Search NASA⌕ Search

SEARCH · Search NASA

Results for “Doppler backscattering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Development of a 0.5 micrometer incoherent Doppler lidar for space application

This paper describes the current status of a prototype 0.53 micrometer Doppler lidar system under development at RCA. This system consists of a frequency doubled Nd:YAG laser constrained to yield a narrow bandwidth, single frequency pulse, a Fabry-Perot Inteferometer (FPI) using an Image Plane Detector (IPD) to measure the backscatter spectrum for each pulse and a Data Acquisition System (DAS) to sample, store, and analyze the backscattered signal. These individual subsystem components have been assembled and preliminary atmospheric testing has recently begun. Atmospheric backscatter spectra are presented which demonstrate the capabilities of this system to distinguish between return signals from aerosols, molecules, and clouds.

Rosenberg, A.↗

Detection of CFRP Composite Manufacturing Defects Using a Guided Wave Approach

NASA Langley Research Center is investigating a guided-wave based defect detection technique for as-fabricated carbon fiber reinforced polymer (CFRP) composites. This technique will be extended to perform in-process cure monitoring, defect detection and size determination, and ultimately a closed-loop process control to maximize composite part quality and consistency. The overall objective of this work is to determine the capability and limitations of the proposed defect detection technique, as well as the number and types of sensors needed to identify the size, type, and location of the predominant types of manufacturing defects associated with laminate layup and cure. This includes, porosity, gaps, overlaps, through-the-thickness fiber waviness, and in-plane fiber waviness. The present study focuses on detection of the porosity formed from variations in the matrix curing process, and on local overlaps intentionally introduced during layup of the prepreg. By terminating the cycle prematurely, three 24-ply unidirectional composite panels were manufactured such that each subsequent panel had a higher final degree of cure, and lower level of porosity. It was demonstrated that the group velocity, normal to the fiber direction, of a guided wave mode increased by 5.52 percent from the first panel to the second panel and 1.26 percent from the second panel to the third panel. Therefore, group velocity was utilized as a metric for degree of cure and porosity measurements. A fully non-contact guided wave hybrid system composed of an air-coupled transducer and a laser Doppler vibrometer (LDV) was used for the detection and size determination of an overlap By transforming the plate response from the time-space domain to the frequency-wavenumber domain, the total wavefield was then separated into the incident and backscatter waves. The overlap region was accurately imaged by using a zero-lag cross-correlation (ZLCC) imaging condition, implying the incident and backscattered waves are in phase over the overlap boundaries.

Hudson, Tyler B.↗

Spall and subsequent recompaction of copper under shock loading

Research was undertaken to study spall and subsequent recompaction of oxygen-free high-thermal-conductivity copper using a single-stage large-bore light gas gun capable of planar impacts. Gun experiments were conducted that produced an initial spall in the target with a subsequent recompaction of the spall damage/layer by the use of layered impactors. Symmetric spall experiments at similar conditions were also conducted as a control to the recompaction experiments. Photonic Doppler velocimetry was used to obtain the velocity history of the target’s back surface; these velocity histories were analyzed, and the results were compared to numerical simulations. After recovery of selected samples, the microstructure was analyzed using optical imaging microscopy and electron backscatter diffraction. Recompaction waves were clearly observed in the time-resolved data obtained at the back surface of the targets. Two different series of experiments were performed to understand the effect of damage morphology on the stress required for spall recompaction. In the initial series, the peak pressure of the first shock was systematically increased to alter the amount of damage in the material. While in the second series, the peak pressure of the second shock was increased, keeping the magnitude of the first shock relatively constant to understand the effect of peak stress on the recompaction process. Findings clearly show that recompaction results in a perturbed band of the microstructure at the location of the expected spall plane in all cases except where the peak stress of the second shock is lower than the critical value.

, recompaction↗

Target Calibration: Retro-Reflection Mechanisms at 2 Micron

With the growing use of 2-micrometer eye-safe solid-state laser transmitters in coherent Doppler lidar applications, there is increased interest in the reflectance properties of hard target calibration materials at this wavelength. One of the factors to be considered is the polarization characteristic of the transmitter/receiver. The two fundamental lidar systems are either based upon the backscattering of linearly polarized or circularly polarized light. Consequently, the response of calibration materials to the particular state of polarization of the incident radiation is an important consideration. Ideally the calibration materials should have a similar reflectance response to that of the remote scattering medium that is being observed. Also the material should be most efficiently adapted to the polarization characteristics of the lidar system. There are two measurement parameters that are useful in presenting the characteristics of polarization of reflecting materials. The first is the linear polarization ratio: mu (sub l) =I (sub ol)/I (sub sl), where ol denotes opposite linear and sl denotes same linear. The second is circular polarization ratio: mu (sub c) = I (sub sc)/I (sub oc) where ol denotes opposite circular and sc denotes same circular. Notice that the ratios are inverted with respect to same polarization. It is the relative values of these polarization ratios that are used to characterize the retro-reflectance mechanism. Measurement of these parameters is conveniently obtained by using the Stokes vectors corresponding to the polarized backscatter at and near the retro-angle.

Haner, David A.↗

Radar Wind Profiler (RWP) and Radio Acoustic Sounding System (RASS) Instrument Handbook

The radar wind profiler (RWP) is an active remote-sensing instrument that can routinely, and virtually unattended, observe wind and turbulence in the troposphere through scattering from clear-air irregularities of the atmospheric refractive index (Gage and Balsley 1978). The principle of Doppler radars in general is based on sending electromagnetic pulses in the vertical and several tilted directions (vertical and oblique beams) and measuring the signal that is scattered back by atmospheric turbulence at all heights and received at the antenna. The RWPs provides measurements of backscattered signal strength and wind profiles nominally between 0.1 km and 6 km. The RWP operation assumes that the wind field is homogeneous over the spatial separation of the antenna beams, which is a safe assumption under stable atmospheric conditions. However, the wind may be different between the beams due to significant changes in the wind field, resulting in erroneous wind calculations. Therefore, the radial measurements are averaged over a sufficient time period to validate the assumption of homogeneity.

54 ENVIRONMENTAL SCIENCES↗

Laser Doppler anemometer for water tunnel applications.

A laser Doppler anemometer for three-dimensional velocity measurement in liquids and gases under a wide range of laboratory conditions has been developed. The instrument is particularly well suited for water tunnel applications. It is portable, easily aligned, and inexpensive (excluding electronic units). It operates in backscatter or forward scatter mode. In both cases all optical components, including laser and photomultiplier, remain on a common base. The system has built-in traversing capability and an aiming device for visualizing the focal (test) point. Design details and representative velocity measurements are given.

Bossel, H. H.↗

Comparison of 2- and 10-micron coherent Doppler lidar performance

The performance of 2- and 10-micron coherent Doppler lidar is presented in terms of the statistical distribution of the maximum-likelihood velocity estimator from simulations for fixed range resolution and fixed velocity search space as a function of the number of coherent photoelectrons per estimate. The wavelength dependence of the aerosol backscatter coefficient, the detector quantum efficiency, and the atmospheric extinction produce a simple shift of the performance curves. Results are presented for a typical boundary layer measurement and a space-based measurement for two regimes: the pulse-dominated regime where the signal statistics are determined by the transmitted pulse, and the atmospheric-dominated regime where the signal statistics are determined by the velocity fluctuations over the range gate. The optimal choice of wavelength depends on the problem under consideration.

Frehlich, Rod↗

Wave like signatures in aerosol optical depth and associated radiative impacts over the central Himalayan region

Doppler Lidar and Multi-Filter Rotating Shadowband Radiometer (MFRSR) observations are utilized to show wave like signatures in aerosol optical depth (AOD) during daytime boundary layer evolution over the Himalayan region. Fourier analysis depicted 60–80 min periods dominant during afternoon hours, implying that observed modulations could be plausible reason for the AOD forenoon–afternoon asymmetry which was previously reported. Inclusion of wave amplitude in diurnal variation of aerosol radiative forcing estimates showed ~40% additional warming in the atmosphere relative to mean AOD. The present observations emphasize the importance of wave induced variations in AOD and radiation budget over the site.

Aerosol optical depth↗

Comparison of scattering ratio profiles retrieved from ALADIN/Aeolus and CALIOP/CALIPSO observations and preliminary estimates of cloud fraction profiles

The space-borne active sounders have been contributing invaluable vertically resolved information of atmospheric optical properties since the launch of Cloud-Aerosol Lidar and Infrared Pathfinder Satellite Observation (CALIPSO) in 2006. To build long-term records from space-borne lidars useful for climate studies, one has to understand the differences between successive space lidars operating at different wavelengths, flying on different orbits, and using different viewing geometries, receiving paths, and detectors. In this article, we compare the results of Atmospheric Laser Doppler INstrument (ALADIN) and Cloud-Aerosol Lidar with Orthogonal Polarization (CALIOP) lidars for the period from 28 June to 31 December 2019. First, we build a dataset of ALADIN–CALIOP collocated profiles (Δdist<1°; Δtime<6 h). Then we convert ALADIN's 355 nm particulate backscatter and extinction profiles into the scattering ratio vertical profiles SR(z) at 532 nm using molecular density profiles from Goddard Earth Observing System Data Assimilation System, version 5 (GEOS-5 DAS). And finally, we build the CALIOP and ALADIN globally gridded cloud fraction profiles CF(z) by applying the same cloud detection threshold to the SR(z) profiles of both lidars at the same spatial resolution. Before comparing the SR(z) and CF(z) profiles retrieved from the two analyzed lidar missions, we performed a numerical experiment to estimate the best achievable cloud detection agreement CDA norm (z) considering the differences between the instruments. We define CDA norm (z) in each latitude–altitude bin as the occurrence frequency of cloud layers detected by both lidars, divided by a cloud fraction value for the same latitude–altitude bin. We simulated the SR(z) and CF(z) profiles that would be observed by these two lidars if they were flying over the same atmosphere predicted by a global model. By analyzing these simulations, we show that the theoretical limit for CDA$_{norm}^{theor}$(z) for a combination of ALADIN and CALIOP instruments is equal to 0.81±0.07 at all altitudes. In other words, 19 % of the clouds cannot be detected simultaneously by two instruments due to said differences. The analyses of the actual observed CALIOP–ALADIN collocated dataset containing ~78 000 pairs of nighttime SR(z) profiles revealed the following points: (a) the values of SR(z) agree well up to ~3 km height. (b) The CF(z) profiles show agreement below ~3 km, where ~80 % of the clouds detected by CALIOP are detected by ALADIN as expected from the numerical experiment. (c) Above this height, the CDA$_{norm}^{obs}$(z) reduces to ~50 %. (d) On average, better sensitivity to lower clouds skews ALADIN's cloud peak height in pairs of ALADIN–CALIOP profiles by ~0.5±0.6 km downwards, but this effect does not alter the heights of polar stratospheric clouds and high tropical clouds thanks to their strong backscatter signals. (e) The temporal evolution of the observed CDA$_{norm}^{obs}$(z) does not reveal any statistically significant change during the considered period. This indicates that the instrument-related issues in ALADIN L0/L1 have been mitigated, at least down to the uncertainties of the following CDA$_{norm}^{obs}$(z) values: 68±12 %, 55±14 %, 34±14 %, 39±13 %, and 42±14 % estimated at 0.75, 2.25, 6.75, 8.75, and 10.25 km, respectively.

54 ENVIRONMENTAL SCIENCES↗

CRYSTAL-FACE Polarization Lidar Research

The University of Alaska Fairbanks (UAF) Polarization Diversity Lidar (PDL, Sassen 1994) participated in the July 2002 CRYSTAL-FACE field campaign, shortly after the PI moved from the University of Utah to UAF. The truck-mounted PDL is an advanced dual wavelength (1.06 and 0.532 micron), high resolution (0.1-s by 1.5-m), scanning lidar system designed as a testbed for evaluating laser backscatter depolarization techniques for the study of clouds and aerosols in the atmosphere. The main goals identified in our proposal for the CRYSTAL-FACE experiment were, i) the characterization of Florida thunderstorm anvil macrophysical and microphysical properties from lidar backscattering and depolarization, ii) the study of thin to subvisual tropopause-topped subtropical cirrus, iii) the search for indirect cloud effects of trans- Atlantic advected Saharan dust storm aerosols on clouds, and iv) the investigation of melting layer effects on lidar and multi-wavelength Doppler radar measurements in precipitation. Although we experienced adversity in the field during the campaign, sufficient data was collected to begin addressing these topics, and several conference presentations, three journal articles, and one book chapter have resulted from the data analysis effort supported by this grant. (PDL operations were delayed by FAA concerns over the initial sighting at the Kendall-Tamiami Airport, and a brief but major laser breakdown was experienced during the re- setup at the remote Ochopee Everglades site that also supported the N-POL radar.) All lidar data collected by the PDL system were processed and quality checked, and submitted to the CRYSTAL-FACE data archive in a timely manner.

Sassen, Kenneth↗

Radiological Shielding Design for the Neutron Backscattering Spectrometer EMU

In this paper we present modelling and design of compact radiation shielding required for operation of the EMU instrument, located at Australia's OPAL nuclear reactor. The acceptance criteria for the shielding design were (i) safety - dose rate ≤ 3 μSv/h at external surfaces of the instrument's experimental area, (ii) floor load limit < 20 tons/m{sup 2}, (iii) low cost and (iv) for maintenance purposes 'easy access' to components of the instruments. The EMU instrument is a cold neutron backscattering spectrometer designed to measure inelastic neutron scattering. Its distinctive feature is that it has a tight elastic energy transfer resolution, of about 1 μeV. The instrument provides unique opportunities to study diffusion in complex materials, e.g. water molecules in confinement, polymers or biological molecules, particularly in the Asia-Oceania region. EMU is the first instrument located on the CG3 neutron beam line of the OPAL Neutron Guide Hall (NGH). A pre-existing evacuated neutron guide of dimensions 200 mm (height) x 50 mm (width) feeds into the shared EMU/KOOKABURRA pre-monochromator bunker shielding assembly, and its bottom cross section will be intercepted ∼200 mm further in air by the highly orientated pyrolytic graphite (HOPG) EMU pre-monochromator (take-off angles from 125.4 deg. to 148 deg.). The bunker shielding assembly for EMU also contains a beryllium filter and Focusing Guide Section D (FGD, 170 mm (height) x 50 mm (width)). To accommodate the range of take-off angles Pb cylindrical shielding blocks of radius 140 mm and 500 mm height have been designed. These blocks will be located at the section of the bunker where the neutron beam will exit towards the experimental area and they will reside on top of a hollow steel base (sides 10 mm thick), on which they move by sliding and are integrated with the tertiary shutter. The experimental area is enclosed by a concrete wall of 2.5 m height and 300 mm thickness, shared with the KOOKABURRA instrument, Gyprock Plasterboard panels with viewing windows, a wall from the Out-of-Pile Bunker and the CG3 shielding. The neutron beam enters the experimental area via the tertiary shutter, into the Focusing Guide Section C (FGC), which has an entrance guide cross-section of 158 mm (height) x 79 mm (width) and exit guide cross-section of 149 mm (height) x 85 mm (width) and is of length 816 mm. The vacuum chamber of FGC will be connected to the vacuum chamber of the Background Chopper (BC, disc of outer radius 350 mm). Focusing Guide Section B (FGB) is aligned with FGC and its vacuum shared with the BC vacuum. The FGB has an exit guide cross section of 50 mm (height) x 49 mm (width) and is of length 4046 mm, which will focus the neutron beam vertically and horizontally towards the Al window entrance (0.82 mm thickness, labelled N16) of the Scattering Tank assembly (constructed from 20 mm - 40 mm thickness stainless steel and will be under vacuum < 1 x 10{sup -3} mbar). Inside the Scattering Tank there is another section of Focusing Guide (FGA), with an exit guide cross-section of 30 mm (height) 30 mm (width) and of length 417 mm. The neutron beam exiting the FGA will be reflected by the HOPG crystal pieces of the Graphite Chopper (GC) towards the Backscattering Monochromator (BM). The reflected neutron beam will first pass through the other Al window (0.82 mm thickness, labelled N17) of the Scattering Tank and then enter into a flight tube (steel of 10 mm thickness). The BM is formed in an 1800 mm spherical radius array of Si crystal elements (0.87 mm thickness) and is oscillated by the linear motor Doppler Drive. The neutron beam will be reflected back at 180 deg. from, and focussed by the BM to reenter the Scattering Tank through the N17 Al window. It will then pass through the GC (HOPG crystals are rotated out of the way) and will reach the scattering sample of interest to the instrument end user. Also, inside the Scattering Tank there will be {sup 3}He linear position-sensitive detectors, and Analyser Arrays formed in an 1800 mm radius spherical arrays of Si crystal elements (0.87 mm thickness) glued on aluminium support frames (10 mm thickness) and span ∼160 deg. arc.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

The Double Edge Technique for Doppler lidar wind measurement

The edge technique utilizes the edge of a high spectral resolution filter for high accuracy wind measurement using direct detection lidar. The signal is split between an edge filter channel and a broadband energy monitor channel. The energy monitor channel is used for signal normalization. The edge measurement is made as a differential frequency measurement between the outgoing laser signal and the atmospheric backscattered return for each pulse. As a result, the measurement is insensitive to laser and edge filter frequency jitter and drift at a level less than a few parts in 10(exp 10). We will discuss the methodology of the technique in detail, present a broad range of simulation results, and provide preprints of a journal article currently in press.

Korb, C. Laurence↗

Water Surface Currents, Short Gravity-Capillary Waves and Radar Backscatter

Despite their importance for air-sea interaction and microwave remote sensing of the ocean surface, intrinsic properties of short gravity-capillary waves are not well established. This is largely due to water surface currents and their effects on the direct measurements of wave parameters conducted at a fixed point. Frequencies of small scale waves propagating on a surface which itself is in motion, are subject to Doppler shifts. Hence, the high frequency tail of the wave spectra obtained from such temporal observations is smeared. Conversion of this smeared measured-frequency spectra to intrinsic-frequency (or wavenumber) spectra requires corrections for the Doppler shifts. Such attempts in the past have not been very successful in particular when field data were used. This becomes evident if the amplitude modulation of short waves by underlying long waves is considered. Microwave radar studies show that the amplitude of a short wave component attains its maximum value near the crests and its minimum in the troughs of the long waves. Doppler-shifted wave data yield similar results but much larger in modulation magnitude, as expected. In general, Doppler shift corrections reduce the modulation magnitude. Overcorrection may result in a negligible modulation or even in a strong modulation with the maximum amplitude in the wave troughs. The latter situation is clearly contradictory to our visual observations as well as the radar results and imply that the advection by currents is overestimated. In this study, a differential-advection approach is used in which small scale waves are advected by the currents evaluated not at the free surface, but at a depth proportional to their wavelengths. Applicability of this approach is verified by the excellent agreement in phase and magnitude of short-wave modulation between results based on radar and on wave-gauge measurements conducted on a lake.

Atakturk, Serhad S.↗

Capturing plume behavior in complex terrain: an overview of the Nevada National Security Site Meteorological Experiment (METEX21)

METEX21 was an atmospheric tracer release experiment executed at the Department of Energy’s Nevada National Security Site (NNSS) in the southwestern U.S to study terrain-induced wind and thermodynamic conditions that influence local-scale (<5-km) plume transport under varying atmospheric forcing conditions. Meteorological observations were collected using 10-m tall meteorological towers, 2-m tall tripods with 3-d sonic anemometers, a 3-m tall eddy covariance flux tower, Doppler profiling lidars, Doppler scanning lidars, weather-balloon launched radiosondes, and a tethered balloon equipped with wind, temperature, and aerosol sensors at heights up to 800 m. A smoke tracer was released along three transects in the horizontal and vertical directions and observed with video cameras, aerosol sensors and lidars (via aerosol backscatter). The observations showed evidence of large-scale/synoptic transience as well as local-scale upslope and downslope flows, along-axis valley flows, recirculation eddies on leeward slopes, and periods of strong shear and veer aloft. The release days were classified as either synoptically-driven or locally-driven, and a single case day is presented in detail for each. Synoptically-forced days show relatively narrow smoke plumes traveling down the valley from north to south (with the predominant wind direction), with little deviation in transport direction regardless of the elevation or ground locations of the smoke releases, except near the presence of leeside recirculation eddies. Locally-forced days exhibit a wider range of plume behavior due to the combination of thermally-induced valley and slope flows, which are often flowing in different cardinal directions, and wind shear found aloft at higher altitudes and elevations. We saw evidence of smoke lofting on top of the mesas due to strong upslope flows on these days. A major finding of this experiment was the effectiveness of scanning lidars to measure 2-dimensional plume transport out to a 2–3 km distance; much farther than could be visibly observed. METEX21 was the first of three planned tracer experiments at NNSS, and future experiments will incorporate multiple tracers to improve individual plume identification so that finer resolution flow details can be attained from these measurements, as well as deploy a larger suite of meteorological instrumentation, including more temperature profiling data.

54 ENVIRONMENTAL SCIENCES↗

Global measurements of wind fields using the Laser Atmospheric Wind Sounder (LAWS) on the Earth Observing System (EOS)

The technology for measuring global wind fields in space by the Laser Atmospheric Wind Sounder (LAWS) to be flown on the Earth Observing System (EOS) is discussed. Studies initiated by NASA to determine the feasibility of using Doppler lidar from a platform in space to measure the wind globally have shown the general feasibility of the technique and have identified the technological problems that need to be resolved. Among the lidar systems being evaluated, CO2 coherent detection lidar is given special consideration. A comprehensive research program, the Global Backscatter Experiment, has been established to study global distribution of naturally occurring atmospheric aerosols that provide signal return at the wavelengths used by the techniques under consideration. Wind profiles from space will provide essential information for advancing the skill of numerical weather prediction, furthering the present knowledge of the large-scale atmospheric circulation and climate dynamics, and of global biogeochemical and hydrologic cycles.

Fitzjarrald, Daniel E.↗

Doppler radar detection of vortex hazard indicators

Wake vortex experiments were conducted at White Sands Missile Range, NM using the AN/MPS-39 Multiple Object Tracking Radar (MOTR). The purpose of these experiments was twofold. The first objective was to verify that radar returns from wake vortex are observed for some time after the passage of an aircraft. The second objective was to verify that other vortex hazard indicators such as ambient wind speed and direction could also be detected. The present study addresses the Doppler characteristics of wake vortex and clear air returns based upon measurements employing MOTR, a very sensitive C-Band phased array radar. In this regard, the experiment was conducted so that the spectral characteristics could be determined on a dwell to-dwell basis. Results are presented from measurements of the backscattered power (equivalent structure constant), radial velocity and spectral width when the aircraft flies transverse and axial to the radar beam. The statistics of the backscattered power and spectral width for each case are given. In addition, the scan strategy, experimental test procedure and radar parameters are presented.

Nespor, Jerald D.↗

Hardware, methodology and applications of 2 + D backscatter Mössbauer spectroscopy with simultaneous x-ray and γ-ray detection

Abstract A unique method is presented for the acquisition and analysis of 57 Fe backscatter Mössbauer spectra with simultaneous detection of the resonant 14.4 keV γ -rays and the characteristic 6.4 keV x-rays, using a custom-built multi-parameter analyser constructed on the basis of commercial analogue to digital converters and high-speed digital latches. The system allows for the simultaneous registration of Doppler-modulation velocities and photon energies, with up to 4096 and 8192 digital channels respectively. This arrangement is in contrast to most related systems, which detect at a single narrow energy window per detector. Samples of arbitrary atomic structure, morphology and surface topography can be studied without altering the setup or the analysis procedure, provided that the samples are at least micrometre sized. The hardware and software that are used to acquire data with minimal dead time are described and the custom and self-contained methods for post-measurement energy discrimination, background correction and velocity-axis folding are discussed. The data are fit using a general Hamiltonian model for the nuclear energy levels of 57 Fe and a quantum mechanical description of the angular momentum coupling is utilised, with consideration of the crystalline and chemical disorder of the sample under examination. Three examples of distinct magnetic systems, with thicknesses ranging from 5 μ m to 6 mm, that were studied using this method are presented, these are: an amorphous CoFeB-based ribbon with ultra-soft coercivity for high-frequency applications, magnetically hard Nd-Fe-B thick films on Si substrates, examined in both as-deposited and annealed states, and a sample from the nickel-rich iron meteorite NWA 6259 that contains the atomically ordered, elevated coercivity, L 1 0 phase of FeNi, tetrataenite. The wide applicability and usefulness of this method is thus demonstrated on three distinct sample morphologies that required little to no surface preparation prior to examination.

Engineering↗