Search NASA⌕ Search

SEARCH · Search NASA

Results for “Electron accelerator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Scaling of laser-driven electron and proton acceleration as a function of laser pulse duration, energy, and intensity in the multi-picosecond regime

A scaling study of short-pulse laser-driven proton and electron acceleration was conducted as a function of pulse duration, laser energy, and laser intensity in the multi-picosecond (ps) regime (~0.8 ps–20 ps). Furthermore, maximum proton energies significantly greater than established scaling laws were observed, consistent with observations at other multi-ps laser facilities. In addition, maximum proton energies and electron temperatures in this regime were found to be strongly dependent on the laser pulse duration and preplasma conditions. A modified proton scaling model is presented that is able to better represent the accelerated proton characteristics in this multi-ps regime.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Particle acceleration in impulsive solar flares

A model for second-step electron acceleration in impulsive solar flares is presented. The theory of stochastic particle acceleration is extended to include Coulomb energy losses which become important at low coronal heights. This inclusion successfully explains the observed steepening of interplanetary electron spectra below about 3 MeV following impulsive solar flares taking place at low coronal heights. It also explains the observed spectral differences of relativistic electrons in long-duration and impulsive flares.

Steinacker, J.↗

Multiwavelength Emission From Pulsar Slot Gaps

We present results of a 3D model of optical to gamma-ray emission from the slot gap accelerator of a rotation-powered pulsar. Primary electrons accelerating to high altitude in the pulsar magnetosphere at the outer edge of the open field volume, as well as electron-positron pairs on field line interior to the slot gap, radiate curvature, inverse Compton and synchrotron radiation. Both primaries and pairs undergo cyclotron resonant absorption of radio photons, allowing them to maintain significant pitch angles and to produce a broad spectrum of emission from infra-red to GeV energies. Synchrotron radiation from pairs with a power-law energy spectrum dominate the spectrum up to 10 MeV. Synchrotron and curvature radiation of primaries dominates from 10 MeV up to a few GeV. The high-energy pulse profiles are dominated by caustics on trailing field lines. In the case of the Crab pulsar, the radio conal emission may also form caustics in phase with the high-energy peaks. If resonant absorption of radio emission produces high-energy synchroti-on radiation, emission below 200 Mev is expected to exhibit correlations in time and phase with the radio emission.

Harding, Alice K.↗

Improving Cathode Testing with a High-Gradient Cryogenic Normal Conducting RF Photogun

Future electron accelerator applications such as X-ray free electron lasers and colliders are dependent on significantly increasing beam brightness. With the observation that linac beam manipulation’s best preservation of max brightness is at the cathode, we are incentivized to create an environment where we can study how to achieve the highest possible photogun brightness. In order to do so, we intend to extract beams from high-brightness photocathodes with the highest achievable accelerating gradients we can manage in a klystron-powered radiofrequency (RF) photogun. We utilize here cryogenic normal conducting cavities to achieve ultra-high gradients via limitation of breakdown rates (BDR). The low temperatures should also reduce cathode emittance by reducing the mean transverse energy (MTE) of electrons near the photoemission threshold. To this end, we have designed and produced a new CrYogenic Brightness-Optimized Radiofrequency Gun (CYBORG) for use in a new beamline at UCLA. We will introduce the enabling RF and photoemission physics as a primer for the new regime of high field low temperature cathodes we intend to enter. We further report the current status of the beamline commissioning, including the cooling of the photogun to 100 K, and producing 0.5 MW of RF feed power, which corresponds to cathode accelerating fields in the range of 80–90 MV/m. We further plan iterative improvements to both to 77 K and 1 MW corresponding to our ultimate goal >120 MV/m. Our discussion will include future beamline tests and the consideration of the initial realization of an ultra-high-gradient photoinjector concept.

Lawler, Gerard Emile (ORCID:0000000160113435)↗

High-Altitude Emission from Pulsar Slot Gaps: The Crab Pulsar

We present results of a 3D model of optical to gamma-ray emission from the slot gap accelerator of a rotation-powered pulsar. Primary electrons accelerating to high-altitudes in the unscreened electric field of the slot gap reach radiation-reaction limited Lorentz factors of approx. 2 x 10(exp 7), while electron-positron pairs from lower-altitude cascades flow along field lines interior to the slot gap. The curvature, synchrotron and inverse Compton radiation of both primary electrons and pairs produce a broad spectrum of emission from infra-red to GeV energies. Both primaries and pairs undergo cyclotron resonant absorption of radio photons, allowing them to maintain significant pitch angles. Synchrotron radiation from pairs with a power-law energy spectrum from gamma = 10(exp 2) - 10(exp 5), dominate the spectrum up to approx. 10 MeV. Synchrotron and curvature radiation of primaries dominates from 10 MeV up to a few GeV. We examine the energy-dependent pulse profiles and phase-resolved spectra for parameters of the Crab pulsar as a function of magnetic inclination alpha and viewing angle zeta, comparing to broad-band data. In most cases, the pulse profiles are dominated by caustics on trailing field lines. We also explore the relation of the high-energy and the radio profiles, as well as the possibility of caustic formation in the radio cone emission. We find that the Crab pulsar profiles and spectrum can be reasonably well reproduced by a model with alpha = 45deg and zeta approx. 100deg or 80deg. This model predicts that the slot gap emission below 200 MeV will exhibit correlations in time and phase with the radio emission.

Harding, Alice K.↗

Emergency vacuum repairs in an aging accelerator: Case studies and lessons learned

Jefferson Lab operates the CEBAF electron accelerator at energies to 12 GeV for the Department of Energy Nuclear Physics program. The CEBAF injector beamline was designed and built in the early 1990s. Although we’ve upgraded and replaced many of the vacuum systems, we still have unique original components installed which operate daily. Over the past 3 years, we have had several vacuum leaks in ageing components leading to emergency repairs on a tight timeline. I’ll discuss the nature of these vacuum component failures, the difficulties in repair due to their ages, the lessons we’ve learned, and how we hope to minimize similar failures going forward.

Stutzman, Marcy [Thomas Jefferson National Acceler↗

Electron Cooling in NICA Acceleration Complex

The Nuclotron-based Ion Collider fAcility (NICA) is under assembling at JINR. NICA will provide colliding beams for study of hot strongly interacting baryonic matter and spin physics. The NICA injection complex includes a tandem of 2 superconducting synchrotrons: Booster (up to 600 MeV/u) and Nuclotron (up 3.9 GeV/u fully stripped heavy ions). Since the start of injection complex commissioning in 2020 its four Runs were carried out. To the present time the beams of He, Fe, C and Xe were accelerated. Booster electron cooling was first used for cooling of continuous Fe¹⁴⁺ beam at the energy of 3.2 MeV/u in Run II. In the last Run we demonstrated longitudinal cooling of Xe²⁸⁺ in the presence of RF voltage at the Booster injection energy. This regime is required for accumulation in Booster the intensity required for Collider operation. The cooling enabled a 2 times intensity increase of slow extracted beam from Nuclotron. Optimization of Booster electron cooling for beam accumulation will be carried out in the next Run. Another (high voltage) electron cooling system will be used in the NICA Collider rings for ion accumulation in a barrier bucket and consecutive bunch formation.

43 PARTICLE ACCELERATORS↗

Dual-RF Phase Control for Adiabatic Energy Ramping in the EIC Rapid Cycling Synchrotron

The Electron-Ion Collider (EIC) Rapid Cycling Synchrotron (RCS) accelerates electrons from 750 MeV to 10 GeV over approximately 64.7 ms. While the baseline design simultaneously ramps both RF voltage and phase, this study evaluates an alternative where RF cavities are divided into two groups, each operating at a fixed 6.5 MV, with the effective voltage synthesized through phase control. In the symmetric scheme (Option A), both groups vary symmetrically about the synchronous phase to provide exact matching of energy gain and synchrotron tune throughout the ramp. Conversely, the asymmetric scheme (Option B) pins one group at the final operating phase while the other varies to supply the required energy gain. The feasibility of Option B is determined by the adiabaticity of the resulting synchrotron tune evolution, with ramp profiles, phase trajectories, and adiabaticity metrics analyzed for both implementations.

Gamage, B. [Thomas Jefferson National Accelerator ↗

Hardening of MJS77 spacecraft against the Jupiter radiation belts

Results of the device characterization program to identify components of the Mariner Jupiter/Saturn spacecraft in need of radiation hardening to meet a total dose requirement of 5 trillion e/sq cm are presented. The parts to be tested, including bipolar transistors, JFETs, SCRs, CMOS devices, linear integrated circuits, Zener diodes and other radiation-sensitive parts, were identified by a worst case circuit analysis of the 20 major subsystems. The test samples were exposed to several levels of irradiation from a Dynamitron electron accelerator capable of producing a steady stream of electrons at energies up to 2.5 eV. The electrical parameters of the devices were measured immediately following irradiation to prevent annealing. CMOS devices and linear devices showed the most severe degradation in a moderate radiation environment, and significant degradation was produced at low current in bipolar transistors. Three methods used for screening a number of devices determined by circuit and shielding analyses to be unacceptable radiation-sensitive are described: diffusion and metallization lot screening; wafer lot screening; and irradiation-anneal screening.

W E Price↗

Evolution of Interplanetary Shocks and their CME Drivers

Shock-driving coronal mass ejections (CMEs) constitute the most energetic phenomena in the heliosphere. The shocks can be identified in a number of ways based on remote-sensing and in situ observations. Type II radio bursts are the earliest indicators of shocks that accelerate electrons to energies up to -10 keV. Solar energetic particle (SEP) events are always accompanied by long wavelength type II bursts indicating that the same shock accelerates ions and electrons. A recent investigation involving a large number of interplanetary (IP) shocks revealed that about 35% of them do not produce type II bursts (radio quiet, RQ) or SEPs. Comparison of the RQ shocks with the radio loud (RL) ones revealed some interesting results such as: (1) the lack of evidence for blast waves,(2) energetic particle enhancement in the shock front in -20% of RQ shocks, and (3) determination of the difference between the RQ and RL shocks in terms of the different kinematic properties of the associated CMEs. On the other hand the shock properties measured at I AU are not too different for the RQ and RL cases. This can be attributed to the interaction with the IP medium, which seems to erase the difference. Implications of this evolution for the geoeffectiveness is also discussed.

Gopalswamy, Natchimuthuk↗

Experimental demonstration of externally driven millimeter-wave particle accelerator structure

We report the experimental demonstration of a mm-wave electron accelerating structure powered by a high-power rf source. We demonstrate reliable coupling of an unprecedented rf power—up to 575kW into the mm-wave accelerator structure using a quasi-optical setup. This standing wave accelerating structure consists of a single-cell copper cavity and a Gaussian to TM 01 mode converter. The accelerator structure is powered by 110 GHz, 10-ns long rf pulses. These pulses are chopped from 3 microsecond pulses from a gyrotron oscillator using a laser-driven silicon switch. We show an unprecedented high gradient up to 230MV/m that corresponds to a peak surface electric field of more than 520 MV/m. We have achieved these results after conditioning the cavity with more than 100,000 pulses. We also report preliminary measurements of rf breakdown rates, which are important for understanding rf breakdown physics in the millimeter-wave regime. Furthermore, these results open up many frontiers for applications not only limited to the next generation particle accelerators but also x-ray generation, probing material dynamics, and nonlinear light-matter interactions at mm-wave frequency.

43 PARTICLE ACCELERATORS↗

Energy Transport and Conversion Above a Bright Discrete Auroral Arc

Magnetically connected observations of particle distributions and luminosity from the Reimei spacecraft are used to examine energy transport and conversion occurring above a discrete auroral arc. By combining imaging and in situ measurements it is shown how transverse electromagnetic and kinetic energy fluxes measured along the spacecraft trajectory converge across geomagnetic field-lines into the acceleration region. It is shown how cross-field energy transport is facilitated by the formation of vortices along the length of the arc. From an integration over the vertical extent of the acceleration region it is shown that the transverse and field-aligned flow of energy into the arc locally supports the dissipation needed to power the electron acceleration observed. Estimates of gradients in electromagnetic and kinetic energy flows show how field-aligned electron energization in the acceleration region is supported by the divergence of Poynting flux along and across the background magnetic field.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electron injection and acceleration at nonlinear shocks: Results of numerical simulations

We present results of numerical simulations of electron injection and acceleration at nonlinear high Mach number shocks. The electrons are assumed to be heated at the thermal subshock to an energy E(sub inj), which is treated as a free parameter, above which they are injected by self-generated whistlers to momentum m(sub p) x V(sub A). This injection mechanism requires Mach numbers greater than (43/(beta(sub -)))(((k T(sub e))/(E(sub inj)))(exp 1/2)), where T(sub e) and beta (sub -) are the upstream electron temperature and plasma beta parameter. Above m(sub p) x V(sub A) electrons are trapped in the shock by Alfven waves. In the proton precursor region the Alfven waves are assumed to be generated by protons accelerated at the shock, and have nonlinear intensities. Below GeV, however, electrons of a given rigidity propagate faster than protons with a similar rigidity and therefore diffuse to regions ahead of the proton precursor. In those regions the Alfven waves are generated by the electrons themselves. The diffusion coefficient appears to increase with decreasing acceleration efficiency. As a result, the number of electrons accelerated to energies GeV and above and, hence, the electron to proton ratio, depend only weakly on the extent of electron heating at the subshock. The negative feedback also renders the electron spectra insensitive to shock compression ratio and smoothing length scale. The estimated e/p ratio at GeV is between approximately 1%-10%.

Levinson, Amir↗

Radio evidence for nonthermal particle acceleration on stars of late spectral type

Radio evidence for nonthermal particle acceleration on stars of late spectral type (G, K, and M) is reviewed, including the pre-main-sequence T Tauri stars, the dwarf M flare stars, and the RS CVn binary stars. Both the long-lasting radio emission and the transient radio flares can be attributed to nonthermal electrons accelerated in magnetically confined coronae, radiating by either incoherent gyrosynchrotron radiation or by coherent processes. Related observations of the Sun provide the framework for interpreting the radio emission of late-type stars. We review recent Very Long Base Interferometry (VLBI) observations of single and binary stars, observations of rapid acceleration and dynamic spectra of dwarf M flare stars, and models for long-lasting radio emission from dwarf M flare stars and RS CVn stars. The VLBI data provide evidence for nonthermal particle acceleration in large-scale magnetospheres several times larger than the stellar radius for T Tauri and RS CVn stars. In contrast, rapid radio flares on dwarf M stars require sources much smaller than the visible star in size, and this is consistent with the VLBI data. Dynamic spectra suggest particle acceleration by relativistic electron beams on dwarf M stars. The long-lived radio radiation of dwarf M stars and RS CVn stars requires more-or-less continuous particle acceleration over periods of hours, perhaps by persistent low-amplitude flaring.

Lang, Kenneth R.↗

Flow Induced Vibration Studies in Pressurized Helium Gas Cooling Channels

Production of metastable Technetium-99 (Tc-99m), a radioactive tracer that emits gamma rays, is vital to the medical imaging community. Tc-99m is extracted from the decay of Molybdenum-99 (Mo-99) which has a half-life of about 2-3 days. The work presented in this report is part of the NNSA’s mission to produce Mo-99 commercially, within the US, without the use of highly enriched uranium (HEU) in support of nonproliferation and global security. Los Alamos National Laboratory (LANL) is working with NorthStar Medical Radioisotopes (NMR) on their efforts to produce Mo-99 through the irradiation of Mo-100 targets using an electron beam. The NMR target comprises a stack of approximately 60-70 Mo-100 disks with diameter 24 mm and thickness 0.74 mm held in stainless steel laminations, each separated using 0.25 mm thick stainless steel spacers. The symmetric target stack is housed in an Inconel vessel with two Inconel windows on either side. Two electron accelerators are used to produce 40 MeV, 3.16 µA electron beams each that penetrate the Inconel windows and irradiate the Mo-100 disks. Approximately 90% of the total 250 kW beam power is deposited in the NMR target during the irradiation process. During irradiation, pressurized helium gas flows through 0.25 mm thin gaps between the disks cooling the beam window, target disks, disk laminations and spacers. Both NMR and LANL have found during cold testing of the target system (no heat deposition) that the Mo-100 disks undergo significant mass loss and disk breakage due to vibrations induced by the flowing helium gas. The mass loss is not only undesirable due to monetary loss from reduced final quantities of Mo-99, but also due to the hazards associated with radioactive material trapped in the cooling lines and particle filters. The effect of flow rate and target geometry on the flow induced vibrations need to be quantified, and recommendations provided to minimize this mass loss. This work describes LANL’s experimental characterization of the flow induced vibrations and disk mass loss in a reduced scale set-up containing 10 Mo-100 disks. We use high speed imaging, displacement measurements and microphone measurements combined with signal processing to estimate the vibration frequency of each disk. The effect of disk thickness, target fit and duration of testing on the mass loss is described. We find that in the current configuration of NMR targets, the vibrations and mass loss on the first disk are minimized, while those in the adjacent disks are highest. The microphone and high-speed image data show that increased flow rates and increased duration of testing increases vibration frequency and mass loss. The mass loss is due to both disk rotation and back and forth motion. There are visible wear marks on the disks with the highest mass loss. We also note that the current NMR window gap reduces flow induced vibrations compared to the previous smaller gaps. Longer duration testing will provide more data and verification for the findings presented in this report. The work will be continued in FY 24.

43 PARTICLE ACCELERATORS↗

Window Cooling Studies and Disk Vibration Testing on a Subset of Mo-100 Disks

Production of metastable Technetium-99 (Tc-99m), a radioactive tracer that emits gamma rays, is vital to the medical imaging community. Tc-99m is extracted from the decay of Molybdenum-99 (Mo-99) which has a half-life of about 2-3 days. The work presented in this report is part of the NNSA’s mission to produce Mo-99 commercially, within the US, without the use of highly enriched uranium (HEU) in support of nonproliferation and global security. Los Alamos National Laboratory (LANL) is working with NorthStar Medical Radioisotopes (NMR) on their efforts to produce Mo-99 through the irradiation of Mo-100 targets using an electron beam. The NMR target comprises a stack of approximately 60-70 Mo-100 disks with diameter 24 mm and thickness 0.74 mm held in stainless steel laminations, each separated using 0.25 mm thick stainless-steel spacers. The symmetric target stack is housed in an Inconel vessel with two Inconel windows on either side. Two electron accelerators are used to produce 40 MeV, 3.16 µA electron beams each that penetrate the Inconel windows and irradiate the Mo-100 disks. Approximately 90% of the total 250 kW beam power is deposited in the NMR target during the irradiation process, with a smaller percentage adding up to 2.2 kW of heat deposited on the Inconel window. During irradiation, pressurized helium gas flows through thin gaps between the disks cooling the beam window, target disks, disk laminations and spacers. Both NMR and LANL have found during cold testing of the target system (no heat deposition) that the Mo 100 disks undergo significant mass loss and disk breakage due to vibrations induced by the flowing helium gas. The mass loss is not only undesirable due to monetary loss from reduced final quantities of Mo-99, but also due to the hazards associated with radioactive material trapped in the cooling lines and particle filters. The effect of flow rate and target geometry on the flow induced vibrations need to be quantified, and recommendations provided to minimize this mass loss. LANL has previously also tested NMR’s Inconel beam window by heating the window, while flowing pressurized helium, using the average heat deposited on the window. However, the NMR beam is pulsed with a duty cycle of 12.5%, which introduces oscillation in temperature around the nominal 600 °C steady state value with each pulse. Available fatigue curves for Inconel are few, established for room temperature, and they are based on mechanical strain cycles not thermally induced strain as in the NMR target. The effect of pulsed beam heating on the Inconel window therefore needs to be quantified. This report details the experiments conducted to assess the factors that lead to mass loss in the NMR target disks as well as to understand the effect of a pulsed beam on NMR’s Inconel window. This work describes LANL’s experimental characterization of the flow induced vibrations and disk mass loss in a reduced scale set-up containing 5 to 10 Mo-100 disks. We use high speed imaging, displacement measurements and microphone measurements combined with signal processing to estimate the vibration frequency of each disk. The effect of disk thickness, target fit and duration of testing on the mass loss is described. We find that in the current configuration of NMR targets, the vibrations and mass loss on the first disk are minimized, while those in the adjacent disks are highest. The microphone and high-speed image data show that increased flow rates and increased duration of testing increases vibration frequency and mass loss. The mass loss is due to both disk rotation and back and forth motion. There are visible wear marks on the disks with the highest mass loss. We also note that the current NMR window gap reduces flow induced vibrations compared to the previous smaller gaps. Improved target holders significantly reduce disk mass loss to almost negligible quantities. This work finds that the larger window to first disk gap and improved target holder geometry should allow NMR to successfully conduct irradiations with minimal mass loss. The window tests were conducted to understand the effect of a pulsed beam on both the window longevity and to estimate the window temperature and displacement during pulsing. The experiments presented here were performed at significantly low power, due to the limitations of the induction heating system. The window temperature rose to approximately 73 °C with a significantly reduced power of 45 W without beam pulsing. With a 5 Hz pulse rate, 12.5% duty cycle, the window temperature remained constant at 26 °C. These experiments will be repeated with improved coil geometry and reported in upcoming journal papers.

42 ENGINEERING↗

Operational Experience of the NML Cryogenic Plant at the FAST Test Facility

The New Muon Laboratory (NML) cools two individually cryostated superconducting radio frequency (SRF) capture cavities (CC) and one prototype ILC cryomodule (CM) with eight SRF cavities. This complex accelerates electrons at 150 MeV for the Integrable Optics Test Accelerator (IOTA) ring, located at the Fermilab Accelerator Science and Technology (FAST) facility. Since 2019, this R&D accelerator complex has gone through four science runs.

Wallace, T. [Fermilab]↗

Operational Experience of the NML Cryogenic Plant at the FAST Test Facility

The NML cryogenic plant cools two individually cryostated superconducting radio frequency (SRF) capture cavities and one prototype ILC cryomodule with eight SRF cavities. This complex accelerates electrons at 150 MeV for the Integrable Optics Test Accelerator (IOTA) ring, located at the Fermilab Accelerator Science and Technology (FAST) facility. The cryogenic plant is composed of two nitrogen precooled Tevatron satellite refrigerators, two Mycom 2016C compressors, a cryogenic distribution system, a Frick purifier compressor, two charcoal bed adsorber purifiers, and a liquid ring vacuum pump with a roots booster. The SRF cavities are immersed in a 2.0 K liquid helium bath, shielded with a 5 K gaseous helium shield and a liquid nitrogen cooled thermal shield. Since 2019, this R&D accelerator complex has gone through four science runs with an average duration of 12 months. Operational experience for each run, availability metrics, performance data and common outages are presented in this paper.

Wallace, Timothy [Fermilab] (ORCID:000900051589302↗