Traveling Wave Energy Analysis of Faults on Power Distribution Systems

This paper explores the most important factors that define the Traveling Wave (TW) propagation on distribution systems. The factors considered in this work are: the distance to the fault location, the fault type, and the crossing of system elements (such as regulators, capacitor banks, laterals, and extra loads within the protection zones). This work uses a realistic, yet simplified, distribution system composed of two protection zones, in which, several combinations of the previously mentioned factors are considered. The simulated fault measurements undergo a signal processing stage in which, first, they are decomposed into independent modes using the Karrenbauer transform. Second, a time–frequency representation is obtained using the Stationary Wavelet Transform (SWT), dividing the signal into several frequency bands. Finally, the Parseval’s Energy (PE) theorem is applied to calculate the signal energy in each frequency band. A qualitative analysis is performed based on the previously calculated energies to outline which are the factors that most affect the TW energy during propagation. The results show that distance, the presence of regulators, either in the propagation path or upstream, and the type of fault are the main factors that affect TW propagation across the system, and therefore they should be considered for TW-based protection schemes for distribution systems.

Jiménez-Aparicio, Miguel (ORCID:000000016864461X)↗

Influence of plateau, slope, and valley on soil hydrology during the dry season in a Central Amazon old‐growth forest

Soil moisture regulates plant water supply and drought sensitivity in tropical forests, yet its vertical and topographic variation remains poorly characterized. We combined high-frequency time-domain reflectometry measurements from 5 to 100 cm across plateau, slope, and valley landforms at the Zona Florestal 2 research site north of Manaus, Central Amazonia, to quantify how soil moisture memory, timing of responses to rainfall, dry-down rates (τ), and soil–water depletion vary across these contrasting landforms. Landform-specific soil moisture calibration curves ensured accurate volumetric water content estimates in these highly weathered soils. During the 2023 dry-to-wet transition (August–November), soil moisture memory showed strong topographic contrasts, with valley profiles increasing from ∼47 h at 5 cm to ∼154 h at 100 cm, while plateaus exhibited higher near-surface persistence (∼124 h at 5 cm) but weaker memory at depth. Dry-down behavior reinforced these differences as valley soils exhibited τ values exceeding ∼200 h, more than double the characteristic τ of plateau soils (∼90 h). Rainfall–soil moisture correlations indicated immediate responses at shallow depths in valleys and progressively longer lags with depth on plateaus and slopes. These hydrologic patterns were mirrored in depletion profiles, which declined sharply below 30 cm on plateaus but remained high and sustained throughout the upper meter in slopes and valleys. Together, these findings provide the first depth-resolved field measurements of soil moisture memory, rainfall coupling, dry-down constants, and depletion dynamics across major upland landforms in Central Amazonia and offer clear observational benchmarks for improving land-surface and ecosystem model representations of soil–water processes.

Hillslope↗

CsrA-mediated regulation of a virulence switch in Acinetobacter baumannii

CsrA is an RNA binding protein that functions as a global regulator in bacteria. We demonstrate that, in Acinetobacter baumannii, CsrA acts as a positive regulator of the switch from virulent (VIR-O) to avirulent (AV-T) subpopulations. This regulation is mediated, in part, by CsrA interfering with Rho-dependent termination in the mRNA leader region of the ABUW_1645 gene, encoding the primary TetR-type transcriptional regulator that drives cells from the VIR-O to the AV-T state. We demonstrate that CsrA directly binds to the ABUW_1645 mRNA leader region and interferes with Rho binding. We identify three small RNAs (sRNAs) designated CsrB, CsrC, and CsrD that bind to CsrA and inhibit its activity. Individual overexpression of each sRNA greatly decreased the rate of VIR-O to AV-T switching. Individual deletions of each sRNA increased the frequency of VIR-O to AV-T switching, with loss of CsrB giving the highest increase at 2.4-fold. The expression of each sRNA was strongly dependent on the GacA response regulator and the expression of each sRNA was higher in VIR-O cells than in AV-T variants. Furthermore, this regulation provides a mechanism for the differential control of CsrA activity between VIR-O and AV-T variants.

59 BASIC BIOLOGICAL SCIENCES↗

Effect of head-down-tilt bed rest and hypovolemia on dynamic regulation of heart rate and blood pressure

Adaptation to head-down-tilt bed rest leads to an apparent abnormality of baroreflex regulation of cardiac period. We hypothesized that this "deconditioning response" could primarily be a result of hypovolemia, rather than a unique adaptation of the autonomic nervous system to bed rest. To test this hypothesis, nine healthy subjects underwent 2 wk of -6 degrees head-down bed rest. One year later, five of these same subjects underwent acute hypovolemia with furosemide to produce the same reductions in plasma volume observed after bed rest. We took advantage of power spectral and transfer function analysis to examine the dynamic relationship between blood pressure (BP) and R-R interval. We found that 1) there were no significant differences between these two interventions with respect to changes in numerous cardiovascular indices, including cardiac filling pressures, arterial pressure, cardiac output, or stroke volume; 2) normalized high-frequency (0.15-0.25 Hz) power of R-R interval variability decreased significantly after both conditions, consistent with similar degrees of vagal withdrawal; 3) transfer function gain (BP to R-R interval), used as an index of arterial-cardiac baroreflex sensitivity, decreased significantly to a similar extent after both conditions in the high-frequency range; the gain also decreased similarly when expressed as BP to heart rate x stroke volume, which provides an index of the ability of the baroreflex to alter BP by modifying systemic flow; and 4) however, the low-frequency (0.05-0.15 Hz) power of systolic BP variability decreased after bed rest (-22%) compared with an increase (+155%) after acute hypovolemia, suggesting a differential response for the regulation of vascular resistance (interaction, P < 0.05). The similarity of changes in the reflex control of the circulation under both conditions is consistent with the hypothesis that reductions in plasma volume may be largely responsible for the observed changes in cardiac baroreflex control after bed rest. However, changes in vasomotor function associated with these two conditions may be different and may suggest a cardiovascular remodeling after bed rest.

Non-NASA Center↗

Maximization of the region of exponential absolute stability.

The problem of selecting a regulator vector which yields the largest estimate of the region of exponential absolute stability is considered. Reformulation of an extended version of the Popov frequency condition in terms of a nonnegative polynomial gives the desired algorithm in mathematical programming format.

Karmarkar, J. S.↗

The 2x2 quasi-optical power combiner array at 20 GHz

Investigation of a power combiner made of two FET oscillators for an active array are reported. As an approach by a quasi-optical method, a two-dimensional planar array of strongly coupled oscillators by direct connection through a microstrip line is used. In-phase condition between the oscillators as well as in-phase condition of each radiation wave was accomplished by regulating length of feed microstrip lines. The radiation elements of 1 lambda-slot are embedded in a circuit ground plane. At an operation frequency of 20 GHz, in both H- and E-planes, reasonable sigma radiation patterns were obtained which have good agreement with theoretical patterns.

Kawasaki, Shigeo↗

Sequential design of linear quadratic state regulators with prescribed eigenvalues and specified relative stability

This paper considers the problem of optimal regulator design of linear multivariable systems with prescribed pole locations and/or poles corresponding to specified relative stability. A sequential method based on the frequency-domain optimality condition is proposed for achieving the desired pole assignment and determination of the corresponding quadratic performance index. This design method enables the retention of some stable open-loop poles and the associated eigenvectors in the closed-loop system. An illustrative example is provided to demonstrate the effectiveness of the proposed method.

Ganesan, Sekar↗

Gender differences in autonomic cardiovascular regulation: spectral, hormonal, and hemodynamic indexes

The autonomic nervous system drives variability in heart rate, vascular tone, cardiac ejection, and arterial pressure, but gender differences in autonomic regulation of the latter three parameters are not well documented. In addition to mean values, we used spectral analysis to calculate variability in arterial pressure, heart rate (R-R interval, RRI), stroke volume, and total peripheral resistance (TPR) and measured circulating levels of catecholamines and pancreatic polypeptide in two groups of 25 +/- 1.2-yr-old, healthy men and healthy follicular-phase women (40 total subjects, 10 men and 10 women per group). Group 1 subjects were studied supine, before and after beta- and muscarinic autonomic blockades, administered singly and together on separate days of study. Group 2 subjects were studied supine and drug free with the additional measurement of skin perfusion. In the unblocked state, we found that circulating levels of epinephrine and total spectral power of stroke volume, TPR, and skin perfusion ranged from two to six times greater in men than in women. The difference (men > women) in spectral power of TPR was maintained after beta- and muscarinic blockades, suggesting that the greater oscillations of vascular resistance in men may be alpha-adrenergically mediated. Men exhibited muscarinic buffering of mean TPR whereas women exhibited beta-adrenergic buffering of mean TPR as well as TPR and heart rate oscillations. Women had a greater distribution of RRI power in the breathing frequency range and a less negative slope of ln RRI power vs. ln frequency, both indicators that parasympathetic stimuli were the dominant influence on women's heart rate variability. The results of our study suggest a predominance of sympathetic vascular regulation in men compared with a dominant parasympathetic influence on heart rate regulation in women.

Non-NASA Center↗

NASA Unmanned Aircraft (UA) Control and Non-Payload Communication (CNPC) System Waveform Trade Studies

Unmanned Aircraft Systems (UAS) represent a new capability that will provide a variety of services in the government (public) and commercial (civil) aviation sectors. The growth of this potential industry has not yet been realized due to the lack of a common understanding of what is required to safely operate UAS in the National Airspace System (NAS). To address this deficiency, NASA has established a project called UAS Integration in the NAS (UAS in the NAS), under the Integrated Systems Research Program (ISRP) of the Aeronautics Research Mission Directorate (ARMD). This project provides an opportunity to transition concepts, technology, algorithms, and knowledge to the Federal Aviation Administration (FAA) and other stakeholders to help them define the requirements, regulations, and issues for routine UAS access to the NAS. The safe, routine, and efficient integration of UAS into the NAS requires new radio frequency (RF) spectrum allocations and a new data communications system which is both secure and scalable with increasing UAS traffic without adversely impacting the Air Traffic Control (ATC) communication system. These data communications, referred to as Control and Non-Payload Communications (CNPC), whose purpose is to exchange information between the unmanned aircraft and the ground control station to ensure safe, reliable, and effective unmanned aircraft flight operation. A Communications Subproject within the UAS in the NAS Project has been established to address issues related to CNPC development, certification and fielding. The focus of the Communications Subproject is on validating and allocating new RF spectrum and data link communications to enable civil UAS integration into the NAS. The goal is to validate secure, robust data links within the allocated frequency spectrum for UAS. A vision, architectural concepts, and seed requirements for the future commercial UAS CNPC system have been developed by RTCA Special Committee 203 (SC-203) in the process of determining formal recommendations to the FAA in its role provided for under the Federal Advisory Committee Act. NASA intends to conduct its research and development in keeping with this vision and associated architectural concepts. The prototype communication systems developed and tested by NASA will be used to validate and update the initial SC-203 requirements in order to provide a foundation for SC-203's Minimum Aviation System Performance Standards (MASPS).

Aircraft Communications↗

Commercial building loads providing ancillary services In PJM

The adoption of low carbon energy technologies such as variable renewable energy and electric vehicles, coupled with the efficacy of energy efficiency to reduce traditional base load has increased the uncertainty inherent in the net load shape. Handling this variability with slower, traditional resources leads to inefficient system dispatch, and in some cases may compromise reliability. Grid operators are looking to future energy technologies, such as automated demand response (DR), to provide capacity-based reliability services as the need for these services increase. While DR resources are expected to have the flexibility characteristics operators are looking for, demonstrations are necessary to build confidence in their capabilities. Additionally, building owners are uncertain of the monetary value and operational burden of providing these services. To address this, the present study demonstrates the ability of demand response resources providing two ancillary services in the PJM territory, synchronous reserve and regulation, using an OpenADR 2.0b signaling architecture. The loads under control include HVAC and lighting at a big box retail store and variable frequency fan loads. The study examines performance characteristics of the resource: the speed of response, communications latencies in the architecture, and accuracy of response. It also examines the frequency and duration of events and the value in the marketplace which can be used to examine if the opportunity is sufficient to entice building owners to participate.

MacDonald, Jason↗

The resilience value of residential solar + storage systems in the continental U.S.

Abstract Behind the meter rooftop solar plus storage (PVESS) has the potential to benefit the hosting customers by providing affordability, environmental, and reliability and resilience value. Whereas the bill reduction and environmental benefits of PVESS are well studied, its monetary resilience benefits are less understood. The increasing trend of power interruptions driven by extreme weather events heightens the need to understand these benefits. This study leverages various publicly available datasets to perform a cost benefit analysis of adding to determine the resilience value of PVESS for a typical single family home in each county in the continental U.S. We find that PVESS is very effective to technically mitigate interruptions across the country. However, the monetary benefits in the base case only cover about 14% of battery costs, with no county exceeding 60%. This is somewhat expected, given that PVESS provide other monetary benefits that are not part of this analysis. Through sensitivities, we find that higher frequency of extreme weather events roughly triples the resilience value of PVESS and that higher values of lost load double the same metric. Our sensitivity analysis shows that the benefit cost ratio of PVESS for customers living in areas with higher-than-average frequency of long duration interruptions and value of lost load is already above one even without considering other value streams. We conclude with recommendations that regulators and utilities could implement to enable customers to calculate and capture the resilience value of PVESS more efficiently.

Baik, Sunhee↗

Development and planning and design of equipment pumping generator of semiconductor lasers

The schematic of a multidimensional current pulse generator is studied. A MTKh-90 cold cathode thyratron is used as the current commutator. In the autooscillation mode on a frequency of 380 hertz the generator creates a current to 100 amps per pulse in a control resistance of 1 ohm. The pulse duration is regulated within the limits from 0.1 to 3.0 microseconds.

Popkov, A. V.↗

Multivariable flight control synthesis and literal robustness analysis for an aeroelastic vehicle

An integrated flight/aeroelastic control law is developed analytically for a hypothetical large supersonic transport aircraft in which the first aeroelastic mode frequency of the fuselage (6 rad/sec) is near the short-period mode (2 rad/sec). The approach employed is based on a linear-quadratic-regulator (LQR) formulation (yielding model-following state-feedback gains), followed by asymptotic loop-transfer recovery of LQR robustness (to produce an output-feedback control law). The derivation is outlined, and numerical results comparing the performance and multivariate stability robustness of the present controller with those of a classical controller are presented in graphs. The two controllers are shown to have similar characteristics, even with respect to the sources of limitations on robustness.

Schmidt, David K.↗

Filtering and Control of High Speed Motor Current in a Flywheel Energy Storage System

The NASA Glenn Research Center has been developing technology to enable the use of high speed flywheel energy storage units in future spacecraft for the last several years. An integral part of the flywheel unit is the three phase motor/generator that is used to accelerate and decelerate the flywheel. The motor/generator voltage is supplied from a pulse width modulated (PWM) inverter operating from a fixed DC voltage supply. The motor current is regulated through a closed loop current control that commands the necessary voltage from the inverter to achieve the desired current. The current regulation loop is the innermost control loop of the overall flywheel system and, as a result, must be fast and accurate over the entire operating speed range (20,000 to 60,000 rpm) of the flywheel. The voltage applied to the motor is a high frequency PWM version of the DC bus voltage that results in the commanded fundamental value plus higher order harmonics. Most of the harmonic content is at the switching frequency and above. The higher order harmonics cause a rapid change in voltage to be applied to the motor that can result in large voltage stresses across the motor windings. In addition, the high frequency content in the motor causes sensor noise in the magnetic bearings that leads to disturbances for the bearing control. To alleviate these problems, a filter is used to present a more sinusoidal voltage to the motor/generator. However, the filter adds additional dynamics and phase lag to the motor system that can interfere with the performance of the current regulator. This paper will discuss the tuning methodology and results for the motor/generator current regulator and the impact of the filter on the control. Results at speeds up to 50,000 rpm are presented.

Kenny, Barbara H.↗

Risk-Constrained Reinforcement Learning for Inverter-Dominated Power System Controls

Here, this paper develops a risk-aware controller for grid-forming inverters (GFMs) to minimize large frequency oscillations in GFM inverter-dominated power systems. To tackle the high variability from loads/renewables, we incorporate a mean-variance risk constraint into the classical linear quadratic regulator (LQR) formulation for this problem. The risk constraint aims to bound the time-averaged cost of state variability and thus can improve the worst-case performance for large disturbances. The resulting risk-constrained LQR problem is solved through the dual reformulation to a minimax problem, by using a reinforcement learning (RL) method termed as stochastic gradient-descent with max-oracle (SGDmax). In particular, the zero-order policy gradient (ZOPG) approach is used to simplify the gradient estimation using simulated system trajectories. Numerical tests conducted on the IEEE 68-bus system have validated the convergence of our proposed SGDmax for GFM model and corroborate the effectiveness of the risk constraint in improving the worst-case performance while reducing the variability of the overall control cost.

Frequency control↗

Quantified Energy Dissipation Rates in the Terrestrial Bow Shock: Analysis Techniques and Methodology - 1.

We present a detailed outline and discussion of the analysis techniques used to compare the relevance of different energy dissipation mechanisms at collisionless shock waves. We show that the low-frequency, quasi-static fields contribute less to ohmic energy dissipation, (−j ⋅ E ) (minus current density times measured electric field), than their high-frequency counterparts. In fact, we found that high-frequency, large-amplitude (greater than 100 millivolts per meter and/or greater than 1 nanotesla) waves are ubiquitous in the transition region of collisionless shocks. We quantitatively show that their fields, through wave-particle interactions, cause enough energy dissipation to regulate the global structure of collisionless shocks. The purpose of this paper, part one of two, is to outline and describe in detail the background, analysis techniques, and theoretical motivation for our new results presented in the companion paper. The companion paper presents the results of our quantitative energy dissipation rate estimates and discusses the implications. Together, the two manuscripts present the first study quantifying the contribution that high-frequency waves provide, through wave-particle interactions, to the total energy dissipation budget of collisionless shock waves.

Terrestrial bow↗

Virtual Self-Excited Induction Generator-Based Grid-Forming Inverter Control for Robust Voltage Regulation Under Nonideal Loading

This paper presents a generator-inspired control methodology for grid-forming (GFM) inverters that deliberately emulates a self-excited induction generator so that the inverter can hold its voltage and frequency under difficult loading and severe terminal disturbances across wide voltage and frequency ranges. The design integrates a Lyapunov energy function-based inner loop to provide high bandwidth and strong disturbance rejection, and it complements this with a passivity-based argument that furnishes a coherent large-signal stability guarantee beyond small-signal limits. Analytical insights are developed via the Krylov-Bogoliubov-Mitropolsky averaging method, which reveals an intrinsic resistive droop characteristic; these closed-form relations both explain the observed dynamics and yield simple, decentralized tuning rules. The methodology is validated on a controller-hardware-in-the-loop platform and exercised in real time across balanced, unbalanced, and nonlinear loads, as well as during parallel operation. Across these scenarios, the inverter maintains balanced three-phase voltages, limits harmonic content, settles quickly with well-damped transients, and remains resilient when multiple units operate in parallel. The contributions are a self-excited-machine-inspired GFM controller with enhanced dynamic performance and robustness, a single stability rationale grounded in passivity, closed-form expressions that guide tuning, and comprehensive hardware-in-the-loop validations demonstrating effectiveness and superiority under challenging operating conditions.

24 POWER TRANSMISSION AND DISTRIBUTION↗