Search NASA⌕ Search

SEARCH · Search NASA

Results for “DOGS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Pattern of filling in the pulmonary capillary bed.

Artificially ventilated and perfused dog lungs were rapidly frozen under various physiological conditions. In 2-micron-thick sections the number of red blood cells (RBCs) per 10-micron length of alveolar septum was counted. Under conditions in which alveolar pressure exceeded venous pressure, variation in RBC concentration within areas supplied by single arterioles accounted completely for variation between areas supplied by different arterioles. Except at very high perfusion pressures when venous pressure exceeded alveolar pressure, there was no significant correlation between RBC concentrations of pairs of adjacent septa.

Warrell, D. A.↗

Effect of stratified inequality of blood flow on gas exchange in liquid-filled lungs.

This investigation set out to answer two questions: (1) are the distal alveoli in the terminal lung units less well perfused than the proximal alveoli, i.e., is there stratification of blood flow; and (2) if so, does this enhance gas exchange in the presence of stratified inequality of ventilation. Excised dog lungs were ventilated with saline and perfused with blood. Following single inspirations of xenon 133 in saline and various periods of breath holding, the expired xenon concentration against volume was measured and it confirmed marked stratified inequality of ventilation under these conditions. By measuring the rate of depletion of xenon from alveoli during a period of blood flow, we showed that the alveoli which emptied at the end of expiration had 16% less blood flow than those exhaling earlier. However, by measuring the xenon concentration in pulmonary venous blood, we found that about 10% less tracer was transferred from the alveoli into the blood when the inspired xenon was stratified within the respiratory zone. Thus while stratification of blood flow was confirmed, it was shown to impair rather than enhance the efficiency of gas transfer.

West, J. B.↗

Liquid breathing - Prevention of pulmonary arterial-venous shunting during acceleration.

Dependent pulmonary atelectasis, arterial-venous shunting, and downward displacement of the heart caused by the gravitational-inertial force environment were prevented in dogs breathing oxygenated liquid fluorocarbon in a whole-body water-immersion respirator. Partial closure of the major airways during part of the expiratory phase of liquid respiration was a significant problem initially but was minimized in subsequent studies.

Sass, D. J.↗

Autonomic control of cardiac function and myocardial oxygen consumption during hypoxic hypoxia.

Investigation in 19 conscious dogs of the importance of the sympathetic nervous system in the coronary and cardiac response to altitude (hypoxic) hypoxia. Beta-adrenergic blockade was used to minimize the cardiac effect associated with sympathetic receptors. It is shown that the autonomic nervous system, and particularly the sympathetic nervous system, is responsible for the increase in ventricular function and myocardial oxygen consumption that occurs during hypoxia. Minimizing this response through appropriate conditioning and training may improve the operating efficiency of the heart and reduce the hazard of hypoxia and other environmental stresses, such as acceleration, which are encountered in advanced aircraft systems.

Erickson, H. H.↗

Angiographic analysis of heart geometry.

Basic steps in the acquisition and reconstruction of cardiac dimensions obtained from angiocardiograms for spatial reconstruction and analysis are described, and example applications include a reconstruction of the human left ventricle and a study of the motion of the free wall of the right ventricle in a dog. Computer analysis of the spatial motion of implanted tantalum markers is discussed along with corrections for distortion and magnification incurred in the process. Graphics display of three-dimensional ventricle models is examined, and future improvements in angiocardiographic studies are considered.

Sandler, H.↗

CPPB and vasopressin secretion.

Discussion of the role of vasopressin (or 'antidiuretic hormone') secretory control system in the maintenance of central vascular volume, and critical comments about the latest paper by Barratz et al. (1971) on the interrelation of antidiuretic hormone (ADH) and fluid balance during continuous positive pressure breathing (CPPB) in dogs. It is felt that, while the increase in plasma ADH levels occurring with CPPB has been more carefully defined in this last paper than previously, still more accurate definitions could be obtained under experimental conditions modified in accordance with presented suggestions.

Moran, W. H., Jr.↗

Prolonged weightlessness (300 plus days) and cardiac performance in primates. 1: Neuro-humoral mechanisms in the control of cardiac and vascular performance in conscious animals

Research during the period 1 Oct. 1971 to 1 Oct. 1972 is reported. Studies discussed include: development of techniques for instrumentation of dogs and other animals, effects of temporary application of lower body negative pressure, and effect of infusing selected drugs on ventricular performance.

Hawthorne, E. W.↗

Continuous exposure of animals to methylisobutylketone

Continuous exposure of dogs, monkeys, mice, and rats to MIBK for two weeks and all animals except mice for 90 days resulted in measurable adverse effects only in the case of rats. Rat kidney weights and kidney to body weight ratios were significantly elevated after exposure to 410 mg/cu m for two weeks, and kidney and liver organ weights and organ to body weight ratios were elevated after exposure to 820 mg/cu m for two weeks and to 410 mg/cu m for 90 days.

Vernot, E. H.↗

Indirect Blood Pressure Measuring Device

Design and performance of a blood pressure recording device for pediatric use are reported. A strain gage transducer with a copper-beryllium strip as force sensing element is used to monitor skin movements and to convert them into electrical signals proportional to those displacements. Experimental tests with this device in recording of force developed above the left femoral artery of a dog accurately produced a blood pressure curve.

Hum, L.↗

Influence of flow and pressure on wave propagation in the canine aorta.

Data on wave speed acquired from 20 anesthetized dogs showed that the thoracic aorta was essentially nondispersive for small artificially generated pressure waves traveling in the downstream or the upstream direction and having frequencies between 40 and 120 Hz. The amplitude of these waves decayed exponentially with the distance traveled. Theoretical studies are cited which have shown that changes in wave speed due to variations in pressure and flow produce marked nonlinear effects in hemodynamics.

Histand, M. B.↗

Transducer technology transfer to bio-engineering applications

The results of a technology transfer of a miniature unidirectional stress transducer, developed for experimental stress analysis in the aerospace field, to applications in bioengineering are reported. By modification of the basic design and innovations in attachment techniques, the transducer was successfully used in vivo on the myocardium of large dogs to record the change in contractile force due to coronary occlusion, reperfusion, and intervention.

Duran, E. N.↗

Study of blood flow sensing with microwave radiometry

A study and experimental investigation has been performed to determine the feasibility of measuring regional blood flow and volume in man by means of microwave radiometry. An indication was expected of regional blood flow from measurement of surface and subsurface temperatures with a sensitive radiometer. Following theoretical modeling of biological tissue, to determine the optimum operating frequency for adequate sensing depth, a sensitive microwave radiometer was designed for operation at 793 MHz. A temperature sensitivity of of 0.06 K rms was realized in this equipment. Measurements performed on phantom tissue models, consisting of beef fat and lean beefsteak showed that the radiometer was capable of sensing temperatures from a depth between 3.8 and 5.1 cm. Radiometric and thermodynamic temperature measurements were also performed on the hind thighs of large dogs. These showed that the radiometer could sense subsurface temperatures from a depth of, at least, 1.3 cm. Delays caused by externally-generated RF interference, coupled with the lack of reliable blood flow measurement equipment, prevented correlation of radiometer readings with reginal blood flow. For the same reasons, it was not possible to extend the radiometric observations to human subjects.

Porter, R. A.↗

Evaluation of possible interaction among drugs contemplated for use during manned space flights

Possible interactions among drugs contemplated for use during manned spaceflights have been studied in several animal species. The following seven drugs were investigated: nitrofurantoin, chloral hydrate, hexobarbital, phenobarbital, flurazepam, diphenoxylate, and phenazopyridine. Particular combinations included: chloral hydrate, hexabarbital or flurazepam with nitrofurantoin; phenobarbital or flurazepam with phenazopyridine; and diphenoxylate with two does formulations of nitrofurantoin. Studies were carried out in several species to determine whether induction of liver microsomal enzymes would increase the tendency of phenazopyridine to produce methemoglobin in vivo. Animals were premedicated with phenobarbital, a known inducer of azoreductase, and in a separate experiment with flurazepam, before administration of phenazopyridine. Methemoglobin production was determined in each animal after receiving phenazopyridine. No evidence was found for increased production of methemoglobin in the rat, dog, or rabbit that could be attributed to increased amounts of microsomal enzymes.

Source record↗

Brain blood-flow changes during motion sickness

The possibility of diminished blood flow in the brain is studied as one of the factors resulting from an increase in skeletal muscle blood volume concomitant with other characteristics of motion sickness. Thermistors are implanted in the thalamus of dogs and blood flow changes are recorded while they are subjected to sinusoidal movement on a two pole swing. Results of these initial steps in a proposed long term exploration of different areas of the brain are presented.

Johnson, W. H.↗

Venous return curves obtained from graded series of valsalva maneuvers

The effects were studied of a graded series of valsalva-like maneuvers on the venous return, which was measured transcutaneously in the jugular vein of an anesthetized dog, with the animal serving as its own control. At each of five different levels of central venous pressure, the airway pressure which just stopped venous return during each series of maneuvers was determined. It was found that this end-point airway pressure is not a good estimator of the animal's resting central venous pressure prior to the simulated valsalva maneuver. It was further found that the measured change in right atrial pressure during a valsalva maneuver is less than the change in airway pressure during the same maneuver, instead of being equal, as had been expected. Relative venous return curves were constructed from the data obtained during the graded series of valsalva maneuvers.

Mastenbrook, S. M., Jr.↗

A study of the biological effect of continuous inhalation exposure of 1, 1, 1-trichloroethene (methyl chloroform) on animals

The effects of continuous exposure to 1,1,1-trichloroethane on hepatic morphology and function are evaluated and compared with those produced by methylene chloride (dichloromethane) to determine environmental concentrations of each compound that would produce a similar biological response, i.e., a comparable increase in liver triglycerides over control levels. Experimental findings on mice, rats, dogs, and monkeys indicate that the pathological alternations observed with 1,1,1-trichloroethane are similar to those observed with dichloromethane except for different time courses of the effects and different degrees of recovery. A ten fold greater atmospheric concentration of 1,1,1-trichloroethane is required to produce the minimal liver changes found at 100 ppm dichloromethane.

Macewen, J. D.↗

Ultrasonic Doppler measurement of renal artery blood flow

Implantable pulsed Doppler ultrasonic flowmeter development has resulted in designs for application to the aortas of dogs and humans, and to human renal and coronary arteries. A figure of merit was derived for each design, indicating the degree of its precision. An H-array design for transcutaneous observation of blood flow was developed and tested in vitro. Two other simplified designs for the same purpose obviate the need to determine vessel orientation. One of these will be developed in the next time period. Techniques for intraoperative use and for implantation have had mixed success. While satisfactory on large vessels, higher ultrasonic frequencies and alteration of transducer design are required for satisfactory operation of pulsed Doppler flowmeters with small vessels.

Source record↗

Role of atrial receptors in the control of sodium excretion

Responses of an innervated and a contralateral chronically denervated kidney to mild positive pressure breathing are compared for saline volume expansions in chloralose anesthetized dogs. It is shown that mild pressure breathing significantly reduces sodium excretion, urine flow, free water clearance, and PAH clearance. After 20 minutes of positive pressure breathing, both kidney responses are identical suggesting the release of natriuretic hormone which reduces renal function in addition to the demonstrated change in renal nerve activity. Increase of the left atrial pressure through balloon obstruction of the mitral orifice increases urine flow, sodium excretion and PAH clearance; inflation of the balloon and positive pressure breathing again depresses renal function. Preliminary evidence indicates that receptors in the right atrium are more severely affected by pressure breathing than those in the left atrium.

Meehan, J. R.↗