Search NASA⌕ Search

SEARCH · Search NASA

Results for “Cryogen”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

High modulus filament wound vessels for cryogenic containers in spacecraft.

Compared to metallic vessels, filament-wound vessels for containment of cryogens and high pressure gases offer high potential weight savings for NASA spacecraft applications. Since carbon fiber/epoxy resin composites exhibit high strength-to-density ratios, high-cycle fatigue life, and excellent strain compatibility with internal metallic liners, filament-wound carbon fiber/epoxy resin composites were evaluated for application to cryogenic internal pressure vessels. Compared to room temperature values, the cryogenic strengths of the composites were reduced by about 15% at -423 F (with the exception of one composite) while moduli increased as much as 25%. Filament-wound carbon fiber/epoxy resin vessel specimens, made by three fabricators, defined and solved problems in the processing of these friable high-modulus fibers into structurally efficient vessel specimens.

Simon, R. A.↗

Long-term cryogenic space storage system

Discussion of the design, fabrication and testing of a 225-cu ft spherical cryogenic storage system for long-term subcritical applications under zero-g conditions in storing subcritical cryogens for space vehicle propulsion systems. The insulation system design, the analytical methods used, and the correlation between the performance test results and analytical predictions are described. The best available multilayer insulation materials and state-of-the-art thermal protection concepts were applied in the design, providing a boiloff rate of 0.152 lb/hr, or 0.032% per day, and an overall heat flux of 0.066 Btu/sq ft hr based on a 200 sq ft surface area. A six to eighteen month cryogenic storage is provided by this system for space applications.

Hopkins, R. A.↗

The cryogenic wind tunnel concept for high Reynolds number testing

Theoretical considerations indicate that cooling the wind-tunnel test gas to cryogenic temperatures will provide a large increase in Reynolds number with no increase in dynamic pressure while reducing the tunnel drive-power requirements. Studies were made to determine the expected variations of Reynolds number and other parameters over wide ranges of Mach number, pressure, and temperature, with due regard to avoiding liquefaction. Practical operational procedures were developed in a low-speed cryogenic tunnel. Aerodynamic experiments in the facility demonstrated the theoretically predicted variations in Reynolds number and drive power. The continuous-flow-fan-driven tunnel is shown to be particularly well suited to take full advantage of operating at cryogenic temperatures.

Kilgore, R. A.↗

Simulation of flight test conditions in the Langley pilot transonic cryogenic tunnel

The theory and advantages of the cryogenic tunnel concept are briefly reviewed. The unique ability to vary temperature independently of pressure and Mach number allows, in addition to large reductions in model loads and tunnel power, the independent determination of Reynolds number, Mach number, and aeroelastic effects on the aerodynamic characteristics of the model. Various combinations of Reynolds number and dynamic pressure are established to represent accurately flight variations of aeroelastic deformation with altitude changes. The consequences of the thermal and caloric imperfections of the test gas under cryogenic conditions were examined and found to be insignificant for operating pressures up to 5 atm. The characteristics of the Langley pilot transonic cryogenic tunnel are described and the results of initial tunnel operation are presented. Tests of a two-dimensional airfoil at a Mach number of 0.85 show identical pressure distributions for a chord Reynolds number of 8,600,000 obtained first at a stagnation pressure of 4.91 atm at a stagnation temperature of 322.0 K and then at a stagnation pressure of 1.19 atm at a stagnation temperature of 116.5 K.

Kilgore, R. A.↗

Analysis of validation tests of the Langley pilot transonic cryogenic tunnel

A pilot transonic cryogenic pressure tunnel has recently been developed and proof tested at the NASA Langley Research Center. In addition to providing an attractive method for obtaining high Reynolds number results at moderate aerodynamic loadings and tunnel power, this unique tunnel allows the independent determination of the effects of Reynolds number, Mach number, and dynamic pressure (aeroelasticity) on the aerodynamic characteristics of the model under test. The proof of concept experimental and theoretical studies are briefly reviewed. Experimental results obtained on both two- and three-dimensional models have substantiated that cryogenic test conditions can be set accurately and that cryogenic gaseous nitrogen is a valid test medium.

Ray, E. J.↗

Properties of cryogenically worked metals

A program was conducted to determine whether the mechanical properties of cryogenically worked 17-7PH stainless steel are suitable for service from ambient to cryogenic temperatures. It was determined that the stress corrosion resistance of the cryo-worked material is quite adequate for structural service. The tensile properties and fracture toughness at room temperature were comparable to titanium alloy 6Al-4V. However, at cryogenic temperatures, the properties were not sufficient to recommend consideration for structural service.

Schwartzberg, F. R.↗

Study of a Vuilleumier cycle cryogenic refrigerator for detector cooling on the limb scanning infrared radiometer

A program to detect and monitor the presence of trace constituents in the earth's atmosphere by using the Limb Scanning Infrared Radiometer (LSIR) is reported. The LSIR, which makes radiometric measurements of the earth's limb radiance profile from a space platform, contains a detector assembly that must be cooled to a temperature of 65 + or - 2 K. The feasibility of cooling the NASA-type detector package with Vuilleumier (VM) cryogenic refrigerator was investigated to develop a preliminary conceptual design of a VM refrigerator that is compatible with a flight-type LSIR instrument. The scope of the LSIR program consists of analytical and design work to establish the size, weight, power consumption, interface requirements, and other important characteristics of a cryogenic cooler that would meet the requirements of the LSIR. The cryogenic cooling requirements under the conditions that NASA specified were defined. Following this, a parametric performance analysis was performed to define the interrelationships between refrigeration characteristics and mission requirements. This effort led to the selection of an optimum refrigerator design for the LSIR mission.

Russo, S. C.↗

High-pressure cryogenic seals for pressure vessels

This investigation of the problems associated with reliably containing gaseous helium pressurized to 1530 bars (22 500 psi) between 4.2 K and 150 K led to the following conclusions: (1) common seal designs used in existing elevated-temperature pressure vessels are unsuitable for high-pressure cryogenic operation, (2) extrusion seal-ring materials such as Teflon, tin, and lead are not good seal materials for cryogenic high-pressure operation; and (3) several high-pressure cryogenic seal systems suitable for large-pressure vessel applications were developed; two seals required prepressurization, and one seal functioned repeatedly without any prepressurization. These designs used indium seal rings, brass or 304 stainless-steel anvil rings, and two O-rings of silicone rubber or Kel-F.

Buggele, A. E.↗

Gasdynamics of the cryogenic cooler of the Nimbus F spacecraft

This paper presents a theoretical study of the gasdynamic behavior of the system used to vent methane gas from an open-cycle cryogenic cooler carried on the Nimbus F satellite. The flow of this gas from the cryogen tank to the vent-line exit takes place at very low Reynolds number, and is strongly affected by variations in the tube cross-sectional area, substantial heat addition, and important frictional effects. All three of these factors play a role in determining the choking mass flow. Finite-difference calculations are used to establish the mass flow rates for a range of cryogen temperatures. Finite-difference calculations are also used to determine the flowfield in the plume that results when the vented gas exits from the spacecraft. The momentum-flux distributions within the plume are then used to estimate the torques applied to the spacecraft when the plume impinges on several surfaces near the exit point. These torque estimates compare favorably with flight data.

Rae, W. J.↗

Cryogenic temperature control by means of energy storage materials

An investigation was conducted to study the concept of thermal control by means of physical or chemical reaction heats for applications involving the storage of cryogens during long-term space voyages. The investigation included some preliminary experimental tests of energy storage material (ESM) effectiveness. The materials considered can store and liberate large amounts of thermal energy by means of mechanisms such as sensible heat, heat of fusion, and physical or chemical reaction heat. A differential thermal analysis was utilized in the laboratory tests. Attention is given to the evaluation of cryogenic ESM thermal control concepts, the experimental determination of phase change materials characteristics, and adsorption ESMs. It is found that an ESM shield surrounded by multiple layer insulation provides the best protection for a cryogen store.

Grodzka, P. G.↗

A promising new cryogenic seal candidate

The Space Shuttle carries more than 500,000 kg of liquid oxygen (LO2) and 100,000 kg of liquid hydrogen (LH2) propellant. Seals for this main propellant system therefore must provide extremely high reliability under prolonged service at cryogenic temperatures. The chief threat to consistently reliable operation is not the cryogenic service itself, but the 325 K temperature variation encountered during each individual mission. Moreover, this reliability must be sustained during the entire 100-mission/ten-year projected life of the Space Shuttle. It was feared that conventional liquid oxygen seal materials (filled Teflon and Kel-F) could cold flow or compression set to such an extent during the high-temperature phases of the 100 successive missions that failures could result. Thus, in addition to LO2 compatibility and cryogenic serviceability, this program was directed toward seals that were not thermoplastic and had good compression set resistance

Merz, P. L.↗

The 0.1m subsonic cryogenic tunnel at the University of Southampton

The design and performance of a low speed one atmosphere cryogenic wind tunnel is described. The tunnel is fan driven and operates over the temperature range 305K to 77K at Mach numbers up to 0.28. It is cooled by the injection and evaporation of liquid nitrogen in the circuit, and the usual test gas is nitrogen. The tunnel has a square test section 0.1m across and was built to allow, at low costs, the development of testing techniques and the development of instrumentation for use in cryogenic tunnels, and to exploit in general instrumentation work the unusuallly wide range of unit Reynolds number available in such tunnels. The tunnel was first used in the development of surface flow visualization techniques for use at cryogenic temperatures.

Goodyer, M. J.↗

Full-scale aircraft simulation with cryogenic tunnels and status of the National Transonic Facility

The effect of thermal and caloric imperfections in cryogenic nitrogen on boundary layers was determined to indicate that in order to simulate nonadiabatic laminar or turbulent boundary layers in a cryogenic nitrogen wind tunnel, the flight enthalpy ratio, rather than the temperature ratio, should be reproduced. The absence of significant real gas effects on both viscous and inviscid flows makes it unlikely that there will be large real gas effects on the cryogenic tunnel simulation of shock boundary layer interactions or other complex flow conditions encountered in flight. Condensation effects were studied to determine the minimum usable temperature and indicated that under most circumstances free stream Mach number rather than maximum local Mach number determines the onset of condensation effects.

Kilgore, R. A.↗

Development of the cryogenic tunnel concept and application to the US National Transonic Facility

A fan-driven, high Reynolds number, transonic cryogenic wind tunnel is described. The tunnel has a 2.5- by 2.5 m test section and is capable of operating from ambient to cryogenic temperatures at stagnation pressures up to 8.8 atm. An overview of the cryogenic concept and discussions of drive power requirements, support systems, and operating characteristics and performance of the wind tunnel are included.

Kilgore, R. A.↗

Spacelab 2 infrared telescope cryogenic system

The paper discusses the development of a cryogenic helium system to provide cooling to a scanning infrared telescope for the Spacelab 2 mission. The infrared optical/detector system and related electronics are being developed by the Smithsonian Astrophysical Observatory and the University of Arizona. A superfluid helium dewar and porous plug phase separator permit gas cooling of the infrared focal plane assembly to about 2.5 K, and of the two telescope sections to 8 K and 60 K. The design of the cryogenic system,including a commandable vacuum cover, and the prelaunch liquid helium servicing and maintenance approach were discussed. It is concluded that the system will satisfy the Infrared Telescope requirements, and the superfluid helium system shall be capable of satisfying cryogenic helium cooled requirements for the next several years.

Urban, E. W.↗

Automatic control of NASA Langley's 0.3-meter cryogenic test facility

Experience during the past 6 years of operation of the 0.3-meter transonic cryogenic tunnel at the NASA Langley Research Center has shown that there are problems associated with efficient operation and control of cryogenic tunnels using manual control schemes. This is due to the high degree of process crosscoupling between the independent control variables (temperature, pressure, and fan drive speed) and the desired test condition (Mach number and Reynolds number). One problem has been the inability to maintain long-term accurate control of the test parameters. Additionally, the time required to change from one test condition to another has proven to be excessively long and much less efficient than desirable in terms of liquid nitrogen and electrical power usage. For these reasons, studies have been undertaken to: (1) develop and validate a mathematical model of the 0.3-meter cryogenic tunnel process, (2) utilize this model in a hybrid computer simulation to design temperature and pressure feedback control laws, and (3) evaluate the adequacy of these control schemes by analysis of closed-loop experimental data. This paper will present the results of these studies.

Thibodeaux, J. J.↗

Real gas effects 2: Influence of condensation on minimum operating temperatures of cryogenic wind tunnels

Condensation effects are responsible for the minimum operating temperatures of cryogenic wind tunnels at total pressures up to about 9 atmospheres. The two primary modes of condensation homogeneous nucleation and heterogeneous nucleation and the conditions with which either may limit minimum operating temperatures are reveiwed. Previous hypersonic and supersonic condensation data are reviewed as are data taken in the nitrogen gas, Langley 0.3 Meter Transonic Cryogenic Tunnel. Analysis of data in the 0.3 m tunnel suggests that the onset of homogenous nucleation may be approximated by an analysis by sivier and that the onset of heterogeneous nucleation is only apparent just below free stream saturation. Extension of the results from the 0.3 m tunnel to other nitrogen gas cryogenic tunnels is discussed and is shown to depend on length scales, purity of the liquid nitrogen injected for cooling, number of particulates in the flow, and the extent to which the injected liquid nitrogen is evaporated.

Hall, R. M.↗

Modeling and control of transonic cryogenic wind tunnel: A summary report

A representative, control compatible, mathematical model of a cryogenic wind tunnel was synthesized which describes the unsteady behavior of the tunnel. The performance of this model was validated by appropriate transient and quasisteady state tests on the 0.3 m transonic cryogenic tunnel. An understanding was developed of the cryogenic tunnel behavior by an appropriate interactive real time simulation of the developed model.