Search NASA⌕ Search

SEARCH · Search NASA

Results for “ELECTRONIC GUIDANCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

High-Fidelity 3D-Nanoprinting via Focused Electron Beams: Growth Fundamentals

While 3D-printing is currently experiencing significant growth and having a significant impact on science and technology, the expansion into the nanoworld is still a highly challenging task. Among the increasing number of approaches, focused electron-beam-induced deposition (FEBID) was recently demonstrated to be a viable candidate toward a generic direct-write fabrication technology with spatial nanometer accuracy for complex shaped 3D-nanoarchitectures. In this comprehensive study, we explore the parameter space for 3D-FEBID and investigate the implications of individual and interdependent parameters on freestanding nanosegments, which act as a fundamental building block for complex 3D-structures. In particular, the study provides new basic insights such as precursor transport limitations and angle dependent growth rates, both essential for high-fidelity fabrication. In conclusion, complemented by practical aspects, we provide both basic insights in 3D-growth dynamics and technical guidance for specific process adaption to enable predictable and reliable direct-write synthesis of freestanding 3D-nanoarchitectures.

3D-nanoprinting↗

Infant burn injuries related to water heating for powdered infant formula preparation

Guidance for preparing powdered infant formula (PIF) helps to ensure it meets the nutritional needs of infants and is safe to consume. Among safety concerns is Cronobacter sakazakii contamination which can lead to serious infections and death. PIF preparation guidance varies; there is a lack of consensus on whether there is a need to boil water to inactivate potential Cronobacter and for how long to let the water cool before reconstitution. We sought to quantify the burden of burn injuries among infants related to water heating for PIF preparation. Estimating this burden may help inform preparation recommendations. Burn injuries among infants <18 months of age were identified from 2017 to 2019 National Electronic Injury Surveillance System data collected from sampled hospital emergency departments. Injuries were classified as related to PIF water heating, potentially related to PIF water heating but with undetermined causation, related to other infant feeding aspects, or unrelated to infant formula or breast milk feeding. Unweighted case counts for each injury classification were determined. Across sampled emergency departments, 7 PIF water heating injuries were seen among the 44,395 injuries reported for infants <18 months. No reported PIF water heating injuries were fatal, but 3 required hospitalization. Another 238 injuries potentially related to PIF water heating but with undetermined causation were also seen. Preparation guidance should consider both the potential risk for Cronobacter infection and the potential risk for burns.

60 APPLIED LIFE SCIENCES↗

Spectral Addressability in a Modular Two Qubit System

The combination of structural precision and reproducibility of synthetic chemistry is perfectly suited for the creation of chemical qubits, the core units of a quantum information science (QIS) system. By exploiting the atomistic control inherent to synthetic chemistry, we address a fundamental question of how the spin–spin distance between two qubits impacts electronic spin coherence. To achieve this goal, in this study we designed a series of molecules featuring two spectrally distinct qubits, an early transition metal, Ti 3+ , and a late transition metal, Cu 2+ with increasing separation between the two metals. The spectral separation between the two metals enables us to probe each metal individually in the bimetallic species and compare it with monometallic control samples. Coherence times found to be governed by the distance to nuclear spins on the other qubit’s ligand framework. This finding offers guidance for the design of spectrally addressable molecular qubits.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Comparison of In-Room Computerized Tomography Options for Detection of Fiducial Markers in Prostate Cancer Radiotherapy

Purpose: To compare volumetric in-room computed tomography (CT) and kilovoltage (kV) cone-beam CT (CBCT) to planar imaging with respect to their ability to localize fiducial markers (FMs) for radiotherapy of prostate cancer. Methods and Materials: Image guidance options from two linear accelerators were compared in terms of identifying the center of gravity (COG) of FMs from the isocenter: a Siemens Primatom, where the couch is rotated 180 degrees from the treatment isocenter to the in-room CT vs. electronic portal imaging (EPI); and a Varian OBI system, where kV CBCT, EPI, and planar kV radiographs were compared. In all, 387 image pairs (CBCT = 133; CT = 254) from 18 patients were analyzed. A clinical tolerance of 3 mm was predefined as the acceptable threshold for agreement. Results: COG location on in-room CT and EPI was in agreement 96.9%, 85.8%, and 89.0% of the time in the left-right (LR), superior-inferior (SI), and anterior-posterior (AP) directions, respectively, vs. 99.2%, 91.7%, and 93.2% for the CBCT and EPI analysis. The CBCT vs. kV radiographs were in agreement 100% (LR), 85.4% (SI), and 88.5% (AP), and EPI vs. kV radiographs were in agreement 100% (LR), 94.6% (SI), and 91.5% (AP) of the time. Conclusion: Identification of FMs on volumetric or planar images was found to be not equivalent ({+-}3 mm) using either linear accelerator. Intrafraction prostate motion, interpretation of FM location, and spatial properties of images are contributing factors. Although in-room CT has superior image quality, the process of realigning the treatment couch to acquire a CT introduces an error, highlighting the benefits of a single isocentric system.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Electromagnetic Transient Modeling of Large Data Centers for Grid-Level Studies: Beta Release

The magnitude and complexity of electricity usage patterns from large data centers are having significant impacts on the operation and dynamics of the power grid; grid operators and planners require a range of specialized data center models to properly evaluate these impacts and specify technical solutions as needed. Towards addressing this need, Pacific Northwest National Laboratory (PNNL) has developed a library of electromagnetic transient (EMT) models for grid-level studies of data centers called the data center model library (DML). This report describes how the DML was created and how it may properly be used. This report details the DML’s beta release, completed in July 2026. This is a revision and expansion of the alpha release, which was made available in January 2026 The models present in the DML are generic models; subject matter expertise and additional technical data are needed to modify these models before they can represent any real data center. However, they will significantly reduce the level of effort required to develop site-specific models and can serve as a common starting point to guide industry towards a more refined consensus. Most of the models within DML are dedicated to representing the power electronics interfaces commonly used in modern data centers, such as double-conversion uninterruptible power supplies and single-phase power factor correction converters. These models are intended for use in grid-level studies and are a simplified aggregation of many small components. That said, background material on the physical and electrical design of large data centers is provided as companion material so that users can be aware of many of the details which have been omitted or streamlined as a matter of practical necessity. Additionally, guidance on the application of EMT analysis for data center interconnection studies is provided, which aids users in identifying when the DML is necessary and what sort of additional model development may be necessary for conducting real-world studies.

electromagnetic transients↗

In-situ TEM study of Kr ion irradiation tolerance of SiFeOC nanocomposite

Here, in this work, ion irradiation of polymer derived SiFeOC nanocomposite was carried out using 1.2 MeV Kr ions at room temperature and 600°C. The starting composite was composed of Fe 3 Si, SiC, SiOC, SiO 2 , and graphitic C. In-situ TEM investigations show uniform distribution of nano-crystalline Fe 3 Si and SiC phases in the amorphous SiOC matrix. During ion irradiation, the SiOC bulk microstructure and interfaces between Fe 3 Si or SiC crystallites and the SiOC matrix remain defect-free and demonstrate outstanding ion irradiation resistance. At room temperature, the crystalline domains are stable up to 2 dpa. At 600°C, Fe 3 Si crystallites are more stable than SiC; SiC crystallites are stable up to 4 dpa while the Fe 3 Si crystallites are stable up to 10 dpa. These crystallites also coalescence and amorphize simultaneously during ion irradiation. The exceptional tolerance to defect formation and irradiation of the SiFeOC nanocomposite provides important guidance to developing irradiation resistant fuels for advanced gas cooled reactors.

36 MATERIALS SCIENCE↗

SU-G-BRA-01: A Real-Time Tumor Localization and Guidance Platform for Radiotherapy Using US and MRI

Purpose: To develop and validate a real-time motion management platform for radiotherapy that directly tracks tumor motion using ultrasound and MRI. This will be a cost-effective and non-invasive real-time platform combining the excellent temporal resolution of ultrasound with the excellent soft-tissue contrast of MRI. Methods: A 4D planar ultrasound acquisition during the treatment that is coupled to a pre-treatment calibration training image set consisting of a simultaneous 4D ultrasound and 4D MRI acquisition. The image sets will be rapidly matched using advanced image and signal processing algorithms, allowing the display of virtual MR images of the tumor/organ motion in real-time from an ultrasound acquisition. Results: The completion of this work will result in several innovations including: a (2D) patch-like, MR and LINAC compatible 4D planar ultrasound transducer that is electronically steerable for hands-free operation to provide real-time virtual MR and ultrasound imaging for motion management during radiation therapy; a multi- modal tumor localization strategy that uses ultrasound and MRI; and fast and accurate image processing algorithms that provide real-time information about the motion and location of tumor or related soft-tissue structures within the patient. Conclusion: If successful, the proposed approach will provide real-time guidance for radiation therapy without degrading image or treatment plan quality. The approach would be equally suitable for image-guided proton beam or heavy ion-beam therapy. This work is partially funded by NIH grant R01CA190298.

60 APPLIED LIFE SCIENCES↗

A charge-density-based general cation insertion algorithm for generating new Li-ion cathode materials

Future lithium (Li) energy storage technologies, in particular solid-state configurations with a Li metal anode, opens up the possibility of using cathode materials that do not necessarily contain Li in its as-made state. To accelerate the discovery and design of such materials, we develop a general, chemically, and structurally agnostic methodology for identifying the optimal Li sites in any crystalline material. For a given crystal structure, we attempt multiple Li insertions at symmetrically in-equivalent positions by analyzing the electronic charge density obtained from first-principles density functional theory. In this report, we demonstrate the effectiveness of this procedure in successfully identifying the positions of the Li ion in well-known cathode materials using only the empty host (charged) material as guidance. Furthermore, applying the algorithm to over 2000 candidate cathode empty host materials we obtain statistics of Li site preferences to guide future developments of novel Li-ion cathode materials, particularly for solid-state applications.

25 ENERGY STORAGE↗

Beam-Riding Analysis of a Parabolic Laser-thermal Thruster

Flight experiments with laser-propelled vehicles (lightcrafts) are often performed by wire-guidance or with spin-stabilization. Nevertheless, the specific geometry of the lightcraft's optics and nozzle may provide for inherent beam-riding properties. These features are experimentally investigated in a hovering experiment at a small free flight test range with an electron-beam sustained pulsed CO{sub 2} high energy laser. Laser bursts are adapted with a real-time control to lightcraft mass and impulse coupling for ascent and hovering in a quasi equilibrium of forces. The flight dynamics is analyzed with respect to the impulse coupling field vs. attitude, given by the lightcraft's offset and its inclination angle against the beam propagation axis, which are derived from the 3D-reconstruction of the flight trajectory from highspeed recordings. The limitations of the experimental parameters' reproducibility and its impact on flight stability are explored in terms of Julia sets. Solution statements for dynamic stabilization loops are presented and discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Automating the CMS DAQ

We present the automation mechanisms that have been added to the Data Acquisition and Run Control systems of the Compact Muon Solenoid (CMS) experiment during Run 1 of the LHC, ranging from the automation of routine tasks to automatic error recovery and context-sensitive guidance to the operator. These mechanisms helped CMS to maintain a data taking efficiency above 90% and to even improve it to 95% towards the end of Run 1, despite an increase in the occurrence of single-event upsets in sub-detector electronics at high LHC luminosity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sliding seal materials for adiabatic engines

The sliding friction coefficients and wear rates of promising carbide, oxide, and nitride materials were measured under temperature, environmental, velocity, loading conditions that are representative of the adiabatic engine environment. In order to provide guidance needed to improve materials for this application, the program stressed fundamental understanding of the mechanisms involved in friction and wear. Microhardness tests were performed on the candidate materials at elevated temperatures, and in atmospheres relevant to the piston seal application, and optical and electron microscopy were used to elucidate the micromechanisms of wear following wear testing. X-ray spectroscopy was used to evaluate interface/environment interactions which seemed to be important in the friction and wear process. Electrical effects in the friction and wear processes were explored in order to evaluate the potential usefulness of such effects in modifying the friction and wear rates in service. However, this factor was found to be of negligible significance in controlling friction and wear.

Lankford, J.↗

Considerations for a Proton Single Event Effects (SEE) Guideline

The intent of this document is to provide guidance on when and what type of SEE tests should be performed on a device under test (DUT) based on orbit, technology, existing data, and application. It is NOT intended to provide a detailed guideline for how to perform proton SEE radiation tests on electronics.

LaBel, Kenneth A.↗

FIM Avionics Operations Manual

This document describes the operation and use of the Flight Interval Management (FIM) Application installed on an electronic flight bag (EFB). Specifically, this document includes: 1) screen layouts for each page of the interface; 2) step-by-step instructions for data entry, data verification, and input error correction; 3) algorithm state messages and error condition alerting messages; 4) aircraft speed guidance and deviation indications; and 5) graphical display of the spatial relationships between the Ownship aircraft and the Target aircraft.

Alves, Erin E.↗

Considerations for a Proton Single Event Effects (SEE) Guideline

The intent of this document is to provide guidance on when and what type of -SEE tests should be performed on a device under test (OUT) based on orbit, technology, existing data, and application. It is NOT intended to provide a detailed guideline for how to perform proton SEE radiation tests on electronics.

LaBel, Kenneth A.↗

U.S. EPA Superfund Counts Per Minute (CPM) Electronic Calculator - 17305

The U.S. Environmental Protection Agency (EPA) Superfund program is developing a new Counts Per Minute (CPM) calculator to correlate real-time survey results, which are often expressed as counts per minute, to contaminant concentrations that are more typically provided in risk assessments or for cleanup levels, usually expressed in pCi/g or pCi/m{sup 2}. Currently there is no EPA guidance for Superfund sites on correlating count per minute field survey readings back to risk, dose, or other Applicable or Relevant and Appropriate Requirements (ARAR) based concentrations. The CPM calculator is a web-based model that estimates a gamma detector response for a given level of contamination. The intent of the CPM calculator is to facilitate more real-time measurements within a Superfund response framework. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Effects of Functional Groups in Redox-Active Organic Molecules: A High-Throughput Screening Approach

Nonaqueous redox flow batteries have attracted recent attention with their potential for high electrochemical storage capacity, with organic electrolytes serving as solvents with a wide electrochemical stability window. Organic molecules can also serve as electroactive species, where molecules with low reduction potentials or high oxidation potentials can provide substantial chemical energy. To identify promising electrolytes in a vast chemical space, high-throughput screening (HTS) of candidate molecules plays an important role, where HTS is used to calculate properties of thousands of molecules and identify a few organic molecules worthy of further attention in battery research. Here, in this work, we present reduction and oxidation potentials obtained from HTS of 4178 molecules. The molecules are composed of base groups of five- or six-membered rings with one or two functional groups attached, with the set of possible functional groups including both electron-withdrawing and electron-donating groups. In addition to observing the trends in potentials that result from differences in organic base groups and functional groups, we analyze the effects of molecular characteristics such as multiple bonds, Hammett parameters, and functional group position. In conclusion, this work provides useful guidance in determining how the identities of the base groups and functional groups are correlated with desirable reduction and oxidation potentials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

EXACTRAC x-ray and beam isocenters--What's the difference?

Purpose: To evaluate the geometric accuracy of the isocenter of an image-guidance system, as implemented in the exactrac system from brainlab, relative to the linear accelerator radiation isocenter. Subsequently to correct the x-ray isocenter of the exactrac system for any geometric discrepancies between the two isocenters. Methods: Five Varian linear accelerators all equipped with electronic imaging devices and exactrac with robotics from brainlab were evaluated. A commercially available Winston-Lutz phantom and an in-house made adjustable base were used in the setup. The electronic portal imaging device of the linear accelerators was used to acquire MV-images at various gantry angles. Stereoscopic pairs of x-ray images were acquired using the exactrac system. The deviation between the position of the external laser isocenter and the exactrac isocenter was evaluated using the commercial software of the exactrac system. In-house produced software was used to analyze the MV-images and evaluate the deviation between the external laser isocenter and the radiation isocenter of the linear accelerator. Subsequently, the deviation between the radiation isocenter and the isocenter of the exactrac system was calculated. A new method of calibrating the isocenter of the exactrac system was applied to reduce the deviations between the radiation isocenter and the exactrac isocenter. Results: To evaluate the geometric accuracy a 3D deviation vector was calculated for each relative isocenter position. The 3D deviation between the external laser isocenter and the isocenter of the exactrac system varied from 0.21 to 0.42 mm. The 3D deviation between the external laser isocenter and the linac radiation isocenter ranged from 0.37 to 0.83 mm. The 3D deviation between the radiation isocenter and the isocenter of the exactrac system ranged from 0.31 to 1.07 mm. Using the new method of calibrating the exactrac isocenter the 3D deviation of one linac was reduced from 0.90 to 0.23 mm. The results were complicated due to routine maintenance of the linac, including laser calibration. It was necessary to repeat the measurements in order to perform the calibration of the exactrac isocenter. Conclusions: The deviations between the linac radiation isocenter and the exactrac isocenter were of an order that may have clinical relevance. An alternative method of calibrating the isocenter of the exactrac system was applied and reduced the deviations between the two isocenters.

62 RADIOLOGY AND NUCLEAR MEDICINE↗