Effect of ultraviolet irradiation on selected plastic films in vacuum
Ultraviolet radiation effects in vacuum on plastic films used as encapsulants for thin film cadmium sulfide solar cells
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Ultraviolet radiation effects in vacuum on plastic films used as encapsulants for thin film cadmium sulfide solar cells
Dry heat inactivation of Bacillus globigii spores encapsulated in Lucite to simulate interplanetary spacecraft conditions
Performance evaluation tests on encapsulating polyurethane elastomeric compound, type III
Performance evaluation tests on encapsulating polyurethane elastometric compound, type III
High voltage strength of polyurethane plastic foams for encapsulant applications
Low work function cathode configurations and nickel encapsulated powder for withstanding intensive ion bombardment
Health and safety precautions, materials, procedures, and quality assurance controls to be used in encapsulating high voltage electrical assemblies in polyurethane foam
This viewgraph presentation reviews exploration activities at JPL into various potting materials. Since high power space-borne microwave transmitters invariably use a vacuum tube as a final power amplifier, and this tube requires high electrode voltages for operation. The associated high voltage insulation typically represents a significant fraction of the mass of the transmitter. Since mass is always a premium resource on board spacecraft, we have been investigating materials with the potential to reduce the mass required for our applications here at JPL. This paper describes electrical breakdown results obtained with various potting materials. Conathane EN-11 (polyurethane) is the traditional HVPS encapsulant at JPL, but due to temperature limitations and durability issues it was deemed inappropriate for the particular application (i.e., CloudSat radar). The choices for the best available materials were epoxies, or silicones. Epoxies are too rigid, and were deemed inadvisable. Two silicones were further investigated (i.e.,ASTM E595- 93e2: GE RTV566(R) and Dow Corning 93-500X(R), another compound was considered (i.e., DC material, Sylgard 184(R)). "Loading" (adding filler materials) the potting compound will frequently alter the final material properties. Powdered alumina and borosilicate glass known as "microballoons" were investigated as possible loading materials. The testing of the materials is described. Each of the two loading materials offers advantages and disadvantages. The advantages and disadvantages are described.
Objective ot this project was to investigate sealing methods for encapsulating samples in 1 cm diameter thin-walled sample tubes applicable to future proposed Mars Sample Return Techniques implemented include a spring energized Teflon sleeve plug, a crimped tube seal, a heat-activated shape memory alloy plug, a shape memory alloy activated cap, a solder-based plug, and a solder-based cap
A connector for use in the thermocouple circuits which is silver-brazed to the metal thermocouple sheath on one end and crimped over the insulation of the flexible lead on the other, assures protection against breakage and abrasion. A moisture-proof insulating material is used to encapsulate the wire junctions.
The electronics system of the Telstar satellite is described from the point of view of philosophy of design and construction rather than that of circuit details. The reliability is emphasized, and steps taken to preserve the inherent reliability of the components are discussed. The physical construction of modules, subsystems, and finally the entire system is described, including the foam encapsulation and the eventual hermetic sealing of the canister.
High energy anode and cathode development, electrolyte encapsulation, tape activation, and parasitic operation techniques for dry tape battery concept
Microphone used as a phonocardiograph transducer monitors small amplitude audio signals in the presence of large shock loads and high humidity. It contains a lead zirconate-lead titanate piezoelectric plate encapsulated in a flexible polyurethane resin. The resin is contained in a sealed nylon case having a diameter of less than one inch.
Dry heat resistance of bacilus globigii spores encapsulated in lucite and dried on paper strips for spacecraft contamination experiment
Rigid polyurethane foam encapsulation of high- voltage aerospace electronic systems, noting vacuum effect
Thermoluminescence dosimeter technique measures thermal-neutron fluence by encapsulating lithium flouride phosphor powder and exposing it to a neutron environment. The capsule is heated in a dosimeter reader, which results in light emission proportional to the neutron fluence.
Strain gage load transducer measures axial embedment stresses in resins used for encapsulation of welded electronic modules. It simulates the geometry of an actual electronic component and can be modified in size, shape, and operating temperature.
Electron beam remelted tungsten technetium alloys forged while encapsulated in molybdenum cans - surface appearance and edge cracking properties