Search NASA⌕ Search

SEARCH · Search NASA

Results for “Electric power”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Testing of the Engineering Model Electrical Power Control Unit for the Fluids and Combustion Facility

The John H. Glenn Research Center at Lewis Field (GRC) in Cleveland, OH and the Sundstrand Corporation in Rockford, IL have designed and developed an Engineering Model (EM) Electrical Power Control Unit (EPCU) for the Fluids Combustion Facility, (FCF) experiments to be flown on the International Space Station (ISS). The EPCU will be used as the power interface to the ISS power distribution system for the FCF's space experiments'test and telemetry hardware. Furthermore. it is proposed to be the common power interface for all experiments. The EPCU is a three kilowatt 12OVdc-to-28Vdc converter utilizing three independent Power Converter Units (PCUs), each rated at 1kWe (36Adc @ 28Vdc) which are paralleled and synchronized. Each converter may be fed from one of two ISS power channels. The 28Vdc loads are connected to the EPCU output via 48 solid-state and current-limiting switches, rated at 4Adc each. These switches may be paralleled to supply any given load up to the 108Adc normal operational limit of the paralleled converters. The EPCU was designed in this manner to maximize allocated-power utilization. to shed loads autonomously, to provide fault tolerance. and to provide a flexible power converter and control module to meet various ISS load demands. Tests of the EPCU in the Power Systems Facility testbed at GRC reveal that the overall converted-power efficiency, is approximately 89% with a nominal-input voltage of 12OVdc and a total load in the range of 4O% to 110% rated 28Vdc load. (The PCUs alone have an efficiency of approximately 94.5%). Furthermore, the EM unit passed all flight-qualification level (and beyond) vibration tests, passed ISS EMI (conducted, radiated. and susceptibility) requirements. successfully operated for extended periods in a thermal/vacuum chamber, was integrated with a proto-flight experiment and passed all stability and functional requirements.

Kimnach, Greg L.↗

Electric power processing, distribution, management and energy storage

Power distribution subsystems are required for three elements of the SPS program: (1) orbiting satellite, (2) ground rectenna, and (3) Electric Orbiting Transfer Vehicle (EOTV). Power distribution subsystems receive electrical power from the energy conversion subsystem and provide the power busses rotary power transfer devices, switchgear, power processing, energy storage, and power management required to deliver control, high voltage plasma interactions, electric thruster interactions, and spacecraft charging of the SPS and the EOTV are also included as part of the power distribution subsystem design.

Giudici, R. J.↗

Independent Orbiter Assessment (IOA): Assessment of the electrical power distribution and control subsystem, volume 1

The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA first completed an analysis of the Electrical Power Distribution and Control (EPD and C) hardware, generating draft failure modes and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. The IOA results were then compared to the NASA FMEA/CIL baseline with proposed Post 51-L updates included. A resolution of each discrepancy from the comparison is provided through additional analysis as required. This report documents the results of that comparison for the Orbiter EPD and C hardware. The IOA product for the EPD and C analysis consisted of 1671 failure mode analysis worksheets that resulted in 468 potential critical items being identified. Comparison was made to the proposed NASA Post 51-L baseline which consisted of FMEAs and 158 CIL items. Volume 1 contains the EPD and C subsystem description, analysis results, ground rules and assumptions, and some of the IOA worksheets.

Schmeckpeper, K. R.↗

Independent Orbiter Assessment (IOA): Assessment of the Electrical Power Distribution and Control Subsystem, Volume 2

The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA first completed an analysis of the Electrical Power Distribution and Control (EPD and C) hardware, generating draft failure modes and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. The IOA results were then compared to the NASA FMEA/CIL baseline with proposed Post 51-L updates included. A resolution of each discrepancy from the comparison is provided through additional analysis as required. This report documents the results of that comparison for the Orbiter EPD and C hardware. Volume 2 continues the presentation of IOA worksheets.

Schmeckpeper, K. R.↗

Independent Orbiter Assessment (IOA): Assessment of the electrical power distribution and control subsystem, volume 3

The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA first completed an analysis of the Electrical Power Distribution and Control (EPD and C) hardware, generating draft failure modes and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. The IOA results were then compared to the NASA FMEA/CIL baseline with proposed Post 51-L updates included. A resolution of each discrepancy from the comparison is provided through additional analysis as required. This report documents the results of that comparison for the Orbiter EPD and C hardware. Volume 3 continues the presentation of IOA worksheets and contains the potential critical items list and the NASA FMEA to IOA worksheet cross reference and recommendations.

Schmeckpeper, K. R.↗

Independent Orbiter Assessment (IOA): Assessment of the Electrical Power Distribution and Control/Electrical Power Generation (EPD and C/EPG) FMEA/CIL

The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA effort first completed an analysis of the Electrical Power Distribution and Control/Electrical Power Generation (EPD and C/EPG) hardware, generating draft failure modes and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. The IOA results were then compared to the NASA FMEA/CIL baseline with proposed Post 51-L updates included. A resolution of each discrepancy from the comparison was provided through additional analysis as required. The results of that comparison is documented for the Orbiter EPD and C/EPG hardware. The IOA product for the EPD and C/EPG analysis consisted of 263 failure mode worksheets that resulted in 42 potential critical items being identified. Comparison was made to the NASA baseline which consisted of 211 FMEA and 47 CIL items.

Mccants, C. N.↗

Estimating the value of jointly optimized electric power generation and end use: a study of ISO-scale load shaping applied to the residential building stock

A generation-to-load simulation estimated the impact, in terms of production costs and CO2 emissions, attributable to the joint optimization of electric power generation and flexible end uses to support increasing penetrations of renewable energy. Newly conceived, evaluated, and foundational in developing a U.S. National Standard was a transaction-less yet continuous demand response system based on a day-ahead optimum load shape (OLS) designed to encourage Internet-connected devices to autonomously and voluntarily explore options to favour lowest cost generators - without requiring two-way communications, personally identifiable information, or customer opt-in. Boundary conditions used for model calibration included historical weather, residential building stock construction attributes, home appliance and device empirical operating schedules, prototypical power distribution feeder models, thermal generator heat rates, startup and ramping constraints, and fuel costs. Results of an hourly-based annual case study of Texas indicate a 1/3 reduction in production costs and a 1/5 reduction in CO2 emissions are possible.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Design analysis and computer-aided performance evaluation of shuttle orbiter electrical power system. Volume 2: SYSTID user's guide

The manual for the use of the computer program SYSTID under the Univac operating system is presented. The computer program is used in the simulation and evaluation of the space shuttle orbiter electric power supply. The models described in the handbook are those which were available in the original versions of SYSTID. The subjects discussed are: (1) program description, (2) input language, (3) node typing, (4) problem submission, and (5) basic and power system SYSTID libraries.

Source record↗

Independent Orbiter Assessment (IOA): Assessment of the electrical power generation/power reactant storage and distribution subsystem FMEA/CIL

The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) is presented. The IOA effort first completed an analysis of the Electrical Power Generation/Power Reactant Storage and Distribution (EPG/PRSD) subsystem hardware, generating draft failure modes and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. The IOA results were then compared to the NASA FMEA/CIL baselines with proposed Post 51-L updates included. A resolution of each discrepancy from the comparison is provided through additional analysis as required. The results of that comparison are documented for the Orbiter EPG/PRSD hardware. The comparison produced agreement on all but 27 FMEAs and 9 CIL items. The discrepancy between the number of IOA findings and NASA FMEAs can be partially explained by the different approaches used by IOA and NASA to group failure modes together to form one FMEA. Also, several IOA items represented inner tank components and ground operations failure modes which were not in the NASA baseline.

Ames, B. E.↗

Energy Equity: From Sociological Concept to Engineering Perspective of Electric Power Systems

The implementation of energy equity has emerged as a pivotal goal of the global energy transition, driven by widespread recognition of energy inequities worldwide. Because energy equity is broadly regarded as a sociological concept rather than an engineering one, the current absence of technical engineering methods necessitates the development of a justified and sound approach to making energy equity an actionable practice in the broader realms of energy, environment, and sustainability. This Perspective discusses different terms related to energy equity and proposes a generalized definition of energy equity from the engineering perspective of electric power systems. To address these challenges related to energy equity, policies in Europe and the U.S. are introduced, although their effectiveness is limited. Further, current energy equity research is classified into four categories: quantifying energy equity, improving equity in the accessibility of electricity, improving equity in the affordability of electricity, and improving equity in the resilience of power systems. Then, we classify the ongoing research challenges in energy equity into two categories, technical challenges and application challenges, and provide corresponding insights. Finally, we discuss equity of resilience or reliability, income disparity, and environmental equity, followed by a summary of this Perspective.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Small space station electrical power system design concepts

A small manned facility, i.e., a small space station, placed in earth orbit by the Shuttle transportation system would be a viable, cost effective addition to the basic Shuttle system to provide many opportunities for R&D programs, particularly in the area of earth applications. The small space station would have many similarities with Skylab. This paper presents design concepts for an electrical power system (EPS) for the small space station based on Skylab experience, in-house work at Marshall Space Flight Center, SEPS (Solar Electric Propulsion Stage) solar array development studies, and other studies sponsored by MSFC. The proposed EPS would be a solar array/secondary battery system. Design concepts expressed are based on maximizing system efficiency and five year operational reliability. Cost, weight, volume, and complexity considerations are inherent in the concepts presented. A small space station EPS based on these concepts would be highly efficient, reliable, and relatively inexpensive.

Jones, G. M.↗

STEPS: A Portable Numerical Simulation Toolkit for Electrical Power System Dynamic Studies

Numerical simulation is the key technique for large scale power system analysis. Redistribution of global renewable power via international interconnections requires new simulation tools to study the interconnected systems with different nominal frequencies as a whole. In this paper we introduce an open source simulation toolkit for electrical power systems (STEPS) which is hosted at Github. Its kernel is coded in C++ with major functions of power flow and electro-mechanical dynamic simulation. Flexible options are provided and configurable to improve power flow solution and dynamic simulation. Common devices and models are supported in STEPS for AC/DC hybrid system studies. Studies of interconnected systems with different nominal frequencies is supported in STEPS for research of international interconnection. Application program interfaces are provided and wrapped with Python to enable high-level interfaces for general applications. STEPS is thread safe and parallel computation is supported in both kernel and script levels to accelerate simulation. It is portable and works on Windows and GNU/Linux platforms. Cases from small to large scale systems are thoroughly tested to validate the toolkit with commercial packages as benchmarks.

42 ENGINEERING↗

Evaluation Studies of Solid Oxide-Based Fuel Cells for Light-Weight Electrical Power in Aviation: Concepts and Opportunities for the Application of Additive Manufacturing

Currently NASA is investigating the feasibility of hybrid-electric, solid oxide fuel cell power (SOFC) systems for generating electrical power for airborne propulsion and secondary/auxiliary power. As part of this project, researchers are investigating the performance of SOFC hardware in aviation-like environments, to establish the barriers, and potential suitability, of this technology. Immediate findings indicate the unsuitability of current SOFC stack architectures with regards to ease of manufacture, specific energy, as well as environmental and mechanical durability. One possible solution is to create light-weight high specific energy density solid oxide fuel cells. The possibility may be achievable by the use of modern processing techniques such as additive manufacturing. Here I discuss the use additive manufacturing to fabricate ceramic anode, electrolytes, and cathode cells supported on various metal foams with predicted performance based upon variable porosities

Goldsby, Jon C.↗

Modeling a High-Temperature Electrochemically Driven Water-Gas-Shift Process Using a Mixed-Conducting Membrane without External Electrical Power

This paper develops a model to predict and interpret the performance of an elevated-temperature, electrochemical, membrane-assisted, water-gas-shift process. The process uses separated feed streams of H 2 O and CO to produce separated streams of H 2 and CO 2 , without an external electrical power source. The dense ceramic membrane is mixed ionic-electronic-conducting (MIEC) gadolinium-doped ceria (GDC) and the porous composite electrodes are Ni-YSZ. At elevated temperature, GDC conducts both oxygen ions and small polarons. The present process uses chemical potential to drive the process. Electrochemical oxidation of CO proceeds within the composite anode and H 2 O reduction proceeds within the composite cathode. At high temperature (e.g., T > 700 °C), GDC has significant electronic leakage in the form of a reduced-cerium small polaron, which supports the charge-transfer reactions. In a typical electrolyzer or fuel cell, this leakage is significantly problematic. However, the present process depends on the leakage current to complete the electrochemical circuit. Model development and validation is based on measured material properties and reactor performance. Potential applications include using CO-rich blast-furnace off gases in steel processing, producing separated streams of H 2 and CO 2 .

Zhu, Huayang↗

Electric power generation using geothermal brine resources for a proof of concept facility

An exploratory systems study of a geothermal proof-of-concept facility is being conducted. This study is the initial phase (Phase 0) of a project to establish the technical and economic feasibility of using hot brine resources for electric power production and other industrial applications. Phase 0 includes the conceptual design of an experimental test-bed facility and a 10-MWe power generating facility.

Hankin, J. W.↗

Electrical-power-system data base for consumables analysis. Volume 1: Electrical equipment list, activity blocks, and time lines

A standardized data base is described which consists of a space shuttle electrical equipment list, activity blocks defining electrical equipment utilization, and activity-block time lines for specific mission analyses. Information is presented to facilitate utilization of the data base, to provide the basis for the electrical equipment utilization to enable interpretation of analyses based on the data contained herein.

Pipher, M. D.↗