Search NASA⌕ Search

SEARCH · Search NASA

Results for “Detection.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Real-time standoff detection of nitrogen isotopes in ammonia plumes using a swept external cavity quantum cascade laser

A swept-wavelength external cavity quantum cascade laser is used to measure time-resolved 15NH3 and 14NH3 concentrations and isotope ratios in a turbulent plume source located at 10 m standoff distance. Measurements show excellent agreement with expected values of isotope ratios for samples with natural and enriched 15N abundance. Detection sensitivity of 150 ppb*m is demonstrated for a 50 ms measurement interval, improving to 10 ppb*m with 10 s averaging, with isotopic precision as good as 0.8%.

Phillips, Mark C.↗

Detectability of Varied Hybridization Scenarios Using Genome-Scale Hybrid Detection Methods

Hybridization events complicate the accurate reconstruction of phylogenies, as they lead to patterns of genetic heritability that are unexpected under traditional, bifurcating models of species trees. This phenomenon has led to the development of methods to infer these varied hybridization events, both methods that reconstruct networks directly, as well as summary methods that predict individual hybridization events from a subset of taxa. However, a lack of empirical comparisons between methods – especially those pertaining to large networks with varied hybridization scenarios – hinders their practical use. Here, we provide a comprehensive review of popular summary methods: TICR, MSCquartets, HyDe, Patterson’s D-Statistic (ABBA-BABA), D3, and Dp. TICR and MSCquartets are based on quartet concordance factors gathered from gene tree topologies and HyDe, Patterson’s D-Statistic, D3, and Dp use site pattern frequencies to identify hybridization events between sets of three taxa. We then use simulated data to address questions of method accuracy and ideal use scenarios by testing methods against complex networks which depict gene flow events that differ in depth (timing), quantity (single vs. multiple, overlapping hybridizations), and rate of gene flow (γ). We find that deeper or multiple hybridization events may introduce noise and weaken the signal of hybridization, leading to higher relative false negative rates across all methods. Despite some forms of hybridization eluding quartet-based detection methods, MSCquartets displays high precision in most scenarios. While HyDe results in high false negative rates when tested on hybridizations involving extinct or unsampled ghost lineages, HyDe is the only method able to identify the direction of hybridization, distinguishing the source parental lineages from recipient hybrid lineages. Lastly, we test the methods on a dataset of ultraconserved elements from the bee subfamily Nomiinae, finding possible hybridization events between clades which correspond to regions of poor support in the species tree estimated in a previous study.

Bjorner, Marianne B.↗

Low Energy LArTPC Signal Detection Using Anomaly Detection

Extracting low-energy signals from LArTPC detectors is useful, for example, for detecting supernova events or calibrating the energy scale with argon-39. However, it is difficult to efficiently extract the signals because of noise. We propose using a 1DCNN to select wire traces that have a signal. This efficiently suppresses the background while still being efficient for the signal. This is then followed by a 1D autoencoder to denoise the wire traces. At that point the signal waveform can be cleanly extracted. In order to make this processing efficient, we implement the two networks on an FPGA. In particular we use hls4ml to produce HLS from the Keras models for both the 1DCNN and the autoencoder. We deploy them on an AMD/Xilinx Alveo U55C using the Vitis software platform.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Near optimum delay-line detection filters for serial detection of MSK signals

A method for designing transversal delay-line filter approximations to the matched filter for the serial detection of minimum-shift keyed (MSK) modulated signals is given. Two configurations are characterized in terms of signal-to-noise ratio degradation at a bit error rate (BER) of 10 to the -6th. One is shown to depart less than 0.3 dB from the ideal matched filter performance when its parameter values are optimized. A lumped-element equivalent is also given and shown to provide a degradation of less than 0.4 dB at a BER of 10 to the -6th

Ziemer, R. E.↗

A Feasibility Study for Perioperative Ventricular Tachycardia Prognosis and Detection and Noise Detection Using a Neural Network and Predictive Linear Operators

To locate the accessory pathway(s) in preexicitation syndromes, epicardial and endocardial ventricular mapping is performed during anterograde ventricular activation via accessory pathway(s) from data originally received in signal form. As the number of channels increases, it is pertinent that more automated detection of coherent/incoherent signals is achieved as well as the prediction and prognosis of ventricular tachywardia (VT). Today's computers and computer program algorithms are not good in simple perceptual tasks such as recognizing a pattern or identifying a sound. This discrepancy, among other things, has been a major motivating factor in developing brain-based, massively parallel computing architectures. Neural net paradigms have proven to be effective at pattern recognition tasks. In signal processing, the picking of coherent/incoherent signals represents a pattern recognition task for computer systems. The picking of signals representing the onset ot VT also represents such a computer task. We attacked this problem by defining four signal attributes for each potential first maximal arrival peak and one signal attribute over the entire signal as input to a back propagation neural network. One attribute was the predicted amplitude value after the maximum amplitude over a data window. Then, by using a set of known (user selected) coherent/incoherent signals, and signals representing the onset of VT, we trained the back propagation network to recognize coherent/incoherent signals, and signals indicating the onset of VT. Since our output scheme involves a true or false decision, and since the output unit computes values between 0 and 1, we used a Fuzzy Arithmetic approach to classify data as coherent/incoherent signals. Furthermore, a Mean-Square Error Analysis was used to determine system stability. The neural net based picking coherent/incoherent signal system achieved high accuracy on picking coherent/incoherent signals on different patients. The system also achieved a high accuracy of picking signals which represent the onset of VT, that is, VT immediately followed these signals. A special binary representation of the input and output data allowed the neural network to train very rapidly as compared to another standard decimal or normalized representations of the data.

Moebes, T. A.↗

Device for detecting molecules, method for detecting molecules

A construct is provided that is capable of binding a plurality of molecules, the construct comprising a first moiety with a first molecule binding region and a first molecule non-binding region; and a second moiety with a second molecule-binding region and a second molecule-non-binding region, whereby the first binding region and second binding region are at opposite ends of the construct. Also provided is a method for detecting protein having certain amino acid sequences, the method comprising supplying a collection of proteins each with unknown amino acid sequences, contacting the collection with a moiety having a plurality of binding sites capable of binding with the protein having certain amino acid sequences so as to form a moiety-protein complex, and mixing the complex with a marker specific for the moiety in an amount sufficient to indicate existence of the complex.

59 BASIC BIOLOGICAL SCIENCES↗

Fast Proton Hopping Detection in Ice Ih by Quasi-Elastic Neutron Scattering

Quasi-elastic neutron scattering was employed on samples of HCl-doped polycrystalline ice I{sub h}. The analysis of the scattering signal provides the excess proton hopping time, {tau}{sub hop}, in the temperature range of 140-195 K. The hopping time strongly depends on the temperature of the sample, and the activation energy of a hopping step is 17 kJ/mol. The values of {tau}{sub hop} of the current experiment are in good agreement with calculated values derived from previous photochemical experiments,(1) in which we found that the proton hopping time at T > 242 K is on the order of 200 fs, roughly 10 times shorter than in liquid water at room temperature.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Lanthanum halide nanoparticle scintillators for nuclear radiation detection

Nanoparticles with sizes <10 nm were fabricated and characterized for their nanocomposite radiation detector properties. This work investigated the properties of several nanostructured radiation scintillators, in order to determine the viability of using scintillators employing nanostructured lanthanum trifluoride. Preliminary results of this investigation are consistent with the idea that these materials have an intrinsic response to nuclear radiation that may be correlated to the energy of the incident radiation.

36 MATERIALS SCIENCE↗

Light mediators in dark matter direct detections

In an extended effective operator framework, we investigate in detail the effects of light mediators on the event spectra of dark matter (DM)-nucleus scatterings. The presence of light mediators changes the interpretation of the current experimental data, especially the determination of DM particle mass. We show by analytic and numerical illustrations that in general for all the operators relevant to spin-independent scatterings, the DM particle mass allowed by a given set of experimental data increases significantly when the mediator particle becomes lighter. For instance, in the case of CDMS-II-Si experiment, the allowed DM particle mass can reach ∼50 (100) GeV at 68% (90%) confidence level, which is much larger than ∼10 GeV in the case with contact interactions. The increase of DM particle mass saturates when the mediator mass is below O(10) MeV. The upper limits from other experiments such as SuperCDMS, CDMSlite, CDEX, XENON10/100, LUX, PandaX etc. all tend to be weaker toward high DM mass regions. In a combined analysis, we show that the presence of light mediators can partially relax the tension in the current results of CDMS-II-Si, SuperCDMS and LUX.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of Diamond-Based X-ray Detection for High Flux Beamline Diagnostics

High-quality single-crystal and polycrystalline chemical-vapor-deposition diamond detectors with platinum contacts have been tested at the white-beam X28C beamline at the National Synchrotron Light Source under high-flux conditions. The voltage dependence of these devices has been measured under both DC and pulsed-bias conditions, establishing the presence or absence of photoconductive gain in each device. Linear response consistent with the theoretically determined ionization energy has been achieved over eleven orders of magnitude when combined with previous low-flux studies. Temporal measurements with single-crystal diamond detectors have resolved the nanosecond-scale pulse structures of both the NSLS and the APS. Prototype single-crystal quadrant detectors have provided the ability to simultaneously resolve the X-ray beam position and obtain a quantitative measurement of the flux.

36 MATERIALS SCIENCE↗

A Freon-Filled Bubble Chamber for Neutron Detection in Inertial Confinement Fusion Experiments

Neutron imaging is one of the main methods used in inertial confinement fusion experiments to measure the core symmetry of target implosions. Previous studies have shown that bubble chambers have the potential to obtain higher resolution images of the targets for a shorter source-to-target distance than typical scintillator arrays. A bubble chamber for neutron imaging with Freon 115 as the active medium was designed and built for the OMEGA laser system. Bubbles resulting from spontaneous nucleation were recorded. Bubbles resulting from neutron–Freon interactions were observed at neutron yields of 1013 emitted from deuterium–tritium target implosions on OMEGA. The measured column bubble density was too low for neutron imaging on OMEGA but agreed with the model of bubble formation. The recorded data suggest that neutron bubble detectors are a promising technology for the higher neutron yields expected at National Ignition Facility.

Ghilea, M C↗