Search NASA⌕ Search

SEARCH · Search NASA

Results for “Distribution network”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Synchronization of Electric Power Networks

Invited contribution to the ITU News Magazine – Special Edition on “Future use and applications of the Coordinated Universal Time (UTC)” a joint ITU-BIPM initiative. The ITU will produce a special edition of its ITU News Magazine that will feature the “Future use and applications of the Coordinated Universal Time (UTC)”, a joint ITU-BIPM initiative, planned for publication in March or April, 2023. The main objective of the magazine is to educate telecommunication society about existing status of UTC applications, objectives, and possible ways to resolve the leap second issues. This article on “Synchronization of electrical distribution networks” for this edition, highlighting some of the key issues that will help the understanding of the important issues that are related to the coordinated universal time (UTC) and its dissemination.

Dagle, Jeffery E.↗

Electric Vehicle Charging Management in Smart Energy Communities to Increase Renewable Energy Hosting Capacity

Abnormal climates due to global warming have emerged as a big concern in the global community. To mitigate climate change and achieve sustainability, distributed energy resources (DERs), including solar and wind, have been recently deployed in power systems. As the penetration level of DERs has increased, however, it caused a multitude of issues in the power systems, such as voltage fluctuation in the distribution network limiting renewable hosting capacity. On the other hand, the electric vehicle (EV) industry is rapidly growing to facilitate the transition to a carbon-neutral community, illuminating the potential of EVs as a flexible grid asset to mitigate some of the issues and improve grid operation, if properly exploited. To explore the potential of EVs, this paper proposes an EV scheduling strategy. By using an optimal EV charging scheduling proposed, distribution system operators (DSOs) can minimize their operating costs and stably operate the system with a high level of DERs. To validate the method, a modified IEEE 33-bus system with DERs is developed. The case study shows the proposed scheduling strategizes EV charging to reduce the cost of PV curtailment. In the study, the method outperforms the renewable-only case with curtailment by 4.97% in DSO cost. It also demonstrates its potential to increase the renewable hosting capacity by harmonizing EV charging with renewables.

ADVANCED PROPULSION SYSTEMS,POWER TRANSMISSION AND↗

National Modeling of Geothermal District Energy Systems with Ambient-Temperature Loops Using dGeo: Preprint

Geothermal district energy systems (DES) with ambient-temperature loops, also known as thermal energy networks, are one option for decarbonizing space heating and cooling loads. Geothermal fifth-generation DES include an "ambient" temperature thermal loop that connects heat pumps at each building with thermal balancing sources such as geothermal borehole fields. Heating and cooling are provided via a water-source heat pump at each end-user. This project seeks to analyze the nationwide potential for ambient-temperature loop districts by creating a new module within the Distributed Geothermal Market Demand Model (dGeo). dGeo is an agent-based modeling tool for distributed geothermal resources; it can investigate potential on a nationwide or statewide scale using geospatial data for all 50 states and thermal demands for existing buildings. This process allows for high-level estimates of technical and economic potential for ambient-temperature loop districts across the United States. Using GHEDesigner, a lookup table was created to size borehole fields for different thermal loads and ground conditions experienced across the country. A cost and financing structure, along with incentives, were applied. Cost estimates include costs for the distribution network, borehole field installation and operation, and circulation pump operation, while savings are calculated based on agent energy bills. This newly developed module can be used for assessing which areas of the country have the highest potential for agent benefits from ambient-temperature loop installation and assess the impact of different costing and pricing future scenarios. While the code is still under development and nationwide simulations are ongoing, initial results for two states are provided. Future work includes expanding the module to consider mixed residential and commercial districts and considering multiple costing scenarios.

ambient temperature loop↗

National Modeling of Geothermal District Energy Systems with Ambient-Temperature Loops Using dGeo

Geothermal district energy systems (DES) with ambient-temperature loops, also known as thermal energy networks, are one option for decarbonizing space heating and cooling loads. Geothermal fifth-generation DES include an "ambient" temperature thermal loop that connects heat pumps at each building with thermal balancing sources such as geothermal borehole fields. Heating and cooling are provided via a water-source heat pump at each end-user. This project seeks to analyze the nationwide potential for ambient-temperature loop districts by creating a new module within the Distributed Geothermal Market Demand Model (dGeo). dGeo is an agent-based modeling tool for distributed geothermal resources; it can investigate potential on a nationwide or statewide scale using geospatial data for all 50 states and thermal demands for existing buildings. This process allows for high-level estimates of technical and economic potential for ambient-temperature loop districts across the United States. A lookup table was created using GHEDesigner to size borehole fields for different thermal loads and ground conditions experienced across the country. A cost and financing structure, along with incentives, were applied. Cost estimates include costs for the distribution network, borehole field installation and operation, and circulation pump operation, while savings are calculated based on energy bills for building owners (agents). This newly developed module can be used for assessing which areas of the country have the highest potential for agent benefits from ambient-temperature loop installation and assess the impact of future cost and price scenarios. Initial results for statewide analysis (for Vermont) and nationwide (for United States) are provided. Future work includes expanding the module to consider mixed residential and commercial districts as well as evaluating multiple cost scenarios.

ambient-temperature loop↗

A multi-agent approach to distribution system fault section estimation in smart grid environment

We report that Multi-Agent Systems (MAS) are seen from different areas as one of the paramount trends for the next generation of power systems. Numerous published studies about MAS discuss its utilization in power distribution networks but none focuses on the prior step to restoration and self-healing that is fault section estimation. This paper aims to show how MAS can improve the utilities’ reliability indexes and consumer satisfaction by overcoming the multiple fault section estimation problem. In order to do this, the authors considered using MAS as a means of communication between smart meters. The purpose of smart meters usage is to employ devices that are already present in smart grids, mainly because of their reading and saving data capacity. The proposed method was tested on a radial feeder generated by the authors. The network was built on HYPERSIM, a software platform of OPAL-RT Technologies. The simulation results show that this MAS provides speed, efficiency, and automation for the process of fault section estimation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Data-Driven Preemptive Voltage Monitoring and Control Using Probabilistic Voltage Sensitivities

Increased penetration levels of distributed variable renewable generation can cause random voltage fluctuations and violations at multiple nodes. Traditional methods of voltage control typically involve reactionary responses of capacitor banks, tap changers, and recently even smart inverters. But because of the lack of foresight in voltage violations, these controls are ineffective to completely mitigate the issue. Therefore, new methods of predicting voltage violations subject to random power injection changes in the distribution network are needed, which can be used to guide optimal and dynamic methods of voltage control. This work lays the foundation for such preemptive voltage monitoring and control by proposing an analytical and sensor data-driven voltage sensitivity analysis method. Driven by stochastic data and forecasts, the method can be used to develop probabilistic voltage sensitivities and consequently to predict system nodes with high likelihood of voltage limit violations. The effectiveness of this method is tested on IEEE 69-node distribution system integrated with distributed solar. The results demonstrate the proposed method's ability to successfully predict nodes with high probability of voltage violations for a specific time-series simulation. The results also demonstrate the ability to guide timely power injection control actions to mitigate future voltage violations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Mechanical Solutions Scan Report

Power lines, poles, and towers are the backbone of the United States (U.S.) electric-power grid. These transmission and distribution networks route electricity from generator to loads. The characteristics of these routes are rapidly changing -- trending towards decentralized renewable generation, electric heating, vehicle charging, and large data-center loads. Coupled with aging infrastructure and the increased frequency of extreme weather events, there is concern about the future reliability and transmission capacity of conductors and adjacent components. This scan report seeks to provide an overview of mechanical solutions to challenges caused by extreme weather events associated with components of transmission and distribution infrastructure, including conductor heat sag, ice accumulation, wind, and wildfire. Many options could increase transmission capacity or reliability, and these are at various stages of technological readiness. Some have only been lab tested, while some have been widely deployed in the U.S. or overseas for decades. The solution categories and providers featured in this report are intended to be comprehensive at the time of publication and to serve as a reference for decision-makers concerned about transmission and distribution reliability. There are two other categories of large, complex solutions, which are not covered in this report: replacing existing conductors with advanced conductors and implementing digital grid enhancing technologies. A separate scan report titled “Advanced Conductor Scan Report,” which discusses advanced carbon-core conductors, was published by the Idaho National Laboratory (INL) in 2023. Information on digital technologies, such as dynamic line ratings, power-flow controllers, and other power electronics and communications-based devices, can be found on the Grid- Enhancing Technologies landing page. Mechanical grid-enhancing technologies, or solutions covered in this report, often do not require full equipment replacement and do not rely on digital components. Mechanical technologies are overlooked because they may be older, simpler, or seemingly “more obvious” than digital or carbon-core technologies. However, it is wise to consider mechanical solutions in a thorough evaluation of grid enhancing technology solutions.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Unsupervised Learning for Equitable DER Control: Preprint

In the context of managing distributed energy resources (DERs) within distribution networks (DNs), this work focuses on the task of developing local controllers. We propose an unsupervised learning framework to train functions that can closely approximate optimal power flow (OPF) solutions. The primary aim is to establish specific conditions under which these learned functions can collectively guide the network towards desired configurations asymptotically, leveraging an incremental control approach. The flexibility of the proposed methodology allows to integrate fairness-driven components into the cost function associated with the OPF problem. This addition seeks to mitigate power curtailment disparities among DERs, thereby promoting equitable power injections across the network. To demonstrate the effectiveness of the proposed approach, power flow simulations are conducted using the IEEE 37-bus feeder. The findings not only showcase the guaranteed system stability but also underscore its improved overall performance.

asymptotic stability↗

2022 Peer Review Project Summary: Advanced Protection for Microgrids and DER in Secondary Networks and Meshed Distribution Systems

Although there are increasing numbers of distributed energy resources (DERs) and microgrids being deployed, current IEEE and utility standards generally strictly limit their interconnection inside secondary networks. Secondary networks are low-voltage meshed (non-radial) distribution systems that create redundancy in the path from the main grid source to each load. This redundancy provides a high level of immunity to disruptions in the distribution system, and thus extremely high reliability of electric power service. There are two main types of secondary networks, called grid and spot secondary networks, both of which are used worldwide. In the future, primary networks in distribution systems that might include looped or meshed distribution systems at the primary-voltage (mediumvoltage) level may also become common as a means for improving distribution reliability and resilience. The objective of this multiyear project is to increase the adoption of microgrids in secondary networks and meshed distribution systems by developing novel protection schemes that allow for safe reliable operation of DERs in secondary networks. We will address these challenges by working with the appropriate stakeholders of secondary network operators, protection vendors, and standards committee. The outcomes of this project include: a) development and/or demonstration of candidate methods for enabling protection of secondary networks containing high levels of DER; b) development of modeling and testing tools for protection systems designed for use with secondary networks including DERs; and c) development of new industrial partnerships to facilitate widespread results dissemination and eventual commercialization of results as appropriate.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimizing infrasound observations for sample return capsule re-entry: Insights from OSIRIS-REx and Hayabusa2

The atmospheric entry of meteoroids presents a rare and unpredictable phenomenon, posing challenges for systematic observation and detailed characterization. Such events are nonetheless critical for advancing understanding of acoustic wave propagation, atmospheric structure, and entry dynamics. In contrast, sample return capsules (SRCs) from space missions follow well constrained re-entry trajectories, enabling planned observations of shock wave generation and propagation under controlled conditions. This study compares two SRC atmospheric entries, Hayabusa2 in 2020 and OSIRIS-REx in 2023, to assess how different infrasound array configurations influence shock wave detection and trajectory validation. Hayabusa2’s re-entry was monitored using a distributed network of 28 portable infrasound sensors across seven arrays in Woomera, Australia, permitting three-dimensional reconstruction of the trajectory and analysis of wave characteristics. For OSIRIS-REx, a compact four-sensor array deployed near Eureka Airport provided trajectory confirmation through arrival-time differences and back-azimuth estimates. Spectral and waveform analyses revealed differences in signal properties associated with variations in entry angle and velocity. The results illustrate both the strengths and the limitations of the deployed array configurations. The dense and distributed arrays during Hayabusa2’s re-entry enabled detailed trajectory reconstruction, whereas the compact array at Eureka primarily provided confirmation of signal coherence and back-azimuth consistency. These case studies highlight that even relatively small arrays, if located close to the predicted ground track, can still capture useful information on arrival direction and timing. Such insights provide practical guidance for planning future observational campaigns of SRC returns and other controlled atmospheric entries, and may also inform approaches to opportunistic observations of meteoroid events and other atmospheric acoustic phenomena.

celestial mechanics: orbit determination↗

SIW21-95: Hybridizing Synchronous Condensers with Grid-Forming Battery Energy Storage Systems

One of the main challenges associated with deployment of high shares of inverter-based resources (IBRs) in power grid is not only reduced system inertia but also degrading system strength that may cause severe stability impacts. A minimum level of system strength is needed for the power system to remain stable under normal conditions and to return to a steady state condition following a system disturbance. Significant system strength reduction is expected in almost all planned areas for solar and wind generation deployment. Synchronous condensers (SC) have been considered as one main technology to address the system strength issues for the areas with high levels of IBRs. SCs can help improving reliability and resiliency of power system but they do not provide the full range of services needed by power systems for reliable and economic integration of high shares of inverter-coupled variable generation such as PV generation. Services related to active power controls cannot be provided by SCs due to lack of prime mover. Even for provision of reactive power SCs have certain constraints based on their thermal and stability limits. NREL has been conducting research on a hybridized concept that combines SCs with grid forming (GFM) battery energy storage systems (BESS). This super flexible AC transmission system (SuperFACTS) that combines these two technologies in a single plant under the same controller offers a unique scalable set of services to the power system at all levels (transmission, sub-transmission, distribution, islands and isolated microgrids). Depending on use cases, SuperFACTS can be controlled to provide fully dispatchable and flexible operation using energy storage component, provide a full range of existing and future ancillary and reliability services to the grid (similar or better than conventional sources), maintain adequate levels of grid strength and inertia, and provide fault current for proper operation of protection systems. Therefore, this economic and easy to commercialize solution has potential for significant impacts on certain segments of global energy sector. All types of gird services (market based, reliability and resiliency) can be provided by SuperFACTS plants. GFM BESS can act as a self-black start source for each SuperFACTS module, which in turn can act a black start resource for co-located PV and wind power plants, segments of transmission and distribution networks, for conventional power plants, etc. The issue of in-rush currents during black start is addressed by overcurrent capability of SCs. In this paper we describe the results of modeling for SuperFACTS concept.

grid forming↗

A review of technical and regulatory limits for hydrogen blending in natural gas pipelines

We report there is rising interest globally in the use of hydrogen for the provision of electricity or heat to industry, transport, and other applications in low-carbon energy systems. While there is attention to build out dedicated hydrogen infrastructure in the long-term, blending hydrogen into the existing natural gas pipeline network is also thought to be a promising strategy for incorporating hydrogen in the near-term. However, hydrogen injection into the existing gas grid poses additional challenges and considerations related to the ability of current gas infrastructure to operate with blended hydrogen levels. This review paper focuses on analyzing the current understanding of how much hydrogen can be integrated into the gas grid from an operational perspective and identifies areas where more research is needed. The review discusses the technical limits in hydrogen blending for both transmission and distribution networks; facilities in both systems are analyzed with respect to critical operational parameters, such as decrease in energy density, increased flow speed and pressure losses. Safety related challenges such as, embrittlement, leakage and combustion are also discussed. The review also summarizes current regulatory limits to hydrogen blending in different countries, including ongoing or proposed pilot hydrogen blending projects.

08 HYDROGEN↗

Real-Time Testbed for Studying Cyberattacks and Defense in DER-integrated Smart Inverter Systems

In this paper, we propose a Hardware-in-the-Loop (HIL) simulation testbed suitable for the implementation and testing of realistic cyberattacks on grid-tied smart inverter systems integrated with Distributed Energy Resources (DER) that use the Distributed Network Protocol-3 (DNP3) protocol for communications between grid components. Specifically, our testbed combines a Real-Time Digital Simulator (RTDS) NovaCor device, outfitted with GNETx2 network interface cards, a gridtied DER topology implemented via the RTDS software package RSCAD, and a custom virtual network that emulates a man in the middle attacker. The Man-in-the-Middle (MITM) attacker captures DNP3 traffic and falsifies telemetry data in DNP3 packets to trigger unwarranted commands from a DNP3 controller that exploit smart inverter grid support functions. We choose DNP3 and implement grid support functions according to the IEEE Std. 1547-2018 mandated for the interconnection and interoperability of DER power systems with associated power components. Furthermore, we develop a protocol payload agnostic attack detection framework that leverages the round-trip time (RTT) anomalies between DNP3 requests and responses and can detect the presence of attacks without having to analyze the payload’s contents, while balancing trade-offs between false alarm counts, missed detections, and time to detection. To facilitate further research, we publicly release benign and attack network traffic exchanged between various sensors, controllers, and actuators in our grid-tied inverter testbed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Penalty Scheme for Mitigating Uninstructed Deviation of Generation Outputs From Variable Renewables in a Distribution Market

With rapid growth of distributed renewable generation, the establishment of electricity distribution markets has attracted widespread concerns. Different from existing transmission grid-scale electricity markets, an electricity distribution market is featured by numerous small-scale prosumers, and zero marginal cost and intermittency of renewable generation units. Against this background, this paper first extends an average pricing market (APM) mechanism for pricing renewable generation outputs with zero marginal cost in the distribution network concerned. Then, to mitigate the uninstructed volatility of renewable generation outputs and power demand, a penalty scheme is proposed for deviations between the real-time demand/output and market cleared bid/offer, with frequency regulation service (FRS) from energy storage systems (ESSs) considered. It is proved that the market volatility can be well controlled within an expected limit through properly setting the penalty prices for load demand and generation output fluctuations. Also, with this mechanism a non-negative market surplus could always be attained. Case studies are carried out to demonstrate the feasibility and efficiency of the proposed distribution market mechanism and penalty scheme.

electricity distribution market↗

Sensing Service Transformer Secondary Currents using Planar Magnetic Pick-up Coils

The rapid deployment of distributed energy resources (DERs) is creating stresses on utility assets in the distribution networks. The service transformer, which is the most commonly used utility asset is often not monitored, since the cost of available sensing solutions is as high as the transformer itself. This paper presents a method to use an array of printed circuit board coils to intelligently monitor North American pole top service transformers. The approach, uses a novel, self-calibrating algorithm to infer the fixed geometry of the installation, by recording data over an extended period of time. The proposed method can enable rapid installation of a non-intrusive sensor that can be used to monitor loading levels of the distribution transformer. Furthermore, these sensors can help in planning, prognostics and advanced situational awareness for utilities.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Modular HF Isolated MV String Inverters Enable a New Paradigm for Large PV Farms

The “Modular HF Isolated MV String Inverters Enable a New Paradigm for Large PV Farms” project focuses on exploring alternative power converter and system-level plant configurations to achieve the lowest cost and highest energy output for a given solar plus storage (e.g., PV + battery) plant, including the use of medium voltage (MV) collection while taking into account detailed models of all elements. To realize this objective, four approaches were utilized (i) employ a novel Medium Voltage String Inverter (MVSI) topology (soft switching solid state transformer – S4T) to convert 1000 Vdc to 4.16 kVac; (ii) plant collection using standard, low-cost overhead MV distribution network; (iii) enable energy storage integration without additional converter cost to achieve dispatchability of the PV resource; and (iv) provide advanced functionality (autonomous operation, track ISO signals for dynamic balancing and ancillary services, and PV farm operation as a virtual grid resource). Subsequently and in alignment with the previously mentioned approaches, the project was structured in five efforts (i) S4T MVSI simulation and design; (ii) system analysis and storage optimization; (iii) financial analysis; (iv) power converter prototype build and test; and (v) regulatory and commercial impact study. The outcomes provided by each effort can be summarized as follows (i) Project explored the use of MV AC distribution architecture for hybrid PV+storage utility-scale PV farms; (ii) Detailed loss and LCOE analysis for AC and DC side BESS architecture, including multiple converter topologies, as well as for proposed MVSI/MDCT systems; (iii) MVSI was built and holds promise but needs lower-cost high-voltage Si-C devices, which does not seem possible in the near term; (iv) MDCT provides a simpler modular building block – validated through HIL and farm level modeling, simulation and experimental validation; (v) 300 kVA MDCT prototype built and tested, technology is being commercialized; and (vi) Regulatory model of utility building PV plants, where PV panels are treated as DC generation (IPP), seems viable and can allow improved grid integration.

14 SOLAR ENERGY↗

Distributed Algorithm for Volt-VAr Optimization in Unbalanced Distribution System

Conservation voltage reduction (CVR) is implemented in the distribution system to reduce the voltage along the feeder with the objective to reduce the power consumption. Due to the increased penetration of distributed generators in the distribution system the centralized control is cumbersome. Hence, in this paper, a distributed algorithm is proposed for volt-var optimization (VVO) with CVR objective in a three-phase unbalanced distribution network. The proposed method is based on alternating direction method of multipliers (ADMM) algorithm. Mathematically the problem is formulated as a convex optimization problem with reactive power support from smart inverters. The convexity guarantees the solution obtained using the proposed method is a converged solution. The proposed method is validated on IEEE 4-bus and 13-bus three-phase unbalanced systems.

ADMM↗

A Survey of Open-Source Tools for Transmission and Distribution Systems Research

This work presents a review of open-source electric power transmission and distribution systems analysis tools suitable for use by industry professionals and academic researchers. Due to the high complexity of the electric grid, there exist numerous tools and extensive research pertaining to nearly every aspect of the design, operation, and control of transmission and distribution networks. In addition to the commercial tools, a wide range of free, open-source tools, models, and data usable by the scientific community for related research have been developed by different organizations, including both international and US universities and national laboratories. However, due to the absence of a catalog of available tools, models and data, researchers often lack a knowledge of existing capabilities and may develop duplicative software and tools. Increasing awareness of these available resources seeks to accelerate their broader use, leading to more efficient and standardized grid analysis. This review paper (which is part of a larger survey effort that studied over 400 tools in the transmission, distribution, buildings, and electric vehicles space) outlines selected open-source resources that have been developed in power transmission and distribution systems research. It is anticipated that this work can serve as a guide for industry and academic researchers alike, ensuring that research efforts are well-channeled.

24 POWER TRANSMISSION AND DISTRIBUTION↗