Search NASA⌕ Search

SEARCH · Search NASA

Results for “DAMPER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Evaluating Attenuation of Vibration Response using Particle Impact Damping for a Range of Equipment Assemblies

Particle dampers provide a mechanism for diverting energy away from resonant structural vibrations. This experimental study provides data from a series of acoustically excited tests to determine the effectiveness of these dampers for equipment mounted to a curved orthogrid panel for a launch vehicle application. Vibration attenuation trends are examined for variations in particle damper fill level, component mass, and excitation energy. A significant response reduction at the component level was achieved, suggesting that comparatively small, strategically placed, particle damper devices might be advantageously used in launch vehicle design. These test results were compared to baseline acoustic response tests without particle damping devices, over a range of isolation and damping parameters. Instrumentation consisting of accelerometers, microphones, and still photography data will be collected to correlate with the analytical results.

Knight, Brent↗

Europa Clipper Preliminary Design Review Propellant Slosh Analysis

This presentation outlines the preliminary design review (PDR) propellant slosh analysis done for the Europa Clipper Mission. It provides sample results for both high acceleration pendulum-damper models and low acceleration pendulum-spring-damper models. The high acceleration pendulum-damper models were derived from STAR-CCM+ computational fluid dynamic (CFD) simulations and the low acceleration pendulum-spring-damper models were derived from Surface Evolver models.

slosh↗

An Investigation of Passive and Semi-Active TMD for a TLP Floating Offshore Wind Turbine in ULS Conditions

Floating offshore wind turbines are able to access deeper waters with stronger winds, but also have more complicated dynamic behavior than fixed-bottom offshore turbines, potentially resulting in larger loads. Structural control using tuned mass dampers (TMD) is a promising method for mitigating these loads. Previous research on structural control in wind turbines has typically considered passive devices and operational conditions. In this study, the effects of a passive tuned mass damper and a semi-active tuned mass damper, located at the tower top, are analyzed and simulated for the GE Haliade 150-6MW wind turbine located on the Glosten Pelastar tension-leg platform (TLP).

offshore wind turbines, dampers, tuned mass, semi-↗

Non-linear Wire Rope Isolator Model to Enhance Transportation Simulation of Fragile Equipment

Abstract Introduction Wire rope isolators are often used as means of vibration isolation for the transportation of fragile machine equipment. When deployed as suspension systems in a transportation scenario, a simple spring–damper model is often used to predict the dynamic loads that act on the structure being transported. However, this simple model has proved to be too simplistic to be used in the development of an accurate numerical model that can predict the vibration levels experienced by the inner components of fragile equipment during its transportation. This paper describes the experimental tests conducted on a wire rope isolator used for the transportation of the prototype SSR1 cryomodule. Materials and methods A hysteretic Bouc–Wen model has been used to analytically describe the force–deformation relationship of the wire rope isolators. The developed model of the isolator has been implemented in a larger model to simulate the actual transportation of the prototype SSR1 cryomodule, a section of the new PIP-II linear accelerator under construction at Fermilab. A series of multibody dynamic simulations with rigid and flexible components was used to numerically determine the acceleration of some critical components. Results and conclusions An actual experimental transportation was simulated using two numerical models: the developed Bouc–Wen model and a conventional spring–damper model. It is shown how the Bouc–Wen formulation of the isolator characteristics drastically improves the correspondence between experimental and simulated results if compared to a spring–damper model, especially in the range of 0–30 Hz which is the most critical for transportation problems.

42 ENGINEERING↗

Measurement of stability diagrams in the IOTA ring at Fermilab

Nonlinear focusing elements can enhance the stability of particle beams in high-energy colliders through Landau Damping, by means of the tune spread which is introduced. Here we discuss an experiment at Fermilab's Integrable Optics Test Accelerator (IOTA) which investigates the influence of nonlinear focusing elements, such as octupoles, on the beam’s transverse stability. In this experiment, we employ an anti-damper, an active transverse feedback system, as a controlled mechanism to induce coherent beam instability. By utilizing the anti-damper we can examine the impact of a nonlinear focusing element on the beam's transverse stability. The stability diagram, a tool used to determine the system's stability, is measured using a recently demonstrated method at the LHC. The experiment at IOTA adds insight towards this stability diagram measurement method by supplying a reduced machine impedance to investigate the machine impedance’s effect on the stability diagram, as well as by aiming to map out the full stability diagram by using a large phase range of the anti-damper. From this experiment in IOTA, we present the first results of stability diagram analysis with varying octupole currents.

43 PARTICLE ACCELERATORS↗

Grid Resilient, Self-Powered, Fuel Flexible, High Efficiency Heating System (Final Report)

The Grid Independent High Efficiency System (GIHES) delivers a heating system that operates free from the power grid and provides ultra-low emissions and high efficiency heating for residential and commercial buildings. The project demonstrated two weeks of continuous grid independent operation of a storage water heater equipped with a powered damper. The Thermoelectric Generator (TEG) integrated GIHES technology revolutionizes heating systems to provide grid resilient hot water production, while delivering significant value to the end user by eliminating impacts of power interruption and enhancing comfort, convenience and productivity. The system maximizes the thermal-to-electric conversion efficiency by optimizing location and orientation of the TEGs and durability while lowering system costs. The TEGs generate enough power to charge a battery and run the storage water heater unit with a powered damper uninterrupted by providing the required parasitic electrical power for start-up, shutdown and during idling. Several TEGs were analytically and experimentally evaluated based on the size, surface area and the power being generated before designing and fabricating a complete multi-TEG assembly for integration with the water heater. The GIHES technology can be extended to boilers, furnaces and tankless water heaters and integrated with heat pump to further increase the overall equipment efficiency. The technology has the potential to reduce the amount of dispatch power and peak power plant operation. An advanced burner was designed, developed and 3D printed for fuel flexible operation. The burner was designed to enable tighter integration with TEGs for potentially higher TEG output, should this be necessary. A bench-scale test rig to perform testing of a 200,000 Btu/h burner and capable of handling up to 10% H2 (by volume) was setup at GTI’s laboratory with appropriate safety and controls to ensure smooth and safe operation. Testing of the 3D burner showed < 5 ppm NOx emissions can be achieved for the entire firing range and with different levels of hydrogen blends with natural gas. The burner will enable a more integrated TEG-burner module design for improved system performance, should this be required in the future. Techno-economic analysis (TEA) of the TEG integrated with the water heaters was performed. The testing data and the power output were used to develop the TEA. The analysis for the storage unit with damper showed that the TEG integrated system costs $95. This is much lower than a one-time charge needed to wire and install dedicated power. Discussions with TEG manufacturers and OEM’s will provide more detailed information and methods to further lower these costs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance Demonstration of an Occupancy Sensor-enabled Integrated Solution for Commercial Buildings

Traditionally, a single-loop fixed-gain controller is applied to supply fan (SF) and cooling coil (CC) valve controls while a fixed-damper position control is applied to outdoor air (OA) damper control at air handling units (AHUs) in commercial buildings. With the increasing application of occupancy sensors, the information generated by occupancy sensors is applied to not only reduce the electricity loads from lighting and controllable plug loads, but also reset OA intake and minimum supply airflow setpoints. Meanwhile, these intermittent operation actions greatly elevate the dynamics of AHU systems, which may introduce unstable SF and CC valve operations and inaccurate OA flow control at AHUs and consequently degrade maximum energy efficiency gains. With virtual fan and valve flow meter technologies, two advanced controls, including cascade control and gain scheduling control, can be implemented on both the SF and CC valve, and an advanced control using a virtual OA flow meter can be implemented on OA damper integrated with occupancy sensors. The goal of this project is to demonstrate the savings, cost, and performance of an integrated solution that integrates the three advanced HVAC controls with occupancy sensors to allow accurate and stable AHU operations in real buildings. The project objectives are to: 1) develop and validate an advance SF control algorithm; 2) develop and validate an advanced CC valve control algorithm; 3) validate an algorithm to implement a virtual OA flow meter; and 4) demonstrate the savings, cost, and performance of the integrated solution in real buildings. The technical approaches are to: 1) select a test system at the University of Oklahoma; 2) develop and implement the algorithms of advanced SF and CC valve controls and validate the performance; 3) develop and implement the advanced OA control using a virtual OA flow meter and validate the performance; 4) demonstrate the savings, cost, and performance of the proposed integrated solution with and without three advanced HVAC controls; and 5) disseminate the project results through publications and presentations. For the SF control, both the gain scheduling and cascade controls can improve the fan energy performance by reducing the fan power during the transient period and the fan control performance at lower speeds by reducing fan speed variation. Moreover, the gain scheduling control provides a simple and low-cost solution and is recommended. The fan power savings can reach 30% in a transient period. For the CC valve control, the gain scheduling control can considerably reduce the supply air temperature oscillation range and frequency under both higher and lower load conditions and the control valve response is much more stable. As a result, the gain scheduling control is recommended. The projected pump energy consumption can be reduced by 68.5%. With the developed virtual OA flow meter, the OA can be accurately controlled at its setpoint, which is determined based on the actual number of occupants in the building provided by occupancy sensors. The RMSE of the proposed OA control is 15.9 L/s. The energy data shows that the fan power and CC cooling energy were significantly reduced. On the other hand, the energy savings majorly results from the occupancy sensors and the energy savings by the advanced HVAC controls is minimal because that the controllers in the test AHU were tuned with very slow response. An annual technical savings potential is estimated as 0.5 quads in the commercial sector.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Parametric System Curves: Correlations Between Fan Pressure Rise and Flow for Large Commercial Buildings

A substantial fraction of HVAC energy use in large commercial buildings is due to fan operation. Fan energy use depends in part on the relationship between system pressure drop and flow through the fan, which is commonly called a "system curve." As a step toward enabling better selections of air-handling system components and analyses of common energy efficiency measures such as duct static pressure reset and duct leakage sealing, this paper shows that a simple four-parameter physical model can be used to define system curves. Our model depends on the square of the fan flow, as is commonly considered. It also includes terms that account for linear-like flow resistances such as filters and coils, and for supply duct leakage when damper positions are fixed or are changed independently of static pressure or fan flow. Only two parameters are needed for systems with variable-position supply dampers (e.g., VAV box dampers modulating to control flow). For these systems, reducing or eliminating supply duct leakage does not change the system curve. The parametric system curve may be most useful when applied to field data. Non-linear techniques could be used to fit the curve to fan pressure rise and flow measurements over a range of operating conditions. During design, when measurements are unavailable, one could use duct design calculation tools instead to determine the coefficients.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Use of an Inertia Sphere to Damp the Angular Motions of Spinning Space Vehicles

A theoretical study was made of a device which might be used to damp the angular motions of spin-stabilized space vehicles with constant moments of inertia. the device was assumed to consist of a rate gyro, a servo control, and a rotor mounted in a single gimbal. The investigation was conducted by considering the general equations of motion of the vehicle-damper system and noting that simplification would result if the damper had a spherical inertia distribution. Such a distribution was assumed thereafter, and a control command was defined so that the gimbal angle would be proportional to the angular velocity of the vehicle about the gimbal axis. The resulting equations were linearized, and the Routh-Hurwitz criterion was applied to determine the conditions for stability. The study included two numerical examples showing possible application of inertia-sphere rate dampers. The general conditions for stability were found to be feasible for practical applications. A simplified stability criterion covers a large class of practical problems.

SPHERE↗

Low-noise flow valve for air ducts

Valve assembly controls air flow from feeder into main duct, with minimum of turbulence, friction, pressure differential, and noise. Valve consists of damper, deflector, and spring. Streamlining of damper and deflector merges flow smoothly, while spring keeps damper and deflector in contact and eliminates valve chatter and damping vibrations.

Gallo, E. A.↗

The motion and stability of a dual spin satellite during the momentum wheel spin-up maneuver

The stability of a dual-spin satellite system during the momentum wheel spin-up maneuver is treated both analytically and numerically. The dual-spin system consists of: a slowly rotating or despun main-body; a momentum wheel (or rotor) which is accelerated by a torque motor to change its initial angular velocity relative to the main part to some high terminal value; and a nutation damper. A closed form solution for the case of a symmetrical satellite indicates that when the nutation damper is physically constrained for movement (i.e. by use of a mechanical clamp) the magnitude of the vector sum of the transverse angular velocity components remains bounded during the wheel spin-up under the influence of a constant motor torque. The analysis is extended to consider such effects as: the motion of the nutation damper during spin-up; a non-uniform motor torque; and the effect of a non-symmetrical mass distribution in the main spacecraft and the rotor. An approximate analytical solution using perturbation techniques is developed for the case of a slightly asymmetric main spacecraft.

Bainum, P. M.↗

The motion and stability of a dual-spin satellite during the momentum wheel spin-up maneuver.

The stability of a dual-spin satellite system during the momentum wheel spin-up maneuver is treated both analytically and numerically. The dual-spin system consists of a slowly rotating or despun main body, a momentum wheel (or rotor) which is accelerated by a torque motor to change its initial angular velocity relative to the main part to some high terminal value, and a nutation damper. A closed-form solution for the case of a symmetrical satellite indicates that when the nutation damper is physically constrained from movement (i.e., by use of a mechanical clamp) the magnitude of the vector sum of the transverse angular velocity components remains bounded during the wheel spin-up under the influence of a constant motor torque. The analysis is extended to consider such effects as the motion of the nutation damper during spin-up, and the effect of a nonsymmetrical mass distribution.

Sen, S.↗

Passive stabilization of the Long Duration Exposure Facility (LDEF)

The results of a study on the application of the magnetically anchored rate damper to gravity gradient stabilization of the Long Duration Exposure Facility (LDEF) are presented. The analyses and simulations required to investigate the use of an existing viscous magnetic rate damper for rate stabilizing the LDEF spacecraft were performed. The following tasks were included: linear performance estimates, capture and damper requirements, and performance prediction. Each of these tasks was performed for two gravity gradient stabilization configurations; an axisymmetric configuration for two-axis (pitch and roll) stability; and a non-axisymmetric configuration for three-axis stability. The results are presented by stabilization configuration.

Das, A.↗

Experimental and analytical dynamic flow characteristics of an axial-flow fan from an air cushion landing system model

An investigation was conducted to compare the steady-state and dynamic flow characteristics of an axial-flow fan which had been used previously as the air supply fan for some model air cushion landing system studies. Steady-state flow characteristics were determined in the standard manner by using differential orifice pressures for the flow regime from free flow to zero flow. In this same regime, a correlative technique was established so that fan inlet and outlet pressures could be used to measure dynamic flow as created by a rotating damper. Dynamic tests at damper frequencies up to 5 Hz showed very different flow characteristics when compared with steady-state flow, particularly with respect to peak pressures and the pressure-flow relationship at fan stall and unstall. A generalized, rational mathematical fan model was developed based on physical fan parameters and a steady-state flow characteristic. The model showed good correlation with experimental tests at damper frequencies up to 5 Hz.

Thompson, W. C.↗

Shock isolator for diode laser operation on a closed-cycle refrigerator

Closed-cycle helium refrigerators are widely used as coolers for semiconductor diode lasers. These refrigerators pose several difficulties including temperature oscillations due to varying refrigerator capacity during the Solvay cycle, and impact shocks delivered to the diode in the cycle's expansion phase. A shock isolator has been designed to isolate diode lasers from such impact shocks. Slow diode current scans have been made before installation of the shock isolator, with the isolator but no thermal damper, and with both devices. With the isolator and no damper, the diode output frequency oscillated at the refrigerator cycle rate, deviating by plus or minus 40 MHz. Using the isolator and the damper no frequency fluctuation was detected.

Jennings, D. E.↗

Development of procedures for calculating stiffness and damping of elastomers in engineering applications, part 7

An elastomer shear damper was designed, tested, and compared with the performance of the T 55 power turbine supported on the production engine roller bearing support. The Viton 70 shear damper was designed so that the elastomer damper could be interchanged with the production T 55 power turbine roller bearing support. The results show that the elastomer sheer dampener permitted stable operation of the power turbine to the maximum operating speed of 16,000 rpm.

Rieger, A.↗

Mechanical design handbook for elastomers

A comprehensive guide for the design of elastomer dampers for application in rotating machinery is presented. Theoretical discussions, a step by step procedure for the design of elastomer dampers, and detailed examples of actual elastomer damper applications are included. Dynamic and general physical properties of elastomers are discussed along with measurement techniques.

Darlow, M.↗

Analysis of an oscillatory oil squeeze film containing a central gas bubble

A squeeze-film damper, consisting of two circular plates, having only normal oscillatory relative motion is considered. The liquid lubricant between the plates is assumed to contain a single central gas bubble. The effect of the bubble on the damper performance is analyzed. Comparison is made with the performance of a pure liquid damper. Substantial deviations in peak dynamic pressures are predicted which explain discrepancies between experimental and theoretical results reported in the literature.

Haber, S.↗