Search NASA⌕ Search

SEARCH · Search NASA

Results for “Diffractive”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

In situ X-Ray Diffraction of Shock-Compressed Fused Silica

Because of its widespread applications in materials science and geophysics, SiO 2 has been extensively examined under shock compression. Both quartz and fused silica transform through a so-called “mixed-phase region” to a dense, low compressibility high-pressure phase. For decades, the nature of this phase has been a subject of debate. Proposed structures include crystalline stishovite, another high-pressure crystalline phase, or a dense amorphous phase. Here we use plate-impact experiments and pulsed synchrotron x-ray diffraction to examine the structure of fused silica shock compressed to 63 GPa. In contrast to recent laser-driven compression experiments, we find that fused silica adopts a dense amorphous structure at 34 GPa and below. When compressed above 34 GPa, fused silica transforms to untextured polycrystalline stishovite. Our results can explain previously ambiguous features of the shock-compression behavior of fused silica and are consistent with recent molecular dynamics simulations. Stishovite grain sizes are estimated to be ~5–30 nm for compression over a few hundred nanosecond time scale.

58 GEOSCIENCES↗

Twinning and Dislocation Evolution during Shock Compression and Release of Single Crystals: Real-Time X-Ray Diffraction

Determining the temporal evolution of twinning and/or dislocation slip, in real time (nanoseconds), in single crystals subjected to plane shock wave loading is a long-standing scientific need. Non-cubic crystals pose special challenges because they have many competing slip and twinning systems. Here, we report on time-resolved, in situ, synchrotron Laue x-ray diffraction measurements during shock compression and release of magnesium single crystals that are subjected to compression along the c-axis. Significant twinning was observed directly during stress release following shock compression; during compression, only dislocation slip was observed. Our measurements unambiguously distinguish between twinning and dislocation slip on nanosecond timescales in a shocked hexagonal-close-packed metal.

36 MATERIALS SCIENCE↗

On the estimation of statistical uncertainties on powder diffraction and small-angle scattering data from two-dimensional X-ray detectors

Optimal methods are explored for obtaining one-dimensional powder pattern intensities from two-dimensional planar detectors with good estimates of their standard deviations. Methods are described to estimate uncertainties when the same image is measured in multiple frames as well as from a single frame. The importance of considering the correlation of diffraction points during the integration and the resampling process of data analysis is shown. It is found that correlations between adjacent pixels in the image can lead to seriously overestimated uncertainties if such correlations are neglected in the integration process. Off-diagonal entries in the variance–covariance (VC) matrix are problematic as virtually all data processing and modeling programs cannot handle the full VC matrix. It is shown that the off-diagonal terms come mainly from the pixel-splitting algorithm used as the default integration algorithm in many popular two-dimensional integration programs, as well as from rebinning and resampling steps later in the processing. When the full VC matrix can be propagated during the data reduction, it is possible to get accurate refined parameters and their uncertainties at the cost of increasing computational complexity. However, as this is not normally possible, the best approximate methods for data processing in order to estimate uncertainties on refined parameters with the greatest accuracy from just the diagonal variance terms in the VC matrix is explored.

Yang, X.↗

Point defects in Cu 2 ZnSnSe 4 (CZTSe): Resonant X-ray diffraction study of the low-temperature order/disorder transition: Point defects in Cu 2 ZnSnSe 4 (CZTSe)

The interest in Cu2ZnSn(S,Se)4 (CZTS) for photovoltaic applications is motivated by similarities to Cu(In,Ga)Se2 while being comprised of non-toxic and earth abundant elements. However, CZTS suffers from a Voc deficit, where the Voc is much lower than expected based on the band gap, which may be the result of a high concentration of point-defects in the CZTS lattice. Recently, reports have observed a low-temperature order/disorder transition by Raman and optical spectroscopies in CZTS films and is reported to describe the ordering of Cu and Zn atoms in the CZTS crystal structure. To directly determine the level of Cu/Zn ordering, we have used resonant-XRD, a site, and element specific probe of long range order. We used CZTSe films annealed just below and quenched from just above the transition temperature; based on previous work, the Cu and Zn should be ordered and highly disordered, respectively. Our data show that there is some Cu/Zn ordering near the low temperature transition but significantly less than high chemical order expected from Raman. To understand both our resonant-XRD results and the Raman results, we present a structural model that involves antiphase domain boundaries and accommodates the excess Zn within the CZTS lattice.

14 SOLAR ENERGY↗

In situ X-ray powder diffraction study of Ho{sub 5}Ge{sub 4}

In Ho{sub 5}Ge{sub 4} the magnetostructural transition (MST) from high temperature paramagnetic Sm{sub 5}Ge{sub 4}-type (O-II type) orthorhombic structure to a new low temperature antiferromagnetic (AFM) monoclinic structure (Mβ-structure; the distortion occurs in the ac-plane) results in discontinuities of 400, 400, and 300 ppm along a, b, and c axes, respectively. During MST the unit cell volume exhibits discontinuity of 1000 ppm, and changes in both inter and intra slab bonds are less than 2%. In the AFM state the application of 35 kOe magnetic field leads to a partial reconstruction of the high temperature O-II structure, which is accompanied with a large magnetostriction. The strain energy associated with magnetostriction effects leads to an incomplete field driven MST in the magnetically ordered state.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Measuring the diffraction properties of an imaging quartz(211) crystal

A dual goniometer X-ray system was used to measure the reflectivity curve for a spherically bent quartz(211) crystal. An analysis of the dual goniometer instrument response function for the rocking curve width measurement was developed and tested against the actual measurements. The rocking curve was measured at 4510.8 eV using the Ti Kα1 characteristic spectral line. The crystal is the dispersion element for a high resolution spectrometer used for plasma studies. It was expected to have a very narrow rocking curve width. The analysis showed that we could measure the upper bound for the rocking curve width of the Qz(211) crystal. The upper bound was 58 μrad giving a lower bound for the instrument resolving power E/ΔE = 34 000. Greatly improved insight into the dual goniometer operation and its limitations was achieved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Diffraction imaging for in situ characterization of double-crystal X-ray monochromators

Imaging of the Bragg-reflected X-ray beam is proposed and validated as an in situ method for characterization of the performance of double-crystal monochromators under the heat load of intense synchrotron radiation. A sequence of images is collected at different angular positions on the reflectivity curve of the second crystal and analyzed. The method provides rapid evaluation of the wavefront of the exit beam, which relates to local misorientation of the crystal planes along the beam footprint on the thermally distorted first crystal. The measured misorientation can be directly compared with the results of finite element analysis. The imaging method offers an additional insight into the local intrinsic crystal quality over the footprint of the incident X-ray beam.

cryogenic cooling↗

Communication: X-ray coherent diffractive imaging by immersion in nanodroplets

Lensless x-ray microscopy requires the recovery of the phase of the radiation scattered from a specimen. Here, we demonstrate a de novo phase retrieval technique by encapsulating an object in a superfluid helium nanodroplet, which provides both a physical support and an approximate scattering phase for the iterative image reconstruction. The technique is robust, fast-converging, and yields the complex density of the immersed object. As a result, images of xenon clusters embedded in superfluid helium droplets reveal transient configurations of quantum vortices in this fragile system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗