Multitone harmonic-balance simulations of an x-ray transition-edge sensor characterized at BESSY II

We present multitone harmonic-balance (MTHB) simulations of a Ti-Au x-ray transition-edge sensor (TES) microcalorimeter in a 5x5 pixel spectrometer array. The dynamic response of the TES microcalorimeter under simulation has been extremely well characterized at the BESSY II Synchrotron Radiation Facility in Berlin. We compare our simulated results directly with these measurements, and show that the MTHB algorithm is able to simulate to great accuracy the dynamic behavior of the TES, even when saturated by 6 keV photons. In this paper, we provide a detailed account of the MTHB simulations, and discuss the impact of this work on future missions such as the International X-ray Observatory.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

FABRY-PEROT VERSUS SLIT SPECTROPOLARIMETRY OF PORES AND ACTIVE NETWORK: ANALYSIS OF IBIS AND HINODE DATA

We discuss spectropolarimetric measurements of photospheric (Fe I 630.25 nm) and chromospheric (Ca II 854.21 nm) spectral lines in and around small magnetic flux concentrations, including a pore. Our long-term goal is to diagnose properties of the magnetic field near the base of the corona. We compare ground-based two-dimensional spectropolarimetric measurem ents with (almost) simultaneous space-based slit spectropolarimetry. We address the question of noise and crosstalk in the measurements and attempt to determine the suitability of Ca II measurements with imaging spectropolarimeters for the determination of chromospheric magnetic fields. The ground-based observations were obtained 2008 May 20, with the Interferometric Bidimensional Spectrometer (IBIS) in spectropolarimetric mode operated at the Dunn Solar Telescope at Sunspot, NM. The space observations were obtained with the Spectro-Polarimeter of the Solar Optical Telescope aboard the Japanese Hinode satellite. The agreement between the near-simultaneous co-spatial IBIS and Hinode Stokes-V profiles at 630.25 nm is excellent, with V/I amplitudes compatible to within 1%. The IBIS QU measurements are affected by residual crosstalk from V, arising from calibration inaccuracies, not from any inherent limitation of imaging spectroscopy. We use a Principal Component Analysis to quantify the detected crosstalk. QU profiles with V crosstalk subtracted are in good agreement with the Hinode measurements, but are noisier owing to fewer collected photons. Chromospheric magnetic fields are notoriously difficult to constrain by polarization of Ca II lines alone. However, we demonstrate that high cadence, high angular resolution monochromatic images of fibrils in Ca II and Halpha, seen clearly in IBIS observations, can be used to improve the magnetic field constraints, under conditions of high electrical conductivity. Such work is possible only with time series data sets from two-dimensional spectroscopic instruments such as IBIS, under conditions of good seeing.

79 ASTRONOMY AND ASTROPHYSICS↗

The Tianlai dish pathfinder array: design, operation, and performance of a prototype transit radio interferometer

ABSTRACT The Tianlai Dish Pathfinder Array is a radio interferometer designed to test techniques for 21 cm intensity mapping in the post-reionization universe as a means for measuring large-scale cosmic structure. It performs drift scans of the sky at constant declination. We describe the design, calibration, noise level, and stability of this instrument based on the analysis of about 5% of 6200 h of on-sky observations through 2019 October. Beam pattern determinations using drones and the transit of bright sources are in good agreement, and compatible with electromagnetic simulations. Combining all the baselines, we make maps around bright sources and show that the array behaves as expected. A few hundred hours of observations at different declinations have been used to study the array geometry and pointing imperfections, as well as the instrument noise behaviour. We show that the system temperature is below 80 K for most feed antennas and that noise fluctuations decrease as expected with integration time, at least up to a few hundred seconds. Analysis of long integrations, from 10 nights of observations of the North Celestial Pole (NCP), yielded visibilities with amplitudes of 20–30 mK, consistent with the expected signal from the NCP radio sky with ${\lt}10\,$ mK precision for 1 MHz × 1 min binning. Hi-pass filtering the spectra to remove smooth spectrum signal yields a residual consistent with zero signal at the $0.5\,$ mK level.

(cosmology:) large-scale structure of the Universe↗

Fusion Power measurement at ITER

Nuclear fusion research aims to provide energy for the future in a sustainable way and the ITER project scope is to demonstrate the feasibility of nuclear fusion energy. ITER is a nuclear experimental reactor based on a large scale fusion plasma (tokamak type) device generating Deuterium - Tritium (DT) fusion reactions with emission of 14 MeV neutrons producing up to 700 MW fusion power. The measurement of fusion power, i.e. total neutron emissivity, will play an important role for achieving ITER goals, in particular the fusion gain factor Q related to the reactor performance. Particular attention is given also to the development of the neutron calibration strategy whose main scope is to achieve the required accuracy of 10% for the measurement of fusion power. Neutron Flux Monitors located in diagnostic ports and inside the vacuum vessel will measure ITER total neutron emissivity, expected to range from 1014 n/s in Deuterium - Deuterium (DD) plasmas up to almost 10{sup 21} n/s in DT plasmas. The neutron detection systems as well all other ITER diagnostics have to withstand high nuclear radiation and electromagnetic fields as well ultrahigh vacuum and thermal loads. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Direct visualization of electromagnetic wave dynamics by laser-free ultrafast electron microscopy

Integrating femtosecond lasers with electron microscopies has enabled direct imaging of transient structures and morphologies of materials in real time and space. Here, we report the development of a laser-free ultrafast electron microscopy (UEM) offering the same capability but without requiring femtosecond lasers and intricate instrumental modifications. We create picosecond electron pulses for probing dynamic events by chopping a continuous beam with a radio frequency (RF)–driven pulser with the pulse repetition rate tunable from 100 MHz to 12 GHz. As a first application, we studied gigahertz electromagnetic wave propagation dynamics in an interdigitated comb structure. We reveal, on nanometer space and picosecond time scales, the transient oscillating electromagnetic field around the tines of the combs with time-resolved polarization, amplitude, and local field enhancement. This study demonstrates the feasibility of laser-free UEM in real-space visualization of dynamics for many research fields, especially the electrodynamics in devices associated with information processing technology.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Tokyo Axion Helioscope

The idea of a magnetic axion helioscope was first proposed by Pierre Sikivie in 1983. Tokyo axion helioscope was built exploiting its detection principle with a dedicated cryogen-free superconducting magnet and PIN photodiodes for x-ray detectors. Solar axions, if exist, would be converted into x-ray photons in the magnetic field. Conversion is coherently enhanced even for massive axions by filling the conversion region with helium gas. Its start up, search results so far and prospects are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reflectance of polytetrafluoroethylene for xenon scintillation light

Gaseous and liquid xenon particle detectors are being used in a number of applications including dark matter search and neutrino-less double beta decay experiments. Polytetrafluoroethylene (PTFE) is often used in these detectors both as electrical insulator and as a light reflector to improve the efficiency of detection of scintillation photons. However, xenon emits in the vacuum ultraviolet (VUV) wavelength region ({lambda}{approx_equal}175 nm) where the reflecting properties of PTFE are not sufficiently known. In this work, we report on measurements of PTFE reflectance, including its angular distribution, for the xenon scintillation light. Various samples of PTFE, manufactured by different processes (extruded, expanded, skived, and pressed) have been studied. The data were interpreted with a physical model comprising both specular and diffuse reflections. The reflectance obtained for these samples ranges from about 47% to 66% for VUV light. Other fluoropolymers, namely, ethylene tetrafluoroethylene (ETFE), fluorinated ethylene propylene (FEP), and perfluoro-alkoxyalkane (PFA) were also measured.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

OPTIMIZATION OF A TWO-STAGE ADR FOR THE SOFT X-RAY SPECTROMETER (SXS) INSTRUMENT ON THE ASTRO-H MISSION

NASA/Goddard Space Flight Center has begun developing the Soft X-ray Spectrometer (SXS) instrument that will be flown on the Japanese Astro-H mission. The SXS's 36-pixel detector array will be cooled to 50 mK using a two-stage adiabatic demagnetization refrigerator (ADR). A complicating factor for its design is that the ADR will be integrated into a superfluid helium dewar at 1.3 K that will be coupled to a 1.8 K Joule-Thomson (JT) stage through a heat switch. When liquid helium is present, the coupling will be weak, and the JT stage will act primarily as a shield to reduce parasitic heat loads. When the liquid is depleted, the heat switch will couple more strongly so that the ADR can continue to operate using the JT stage as its heat sink. A two-stage ADR is the most mass efficient option and it has the operational flexibility to work well with a stored cryogen and a cryocooler. The stages are operated independently, and this opens up a very large parameter space for optimizing the design. This paper discusses the optimization process and most relevant trades considered in the design of the SXS ADR, and its expected performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

AN OBSERVATIONAL DETERMINATION OF THE PROTON TO ELECTRON MASS RATIO IN THE EARLY UNIVERSE

In an effort to resolve the discrepancy between two measurements of the fundamental constant mu, the proton to electron mass ratio, at early times in the universe we reanalyze the same data used in the earlier studies. Our analysis of the molecular hydrogen absorption lines in archival Very Large Telescope/Ultraviolet and Visible Echelle Spectrometer (UVES) spectra of the damped Lyman alpha systems in the quasi-stellar objects Q0347-383 and Q0405-443 yields a combined measurement of a DELTAmu/mu value of (-7 +- 8) x 10{sup -6}, consistent with no change in the value of mu over a time span of 11.5 Gyr. Here, we define DELTAmu as (mu {sub z} - mu{sub 0}) where mu {sub z} is the value of mu at a redshift of z and mu{sub 0} is the present-day value. Our null result is consistent with the recent measurements of King et al., DELTAmu/mu = (2.6 +- 3.0) x 10{sup -6}, and inconsistent with the positive detection of a change in mu by Reinhold et al. Both of the previous studies and this study are based on the same data but with differing analysis methods. Improvements in the wavelength calibration over the UVES pipeline calibration is a key element in both of the null results. This leads to the conclusion that the fundamental constant mu is unchanged to an accuracy of 10{sup -5} over the last 80% of the age of the universe, well into the matter dominated epoch. This limit provides constraints on models of dark energy that invoke rolling scalar fields and also limits the parameter space of supersymmetric or string theory models of physics. New instruments, both planned and under construction, will provide opportunities to greatly improve the accuracy of these measurements.

79 ASTRONOMY AND ASTROPHYSICS↗

Peculiarities of detecting pulses of runaway electrons and X-rays generated by high-voltage nanosecond discharges in open atmosphere

Peculiarities of detecting pulses of high-energy runaway electrons and the accompanying X-rays generated by high-voltage nanosecond discharges at high overvoltages in dense gases are discussed. Methods for overcoming difficulties encountered in such measurements are demonstrated. Different techniques for detecting runaway electrons and X-rays generated by discharges in open atmosphere are described, and typical errors that may be done when interpreting measurement results are considered. Experiments with the use of a small-size generator of nanosecond pulses with the idle-running voltage of 250-270 kV and stored energy of {approx}0.5 J have been carried out. It is shown that, in measuring runaway electron pulses by using an experimental configuration with a grid anode, a major portion of the recorded signal is attributed to electromagnetic disturbances. It is found that X-rays are mainly generated due to the deceleration of runaway electrons in the anode, rather than in gas. The number of runaway electrons with energies {approx}300 keV does not exceed 10{sup 9} per shot, and the X-ray dose is 60-200 {mu}R/shot, depending on the anode material.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hard x-ray response of pixellated CdZnTe detectors

In recent years, the development of cadmium zinc telluride (CdZnTe) detectors for x-ray and gamma ray spectrometry has grown rapidly. The good room temperature performance and the high spatial resolution of pixellated CdZnTe detectors make them very attractive in space-borne x-ray astronomy, mainly as focal plane detectors for the new generation of hard x-ray focusing telescopes. In this work, we investigated on the spectroscopic performance of two pixellated CdZnTe detectors coupled with a custom low noise and low power readout application specific integrated circuit (ASIC). The detectors (10x10x1 and 10x10x2 mm{sup 3} single crystals) have an anode layout based on an array of 256 pixels with a geometric pitch of 0.5 mm. The ASIC, fabricated in 0.8 mum BiCMOS technology, is equipped with eight independent channels (preamplifier and shaper) and characterized by low power consumption (0.5 mW/channel) and low noise (150-500 electrons rms). The spectroscopic results point out the good energy resolution of both detectors at room temperature [5.8% full width at half maximum (FWHM) at 59.5 keV for the 1 mm thick detector; 5.5% FWHM at 59.5 keV for the 2 mm thick detector) and low tailing in the measured spectra, confirming the single charge carrier sensing properties of the CdZnTe detectors equipped with a pixellated anode layout. Temperature measurements show optimum performance of the system (detector and electronics) at T=10 deg.C and performance degradation at lower temperatures. The detectors and the ASIC were developed by our collaboration as two small focal plane detector prototypes for hard x-ray multilayer telescopes operating in the 20-70 keV energy range.

36 MATERIALS SCIENCE↗

SQUID-Based Microwave Cavity Search for Dark-Matter Axions

Axions in the mueV mass range are a plausible cold dark-matter candidate and may be detected by their conversion into microwave photons in a resonant cavity immersed in a static magnetic field. We report the first result from such an axion search using a superconducting first-stage amplifier (SQUID) replacing a conventional GaAs field-effect transistor amplifier. This experiment excludes KSVZ dark-matter axions with masses between 3.3 mueV and 3.53 mueV and sets the stage for a definitive axion search utilizing near quantum-limited SQUID amplifiers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Precise Measurement of the Absolute Fluorescence Yield

We present preliminary results of the absolute yield of fluorescence emission in atmospheric gases. Measurements were performed at the Fermilab Test Beam Facility with a variety of beam particles and gases. Absolute calibration of the fluorescence yield to 5% level was achieved by comparison with two known light sources - the Cherenkov light emitted by the beam particles, and a calibrated nitrogen laser. The uncertainty of the energy scale of current Ultra-High Energy Cosmic Rays experiments will be significantly improved by the AIRFLY measurement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Position sensitive detection of neutrons in high radiation background field

We present the development of a high-resolution position sensitive device for detection of slow neutrons in the environment of extremely high γ and e{sup −} radiation background. We make use of a planar silicon pixelated (pixel size: 55 × 55 μm{sup 2}) spectroscopic Timepix detector adapted for neutron detection utilizing very thin {sup 10}B converter placed onto detector surface. We demonstrate that electromagnetic radiation background can be discriminated from the neutron signal utilizing the fact that each particle type produces characteristic ionization tracks in the pixelated detector. Particular tracks can be distinguished by their 2D shape (in the detector plane) and spectroscopic response using single event analysis. A Cd sheet served as thermal neutron stopper as well as intensive source of gamma rays and energetic electrons. Highly efficient discrimination was successful even at very low neutron to electromagnetic background ratio about 10{sup −4}.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The NO$v$A Test Beam Program

NO$\nu$A is a long-baseline off-axis beam neutrino experiment. By measuring $\nu_\mu$ disappearance and $\nu_e$ appearance at the 14 kiloton NO$\nu$A Far Detector, the experiment is addressing outstanding questions in neutrino physics, including the neutrino mass hierarchy and existence of leptonic CP violation. The NO$\nu$A Test Beam program, under deployment at the Fermilab Test Beam Facility, will use a scaled-down NO$\nu$A detector to sample beams of tagged electrons, muons, pions, and protons in the momentum range of 0.3 to 2 GeV/c. It will further the NO$\nu$A physics reach by precisely measuring the detector's muon energy scale and electromagnetic and hadronic response, and provide real data for detailed studies of particle identification techniques. Ongoing efforts on beam-line instrumentation, data acquisition, simulation, momentum reconstruction and particle identification are presented. Implications for the neutrino oscillation measurements are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Dark Siren Measurement of the Hubble Constant with the LIGO/Virgo Gravitational Wave Event GW190412 and DESI Galaxies

Abstract We present a measurement of the Hubble Constant H 0 using the gravitational wave event GW190412, an asymmetric binary black hole merger detected by LIGO/Virgo, as a dark standard siren. This event does not have an electromagnetic counterpart, so we use the statistical standard siren method and marginalize over potential host galaxies from the Dark Energy Spectroscopic Instrument (DESI) survey. GW190412 is well-localized to 12 deg 2 (90% credible interval), so it is promising for a dark siren analysis. The dark siren value for H 0 = 85.4 − 33.9 + 29.1 km s −1 Mpc −1 , with a posterior shape that is consistent with redshift overdensities. When combined with the bright standard siren measurement from GW170817 we recover H 0 = 77.96 − 5.03 + 23.0 km s −1 Mpc −1 , consistent with both early and late-time Universe measurements of H 0 . This work represents the first standard siren analysis performed with DESI data, and includes the most complete spectroscopic sample used in a dark siren analysis to date.

Ballard, W.↗

Coherent hybrid electromagnetic field imaging

An apparatus and corresponding method for coherent hybrid electromagnetic field imaging of a target, where an energy source is used to generate a propagating electromagnetic beam, an electromagnetic beam splitting means to split the beam into two or more coherently matched beams of about equal amplitude, and where the spatial and temporal self-coherence between each two or more coherently matched beams is preserved. Two or more differential modulation means are employed to modulate each two or more coherently matched beams with a time-varying polarization, frequency, phase, and amplitude signal. An electromagnetic beam combining means is used to coherently combine said two or more coherently matched beams into a coherent electromagnetic beam. One or more electromagnetic beam controlling means are used for collimating, guiding, or focusing the coherent electromagnetic beam. One or more apertures are used for transmitting and receiving the coherent electromagnetic beam to and from the target. A receiver is used that is capable of square-law detection of the coherent electromagnetic beam. A waveform generator is used that is capable of generation and control of time-varying polarization, frequency, phase, or amplitude modulation waveforms and sequences. A means of synchronizing time varying waveform is used between the energy source and the receiver. Finally, a means of displaying the images created by the interaction of the coherent electromagnetic beam with target is employed.

47 OTHER INSTRUMENTATION↗

Purpose, Design, and Analysis of the NSTX-U Centerstack Casing Lateral Support Shims

The National Spherical Torus Experiment Upgrade (NSTX-U) centerstack casing surrounds the central magnet core of NSTXU. It provides the inner vacuum boundary of the plasma chamber and supports the radially inboard plasma facing components lining the plasma chamber. The casing is supported like a cantilever, fixed at the lower flange by a connection to the TF Bundle through a G-10 ring. It is flexibly supported at the top by bellows, and insulated shims intended to react the largest part of the inventory of the disruption loads at the upper support, thereby protecting the upper and lower connections from excessive loads. A large part of the qualification of the casing and tiles requires addressing and quantifying disruption loads. These have been estimated based on extensions of the behavior of NSTX during its run period roughly 15 years ago. Structural qualification of the Upgrade used these estimates of the loading as input to calculations to demonstrate adequacy for a “most probable” disruption. The estimates are included in a requirements document to guide conservative design of all components loaded by disruptions. However, the changes made for the upgrade made the extrapolation of disruption behavior uncertain. Disruptions include axisymmetric loading from axisymmetric currents induced in the vessel shells. In addition, more complex currents called Halo currents are a result of plasma poloidal currents impinging on the casing. The halo currents add another layer of uncertain behavior and net lateral loading to the casing. As a result, NSTX-U is equipped with a number of instruments intended to assess the nature and severity of disruptions. The casing shims are required for lateral support of the casing, but these have also been converted to load cells to provide another measure of the magnitude of symmetric and asymmetric loading. Some of the logic in the development of the requirements document are presented. Electromagnetic analysis of axisymmetric and halo loading is described. Global simulations of the casing transient dynamic response, and local analysis and testing of the shim/load cell are included. The shim load cells and other instrumentation will be an important guide in planning NSTX-U experiments beyond its next run period expected in late 2026 or early 2027.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗