Search NASA⌕ Search

SEARCH · Search NASA

Results for “Electron Accelerators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Measurement of the neutron leakage from a dedicated intraoperative radiation therapy electron linear accelerator and a conventional linear accelerator for 9, 12, 15(16), and 18(20) MeV electron energies

The issue of neutron leakage has recently been raised in connection with dedicated electron-only linear accelerators used for intraoperative radiation therapy (IORT). In particular, concern has been expressed about the degree of neutron production at energies of 10 MeV and higher due to the need for additional, perhaps permanent, shielding in the room in which the device is operated. In particular, three mobile linear accelerators available commercially offer electron energies at or above the neutron threshold, one at 9 MeV, one at 10 MeV, and the third at 12 MeV. To investigate this problem, neutron leakage has been measured around the head of two types of electron accelerators at a distance of 1 m from the target at azimuthal angles of 0 deg., 45 deg., 90 deg., 135 deg., and 180 deg. The first is a dedicated electron-only (nonmobile) machine with electron energies of 6 (not used here), 9, 12, 15, and 18 MeV and the second a conventional machine with electron energies of 6 (also not used here), 9, 12, 16, and 20 MeV. Measurements were made using neutron bubble detectors and track-etch detectors. For electron beams from a conventional accelerator, the neutron leakage in the forward direction in Sv/Gy is 2.1x10{sup -5} at 12 MeV, 1.3x10{sup -4} at 16 MeV, and 4.2x10{sup -4} at 20 MeV, assuming a quality factor (RBE) of 10. For azimuthal angles >0 deg., the leakage is almost angle independent [2x10{sup -6} at 12 MeV; (0.7-1.6)x10{sup -5} at 16 MeV, and (1.6-2.9)x10{sup -5} at 20 MeV]. For the electron-only machine, the neutron leakage was lower than for the conventional linac, but also independent of azimuthal angle for angles >0 deg. : ([0 deg. : 7.7x10{sup -6} at 12 MeV; 3.0x10{sup -5} at 15 MeV; 1.0x10{sup -4} at 18 MeV]; [other angles: (2.6-5.9)x10{sup -7} at 12 MeV; (1.4-2.2)x10{sup -6} at 15 MeV; (2.7-4.7)x10{sup -6} at 18 MeV]). Using the upper limit of 6x10{sup -7} Sv/Gy at 12 MeV for the IORT machine for azimuthal angles >0 deg. and assuming a workload of 200 Gy/wk and an inverse square factor of 10, the neutron dose equivalent is calculated to be 0.012 mSv/wk. For the primary beam at 12 MeV (0 deg. ), the 10x higher dose would be compensated by the attenuation of a primary beam stopper in a mobile linear accelerator. These neutron radiation levels are below regulatory values (National Council on Radiation Protection and Measurements, 'Limitation of exposure to ionizing radiation', NCRP Report No. 116, NCRP Bethesda, MD, 1993)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Demonstration of a real-time interferometer as a bunch-length monitor in a high-current electron beam accelerator

A real-time interferometer (RTI) has been developed to monitor the bunch length of an electron beam in an accelerator. The RTI employs spatial autocorrelation, reflective optics, and a fast response pyro-detector array to obtain a real-time autocorrelation trace of the coherent radiation from an electron beam thus providing the possibility of online bunch-length diagnostics. A complete RTI system has been commissioned at the A0 photoinjector facility to measure sub-mm bunches at 13 MeV. Bunch length variation (FWHM) between 0.8 ps ({approx}0.24 mm) and 1.5 ps ({approx}0.45 mm) has been measured and compared with a Martin-Puplett interferometer and a streak camera. The comparisons show that RTI is a viable, complementary bunch length diagnostic for sub-mm electron bunches.

43 PARTICLE ACCELERATORS↗

Plasma Density Tapering for Laser Wakefield Acceleration of Electrons and Protons

Extended acceleration in a Laser Wakefield Accelerator can be achieved by tailoring the phase velocity of the accelerating plasma wave, either through profiling of the density of the plasma or direct manipulation of the phase velocity. Laser wakefield acceleration has also reached a maturity that proton acceleration by wakefield could be entertained provided we begin with protons that are substantially relativistic, {approx}1 GeV. Several plasma density tapering schemes are discussed. The first scheme is called ''bucket jumping'' where the plasma density is abruptly returned to the original density after a conventional tapering to move the accelerating particles to a neighboring wakefield period (bucket). The second scheme is designed to specifically accelerate low energy protons by generating a nonlinear wakefield in a plasma region with close to critical density. The third scheme creates a periodic variation in the phase velocity by beating two intense laser beams with laser frequency difference equal to the plasma frequency. Discussions and case examples with simulations are presented where substantial acceleration of electrons or protons could be obtained.

43 PARTICLE ACCELERATORS↗

High-throughput injection-acceleration of electron bunches from a linear accelerator to a laser wakefield accelerator

Plasma-based accelerators (PBAs) driven by either intense lasers (laser wakefield accelerators, LWFAs) or particle beams (plasma wakefield accelerators, PWFAs), can accelerate charged particles at extremely high gradients compared to conventional radio-frequency (RF) accelerators. In the past two decades, great strides have been made in this field, making PBA a candidate for next-generation light sources and colliders. However, these challenging applications necessarily require beams with good stability, high quality, controllable polarization and excellent reproducibility. To date, such beams are generated only by conventional RF accelerators. As such, it is important to demonstrate the injection and acceleration of beams first produced using a conventional RF accelerator, by a PBA. In some recent studies on LWFA staging and external injection-acceleration in PWFA only a very small fraction (from below 0.1% to few percent) of the injected charge (the coupling efficiency) was accelerated. For future colliders where beam energy will need to be boosted using multiple stages, the coupling efficiency per stage must approach 100%. Here we report the first demonstration of external injection from a photocathode-RF-gun-based conventional linear accelerator (LINAC) into a LWFA and subsequent acceleration without any significant loss of charge or degradation of quality, which is achieved by properly shaping and matching the beam into the plasma structure. Furthermore, this is an important step towards realizing a high-throughput, multi-stage, high-energy, hybrid conventional-plasma accelerator.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Window Cooling Studies using Pulsed Beam Heating

Los Alamos National Laboratory (LANL) is working with NorthStar Medical Radioisotopes (NMR) on their efforts to produce Mo-99 through the irradiation of Mo-100 using electron accelerators. Two electron accelerators are used to irradiate a double sided target. LANL collaborates with NMR to experimentally investigate beam effects on the target which consists of two Inconel 718 windows on either side of a stack of Mo-100 disks. LANL simulates the beam heating using an induction heater.

43 PARTICLE ACCELERATORS↗

Petawatt Laser Guiding and Electron Beam Acceleration to 8 GeV in a Laser-Heated Capillary Discharge Waveguide.

Guiding of relativistically intense laser pulses with peak power of 0.85 PW over 15 diffraction lengths was demonstrated by increasing the focusing strength of a capillary discharge waveguide using laser inverse bremsstrahlung heating. This allowed for the production of electron beams with quasimonoenergetic peaks up to 7.8 GeV, double the energy that was previously demonstrated. Charge was 5 pC at 7.8 GeV and up to 62 pC in 6 GeV peaks, and typical beam divergence was 0.2 mrad.

Gonsalves, AJ↗

Electron vacuum acceleration by a tightly focused laser pulse

Interaction of a tightly focused relativistic short laser pulse with electrons beyond the paraxial approximation is studied by using the test particle approach and the Stratton-Chu integrals for the laser fields. The investigation addresses the regime where the focal spot size may be comparable to the laser wavelength. The mapping of near focal positions of the electrons to energy space allows for the study of important features of electron vacuum acceleration by a tightly focused laser pulse and to choose optimal parameters for acceleration. Two acceleration mechanisms have been observed and discussed. Directional properties of the accelerated electrons have been analyzed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nonlinear laser-driven electron resonance acceleration in an inhomogeneous magnetic field

Electron resonance acceleration by an intense laser pulse in an inhomogeneous external magnetic field is investigated. The acceleration mechanism makes use of electron cyclotron resonance to increase the electron energy. By appropriately tailoring the radial gradient of the magnetic field, an electron in the rising front part of laser pulse will be attracted toward the cyclotron-resonance radius and be trapped there, so that it can gain much energy. It is shown that the electron net energy gain can be up to the GeV level.

43 PARTICLE ACCELERATORS↗

The research progress of some key problems about the protection of industrial electron irradiation accelerator - Paper 9

In the last decades, electronic irradiation accelerator has made great progress and been widely used in fields. Because of its distinguishing feature of reliability and safety, electronic irradiation accelerator has attracted more attention of the investors, and created a huge economic value and social benefits. It will become the mainstream equipment of irradiation processing industry in future. So the further study of the shielding design around irradiation accelerator is of great significance. Different designs of ventilation duct will greatly influence dose rate of the exit. Because of the high dose rate under the target, it is suitable to use multi-tortuous duct when duct locating under target. It will reduce the dose rate about 3 orders of magnitude at the exit that add one backscattering interface in duct. Choose reasonable diameter and angle of embedded duct so that photons scatter as much as possible. We can use multiple small diameter ducts to replace large diameter duct. The system of Mini-DDL, Gamma detector and PC give a better reflection on the running statue of accelerator, its perfect usability can produce intuitive images for analyzed, it is important and helpful for workers and researchers to know about the radiation level of machine and environment. The measured results along the maze show that the maze must be long enough in order to achieve the desired shielding thickness. In future, we will combine the different kinds and motor patterns of body models, Monte Carlo programs, real time monitoring system with theoretical calculations to explore how the radiation field around accelerator has impact on human organs, get the dose distribution of body models so that improve the radiation protection to electron accelerator. (authors)

43 PARTICLE ACCELERATORS↗

Comparison of measured with calculated dose distribution from a 120-MeV electron beam from a laser-plasma accelerator

Purpose: To evaluate the dose distribution of a 120-MeV laser-plasma accelerated electron beam which may be of potential interest for high-energy electron radiation therapy. Methods: In the interaction between an intense laser pulse and a helium gas jet, a well collimated electron beam with very high energy is produced. A secondary laser beam is used to optically control and to tune the electron beam energy and charge. The potential use of this beam for radiation treatment is evaluated experimentally by measurements of dose deposition in a polystyrene phantom. The results are compared to Monte Carlo simulations using the geant4 code. Results: It has been shown that the laser-plasma accelerated electron beam can deliver a peak dose of more than 1 Gy at the entrance of the phantom in a single laser shot by direct irradiation, without the use of intermediate magnetic transport or focusing. The dose distribution is peaked on axis, with narrow lateral penumbra. Monte Carlo simulations of electron beam propagation and dose deposition indicate that the propagation of the intense electron beam (with large self-fields) can be described by standard models that exclude collective effects in the response of the material. Conclusions: The measurements show that the high-energy electron beams produced by an optically injected laser-plasma accelerator can deliver high enough dose at penetration depths of interest for electron beam radiotherapy of deep-seated tumors. Many engineering issues must be resolved before laser-accelerated electrons can be used for cancer therapy, but they also represent exciting challenges for future research.

61 RADIATION PROTECTION AND DOSIMETRY↗

Increased laser-accelerated proton energies via direct laser-light-pressure acceleration of electrons in microcone targets

We present experimental results showing a laser-accelerated proton beam maximum energy cutoff of 67.5 MeV, with more than 5 x 10{sup 6} protons per MeV at that energy, using flat-top hollow microcone targets. This result was obtained with a modest laser energy of {approx}80 J, on the high-contrast Trident laser at Los Alamos National Laboratory. From 2D particle-in-cell simulations, we attribute the source of these enhanced proton energies to direct laser-light-pressure acceleration of electrons along the inner cone wall surface, where the laser light wave accelerates electrons just outside the surface critical density, in a potential well created by a shift of the electrostatic field maximum with respect to that of the magnetic field maximum. Simulations show that for an increasing acceleration length, the continuous loading of electrons into the accelerating phase of the laser field yields an increase in high-energy electrons.

43 PARTICLE ACCELERATORS↗

High intensity electron cyclotron resonance proton source for low energy high intensity proton accelerator

Electron cyclotron resonance (ECR) proton source at 50 keV, 50 mA has been designed, developed, and commissioned for the low energy high intensity proton accelerator (LEHIPA). Plasma characterization of this source has been performed. ECR plasma was generated with 400-1100 W of microwave power at 2.45 GHz, with hydrogen as working gas. Microwave was fed in the plasma chamber through quartz window. Plasma density and temperature was studied under various operating conditions, such as microwave power and gas pressure. Langmuir probe was used for plasma characterization using current voltage variation. The typical hydrogen plasma density and electron temperature measured were 7x10{sup 11} cm{sup -3} and 6 eV, respectively. The total ion beam current of 42 mA was extracted, with three-electrode extraction geometry, at 40 keV of beam energy. The extracted ion current was studied as a function of microwave power and gas pressure. Depending on source pressure and discharge power, more than 30% total gas efficiency was achieved. The optimization of the source is under progress to meet the requirement of long time operation. The source will be used as an injector for continuous wave radio frequency quadrupole, a part of 20 MeV LEHIPA. The required rms normalized emittance of this source is less than 0.2 {pi} mm mrad. The simulated value of normalized emittance is well within this limit and will be measured shortly. This paper presents the study of plasma parameters, first beam results, and the status of ECR proton source.

43 PARTICLE ACCELERATORS↗

Influence of asymmetric injection of laser radiation into capillary waveguides on wake acceleration of electrons possessing various injection energies

Laser wakefield acceleration of electron bunches possessing various initial injection energies in capillary waveguides is studied in the conditions of an asymmetric input of laser radiation into a waveguide (the propagation direction of laser radiation deviates from the capillary axis or the laser spot is not symmetric). The factors determining the critical angle of the laser radiation input into the capillary, within which the wake acceleration of electrons is close to optimal, have been found. It is shown that in acceleration stages where electron energies are high, the requirements to angular concentricity of the capillary axis and laser radiation focusing are substantially weaker due to the relativistic 'weighting' of the electron mass. (extreme laser radiation: physics and fundamental applications)

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Direct Acceleration of Electrons in a Corrugated Plasma Channel

Direct laser acceleration of electrons provides a low power tabletop alternative to laser wakefield accelerators. Until recently, however, direct acceleration has been limited by diffraction, phase matching, and material damage thresholds. The development of the corrugated plasma channel [B. Layer et al., Phys. Rev. Lett. 99, 035001 (2007)] has removed all of these limitations and promises to allow direct acceleration of electrons over many centimeters at high gradients using femtosecond lasers [A. G. York et al., Phys Rev. Lett 100, 195001 (2008), J. P. Palastro et al., Phys. Rev. E 77, 036405 (2008)]. We present a simple analytic model of laser propagation in a corrugated plasma channel and examine the laser-electron beam interaction. Simulations show accelerating gradients of several hundred MeV/cm for laser powers much lower than required by standard laser wakefield schemes. In addition, the laser provides a transverse force that confines the high energy electrons on axis, while expelling low energy electrons.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Generation and acceleration of electron bunches from a plasma photocathode

Plasma waves generated in the wake of intense, relativistic laser or particle beams can accelerate electron bunches to gigaelectronvolt energies in centimetre-scale distances. This allows the realization of compact accelerators with emerging applications ranging from modern light sources such as the free-electron laser to energy frontier lepton colliders. In a plasma wakefield accelerator, such multi-gigavolt-per-metre wakefields can accelerate witness electron bunches that are either externally injected or captured from the background plasma. Here in this work, we demonstrate optically triggered injection and acceleration of electron bunches, generated in a multi-component hydrogen and helium plasma employing a spatially aligned and synchronized laser pulse. This ‘plasma photocathode’ decouples injection from wake excitation by liberating tunnel-ionized helium electrons directly inside the plasma cavity, where these cold electrons are then rapidly boosted to relativistic velocities. The injection regime can be accessed via optical density down-ramp injection and is an important step towards the generation of electron beams with unprecedented low transverse emittance, high current and 6D-brightness. This experimental path opens numerous prospects for transformative plasma wakefield accelerator applications based on ultrahigh-brightness beams.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The acceleration of electrons at perpendicular shocks and its implication for solar energetic particle events

We present a study of the acceleration of electrons at a perpendicular shock that propagates through a turbulent magnetic field. The energization process of electrons is investigated by utilizing a combination of hybrid (kinetic ions and fluid electron) simulations and test-particle electron simulations. In this method, the motions of the test-particle electrons are numerically integrated in the time-dependent electric and magnetic fields generated by two-dimensional hybrid simulations. We show that large-scale magnetic fluctuations effect electrons in a number of ways and lead to efficient and rapid energization at the shock front. Since the electrons mainly follow along magnetic lines of force, the large-scale braiding of field lines in space allows the fast-moving electrons to interact with the shock front and get accelerated multiple times. Ripples in the shock front occurring at various scales will also contribute to the acceleration by mirroring the electrons. Our calculation shows that this process favors electron acceleration at perpendicular shocks. The acceleration efficiency is critically dependent on the turbulence amplitude and coherence length. We also discuss the implication of this study for solar energetic particles (SEPs) by comparing the acceleration of electrons with that of protons. Their correlation indicates that perpendicular shocks play an important role in SEP events.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗