Search NASA⌕ Search

SEARCH · Search NASA

Results for “Detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Simulations of Sparse Static Detector Networks for City-Scale Radiological/Nuclear Detection

Sparse static detector networks in urban environments can be used in efforts to detect illicit radioactive sources, such as stolen nuclear material or radioactive "dirty bombs." We use detailed simulations to evaluate multiple configurations of detector networks and their ability to detect sources moving through a $6\times 6$ km 2 area of downtown Chicago. A detector network's probability of detecting a source increases with detector density but can also be increased with strategic node placement. Here, we show that the ability to fuse correlated data from a source-carrying vehicle passing by multiple detectors can significantly contribute to the overall detection probability. In this article, we distinguish static sensor deployments operated as networks able to correlate signals between sensors, from deployments operated as arrays where each sensor is operated individually. In particular, we show that additional visual attributes of source-carrying vehicles, such as vehicle color and make, can greatly improve the ability of a detector network to detect illicit sources.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Direct current response of a thin scCVD diamond detector under increased applied field to 14.1 MeV neutrons

An avalanche effect yielding inherent gain can be exploited in thin, single-crystal chemical vapor deposition (scCVD) diamond. It occurs when a high enough bias is applied across the diamond thickness while avoiding breakdown. This charge multiplication effect was studied previously with alpha particles and heavy ions either by using the transient current technique or by measuring the energy spectrum. The measurements we obtained to evaluate the charge multiplication performance of a 10 μm thick scCVD diamond detector used a novel approach—we employed an electrometer to characterize the response of the detector by performing directly coupled current measurements (time-averaged charge, at 1 Hz sampling) when exposed to 14.1 MeV neutrons from deuterium-tritium fusion. We measured both the dark and irradiated currents from the detector over a range of applied displacement field values from 2 to 75 V/μm. A histogram method with central mean and standard deviation width was used to determine the current over each measurement duration typically from 100 to 300 seconds. The dark-subtracted irradiated current (i.e., contrast) was used to evaluate the gain of the detector at each applied displacement field. The contrast at an applied displacement field between 15 and 20 V/μm was higher than the expected linear increase in contrast proportional to the increased applied bias, indicating the possible presence of avalanche events in the diamond. The detector response also indicated possible polarization and charge depletion effects. These results provide an opportunity to further explore the use of thin scCVD diamond as a fast neutron current mode detector with inherent gain.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Alignment of the ATLAS Inner Detector in Run 2

The performance of the ATLAS Inner Detector alignment has been studied using pp collision data at s√=13TeV collected by the ATLAS experiment during Run 2 (2015–2018) of the Large Hadron Collider (LHC). The goal of the detector alignment is to determine the detector geometry as accurately as possible and correct for time-dependent movements. The Inner Detector alignment is based on the minimization of track-hit residuals in a sequence of hierarchical levels, from global mechanical assembly structures to local sensors. Subsequent levels have increasing numbers of degrees of freedom; in total there are almost 750,000. The alignment determines detector geometry on both short and long timescales, where short timescales describe movements within an LHC fill. The performance and possible track parameter biases originating from systematic detector deformations are evaluated. Momentum biases are studied using resonances decaying to muons or to electrons. The residual sagitta bias and momentum scale bias after alignment are reduced to less than ~0.1 TeV -1 and 0.9×10 -3 , respectively. Impact parameter biases are also evaluated using tracks within jets.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The NEXT-100 Detector

The NEXT collaboration is dedicated to the study of double beta decays of 136 Xe using a high-pressure gas electroluminescent time projection chamber. This advanced technology combines exceptional energy resolution (≤ 1% FWHM at the Q ββ value of the neutrinoless double beta decay) and powerful topological event discrimination. Building on the achievements of the NEXT-White detector, the NEXT-100 detector started taking data at the Laboratorio Subterráneo de Canfranc (LSC) in May of 2024. Designed to operate with xenon gas at 13.5 bar, NEXT-100 consists of a time projection chamber where the energy and the spatial pattern of the ionising particles in the detector are precisely retrieved using two sensor planes (one with photo-multiplier tubes and the other with silicon photo-multipliers). The detector has been operating at stable conditions using argon and xenon gases at ~4 bar and drift fields of 74 V cm –1 and 118 V cm –1 , respectively. Alpha decays from the 222 Rn chain have been used to test and monitor the stability of the detector, showing a constant electron lifetime in the drift volume. In this paper, in addition to reporting the results of the commissioning run, we provide a detailed description of the NEXT-100 detector, describe its assembly, and present the current estimation of the radiopurity budget.

Adams, C. [Argonne National Laboratory; NVIDIA] (O↗

Reduction in radioactivity-induced backgrounds using a novel active veto detector for rare event search experiments

The results of a newly developed annular cryogenic phonon-mediated active veto detector are discussed which shows a significant reduction of radioactivity-induced backgrounds in rare event search experiments. The veto detector is made up of germanium weighing ∼500 g with an outer diameter of 76 mm and an inner diameter of 28 mm. The detector can host a 25 mm diameter germanium inner target detector of mass ∼10 g. A GEANT4 simulation with the active veto and inner target detector shows a gamma background reduction of 50 - 80% which is further improved (> 90%) with 4pi veto coverage. Experimental measurements with the detector assembly agree well with the simulation.

Chaudhuri, Mouli↗

Radiation hard Ga 2 O 3 detectors for high energy physics

In this project, we explore the use of ultra-wide bandgap Ga 2 O 3 materials for fabricating next-generation radiation hard solid-state detectors for high energy physics (HEP) applications. As an emerging semiconductor, Ga 2 O 3 has ultra-wide bandgap (4.5-4.9 eV), high breakdown electric field (8 MV/cm) and much lower production cost compared with radiation hard diamond detectors, all of which make Ga 2 O 3 a great candidate material working in harsh radiation environment of future HEP experiments. The recent breakthrough of growth technologies of Ga 2 O 3 significantly improves the availability of large area single crystalline Ga 2 O 3 . We focus on an early proof-of-principle demonstration of Ga 2 O 3 detectors and conduct comprehensive material and detector characterization to evaluate the potential of the emerging Ga 2 O 3 as a new radiation-hard detector material. Our endeavors directly support the instrumentation development and update need of HEP experiments and fits very well into the DOE HEP “Detector R&D” research subprogram.

36 MATERIALS SCIENCE↗

3D-Reconstruction of Tau Neutrinos in LArTPC Detectors

The Deep Underground Neutrino Experiment (DUNE) is a next-generation neutrino experiment currently under construction. DUNE will consist of two high-resolution neutrino interaction imaging detectors exposed to the world’s most intense neutrino beam, with the Near Detector at Fermilab and the Far Detector 1,300 km away in the Sanford Underground Research Facility in South Dakota, US. The high statistics and excellent resolution capabilities of DUNE's $^{40}$Ar detector will allow us to make precision studies of oscillation parameters capable of searching for CP violation in the lepton sector, testing interaction models, and studying phenomena that have until now, seemed too complex to measure, like $\nu_\tau$ detection and therefore, providing the completion of the 3-flavor neutrino paradigm. Knowledge of the $\nu_\tau$ detection can impact a broad spectrum of open questions. These include searching for non-standard neutrino interactions, constraining the unitarity of the PMNS matrix, searching for sterile neutrinos, and studying neutrino interactions. In the case of LArTPC data, the detector hits can be considered nodes in a graph, and the edges represent the spatial and temporal relationships between them. By using graph neural networks, it is possible to exploit these relationships and improve the accuracy of particle identification and reconstruction. During my presentation and specifically for tau neutrino reconstruction, I will show the effectiveness and reliability of our in-house developed graph neural network (GNN), NuGraph. This GNN classifies detector hits based on the particle type responsible for their production, assuring that the system accurately identifies and categorizes information based on its unique characteristics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Impact of Source Geometry on Detector Response Matrix Efficiency: Simulations of the PFUNS-MUSiC Experiments

This work looks at two different bare highly enriched uranium (HEU) systems, configuration one from Measurements of Uranium Subcritical and Critical (MUSiC) and Prompt Fission Uranium Neutron Spectrum (PFUNS) to see the effect geometry has on detector efficiency and the response matrix. The distance from the multiplying source, the medium between the source and detector, and the geometry of the source all play a part in the efficiency of the detector. These factors are especially important when performing spectrum unfolding. Spectrum unfolding is a process used to reconstruct a true spectrum from measured detector response data. It involves interpreting a set of measured values, such as a light signal from a scintillator, to recover the original neutron energy spectrum. This leads to the question, how much will the efficiency of a detector change when you measure a point source compared to an extended source? The distance and solid angle from the source to the detector may be different. It may only be a minuscule change, but in the spectrum unfolding process it can have a considerable effect on the unfolded spectrum

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Event Reconstruction for Water-based Liquid Scintillator Detectors

Water Cherenkov and liquid scintillator detectors represent two complementary approaches in neutrino physics. Water Cherenkov detectors provide particle track direction and particle identification (PID) through Cherenkov ring topology, while liquid scintillator detectors offer higher light yield and lower energy thresholds. Water-based liquid scintillator (WbLS) is designed to combine the advantages of both technologies. However, the simultaneous detection of Cherenkov and scintillation light by photosensors introduces significant challenges for event reconstruction. This poster presents event reconstruction studies for WbLS detectors. A likelihood-based reconstruction framework, fiTQun, has been successfully used in Super-Kamiokande to reconstruct water Cherenkov events in cylindrical detectors. We extend and improve this framework to demonstrate event reconstruction in WbLS detectors, enabling the concurrent reconstruction of particle energy, PID, vertex, and direction. The results demonstrate competitive performance in energy resolution, PID separation, and vertex and direction reconstruction, highlighting the strong potential of WbLS for next-generation neutrino experiments.

Xie, Zhenxiong [Minnesota U.] (ORCID:0009000301442↗

SBND Detector Status and First Results

The Short-Baseline Near Detector (SBND) is one of three liquid argon time projection chamber (LArTPC) neutrino detectors positioned along the axis of the Booster Neutrino Beam (BNB) at Fermilab, and serves as the near detector in the Short-Baseline Neutrino (SBN) Program. The detector just completed its second year of running, collecting over 6.5e20 POT, equivalent to an unprecedented sample of over 5 million neutrino interactions. Initial data has demonstrated superb performance of the detector’s subsystems, enabling precise tracking and calorimetric reconstruction of events. With this large statistical data set, SBND is performing multi-dimensional cross section measurements of inclusive and exclusive topologies and precise searches for beyond the Standard Model (BSM) processes. As the near detector in the SBN Program, it will enable the full potential of the joint sterile neutrino measurements program by precisely characterizing the unoscillated neutrino beam, constraining BNB flux and neutrino-argon cross-section systematic uncertainties. In this talk, the current status of the experiment, first results from SBND’s neutrino interaction program, as well as status and prospects for BSM and oscillation searches are discussed.

Paton, Josephine [Fermilab] (ORCID:000000032651489↗

The response of a 300 micron silicon detector to monoenergetic neutrons determined by the use of the Monte Carlo technique

The response of a 300 micron thick silicon detector to an incident monoenergetic neutron beam is evaluated by the Monte Carlo method for the cases of both a shielded and a bare detector. The result of Monte Carlo calculation, using elastic, inelastic, and absorption reactions indicates that the response of the silicon detector to neutrons is basically due to the elastic scattering. In addition, the gamma rays generated in the shield of the detector will result in a response which is 3 or 4 orders of magnitude smaller than response to incident photons. The response of a bare silicon detector is calculated for neutron energies up to 6 MeV and bias energies from 50 to 250 KeV. It is found that the maximum response for a 300 micron thick silicon detector is less than .004 c/n within this selected neutron and bias energy range. When the pulse height defect is introduced in the calculation the results at low energy neutrons were reduced.

Tahezadeh, M.↗

High speed, high performance /Hg,Cd/Te photodiode detectors.

The current performance of high speed photodiode detectors for the 1 to 10 micron spectral region is discussed. The (Hg,Cd)Te photodiode configuration, detector properties, integration in laser receiver modules, and frequency response are considered for near infrared and far infrared wavelengths. The recent advances in (Hg,Cd)Te material and device development are indicated by the realization not only of exceptionally high speed detectors but of detectors that exhibit excellent detectivities. The performance improves substantially when the detector is cooled. This detector junction technology has been extended to other compositions of (Hg,Cd)Te for peak spectral responses at 5 and 10 micron.

Soderman, D. A.↗

Detector absorptivity measuring method and apparatus

A method and apparatus for measuring the absorptivity of a radiation detector by making the detector an integral part of a cavity radiometer are described. By substituting the detector for the surface of the cavity upon which the radiation first impinges a comparison is made between the quantity of radiation incident upon the detector and the quantity reflected from the detector. The difference between the two is a measurement of the amount of radiation absorbed by the detector.

Sheets, R. E.↗

The development of an electrochemical technique for in situ calibrating of combustible gas detectors

A program to determine the feasibility of performing in situ calibration of combustible gas detectors was successfully completed. Several possible techniques for performing the in situ calibration were proposed. The approach that showed the most promise involved the use of a miniature water vapor electrolysis cell for the generation of hydrogen within the flame arrestor of a combustible gas detector to be used for the purpose of calibrating the combustible gas detectors. A preliminary breadboard of the in situ calibration hardware was designed, fabricated and assembled. The breadboard equipment consisted of a commercially available combustible gas detector, modified to incorporate a water vapor electrolysis cell, and the instrumentation required for controlling the water vapor electrolysis and controlling and calibrating the combustible gas detector. The results showed that operation of the water vapor electrolysis at a given current density for a specific time period resulted in the attainment of a hydrogen concentration plateau within the flame arrestor of the combustible gas detector.

Shumar, J. W.↗

Radiation damage of germanium detectors

Energetic particles can produce interstitial-vacancy pairs in a crystal by knocking the atoms from their normal positions. Detectors are unique among semiconductor devices in depending on very low concentrations of electrically active impurities, and also on efficient transport of holes and electrons over relatively large distances. Because the dense regions of damage produced by energetic particles may result in donors and/or acceptors, and also provide trapping sites for holes and electrons, detectors are very sensitive to radiation damage. In addition to these effects occurring within the detector, radiation may also change the characteristics of the exposed surfaces causing unpredictable effects on the detector leakage current. Radiation-induced surface degradation has rarely, if ever, been observed for germanium detectors. The possibility of minimizing hole trapping in charge collection by the use of a high-purity germanium coaxial detector configured with the p (+) contact on the coaxial periphery is discussed.

Pehl, R. H.↗

Ge:Ga and Ge:Be photoconductive detectors for far infrared astronomy from a space platform

The paper describes some of the development work on gallium-doped germanium (Ge:Ga) and beryllium-doped germanium (Ge:Be) photoconductive detectors for use in far-infrared astronomical observations from a space platform such as IRAS. The paper is concerned primarily with detector performance and is divided into two major parts. The first presents the operating principles of this type of detector, while the second presents measured performance data under low-background flux conditions. It is shown that high sensitivity can be obtained from Ge:Ga and Ge:Be detectors under low-background and low-temperature conditions of operation. These detectors are useful for astronomical observations in the far-infrared over the wavelength range 30-120 microns. Major conclusions of the research work done so far are mentioned, including that detectors cut from the same crystal show reasonably good reproducibility of operating characteristics.

Bratt, P. R.↗

A rocket-borne energy spectrometer using multiple solid-state detectors for particle identification

A rocket-borne experiment using energy spectrometers that allows particle identification by the use of multiple solid-state detectors is described. The instrumentation provides information regarding the energy spectrum, pitch-angle distribution, and the type of energetic particles present in the ionosphere. Particle identification was accomplished by considering detector loss mechanisms and their effects on various types of particles. Solid state detectors with gold and aluminum surfaces of several thicknesses were used. The ratios of measured energies for the various detectors were compared against known relationships during ground-based analysis. Pitch-angle information was obtained by using detectors with small geometrical factors mounted with several look angles. Particle flux was recorded as a function of rocket azimuth angle. By considering the rocket azimuth, the rocket precession, and the location of the detectors on the rocket, the pitched angle of the incident particles was derived.

Fries, K. L.↗

Performance of room temperature mercuric iodide /HgI2/ detectors in the ultralow-energy X-ray region

Experiments have been done to study the performance of mercuric iodide (HgI2) detectors in the ultralow-energy X-ray region. Energy resolution values of 245 eV (FWHM) for the Mg K-alpha X-ray line at 1.25 keV and 225 eV (FWHM) for the electronic noise linewidth have been obtained for an HgI2 detector with painted carbon contacts using a pulsed-light feedback preamplifier; the whole system was operated at room temperature. The resolution values in the ultralow-energy region are still limited by electronic noise of the system. In an attempt to minimize X-ray attenuation in the front contact, detectors were prepared with thin evaporated Pd contacts. These detectors show a pronounced low-energy tailing of the photopeak below a few keV, in contrast to the spectra obtained by detectors with carbon contact. An attempt has been made to explain the tailing effect starting with models wich have been proposed to describe similar effects in Ge detectors.

Dabrowski, A. J.↗