Search NASA⌕ Search

SEARCH · Search NASA

Results for “DATA READOUT SYSTEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Status of the cryogenic inertial reference system for the Gravity Probe B mission

We describe the status of the development and testing program for the inertial reference system for the Gravity Probe B gyroscopes. The gyroscope housings are attached to a cryogenic telescope with a 14 cm aperture that continuously points at a guide star. The star image is split to provide quadrant pointing information which is used to steer the spacecraft. This data is also combined with the gyro readout data to provide an absolute precession measurement. Motion of the guide star is independently checked by reference to background galaxies. Room temperature testing of a prototype telescope has been completed and preparations are being made for low temperature tests.

Lipa, J. A.↗

Cellular telephone-based radiation detection instrument

A network of radiation detection instruments, each having a small solid state radiation sensor module integrated into a cellular phone for providing radiation detection data and analysis directly to a user. The sensor module includes a solid-state crystal bonded to an ASIC readout providing a low cost, low power, light weight compact instrument to detect and measure radiation energies in the local ambient radiation field. In particular, the photon energy, time of event, and location of the detection instrument at the time of detection is recorded for real time transmission to a central data collection/analysis system. The collected data from the entire network of radiation detection instruments are combined by intelligent correlation/analysis algorithms which map the background radiation and detect, identify and track radiation anomalies in the region.

47 OTHER INSTRUMENTATION↗

Cellular telephone-based wide-area radiation detection network

A network of radiation detection instruments, each having a small solid state radiation sensor module integrated into a cellular phone for providing radiation detection data and analysis directly to a user. The sensor module includes a solid-state crystal bonded to an ASIC readout providing a low cost, low power, light weight compact instrument to detect and measure radiation energies in the local ambient radiation field. In particular, the photon energy, time of event, and location of the detection instrument at the time of detection is recorded for real time transmission to a central data collection/analysis system. The collected data from the entire network of radiation detection instruments are combined by intelligent correlation/analysis algorithms which map the background radiation and detect, identify and track radiation anomalies in the region.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Readout and trigger for the AFP detector at ATLAS experiment

AFP, the ATLAS Forward Proton consists of silicon detectors at 205 m and 217 m on each side of ATLAS. In 2016 two detectors in one side were installed. The FEI4 chips are read at 160 Mbps over the optical fibers. The DAQ system uses a FPGA board with Artix chip and a mezzanine card with RCE data processing module based on a Zynq chip with ARM processor running ArchLinux. Finally, in this paper we give an overview of the AFP detector with the commissioning steps taken to integrate with the ATLAS TDAQ. Furthermore first performance results are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Euclid Near Infrared Spectro Photometer instrument concept and first test results obtained for different breadboards models at the end of phase C

The Euclid mission objective is to understand why the expansion of the Universe is accelerating through by mapping the geometry of the dark Universe by investigating the distance-redshift relationship and tracing the evolution of cosmic structures. The Euclid project is part of ESA's Cosmic Vision program with its launch planned for 2020 (ref [1]). The NISP (Near Infrared Spectrometer and Photometer) is one of the two Euclid instruments and is operating in the near-IR spectral region (900- 2000nm) as a photometer and spectrometer. The instrument is composed of: - a cold (135K) optomechanical subsystem consisting of a Silicon carbide structure, an optical assembly (corrector and camera lens), a filter wheel mechanism, a grism wheel mechanism, a calibration unit and a thermal control system - a detection subsystem based on a mosaic of 16 HAWAII2RG cooled to 95K with their front-end readout electronic cooled to 140K, integrated on a mechanical focal plane structure made with molybdenum and aluminum. The detection subsystem is mounted on the optomechanical subsystem structure - a warm electronic subsystem (280K) composed of a data processing / detector control unit and of an instrument control unit that interfaces with the spacecraft via a 1553 bus for command and control and via Spacewire links for science data This presentation describes the architecture of the instrument at the end of the phase C (Detailed Design Review), the expected performance, the technological key challenges and preliminary test results obtained for different NISP subsystem breadboards and for the NISP Structural and Thermal model (STM).

Maciaszek, Thierry↗

Future Experiments with HADES at FAIR

The Dielectron Spectrometer HADES installed at GSI Darmstadt recently provided new intriguing results on production of electron pairs and strangeness from elementary and nucleus-nucleus collisions. The obtained data call for further systematic investigations of heavier systems and/or at higher energies.For this purpose, the HADES spectrometer has been upgraded with a high-granularity RPC time-of-flight wall. In addition, a completely new detector read-out and data-acquisition system has been implemented which will greatly improve our data-taking rates. We describe the current status of the HADES spectrometer and our plans for experiments on heavy system collisions at energies up to 10 A GeV on the upcoming FAIR facility.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A front-end readout Detector Board for the OpenPET electronics system

Here, we present a 16-channel front-end readout board for the OpenPET electronics system. A major task in developing a nuclear medical imaging system, such as a positron emission computed tomograph (PET) or a single-photon emission computed tomograph (SPECT), is the electronics system. While there are a wide variety of detector and camera design concepts, the relatively simple nature of the acquired data allows for a common set of electronics requirements that can be met by a flexible, scalable, and high-performance OpenPET electronics system. The analog signals from the different types of detectors used in medical imaging share similar characteristics, which allows for a common analog signal processing. The OpenPET electronics processes the analog signals with Detector Boards. Here we report on the development of a 16-channel Detector Board. Each signal is digitized by a continuously sampled analog-to-digital converter (ADC), which is processed by a field programmable gate array (FPGA) to extract pulse height information. A leading edge discriminator creates a timing edge that is "time stamped" by a time-to-digital converter (TDC) implemented inside the FPGA. In conclusion, this digital information from each channel is sent to an FPGA that services 16 analog channels, and then information from multiple channels is processed by this FPGA to perform logic for crystal lookup, DOI calculation, calibration, etc.

47 OTHER INSTRUMENTATION↗

Radiometric and Radiation Response of Visible FPAs

The readout integrated circuit (ROIC) used in these devices was originally developed for use in space based infrared systems operating at deep cryogenic temperatures and was selected because of its proven tolerance to total ionizing radiation? The detectors are a 128 x 128 array of 60 pm x 60 pm pixel elements that have been anti-reflection (AR) coated to improve the response at very short wavelengths. These visible focal plane arrays were operated at -40 C (233 K). Two focal planes were characterized using cobalt-60 radiation to produce ionizing total dose damage in the VFPAs. Both operational and performance data were obtained as functions of total dose. The first device tested showed no appreciable change in responsivity or noise up to 300 krad(Si). However, at the next dose level of 600 krad(Si), the readout was non-operational due to failure in the digital circuitry. The second device was characterized to a total dose of 750 krad(Si) with no observed change in responsivity. An increase dark current was observed in both devices, and in the second device, the dark current caused an increase in noise at low irradiance at 400 krad(Si) and above. The increase in dark current was somewhat un-expected for visible PIN detectors. The median dark current increased more than two orders of magnitude at 300 krad(Si) for the first device and a factor of 350 at 750 krad(Si) for pixels near the edge for the second device. The dark current was found to be a strong function of detector bias, with pixels near the edge of the array showing a greater increase in dark current with bias than those near the center. Since the optical response was not a function of bias, it is hypothesized that the dark current is a surface effect and that the variation in dark current with location is due to a variation in pixel bias, caused by a voltage drop across the pixel common lead. As the total dose increased, the dark current and the voltage drop increased

Hubbs, John↗

A drift detector system with anode and cathode readout in the GlueX experiment

A drift detector system designed to detect charged particle tracks in the GlueX experiment dedicated to study the nature of confinement is described. The key design features of the drift chambers associated with the requirement of a minimum material budget in the path of secondary particles are presented. The spatial resolution and the detection efficiency have been measured with cosmic rays using the automatic data acquisition system.

Berdnikov, V V↗

Application of Bayesian Classification to Content-Based Data Management

The high volume of Earth Observing System data has proven to be challenging to manage for data centers and users alike. At the Goddard Earth Sciences Distributed Active Archive Center (GES DAAC), about 1 TB of new data are archived each day. Distribution to users is also about 1 TB/day. A substantial portion of this distribution is MODIS calibrated radiance data, which has a wide variety of uses. However, much of the data is not useful for a particular user's needs: for example, ocean color users typically need oceanic pixels that are free of cloud and sun-glint. The GES DAAC is using a simple Bayesian classification scheme to rapidly classify each pixel in the scene in order to support several experimental content-based data services for near-real-time MODIS calibrated radiance products (from Direct Readout stations). Content-based subsetting would allow distribution of, say, only clear pixels to the user if desired. Content-based subscriptions would distribute data to users only when they fit the user's usability criteria in their area of interest within the scene. Content-based cache management would retain more useful data on disk for easy online access. The classification may even be exploited in an automated quality assessment of the geolocation product. Though initially to be demonstrated at the GES DAAC, these techniques have applicability in other resource-limited environments, such as spaceborne data systems.

Lynnes, Christopher↗

10 Boron-film-based gas detectors at ESS

The development of detectors for the European Spallation Source is an important parallel element to the effort put into the design and construction of the neutron source and instruments. The 10Boron-film-based detector developments that started over a decade ago as basic detector concepts have now reached technical maturity after intense prototyping work and numerous testing campaigns. Several of the ESS beamlines that will soon enter the commissioning phase started welcoming the detector systems built with the 10 B-film converter technology. The real-size demonstrators evolved in the last 2–3 years into a diverse suite of gas proportional counters for use in diffraction, reflectometry and small-angle scattering studies in spite of the operational complexity posed by the requirements for large-area coverage, low material budget and robustness for operation in the high-flux and high-radiation environment of ESS. The detectors are now being shipped to ESS or undergoing the last performance and calibration tests before being handed over to the instrument teams for installation in the host beamlines. A common feature of these detector systems is the very large number of readout channels that they are instrumented with in order to fulfill the demanding requirements for sensitivity, spatial resolution and count-rate capability. Across all of the detector types that will operate at ESS, the integration, testing and commissioning of the read-out technologies and software tools for data reduction, calibration and analysis are the focus of the detector and integration teams. These will yield a wealth of knowledge about their operation as well as initial results on the in-situ performance, a very important asset to ensure rapid commissioning of the detectors when neutrons from the ESS source become available. In this paper we will give an overview of the 10 B-film-based detector technologies included in the ESS detector suite that are currently facing the transition from the production phase to installation and integration with the other beamline components, which comes with its own specific challenges of both organizational and technical nature.

47 OTHER INSTRUMENTATION↗

Monitoring Composite Material Pressure Vessels with a Fiber-Optic/Microelectronic Sensor System

We discuss the concept of an integrated, fiber-optic/microelectronic distributed sensor system that can monitor composite material pressure vessels for Air Force space systems to provide assessments of the overall health and integrity of the vessel throughout its entire operating history from birth to end of life. The fiber optic component would include either a semiconductor light emitting diode or diode laser and a multiplexed fiber optic sensing network incorporating Bragg grating sensors capable of detecting internal temperature and strain. The microelectronic components include a power source, a pulsed laser driver, time domain data acquisition hardware, a microprocessor, a data storage device, and a communication interface. The sensing system would be incorporated within the composite during its manufacture. The microelectronic data acquisition and logging system would record the environmental conditions to which the vessel has been subjected to during its storage and transit, e.g., the history of thermal excursions, pressure loading data, the occurrence of mechanical impacts, the presence of changing internal strain due to aging, delamination, material decomposition, etc. Data would be maintained din non-volatile memory for subsequent readout through a microcomputer interface.

Klimcak, C.↗

Prototypes and system test stands for the Phase 1 upgrade of the CMS pixel detector

The CMS pixel phase-1 upgrade project replaces the current pixel detector with an upgraded system with faster readout electronics during the extended year-end technical stop of 2016/2017. New electronics prototypes for the system have been developed, and tests in a realistic environment for a comprehensive evaluation are needed. A full readout test stand with either the same hardware as used in the current CMS pixel detector or the latest prototypes of upgrade electronics has been built. The setup enables the observation and investigation of a jitter increase in the data line associated with trigger rate increases. This effect is due to the way in which the clock and trigger distribution is implemented in CMS. A new prototype of the electronics with a PLL based on a voltage controlled quartz crystal oscillator (QPLL), which works as jitter filter, in the clock distribution path was produced. With the test stand, it was confirmed that the jitter increase is not seen with the prototype, and also good performance was confirmed at the expected detector operation temperature ($-$20 °C).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The CMS Event Builder and Storage System

The CMS event builder assembles events accepted by the first level trigger and makes them available to the high-level trigger. The event builder needs to handle a maximum input rate of 100 kHz and an aggregated throughput of 100 GB/s originating f rom approximately 500 sources. This paper presents the chosen hardware and software architecture. The system consists of 2 stages: an initial pre-assembly reducing the number of fragments by one order of magnitude and a final assembly by several independe nt readout builder (RU-builder) slices. The RU-builder is based on 3 separate services: the buffering of event fragments during the assembly, the event assembly, and the data flow manager. A further component is responsible for handling events accepted by the high-level trigger: the storage manager (SM) temporarily stores the events on disk at a peak rate of 2 GB/s until they are permanently archived offline. In addition, events and data-quality histograms are served by the SM to online monitoring clients . We discuss the operational experience from the first months of reading out cosmic ray data with the complete CMS detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Real-Time Simultaneous 3D Volumetric Imaging and Mapping of Gamma-ray and Neutron Sources

The invention combines radiation detection instrumentation, data processing algorithms, and visualization software to enable, for the first time ever, simultaneous, real-time imaging of both gamma ray and neutron sources (fast and slow). Radiation detectors sensitive to gamma rays and neutrons are integrated with readout electronics that allow discriminated particles to be incorporated into real-time 3D volumetric reconstructions as two separate data streams. Using the Scene Data Fusion (SDF) conceptual framework and contextual sensors from the Localization and Mapping Platform (LAMP) developed at LBNL, gamma-ray and neutron data are fused onto contextual information from the environment around the detection system. The invention is compatible with radiation detection media capable of detecting and discriminating between gamma rays and neutrons or the pairing of multiple detectors separately capable of detecting gamma rays and/or neutrons. It can be integrated into a compact, lightweight imaging platform for operation as a hand-carry device, on unmanned aerial systems, and with unmanned vehicles. The ability to measure neutron enables the detection and 3D localization of shielded nuclear materials such as Pu-239 which is not possible with means of gamma-ray detection and spectroscopy overcoming of major limitation in the detection of such materials to-date.

Cates, Joshua↗

New techniques of low level environmental radiation monitoring at JLab

We present the first long-term environmental radiation monitoring results obtained using the technique of pulse mode readout for the industry-standard Reuter-Stokes RSS-1013 argon-filled high pressure ionization chambers (HPIC). With novel designs for the front-end electronics readout and customized signal processing algorithms, we are capable of detecting individual events of gas ionization in the HPIC, caused by interactions of gammas and charged particles in the gas. The technique provides enough spectroscopic information to distinguish between several different types of environmental and man-made radiation. The technique also achieves a high degree of sensitivity and stability of the data, allowing long-term environmental radiation monitoring with unprecedented precision.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiation hardness of the storage phosphor europium doped potassium chloride for radiation therapy dosimetry

Purpose: An important property of a reusable dosimeter is its radiation hardness, that is, its ability to retain its dosimetric merits after irradiation. The radiation hardness of europium doped potassium chloride (KCl:Eu{sup 2+}), a storage phosphor material recently proposed for radiation therapy dosimetry, is examined in this study. Methods: Pellet-style KCl:Eu{sup 2+} dosimeters, 6 mm in diameter, and 1 mm thick, were fabricated in-house for this study. The pellets were exposed by a 6 MV photon beam or in a high dose rate {sup 137}Cs irradiator. Macroscopic properties, such as radiation sensitivity, dose response linearity, and signal stability, were studied with a laboratory photostimulated luminescence (PSL) readout system. Since phosphor performance is related to the state of the storage centers and the activator, Eu{sup 2+}, in the host lattice, spectroscopic and temporal measurements were carried out in order to explore radiation-induced changes at the microscopic level. Results: KCl:Eu{sup 2+} dosimeters retained approximately 90% of their initial signal strength after a 5000 Gy dose history. Dose response was initially supralinear over the dose range of 100-700 cGy but became linear after 60 Gy. Linearity did not change significantly in the 0-5000 Gy dose history spanned in this study. Annealing high dose history chips resulted in a return of supralinearity and a recovery of sensitivity. There were no significant changes in the PSL stimulation spectra, PSL emission spectra, photoluminescence spectra, or luminescence lifetime, indicating that the PSL signal process remains intact after irradiation but at a reduced efficiency due to reparable radiation-induced perturbations in the crystal lattice. Conclusions: Systematic studies of KCl:Eu{sup 2+} material are important for understanding how the material can be optimized for radiation therapy dosimetry purposes. The data presented here indicate that KCl:Eu{sup 2+} exhibits strong radiation hardness and lends support for further investigations of this novel material.

36 MATERIALS SCIENCE↗

To perform a gyro test of general relativity in a satellite and develop associated control technology

A satellite configuration having two gyroscopes with axes parallel to the boresight of a telescope and two at right angles to the telescope and approximately parallel and perpendicular to the earth's axis is proposed for measuring geodetic precessions due to the earth's motion about the sun, higher order geodetic terms calculated from the earth's quadrapole mass moment (0.010 arc-sec/year in a 400 nautical mile polar orbit), and deflection by the sun of the starlight signal for the reference telescope. Data from the experiment also contain large periodic signals due to the annual and orbital aberrations of starlight which are useful in providing a built in reference signal of known amplitude for scaling the relativity signals, and should yield a singularly precise measurement of the parallax of the reference star. The development of the gyroscope and its readout system are discussed, as well as signal integration, drag-free control, and attitude control.

Fairbank, W. M.↗