Search NASA⌕ Search

SEARCH · Search NASA

Results for “Detection Limit”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Pulse Stripping Analysis: A Technique for Determination of Some Metals in Aerosols and Other Limited Size Samples

A technique for determining lead with a detection limit down to a nanogram on limited size samples is described. The technique is an electrochemical one and involves pre-concentration of the metal species in a mercury drop. Although the emphasis in this paper is on the determination of lead, many metal ion species which are reducible to the metal at an electrode are equally determinable. A technique called pulse polarography is proposed to determine the metals in the drop and this technique is discussed and is compared with other techniques. Other approaches for determination of lead are also compared. Some data are also reported for the lead content of Ventura County particulates. The characterization of lead species by solubility parameters is discussed.

Parry, Edward P.↗

Nanosensors based on functionalized nanoparticles and surface enhanced raman scattering

Surface-Enhanced Raman Spectroscopy (SERS) is a vibrational spectroscopic technique that utilizes metal surfaces to provide enhanced signals of several orders of magnitude. When molecules of interest are attached to designed metal nanoparticles, a SERS signal is attainable with single molecule detection limits. This provides an ultrasensitive means of detecting the presence of molecules. By using selective chemistries, metal nanoparticles can be functionalized to provide a unique signal upon analyte binding. Moreover, by using measurement techniques, such as, ratiometric received SERS spectra, such metal nanoparticles can be used to monitor dynamic processes in addition to static binding events. Accordingly, such nanoparticles can be used as nanosensors for a wide range of chemicals in fluid, gaseous and solid form, environmental sensors for pH, ion concentration, temperature, etc., and biological sensors for proteins, DNA, RNA, etc.

Talley, Chad E↗

Monitoring/Verification using DMS: TATP Example

Field-rugged and field-programmable differential mobility spectrometry (DMS) networks provide highly selective, universal monitoring of vapors and aerosols at detectable levels from persons or areas involved with illicit chemical/biological/explosives (CBE) production. CBE sensor motes used in conjunction with automated fast gas chromatography with DMS detection (GC/DMS) verification instrumentation integrated into situational operations management systems can be readily deployed and optimized for changing application scenarios. The feasibility of developing selective DMS motes for a 'smart dust' sampling approach with guided, highly selective, fast GC/DMS verification analysis is a compelling approach to minimize or prevent the use of explosives or chemical and biological weapons in terrorist activities. Two peroxide-based liquid explosives, triacetone triperoxide (TATP) and hexamethylene triperoxide diamine (HMTD), are synthesized from common chemicals such as hydrogen peroxide, acetone, sulfuric acid, ammonia, and citric acid (Figure 1). Recipes can be readily found on the Internet by anyone seeking to generate sufficient quantities of these highly explosive chemicals to cause considerable collateral damage. Detection of TATP and HMTD by advanced sensing systems can provide the early warning necessary to prevent terror plots from coming to fruition. DMS is currently one of the foremost emerging technologies for the separation and detection of gas-phase chemical species. This is due to trace-level detection limits, high selectivity, and small size. DMS separates and identifies ions at ambient pressures by utilizing the non-linear dependence of an ion's mobility on the radio frequency (rf) electric field strength. GC is widely considered to be one of the leading analytical methods for the separation of chemical species in complex mixtures. Advances in the technique have led to the development of low-thermal-mass fast GC columns. These columns are capable of completing runs in less than 3 minutes. Fast GC columns are also more compact than their traditional counterparts. An earlier collaborative effort involving these authors optimized a handheld, fast GC/DMS, equipped with a non-rad ionization source, for the detection of TATP (Figure 2). The unit combines the separation capabilities of GC with the selectivity of DMS. Analytes are identified both by their elution time from the column and by the characteristic response in the DMS spectrum. Analysis times required to obtain results for these analytes are approximately 80 seconds for TATP and 160 seconds for HMTD (Figure 3). The limit of detection for both TATP and HMTD is approximately 1 ng/{micro}L. Substances that could interfere with the detection of peroxide-based explosives have been studied. Both the GC elution time and the DMS spectral peak locations were unique and do not hinder the detection of either TATP or HMTD.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of Uranium Measurements in Water by Various Methods - 13571

In December 2000, EPA amended its drinking water regulations for radionuclides by adding a Maximum Contaminant Level (MCL) for uranium (so called MCL Rule)[1] of 30 micrograms per liter (μg/L). The MCL Rule also included MCL goals of zero for uranium and other radionuclides. Many radioactively contaminated sites must test uranium in wastewater and groundwater to comply with the MCL rule as well as local publicly owned treatment works discharge limitations. This paper addresses the relative sensitivity, accuracy, precision, cost and comparability of two EPA-approved methods for detection of total uranium: inductively plasma/mass spectrometry (ICP-MS) and alpha spectrometry. Both methods are capable of measuring the individual uranium isotopes U-234, U- 235, and U-238 and both methods have been deemed acceptable by EPA. However, the U-238 is by far the primary contributor to the mass-based ICP-MS measurement, especially for naturally-occurring uranium, which contains 99.2745% U-238. An evaluation shall be performed relative to the regulatory requirement promulgated by EPA in December 2000. Data will be garnered from various client sample results measured by ALS Laboratory in Fort Collins, CO. Data shall include method detection limits (MDL), minimum detectable activities (MDA), means and trends in laboratory control sample results, performance evaluation data for all methods, and replicate results. In addition, a comparison will be made of sample analyses results obtained from both alpha spectrometry and the screening method Kinetic Phosphorescence Analysis (KPA) performed at the U.S. Army Corps of Engineers (USACE) FUSRAP Maywood Laboratory (UFML). Many uranium measurements occur in laboratories that only perform radiological analysis. This work is important because it shows that uranium can be measured in radiological as well as stable chemistry laboratories and it provides several criteria as a basis for comparison of two uranium test methods. This data will indicate which test method is the most accurate and most cost effective. This paper provides a benefit to Formerly Utilized Sites Remedial Action Program (FUSRAP) and other Department of Defense (DOD) programs that may be performing uranium measurements. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Closing in on mass-degenerate dark matter scenarios with antiprotons and direct detection

Over the last years both cosmic-ray antiproton measurements and direct dark matter searches have proved particularly effective in constraining the nature of dark matter candidates. The present work focusses on these two types of constraints in a minimal framework which features a Majorana fermion as the dark matter particle and a scalar that mediates the coupling to quarks. Considering a wide range of coupling schemes, we derive antiproton and direct detection constraints using the latest data and paying close attention to astrophysical and nuclear uncertainties. Both signals are strongly enhanced in the presence of degenerate dark matter and scalar masses, but we show that the effect is especially dramatic in direct detection. Accordingly, the latest direct detection limits take the lead over antiprotons. We find that antiproton and direct detection data set stringent lower limits on the mass splitting, reaching 19% at a 300 GeV dark matter mass for a unity coupling. Interestingly, these limits are orthogonal to ongoing collider searches at the Large Hadron Collider, making it feasible to close in on degenerate dark matter scenarios within the next years.

79 ASTRONOMY AND ASTROPHYSICS↗

Zinc Oxide–Graphene Nanocomposite-Based Sensor for the Electrochemical Determination of Cetirizine

A nanocomposite electrode of graphene (Gr) and zinc oxide (ZnO) nanoparticles was fabricated to study the electrochemical oxidation behavior of an anti-inflammatory drug, i.e., cetirizine (CET). The voltametric response of CET for bare CPE, Gr/CPE, ZnO/CPE, and the ZnO-Gr nanocomposite electrode was studied. The modifier materials were characterized using scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDS), and X-ray powder diffraction (XRD) to comprehend the surface morphology of the utilized modifiers. The influence of pH, scan rate, and accumulation time on the electrooxidation of CET was examined. It was found that the electrochemical oxidation of CET was diffusion-controlled, in which two protons and two electrons participated. The detection limit was found to be 2.8 × 10 -8 M in a linearity range of 0.05–4.0 µM. Study of excipients was also performed, and it was found that they had negligible interference with the peak potential of CET. The validation and utility of the fabricated nanocomposite sensor material were examined by analyzing clinical and biological samples. Stability testing of the nanocomposite electrode was conducted to assess the reproducibility, determining that the developed biosensor has good stability and high efficiency in producing reproducible results.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

THE MISSING WEAK LENSING MASS IN A781

Measuring cluster masses accurately is important for testing the cosmological paradigm. Weak lensing is one of the most promising methods for detecting, measuring, and calibrating cluster mass estimates made using other mass proxies (e.g., X-ray, Sunyaev-Zel'dovich effect, spectroscopy). However, it is still essential to characterize and understand the causes of systematic error and bias in weak lensing measurements. A781D is a cluster of galaxies with a mass and redshift that places it well within the theoretical detection limits of weak lensing analyses from the ground yet has evaded detection in previous weak lensing studies. Previous weak lensing measurements in the region surrounding this cluster from the Deep Lens Survey were unable to detect it and placed a 1{sigma} limit on the mass of <5 Multiplication-Sign 10{sup 13} M{sub Sun }. Given independent estimates of the cluster mass by X-ray and spectroscopic measurements and its spectroscopically confirmed redshift of 0.43, it is difficult to explain its absence from the weak lensing mass reconstructions. We re-analyzed this cluster using imaging from the Orthogonal Parallel Transfer Imaging Camera and archival Suprime-Cam data. We successfully detect A781A in both analyses, but A781D remains undetected. We use these two new independent analyses to rule out systematic effects from the telescope, instrument, and point-spread function correction as the cause of the null detection. We also demonstrate the first use of an orthogonal transfer camera for weak lensing analysis and demonstrate its suitability for weak lensing studies.

79 ASTRONOMY AND ASTROPHYSICS↗

All-aerosol-jet-printed highly sensitive and selective polyaniline-based ammonia sensors: a route toward low-cost, low-power gas detection

In this work, we report the design and scalable fabrication of a low-cost and low-power polyaniline-based (PANI) ammonia (NH3) gas sensor on polyimide (PI) substrates using additive manufacturing techniques. The silver interdigitated electrode (IDE) arrays and conducting polymer films are printed onto PI using a direct-write technology of aerosol-jet printing. Morphological characteristics are examined by scanning electron microscopy and energy-dispersive X-ray analysis which reveal homogeneously printed PANI film on the IDE platform. The gas sensing performance is evaluated in the analytical early leak detection range of 5–1000 ppm NH3 in air as a function of both thermal (23 °C, 50 °C, 80 °C) and relative humidity (RH = 0%, 30%, 50%) exposures. The sensor exhibits sensitivity down to 5 ppm NH3 with a sub-ppm detection limit and good repeatability. We observe rapid NH3 detection at 0% RH with very extended times for equilibration and recovery. However, at both 30 and 50% RH, the room temperature response and recovery times are reduced to only about 1 min and 5 min, respectively. Experiments also reveal good sensitivity toward the analyte even at higher operating temperatures. Present results merit the practical application of aerosol-jet-printed, low-power sensors for industrial applications where low-level hazardous gas detection is essential.

36 MATERIALS SCIENCE↗

Selective fluorescence sensors for detection of nitroaniline and metal Ions based on ligand-based luminescent metal-organic frameworks

Metal-organic frameworks (MOFs) are porous crystalline materials with high potential for applications in fluorescence sensors. In this work, two solvent-induced Zn(II)–based metal-organic frameworks, Zn{sub 3}L{sub 3}(DMF){sub 2} (1) and Zn{sub 3}L{sub 3}(DMA){sub 2}(H{sub 2}O){sub 3} (2) (L=4,4′-stilbenedicarboxylic acid), were investigated as selective sensing materials for detection of nitroaromatic compounds and metal ions. The sensing experiments show that 1 and 2 both exhibit selective fluorescence quenching toward nitroaniline with a low detection limit. In addition, 1 exhibits high selectivity for detection of Fe{sup 3+} and Al{sup 3+} by significant fluorescence quenching or enhancement effect. While for 2, it only exhibits significant fluorescence quenching effect for Fe{sup 3+}. The results indicate that 1 and 2 are both promising fluorescence sensors for detecting and recognizing nitroaniline and metal ions with high sensitivity and selectivity. - Graphical abstract: Two MOFs have been selected as the fluorescence sensing materials for selectively sensing mitroaromatic compounds and metal ions. The high selectivity makes them promising fluorescence sensors for detecting and recognizing nitroaniline and Fe{sup 3+} or Al{sup 3+}.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Flexible and freestanding catalase-Fe3O4/reduced graphene oxide paper: Enzymatic hydrogen peroxide sensor applications

Highlights: • The preparation of a new type of flexible Cat-Fe{sub 3}O{sub 4}/rGO paper was achieved by a simple method. • The characterization of the Fe{sub 3}O{sub 4} nanocrystals formed on rGO and Cat-Fe{sub 3}O{sub 4}/rGO paper were investigated by several techniques. • Cat-Fe{sub 3}O{sub 4}/rGO paper electrode was used as a flexible electrochemical sensor for H{sub 2}O{sub 2} determination. - Abstract: We proposed a new type of freestanding Catalase (EC 1.11.1.6) (Cat) modified paper electrode based on Fe{sub 3}O{sub 4} crystals decorated freestanding reduced graphene oxide (rGO) paper (Cat-Fe{sub 3}O{sub 4}/rGO) using a facile electrodeposition method. This enzyme modified paper electrode was used for the specific determination of hydrogen peroxide (H{sub 2}O{sub 2}). Structural, chemical, and morphological characterization of the Fe{sub 3}O{sub 4} crystals formed on rGO paper was investigated by (i) using scanning electron microscopy (SEM), (ii) energy-dispersive X-ray spectroscopy (EDS), (iii) X-ray photoelectron spectroscopy (XPS), (iv) X-ray diffraction spectroscopy (XRD), (v) Raman spectroscopy, (vi) electrochemical impedance spectroscopy (EIS) and (vii) cyclic voltammetry (CV) techniques. The Cat enzyme was successfully adsorbed on the Fe{sub 3}O{sub 4} nanocrystals surface which was demonstrated by fluorescence microscopy. The Cat-Fe{sub 3}O{sub 4}/rGO paper electrode showed excellent electrocatalytic activity toward H{sub 2}O{sub 2}. It is found that Cat-Fe{sub 3}O{sub 4}/rGO paper electrode shows a wide linear range, high sensitivity, and a low detection limit for H{sub 2}O{sub 2} detection.

36 MATERIALS SCIENCE↗

Copper-Based Two-Dimensional Conductive Metal–Organic Framework Thin Films for Ultrasensitive Detection of Perfluoroalkyls in Drinking Water

Perfluoroalkyls (PFAS) continue to emerge as a global health threat making their effective detection and capture extremely important. Though metal–organic frameworks (MOFs) have stood out as a promising class of porous materials for sensing PFAS, detection limits remain insufficient and a fundamental understanding of detection mechanisms warrants further investigation. Here, in this study, we show the use of a 2D conductive MOF film based on copper hexahydroxy triphenylene (Cu-HHTP) to fabricate chemiresistive sensing devices for detecting PFAS in drinking water. We further show ultrasensitive detection using electrochemical impedance spectroscopy. Owing to excellent electrostatic attractions and electrochemical interactions between the copper-based MOF and PFAS, confirmed by high-resolution spectroscopy and theoretical simulations, the MOF-based sensor reported herein exhibits excellent affinity and sensitivity toward perfluorinated acids at concentrations as low as 0.002 ng/L.

2D metal−organic frameworks↗

Mapping Irreversible Electrochemical Processes on the Nanoscale: Ionic Phenomena in Li-ion Conductive Glass Ceramics

A scanning probe microscopy approach for mapping local irreversible electrochemical processes based on detection of bias-induced frequency shifts of cantilevers in contact with the electrochemically active surface is demonstrated. Using Li-ion conductive glass ceramic as a model, we demonstrate near unity transference numbers for ionic transport and establish detection limits for current-based and strain based detection. The tip-induced electrochemical process is shown to be a first order transformation and nucleation potential is close to the Li-metal reduction potential. Spatial variability of the nucleation bias is explored and linked to the local phase composition. These studies both provide insight into nanoscale ionic phenomena in practical Li-ion electrolyte, and also open pathways for probing irreversible electrochemical, bias-induced, and thermal transformations in nanoscale systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

THE VERY LONG BASELINE ARRAY GALACTIC PLANE SURVEY-VGaPS

This paper presents accurate absolute positions from a 24 GHz Very Long Baseline Array (VLBA) search for compact extragalactic sources in an area where the density of known calibrators with precise coordinates is low. The goals were to identify additional sources suitable for use as phase calibrators for galactic sources, determine their precise positions, and produce radio images. In order to achieve these goals, we developed a new software package, PIMA, for determining group delays from wide-band data with much lower detection limits. With the use of PIMA, we have detected 327 sources out of 487 targets observed in three 24 hr VLBA experiments. Among the 327 detected objects, 176 are within 10 deg. of the Galactic plane. This VGaPS catalog of source positions, plots of correlated flux density versus projected baseline length, contour plots, as well as weighted CLEAN images, and calibrated visibility data are available on the Web in FITS format. Approximately one-half of objects from the 24 GHz catalog were observed at dual-band 8.6 GHz and 2.3 GHz experiments. Position differences at 24 GHz versus 8.6/2.3 GHz for all but two objects on average are strictly within reported uncertainties. We found that for two objects with complex structures, positions at different frequencies correspond to different components of a source.

79 ASTRONOMY AND ASTROPHYSICS↗

Measurements of Oxychlorine species on Mars

Mars landed and orbiter missions have instrumentation capable of detecting oxychlorine phases (e.g. perchlorate, chlorate) on the surface. Perchlorate (~0.6 wt%) was first detected by the Wet Chemistry Laboratory in the surface material at the Phoenix Mars Landing site. Subsequent analyses by the Thermal Evolved Gas Analyser aboard the same lander detected an oxygen release (~465°C) consistent with the thermal decomposition of perchlorate. Recent thermal analysis by the Mars Science Laboratory’s Sample Analysis at Mars instrument has also indicated the presence of oxychlorine phases (up to 1.2 wt%) in Gale Crater materials. Despite being at detectable concentrations, the Chemistry and Mineralogy (CheMin) X-ray diffractometer has not detected oxychlorine phases. This suggests that Gale Crater oxychlorine may exist as poorly crystalline phases or that perchlorate/chlorate mixtures exist, so that individual oxychlorine concentrations are below CheMin detection limits (~1 wt%). Although not initially designed to detect oxychlorine phases, reinterpretation of Viking Gas Chromatography/Mass Spectrometer data also suggest that oxychlorine phases are present in the Viking surface materials. Remote near-infrared spectral analyses by the Compact Reconnaissance Imaging Spectrometer for Mars (CRISM) instrument indicate that at least some martian recurring slope lineae (RSL) have spectral signatures consistent with the presence of hydrated perchlorates or chlorates during the seasons when RSL are most extensive. Despite the thermal emission spectrometer, Thermal Emission Imaging System, Observatoire pour la Minéralogie, l’Eau, les Glaces et l’Activité and CRISM detection of hundreds of anhydrous chloride (~10–25 vol%) deposits, expected associated oxychlorine phases (>5–10 vol%) have not been detected. Total Cl and oxychlorine data sets from the Phoenix Lander and the Mars Science Laboratory missions could be used to develop oxychlorine versus total Cl correlations, which may constrain oxychlorine concentrations at other locations on Mars by using total Cl determined by other missions (e.g. Viking, Pathfinder, MER and Odyssey). Development of microfluidic or ‘lab-on-a-chip’ instrumentation has the potential to be the next generation analytical capability used to identify and quantify individual oxychlorine species on future landed robotic missions to Mars.

Perchlorate↗

Simultaneous Planck , Swift , and Fermi observations of X-ray and γ -ray selected blazars

We present simultaneous Planck, Swift, Fermi, and ground-based data for 105 blazars belonging to three samples with flux limits in the soft X-ray, hard X-ray, and γ-ray bands, with additional 5GHz flux-density limits to ensure a good probability of a Planck detection. We compare our results to those of a companion paper presenting simultaneous Planck and multi-frequency observations of 104 radio-loud northern active galactic nuclei selected at radio frequencies. While we confirm several previous results, our unique data set allows us to demonstrate that the selection method strongly influences the results, producing biases that cannot be ignored. Almost all the BL Lac objects have been detected by the Fermi Large AreaTelescope (LAT), whereas 30% to 40% of the flat-spectrum radio quasars (FSRQs) in the radio, soft X-ray, and hard X-ray selected samples are still below the γ-ray detection limit even after integrating 27 months of Fermi-LAT data. The radio to sub-millimetre spectral slope of blazars is quite flat, with >α> ~ 0 up to about 70GHz, above which it steepens to <α> ~ -0.65. The BL Lacs have significantly flatter spectra than FSRQs at higher frequencies. The distribution of the rest-frame synchrotron peak frequency (ν peak S ) in the spectral energy distribution (SED) of FSRQs is the same in all the blazar samples with <ν peak S > = 10 13.1 ± 0.1 Hz, while the mean inverse Compton peak frequency, >ν peak IC >, ranges from 1021 to 1022 Hz. The distributions of ν peak S and ν peak IC of BL Lacs are much broader and are shifted to higher energies than those of FSRQs; their shapes strongly depend on the selection method. The Compton dominance of blazars, defined as the ratio of the inverse Compton to synchrotron peak luminosities, ranges from less than 0.2 to nearly 100, with only FSRQs reaching values larger than about 3. Its distribution is broad and depends strongly on the selection method, with γ-ray selected blazars peaking at ~7 or more, and radio-selected blazars at values close to 1, thus implying that the common assumption that the blazar power budget is largely dominated by high-energy emission is a selection effect. A comparison of our multi-frequency data with theoretical predictions shows that simple homogeneous SSC models cannot explain the simultaneous SEDs of most of the γ-ray detected blazars in all samples. The SED of the blazars that were not detected by Fermi-LAT may instead be consistent with SSC emission. Our data challenge the correlation between bolometric luminosity and ν peak S predicted by the blazar sequence.

79 ASTRONOMY AND ASTROPHYSICS↗

Simultaneous Planck, Swift, and Fermi Observations of X-ray and Gamma-ray Selected Blazars

We present simultaneous Planck, Swift, Fermi, and ground-based data for 105 blazars belonging to three samples with flux limits in the soft X-ray, hard X-ray, and gamma-ray bands, with additional 5 GHz flux-density limits to ensure a good probability of a Planck detection. We compare our results to those of a companion paper presenting simultaneous Planck and multi-frequency observations of 104 radio-loud northern active galactic nuclei selected at radio frequencies. While we confirm several previous results, our unique data set allows us to demonstrate that the selection method strongly influences the results, producing biases that cannot be ignored. Almost all the BL Lac objects have been detected by the Fermi Large Area Telescope (LAT), whereas 30% to 40% of the flat-spectrum radio quasars (FSRQs) in the radio, soft X-ray, and hard X-ray selected samples are still below the gamma-ray detection limit even after integrating 27 months of Fermi-LAT data. The radio to sub-millimetre spectral slope of blazars is quite flat, with (alpha) approx 0 up to about 70GHz, above which it steepens to (alpha) approx -0.65. The BL Lacs have significantly flatter spectra than FSRQs at higher frequencies. The distribution of the rest-frame synchrotron peak frequency (nu(sup s)(sub peak)) in the spectral energy distribution (SED) of FSRQs is the same in all the blazar samples with (nu(sup s)(sub peak)) = 10(exp 13.1 +/- 0.1) Hz, while the mean inverse Compton peak frequency, (nu(sup IC)(sub peak)), ranges from 10(exp 21) to 10(exp 22) Hz. The distributions of nu(sup s)(sub peak) and nu(sup IC)(sub peak) of BL Lacs are much broader and are shifted to higher energies than those of FSRQs; their shapes strongly depend on the selection method. The Compton dominance of blazars. defined as the ratio of the inverse Compton to synchrotron peak luminosities, ranges from less than 0.2 to nearly 100, with only FSRQs reaching values larger than about 3. Its distribution is broad and depends strongly on the selection method, with gamma-ray selected blazars peaking at approx 7 or more, and radio-selected blazars at values close to 1, thus implying that the common assumption that the blazar power budget is largely dominated by high-energy emission is a selection effect. A comparison of our multi-frequency data with theoretical predictions shows that simple homogeneous SSC models cannot explain the simultaneous SEDs of most of the gamma-ray detected blazars in all samples. The SED of the blazars that were not detected by Fermi~LAT may instead be consistent with SSC emission. Our data challenge the correlation between bolometric luminosity and nu(sup s)(sub peak) predicted by the blazar sequence.

Giommi, P.↗

Analysis of Defense Waste Processing Facility (DWPF) Condensate Samples and Evaluation of the Glycolate Destruction Process during Nitric-Glycolic flowsheet Transition

Glycolate concentrations were measured by the Savannah River National Laboratory (SRNL) in Slurry Mix Evaporator Condensate Tank (SMECT) and Recycle Collection Tank (RCT) samples retrieved after implementation of the Nitric-Glycolic Acid flowsheet at the Defense Waste Processing Facility (DWPF). No glycolate has been detected in any sample using Ion Chromatography (IC) with a detection limit of 8 mg/L, and no glycolate has been detected using either IC or Proton Nuclear Magnetic Resonance Spectroscopy ( 1 HNMR) after a permanganate strike was performed in the RCT.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Single Channel Infrasound Detection Using Machine Learning

Infrasound, low frequency sound less than 20 Hz, is generated by both natural and anthropogenic sources. Infrasound sensors measure pressure fluctuations only in the vertical plane and are single channel. However, the most robust infrasound signal detection methods rely on stations with multiple sensors (arrays), despite the fact that these are sparse. Automated methods developed for seismic data, such as short-term average to long-term average ratio (STA/LTA), often have a high false alarm rate when applied to infrasound data. Leveraging single channel infrasound stations has the potential to decrease signal detection limits, though this cannot be done without a reliable detection method. Therefore, this report presents initial results using (1) a convolutional neural network (CNN) to detect infrasound signals and (2) unsupervised learning to gain insight into source type.

47 OTHER INSTRUMENTATION↗