Search NASA⌕ Search

SEARCH · Search NASA

Results for “Energy Utilization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Air quality and comfort constrained energy efficient operation of multi-zone buildings

Maintaining indoor air quality (IAQ) through effective ventilation is essential for the well-being and productivity of building occupants. Control strategies aimed at improving the efficiency of heating, ventilation and air conditioning (HVAC) systems must jointly determine ventilation and heating and cooling processes. Here, in this paper, we study the problem of minimizing the energy consumption of the HVAC system in a multi-zone building, while meeting thermal comfort and IAQ requirements. We first perform a steady state analysis of the zonal carbon dioxide (CO 2 ) concentration and the temperature dynamics. The resulting expressions are convex in the zonal mass flow rates and zonal temperatures. Guided by the steady state solutions for meeting the thermal comfort constraints, we develop two control policies for improving the energy efficiency of building HVAC systems while jointly satisfying indoor temperature and IAQ constraints. We compare the performance of our proposed approaches with those of multiple baseline approaches which implement separate regimes for controlling zonal temperature and IAQ for a typical work-day in a multi-zone campus building. We have evaluated the performance of our proposed approaches under varying levels of flexibility in zonal temperatures. We have shown that zonal temperature flexibility can result in energy savings up to 32% (for the same control strategies) as compared to the case where no such flexibility is permitted. Our proposed approaches were seen to offer potential savings of nearly 29% compared to the baseline.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy efficiency and thermal resilience analysis for row houses using representative building energy models

Row houses, a prevalent medium-density urban archetype, were popularized during industrial era to accommodate the working class in the U.S. cities. Today, many of these structures are deteriorating, exacerbating the energy cost for residents with limited economic resources. Moreover, many households that lack Air Conditioning (AC) are vulnerable to extreme summer heat, an issue expected to worsen in the future. Energy-efficient retrofits can help mitigate these challenges. However, current literature provides limited insight into how existing building energy codes impact the energy efficiency and thermal resilience of row houses in current and future weather scenarios. This study provides a detailed method to address this gap by employing calibrated representative energy models of row houses as a baseline, and evaluating the annual energy savings and summertime thermal safety improvements from code compliant retrofits under current and future typical weather conditions. Using Baltimore City as a case study, results show that under current weather, retrofitting row houses yields significant energy savings along with notable thermal resilience improvements. The end unit row house realizes higher energy savings, whereas the interior unit experiences greater thermal resilience improvement after retrofitting. In future, retrofitted row houses can still save energy, but residents will face numerous hours of fatal indoor temperatures without AC in summer. Additionally, findings reveal stark zone-wise variations in thermal safety, and elevated humidity risks in certain zones post-retrofit, emphasizing the need for zonal retrofit strategies and better natural ventilation strategies.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

How Do Electricity Pricing Programs Impact the Selection of Energy Efficiency Measures? - A Case Study with U.S. Medium Office Buildings

Building owners usually select energy efficiency measures (EEMs) by referring to return on investment (ROI). Current studies tend to apply static energy price to estimate ROI. However, more and more buildings are adopting dynamic electricity pricing programs. To understand how electricity pricing programs impact the selection of EEMs, this paper presents an analysis of the ROIs of EEMs under different pricing programs using U.S. medium office buildings as an example. Eight EEMs in four typical cities are selected as case studies. Considering five electricity pricing programs scenarios (one static program and four dynamic programs), EEMs are selected based on their ROIs. The main findings are: (1) The ROIs of EEMs change under different pricing programs. (2) In Honolulu, Buffalo, and Denver, replacing interior fixtures with higher-efficiency fixtures has a significantly higher ROI than the rest EEMs under all five pricing programs. However, the ROI of this EEM in Honolulu ranges from 28% to 47% for different pricing programs. (3) Similarly, in Fairbanks, replace heating coil with higher-efficiency coil produce higher ROI than the rest under all five pricing programs. (4) For other EEMs, their ROI rankings vary according to electricity pricing programs.

demand response↗

Real time side-by-side experimental validation of energy and comfort performance of a zero net energy retrofit package for small commercial buildings

Making buildings zero-net energy (ZNE) is one of the major strategies for achieving carbon emission reduction goals. For this strategy to be successful, it entails a very significant reduction in energy use – 50% or more. In small commercial buildings, however, owners and building management teams usually have limited resources for identifying, analyzing, and procuring appropriate retrofit measures for reducing such use. An approach to overcome this limitation is the development of bundles of energy efficiency measures that can be presented to building owners/operators as a comprehensive package. The research presented in this paper focuses on an experimental evaluation of the impacts of a retrofit package developed for small office buildings in California. Performing this evaluation in a full-scale whole-building integrated systems test facility allowed a side-by-side evaluation in real time, against a reference case, of the impact of the retrofit package not only on energy use but also on visual and thermal comfort. Here, the retrofit package evaluated is comprised of a combination of HVAC, lighting (including daylighting), and plug load measures. The evaluation occurred at different times of the year in order to account for seasonal variations in environmental conditions, including solar angles and weather. The experimental facility allowed testing for two different façade orientations: south and west. Results show that the proposed ZNE retrofit package can save significant amounts of energy for small commercial buildings. During cooling-prevalent periods, total energy savings were 65% for south orientation and 68% for west orientation; during heating-prevalent periods total energy savings were 22% for south orientation and 25% for west orientation. Measurements indicate that the ZNE retrofit package resulted in small but not very significant changes in comfort levels for building occupants.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Component-Level Analysis of Heating and Cooling Loads in the U.S. Residential Building Stock

The residential building sector accounts for a substantial portion of total energy consumption in the United States and offers a significant opportunity for energy reduction and decarbonization through improvements in energy efficiency. Heating and air conditioning are the primary contributors to residential energy usage and electricity system peak demand. However, due to the diversity of the housing stock and the complexity of factors affecting heating and cooling demand, identifying the relative contributions to heating and cooling loads poses challenges. To address this, we applied the ResStock analysis tool to simulate 550,000 building energy models, providing statistical representation of residential buildings in the contiguous United States. We introduced outputs that quantified the heating and cooling influence of different components of a home, such as air leakage, envelope components (ceilings, walls, windows, foundations), internal heat gains from people, lighting, plug loads, and duct losses and gains. Leveraging the granularity of ResStock, we present a dataset to enable deeper understanding of the contributors to heating and cooling loads as a function of housing characteristics such as location, envelope efficiency, and building type. This work aims to support prioritization of research and development and informed decision-making for residential building decarbonization.

building simulation↗

Comparative Analysis of Model Predictive Control and MPC-Informed Rule-Based Control for Thermal Storage Operation in Ultra-Low Temperature 4th Generation District Heating Networks

The integration of thermal storage and heat pumps in district heating networks (DHNs) can significantly enhance operational flexibility and energy efficiency; however, the practical deployment of advanced control strategies is often hindered by forecasting requirements and computational complexity. This study presents a comparative analysis of thermal storage control strategies in an ultra-low-temperature fourth-generation DHN, focusing on the development of a simplified rule-based control (RBC) explicitly informed by Model Predictive Control (MPC) behavior. The proposed methodology systematically analyzes the charging and discharging decisions of an MPC-controlled system under ideal forecasting conditions and extracts recurrent control patterns as a function of key system variables, including outdoor temperature, thermal demand, and electricity price. These patterns are translated into a set of structured time- and condition-based rules, resulting in an MPC-informed RBC that embeds predictive insights while preserving implementation simplicity and operational transparency. The approach is validated on a realistic mixed-use urban district in Denver, Colorado, USA, equipped with a centralized air-source heat pump, distributed water-to-water heat pumps, and a central thermal storage unit. Results show that the tuned RBC attains approximately 96% of ideal MPC economic performance (-27% of costs), preserves values of technical and environmental indicators (reduction only of 2-3%), and substantially reduces complexity. Sensitivity analyses further demonstrate the robustness of the RBC under varying operational conditions (i.e., ambient temperature, electricity price). Overall, the study demonstrates that MPC-informed rule-based control represents an effective trade-off between control performance and real-world applicability, enabling the integration of additional system components while maintaining simplicity, robustness, and ease of implementation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimality versus reality: Closing the gap between renewable energy decision models and government deployment in the United States

Energy decision models are widely used to evaluate the technical and economic feasibility of renewable energy, as well as to help inform the deployment of these technologies. However, a gap exists between the optimal model solutions and what is deployed. This paper explores why these gaps exist in the public sector using the results of interviews with 20 federal, state, and city government agencies that have used the Renewable Energy Integration and Optimization (REopt™) model to inform energy decisions. We then propose adaptations to technical modeling capabilities, and communication of results, which may help increase clean energy deployment. This research may be useful to both analytical modelers and the organizations using such decision tools to inform policy, regulation, planning, and deployment of clean energy systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimizing Phase Change Composite Thermal Energy Storage Using the Thermal Ragone Framework

The thermal Ragone framework can be applied to the design of thermal energy storage heat exchangers to identifying relationships between their power requirements and energy capabilities. This presentation focuses on the design of planar thermal energy storage heat exchangers with phase change materials and thermal conductivity additives. Finite-difference models were used to optimize thermal storage heat exchanger designs focusing on key design parameters of conductivity additive volume fraction, spacing between tubes, and the phase transition temperatures. Design trends were developed for optimal designs based on varying thermal power requirements. To aid in future device design, models of reduced complexity were developed with the ability to predict optimal designs with computational speeds up to 5,000 times faster than finite-difference models.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION,↗

Numerical Simulations of High Prandtl Number Liquid Jets Impinging on a Flat Plate

In this work, 3D simulations of oil jets impinging on a flat, heated wall are presented. The numerical setup uses the Volume of Fluid (VoF) method to model the two-phase flow. A careful grid definition across the liquid film, along with the use of the Conjugate Heat Transfer (CHT) approach allowed local heat transfer to be solved with fine resolution at the wall. Variations of liquid flow rate, liquid temperature and surface temperature allow to cover a wide range of local Reynolds and Prandtl numbers (226 < Re < 2850, 77 < Pr < 161). Resulting surface-averaged heat transfer compares very well with experimental measurements conducted in a previous study. In-depth analysis of the flow has identified expected features from the literature. In particular, the impact of jet axial velocity profiles on the heat transfer distribution in the stagnation zone was clearly stated. The increase in heat transfer when warming the liquid film was also reproduced and explained by a decrease in oil viscosity and an increase in film velocity. All those effects were taken into account in correlations for stagnation and local values of Nusselt number. A grid sensitivity study was also conducted, showing that if the grid solving the thermal boundary layer in the stagnation zone can be coarsened without impacting local and surface-averaged predictions of heat transfer, a minimum resolution (2 to 3 cells) within the thermal boundary layer is however required for an accurate prediction of heat transfer.

conjugate heat transfer↗

A high efficiency rooftop air conditioning system using multi-speed compressors

This study delineates a meticulous exploration of technologies to enhance the energy efficiency of rooftop air conditioning units, employing the DOE/ORNL heat pump design model for comprehensive engineering design and optimization. A baseline rooftop air conditioning unit, featuring a 13 ton (45.7 kW) cooling capacity and a 17.9 integrated energy efficiency ratio, served as the point of departure for substantive efficiency enhancements. Key modifications included the consolidation of two refrigerant circuits into one, integrating three parallel 2-stage (dual-speed) compressors, fan replacements with high-efficiency substitutes. Notably, a lower global warming potential refrigerant, R452B, was evaluated as a substitute for R-410A, demonstrating better performance in the lab prototype. Further, the achieved measured integrated energy efficiency ratio of 21.4 in the lab prototype surpassed the baseline integrated energy efficiency ratio. Comparative evaluations between R410A and R452B indicated heightened efficiency with the latter, showcasing a lab-demonstrated integrated energy efficiency ratio of 22.4 at the rated capacity of 13.8 ton (48.5 kW) and 23.9 integrated energy efficiency ratio at the rated capacity of 10 ton (35.2 kW). This research underscores the successful development of a rigorous, energy efficient rooftop air conditioning unit prototype with noteworthy environmental and economic implications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗