using the growth of structure measured by galaxy cluster number counts. These results pave the way for large surveys, which can be utilized to obtain tight constraints on the mass and relic density of ultralight axions with better theoretical modeling of the abundance of halos.

cosmological parameters↗

Improving Accuracy and Precision in Gross Alpha and Beta Counting with Proportional Detectors

Following ambiguous results of an intercomparison exercise in 2004, we have reevaluated the sample preparation, measurement procedures and data treatment for gross alpha and beta counting. It was found that the Portuguese standards NP 4332:1996 and NP 4330:1996 do not provide enough background for correct treatment of data. This paper describes the improvements made in gross alpha and beta activities measurement with proportional detectors in simultaneous mode. These improvements include a crosstalk correction both on counting and in the minimum detectable activity; the use of adequate statistical tools for data analysis; the use of QC charts to control the stability of the detectors and the background and, attention to the traceability of results. The calibration curves were computed with an appropriate number of replicates and with a throughout evaluation of the uncertainty budget. Based on this model, we established new criteria to report results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗