Search NASA⌕ Search

SEARCH · Search NASA

Results for “Energy Code”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

SimProp: a simulation code for ultra high energy cosmic ray propagation

A new Monte Carlo simulation code for the propagation of Ultra High Energy Cosmic Rays is presented. The results of this simulation scheme are tested by comparison with results of another Monte Carlo computation as well as with the results obtained by directly solving the kinetic equation for the propagation of Ultra High Energy Cosmic Rays. A short comparison with the latest flux published by the Pierre Auger collaboration is also presented.

79 ASTRONOMY AND ASTROPHYSICS↗

Residential Heat Recovery Ventilation

Heat recovery ventilators (HRVs) save energy by recovering heat that would otherwise be exhausted as part of energy code-mandated mechanical ventilation systems. Residential HRVs can be life cycle cost effective depending on equipment/installation costs and the severity of the climate. This brief evaluates HRV cost effectiveness in the context of building energy codes to identify the climate zones in which a code might reasonably require residential HRVs.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Preparing an Incompressible-Flow Fluid Dynamics Code for Exascale-Class Wind Energy Simulations

The U.S. Department of Energy has identified exascale-class wind farm simulation as critical to wind energy scientific discovery. A primary objective of the ExaWind project is to build high-performance, predictive computational fluid dynamics (CFD) tools that satisfy these modeling needs. GPU accelerators will serve as the computational thoroughbreds of next-generation, exascale-class supercomputers. Here, we report on our efforts in preparing the ExaWind unstructured mesh solver, Nalu-Wind, for exascale-class machines. For computing at this scale, a simple port of the incompressible-flow algorithms to GPUs is insufficient. To achieve high performance, one needs novel algorithms that are application aware, memory efficient, and optimized for the latest-generation GPU devices. The result of our efforts are unstructured-mesh simulations of wind turbines that can effectively leverage thousands of GPUs. In particular, we demonstrate a first-of-its-kind, incompressible-flow simulation using Algebraic Multigrid solvers that strong scales to more than 4000 GPUs on the Summit supercomputer.

algebraic multigrid↗

Fully energy-dependent HZETRN (a galactic cosmic-ray transport code)

For extended manned space missions, the radiation shielding design requires efficient and accurate cosmic-ray transport codes that can handle the physics processes in detail. The Langley Research Center galactic cosmic-ray transport code (HZETRN) is currently under development for such design use. The cross sections for the production of secondary nucleons in the existing HZETRN code are energy dependent only for nucleon collisions. The approximation of energy-independent, heavy-ion fragmentation cross section is now removed by implementing a mathematically simplified energy-dependent stepping formalism for heavy ions. The cross section at each computational grid is obtained by linear interpolation from a few tabulated data to minimize computing time. Test runs were made for galactic cosmic-ray transport through a liquid hydrogen shield and a water shield at solar minimum. The results show no appreciable change in total fluxes or computing time compared with energy-independent calculations. Differences in high LET (linear energy transfer) spectra are noted, however, because of the large variation in cross sections at the low-energy region. The high LET components are significantly higher in the new code and have important implications on biological risk estimates for heavy-ion exposure.

Shinn, Judy L.↗

Energy and Energy Cost Savings Analysis of the IECC for Commercial Buildings

The purpose of this analysis is to assess the relative energy and energy cost performance of commercial buildings designed to meet the requirements found in the commercial energy efficiency provisions of the International Energy Conservation Code (IECC). Section 304(b) of the Energy Conservation and Production Act (ECPA), as amended, requires the Secretary of Energy to make a determination each time a revised version of ASHRAE Standard 90.1 is published with respect to whether the revised standard would improve energy efficiency in commercial buildings. As many states have historically adopted the IECC for both residential and commercial buildings, PNNL has evaluated the impacts of the commercial provisions of the 2006, 2009, and 2012 editions of the IECC. PNNL also compared energy performance with corresponding editions of ANSI/ASHRAE/IES Standard 90.1 to help states and local jurisdictions make informed decisions regarding model code adoption.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Energy Storage System Safety Documenting and Validating Compliance with Codes and Standards

Energy, environmental, and economic challenges are spurring more widespread consideration and use of energy storage systems (ESSs), which in turn are driving increased development of new ways to store energy electrochemically, mechanically, and thermally. These new methods necessitate an increased focus on ensuring that public health, safety, and welfare are not adversely affected—something that has been addressed for many years through codes, standards, and regulations (CSR5)1. CSRs provide requirements that establish a basis for determining if an ESS is safe, whether electrochemical, mechanical, or thermal and regardless of the range of ESS applications, energy capacities, physical sizes, location, or number installed at any given site. The key to achieving desired safety goals, as memorialized through CSRs, is through documenting and validating compliance with applicable CSRs. The process of documenting and validating compliance, which is a key component to the initial approval as well as continuing acceptance of an ESS installation, is generally called conformity assessment.

25 ENERGY STORAGE↗

Toward Energy-Efficient HPC: Insights from Power Profiling a Cloud-Resolving Earth System Model

Power is a fundamental constraint as supercomputing advances to exascale. Efficient operation within strict power budgets requires application-aware power management based on a detailed understanding of application-level power behavior. This work analyzes the Energy Exascale Earth System Model (E3SM) atmosphere component, SCREAM, on Perlmutter (NERSC) and Frontier (OLCF). We characterize power variation across inputs, concurrency levels, and power caps, evaluate the energy impact of code optimizations, and attribute energy within the code using a newly developed GPU energy model. Results show that SCREAM’s peak power remains stable during its core execution phase and decreases gradually as concurrency increases. Power capping experiments reveal a performance–energy "sweet spot". On Perlmutter, limiting GPU power to 50% of thermal design power (TDP) achieves up to 15% energy savings with a 7% performance penalty. On Frontier, a 40% TDP cap yields up to 10% energy savings with less than 10% performance loss. Code optimizations reduce SCREAM energy by shortening run time without increasing power. Modeling reveals a critical insight: data movement accounts for approximately 70% of SCREAM’s GPU energy. This fundamentally shifts the optimization focus from FLOPS to data transfer reduction for this class of applications, offering the most impactful strategy for improving energy efficiency. This work establishes a foundation for practical, application-aware power management at exascale.

Zhao, Zhengji [Lawrence Berkeley National Laborato↗

Real-time Implementation of Grid Code Compliant Grid Edge Energy Management System

Integrated distributed energy resources (DER) in a distribution system need to follow grid codes to avoid violations that result in DER/circuit segment disconnection. To comply with grid code requirements at the grid edge level, network constrained grid edge energy management system (EMS) can be deployed. The objective of grid edge EMS is to provide economic solution for active and reactive power DER setpoints at each dispatch interval and ensure voltage regulation to support secure interconnection of the grid edge segment to the distribution system with multiple inverter based DER units. In this work, real-time simulation of grid code compliant grid edge EMS is deployed in a realistic feeder circuit segment. For real-time simulation, communication between the grid edge EMS and DERs is done exploiting IEC 61850-7-420. It enables interoperability among different DERs and grid edge EMS. No prior art has deployed IEC 61850-7-420 GOOSE communication protocol for grid edge EMS. Conversion of IEC 61850 GOOSE messages to Modbus communication protocol is also performed to communicate with grid edge EMS in commodity-off the shelf embedded boards in this work. The real-time simulation in OPAL-RT real-time digital simulator shows the out-performance of grid edge EMS by reducing the voltage violation in the distribution circuit.

Energy management system↗

Balanced Excitatory and Inhibitory Synaptic Currents Promote Efficient Coding and Metabolic Efficiency

A balance between excitatory and inhibitory synaptic currents is thought to be important for several aspects of information processing in cortical neurons in vivo, including gain control, bandwidth and receptive field structure. These factors will affect the firing rate of cortical neurons and their reliability, with consequences for their information coding and energy consumption. Yet how balanced synaptic currents contribute to the coding efficiency and energy efficiency of cortical neurons remains unclear. We used single compartment computational models with stochastic voltage-gated ion channels to determine whether synaptic regimes that produce balanced excitatory and inhibitory currents have specific advantages over other input regimes. Specifically, we compared models with only excitatory synaptic inputs to those with equal excitatory and inhibitory conductances, and stronger inhibitory than excitatory conductances (i.e. approximately balanced synaptic currents). Using these models, we show that balanced synaptic currents evoke fewer spikes per second than excitatory inputs alone or equal excitatory and inhibitory conductances. However, spikes evoked by balanced synaptic inputs are more informative (bits/spike), so that spike trains evoked by all three regimes have similar information rates (bits/s). Consequently, because spikes dominate the energy consumption of our computational models, approximately balanced synaptic currents are also more energy efficient than other synaptic regimes. Thus, by producing fewer, more informative spikes approximately balanced synaptic currents in cortical neurons can promote both coding efficiency and energy efficiency.

59 BASIC BIOLOGICAL SCIENCES↗

Modeling Proton- and Light Ion-Induced Reactions at Low Energies in the MARS15 Code

An implementation of both ALICE code and TENDL evaluated nuclear data library in order to describe nuclear reactions induced by low-energy projectiles in the Monte Carlo code MARS15 is presented. Comparisons between results of modeling and experimental data on reaction cross sections and secondary particle distributions are shown.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Spherical Active Coded Aperture for 4π Gamma-ray Imaging

Gamma-ray imaging facilitates the efficient detection, characterization, and localization of compact radioactive sources in cluttered environments. Fieldable detector systems employing active planar coded apertures have demonstrated broad energy sensitivity via both coded aperture and Compton imaging modalities. But, planar configurations suffer from a limited field-of-view, especially in the coded aperture mode. In order to improve upon this limitation, we introduce a novel design by rearranging the detectors into an active coded spherical configuration, resulting in a 4pi isotropic field-of-view for both coded aperture and Compton imaging. This work focuses on the low- energy coded aperture modality and the optimization techniques used to determine the optimal number and configuration of 1 cm 3 CdZnTe coplanar grid detectors on a 14 cm diameter sphere with 192 available detector locations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Preliminary Energy Costs and Savings Estimates: 2018 IECC Residential Requirements

This report provides preliminary estimates of the incremental costs and savings associated with the residential provisions of the 2018 International Energy Conservation Code (IECC). The analysis is provided to the U.S. Department of Energy (DOE) to help quantify the costs and savings impacts of the latest published edition of the IECC, the 2018 IECC. The incremental cost of building to the 2018 IECC, relative to the 2015 IECC, ranges from $\$398$ to $\$1,071$ depending on the climate zone, and payback periods range from 0 (immediate) to 1.8 years, depending on the climate zone.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Inventory of Safety-related Codes and Standards for Energy Storage Systems with some Experiences related to Approval and Acceptance

The purpose of this document is to identify laws, rules, model codes, codes, standards, regulations, specifications (CSR) related to safety that could apply to stationary energy storage systems (ESS) and experiences to date securing approval of ESS in relation to CSR. This information is intended to assist in securing approval of ESS under current CSR and to identification of new CRS or revisions to existing CRS and necessary supporting research and documentation that can foster the deployment of safe ESS.

Conover, David R.↗

Energy Use Savings for a Typical New Residential Dwelling Unit Based on the 2009 and 2012 IECC as Compared to the 2006 IECC

The 2009 and 2012 International Energy Conservation Codes (IECC) require a substantial improvement in energy efficiency compared to the 2006 IECC. This report averages the energy use savings for a typical new residential dwelling unit based on the 2009 and 2012 IECC compared to the 2006 IECC. Results are reported by the eight climate zones in the IECC and for the national average.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Recent MCNP® Code Developments and Improvements for Nuclear Energy Applications [Slides]

The MCNP® code is a general-purpose radiation transport code developed at LANL over the past 46+ years. This code is capable of modeling the fundamental physics of particles as they move through and interact with materials. It is used in many LANL and worldwide radiation transport applications (see next slide) for example in the Fundamental nuclear physics and data experiments at LANSCE.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Air Leakage and Air Transfer Between Garage and Living Space

This research project focused on evaluation of air transfer between the garage and living space in a single-family detached home constructed by a production homebuilder in compliance with the 2009 International Residential Code and the 2009 International Energy Conservation Code. The project gathered important information about the performance of whole-building ventilation systems and garage ventilation systems as they relate to minimizing flow of contaminated air from garage to living space. A series of 25 multi-point fan pressurization tests and additional zone pressure diagnostic testing characterized the garage and house air leakage, the garage-to-house air leakage, and garage and house pressure relationships to each other and to outdoors using automated fan pressurization and pressure monitoring techniques. While the relative characteristics of this house may not represent the entire population of new construction configurations and air tightness levels (house and garage) throughout the country, the technical approach was conservative and should reasonably extend the usefulness of the results to a large spectrum of house configurations from this set of parametric tests in this one house. Based on the results of this testing, the two-step garage-to-house air leakage test protocol described above is recommended where whole-house exhaust ventilation is employed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗