Search NASA⌕ Search

SEARCH · Search NASA

Results for “Electric Power”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

A study of electric power transmission lines for use on the lunar surface

Analytical models have been developed to study the operating characteristics of electrical transmission lines for use on the lunar surface. Important design considerations for a transmission line operating on the lunar surface are mass, temperature, and efficiency. Transmission line parameters which impact these considerations include voltage, power loss, and waveform. The electrical and thermal models developed are used to calculate transmission line mass, size, and temperature as a function of voltage, geometry, waveform, location, and efficiency. The analyses include ac and dc for above and below ground operation. Geometries studied include a vacuum-insulated, two-wire transmission line and a solid-dielectric insulated, coaxial transmission line. A brief discussion of design considerations and the models developed is followed by results for parameter studies for both dc and ac transmission lines.

Gordon, Lloyd B.↗

Converter provides constant electrical power at various output voltages

Power converter, using an inverted flyback technique, transfers electrical energy at a constant rate from a solar cell source to a number of individual batteries, which are to be charged one at a time. The converter inverts the polarity of the solar cell source and provides the correct charging voltage.

Paulkovich, J.↗

Manufacturing cost analysis of a parabolic dish concentrator (General Electric design) for solar thermal electric power systems in selected production volumes

The manufacturing cost of a General Electric 12 meter diameter concentrator was estimated. This parabolic dish concentrator for solar thermal system was costed in annual production volumes of 100 - 1,000 - 5,000 - 10,000 - 50,000 100,000 - 400,000 and 1,000,000 units. Presented for each volume are the costs of direct labor, material, burden, tooling, capital equipment and buildings. Also presented is the direct labor personnel and factory space requirements. All costs are based on early 1981 economics.

Source record↗

Solar thermal electric power plants - Their performance characteristics and total social costs

The central receiver (power tower) concept as a thermal conversion approach to the conversion of solar energy into electricity is compared to other solar power plant designs which feature distributed solar collection and use other types of solar collector configurations. A variety of solar thermal storage concepts are discussed and their impacts on system performance are assessed. Although a good deal of quantification is possible in a comparative study, the subjective judgments carry enormous weight in a socio-economic decision, the ultimate choice of central power plant being more a social than an economic or technical decision. Major elements of the total social cost of each type of central plant are identified as utility economic costs, R&D funds, health costs, and other relevant social impacts.

Caputo, R. S.↗

A solar thermal electric power plant for small communities

A solar power plant has been designed with a rating of 1000-kW electric and a 0.4 annual capacity factor. It was configured as a prototype for plants in the 1000 to 10,000-kWe size range for application to small communities or industrial users either grid-connected or isolated from a utility grid. A small central receiver was selected for solar energy collection after being compared with alternative distributed collectors. Further trade studies resulted in the selection of Hitec (heat transfer salt composed of 53 percent KNO3, 40 percent NaNO2, 7 percent NaNO3) as both the receiver coolant and the sensible heat thermal stroage medium and the steam Rankine cycle for power conversion. The plant is configured with road-transportable units to accommodate remote sites and minimize site assembly requirements. Results of the analyses indicate that busbar energy costs are competitive with diesel-electric plants in certain situations, e.g., off-grid, remote regions with high insolation. Sensitivity of energy costs to plant power rating and system capacity factor are given.

Holl, R. J.↗

A 15 kWe (nominal) solar thermal-electric power conversion concept definition study: Steam Rankin reciprocator system

A conceptual design of a 3600 rpm reciprocation expander was developed for maximum thermal input power of 80 kW. The conceptual design covered two engine configurations; a single cylinder design for simple cycle operation and a two cylinder design for reheat cycle operation. The reheat expander contains a high pressure cylinder and a low pressure cylinder with steam being reheated to the initial inlet temperature after expansion in the high pressure cylinder. Power generation is accomplished with a three-phase induction motor coupled directly to the expander and connected electrically to the public utility power grid. The expander, generator, water pump and control system weigh 297 kg and are dish mounted. The steam condenser, water tank and accessory pumps are ground based. Maximum heat engine efficiency is 33 percent: maximum power conversion efficiency is 30 percent. Total cost is $3,307 or $138 per kW of maximum output power.

Wingenback, W.↗

A comparative assessment of solar thermal electric power plants in the 1-10 MWe range

The candidate power system technologies were ranked in terms of the cost of electric energy each system produces. In all cases, it was assumed that development programs would result in mature power plant systems that could be commercially manufactured. The results of the study, a brief description of the systems examined, and the methodologies used are presented.

Rosenberg, L. S.↗

Electric power - Photovoltaic or solar dynamic?

The design of the power system for supplying the Space Station with insolation-generated electricity is the main Phase B task at NASA-Lewis Center. The advantages and limitations of two types of power systems, the photovoltaic arrays (PV) and the solar dynamic system (SD), are discussed from the points of view of cost, overall systems integration, and growth. Subsystems of each of these options are described, and a sketch of a projected SD system is shown. The PV technology is well developed and proven, but its low efficiency calls for solar arrays of large areas, which affect station dynamics, control, and drag compensation. The SD systems would be less costly to operate than VP, and are more efficient, needing less deployed area. The major drawback of the SD is its infancy. The conservative and forgiving designs for some of its components must still be created and tested, and the development risks assessed.

Thomas, R. L.↗

Nuclear electric power for multimegawatt orbit transfer vehicles

Multimegawatt nuclear propulsion is an attractive option for orbit transfer vehicles. The masses of these platforms are expected to exceed the capability of a single launch from Earth necessitating assembly in space in a parking orbit. The OTV would transfer the platform from the parking orbit to the operational orbit and then return for the next mission. Electric propulsion is advantageous because of the high specific impulse achieved by the technology, 1000 to 5000 s and beyond, to reduce the propellant required. Nuclear power is attractive as the power system because of the weight savings over solar systems in the multimegawatt regime, and multimegawatts of power are required. A conceptual diagram is shown of an OTV with a command control module using electric thrusters powered from an SP-100 class nuclear reactor power system.

Casagrande, R. D.↗

Application of expert systems in the Common Module electrical power system

Each Common Module (CM) of the Space Station must be capable of handling a 50 kW electricity supply, 25 kW for transmission and 25 kW for consumption. The power must be handled and managed by on-board systems, a necessity that dovetails with the objectives of Public Law 98-371, which mandates that the Space Station push the state of the art of automation and AI. Expert systems will be needed to handle the large data flow for the power system and to ensure that the system degrades gracefully. Features of the first expert systems expected for the power system, i.e., a dynamic load planner/scheduler and energy storage subsystem management, fault diagnosis/analysis, health status/trend analysis, and orbital replacement advisor expert systems, are described. Finally, growth Space Station expert systems applications are discussed.

Weeks, D. J.↗

Concepts for central solar electric power generation

The investigation reported was conducted to select the best conceptual design of a power plant for the dynamic conversion of solar heat to electricity. Conversion of thermal energy to electricity was to be an accomplished with conventional turbomachinery. Questions of site selection are discussed along with solar energy collection systems, aspects of candidate system definition, and reference systems.

Kintigh, J. K.↗

Satellite control of electric power distribution

An L-band frequencies satellite link providing the medium for direct control of electrical loads at individual customer sites from remote central locations is described. All loads supplied under interruptible-service contracts are likely condidates for such control, and they can be cycled or switched off to reduce system loads. For every kW of load eliminated or deferred to off-peak hours, the power company reduces its need for additional generating capacity. In addition, the satellite could switch meter registers so that their readings automatically reflected the time of consumption. The system would perform load-shedding operations during emergencies, disconnecting large blocks of load according to predetermined priorities. Among the distribution operations conducted by the satellite in real time would be: load reconfiguration, voltage regulation, fault isolation, and capacitor and feeder load control.

Bergen, L.↗

Utilizing Electrical Power Extraction for Stability Bleed Reduction within Gas Turbine Engines

This paper studies the role of power extraction in gas turbine stability and how an engine may be designed to utilize this extraction to replace engine stability bleed requirements with electrical system requirements. The considered engine architecture contains two engine spools and a power turbine spool. In the baseline, low-pressure compressor stall margin is maintained by bleed air from the back of the low-pressure compressor, which is then dumped to the bypass. Power extraction from the high-pressure and low-pressure shafts are then utilized as a replacement for this bleed. This study considers component performance, sizing, efficiency, and operability, but does not consider weight or cost. Analysis within this paper is general and the concepts could be applied to other dual spool engine types, including a turbofan. Results show it is possible to completely remove the stability bleed between the low pressure and high-pressure compressor by utilizing a 35% power extraction from the high-pressure shaft or a 1.5% power extraction from the low-pressure turbine.

Gas Turbine↗

Utilizing Electrical Power Extraction for Stability Bleed Reduction within Gas Turbine Engines

This paper studies the role of power extraction in gas turbine stability and how an engine may be designed to utilize this extraction to replace engine stability bleed requirements with electrical system requirements. The considered engine architecture contains two engine spools and a power turbine spool. In the baseline, low-pressure compressor stall margin is maintained by bleed air from the back of the low-pressure compressor, which is then dumped to the bypass. Power extraction from the high-pressure and low-pressure shafts are then utilized as a replacement for this bleed. This study considers component performance, sizing, efficiency, and operability, but does not consider weight or cost. Analysis within this paper is general and the concepts could be applied to other dual spool engine types, including a turbofan. Results show it is possible to completely remove the stability bleed between the low pressure and high-pressure compressor by utilizing a 35% power extraction from the high-pressure shaft or a 1.5% power extraction from the low-pressure turbine.

Gas Turbine↗

High Power Electric Propulsion for Outer Planet Missions

Focused technology trade studies for Nuclear Electric Propulsion vehicle concepts for outer planet missions are presented; representative mission, vehicle and technology characterizations illustrate samples of work done under the NASA Marshall Space Flight Center-Boeing-SAIC In-Space Technology Assessment (ISTA) contract. An objective of ISTA is to identify and present sound technical and programtic options for the formulation and implementation of advanced electric and chemical propulsion solar system exploration missions. Investigations to date include a variety of outer planet destinations, trip times, science payload allotments, orbital capture techniques, all conducted to illustrate how advanced technology would maximize mission benefits. Architecture wide optimizations that facilitate good propulsion technology investments for advanced electric and chemical propulsion systems were conducted, including those relevant to the nuclear system initiative. Representative analyses of vehicles utilizing fission reactors with advanced power generation, Conversion, processing and electric propulsion systems, which would enable scientifically rich robotic exploration missions, are presented.

Donahue, Benjamin B.↗

The performance of solar thermal electric power systems employing small heat engines

The paper presents a comparative analysis of small (10 to 100 KWe) heat engines for use with a solar thermal electric system employing the point-focusing, distributed receiver (PF-DR) concept. Stirling, Brayton, and Rankine cycle engines are evaluated for a nominal overall system power level of 1 MWe, although the concept is applicable to power levels up to at least 10 MWe. Multiple concentrators are electrically connected to achieve the desired plant output. Best performance is achieved with the Stirling engine, resulting in a system Levelized Busbar Energy Cost of just under 50 mills/kWH and a Capital Cost of $900/kW, based on the use of mass-produced components. Brayton and Rankine engines show somewhat less performance but are viable alternatives with particular benefits for special applications. All three engines show excellent performance for the small community application.

Pons, R. L.↗