Search NASA⌕ Search

SEARCH · Search NASA

Results for “Flow Boiling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

The Zero Boil-Off Tank Experiment Contributions to the Development of Cryogenic Fluid Management

The Zero Boil-Off Technology (ZBOT) Experiment involves performing a small scale ISS experiment to study tank pressurization and pressure control in microgravity. The ZBOT experiment consists of a vacuum jacketed test tank filled with an inert fluorocarbon simulant liquid. Heaters and thermo-electric coolers are used in conjunction with an axial jet mixer flow loop to study a range of thermal conditions within the tank. The objective is to provide a high quality database of low gravity fluid motions and thermal transients which will be used to validate Computational Fluid Dynamic (CFD) modeling. This CFD can then be used in turn to predict behavior in larger systems with cryogens. This paper will discuss the current status of the ZBOT experiment as it approaches its flight to installation on the International Space Station, how its findings can be scaled to larger and more ambitious cryogenic fluid management experiments, as well as ideas for follow-on investigations using ZBOT like hardware to study other aspects of cryogenic fluid management.

Fluid management↗

Investigations of Physical Processes in Microgravity Relevant to Space Electrochemical Power Systems

NASA has performed physical science microgravity flight experiments in the areas of combustion science, fluid physics, material science and fundamental physics research on the International Space Station (ISS) since 2001. The orbital conditions on the ISS provide an environment where gravity driven phenomena, such as buoyant convection, are nearly negligible. Gravity strongly affects fluid behavior by creating forces that drive motion, shape phase boundaries and compress gases. The need for a better understanding of fluid physics has created a vigorous, multidisciplinary research community whose ongoing vitality is marked by the continuous emergence of new fields in both basic and applied science. In particular, the low-gravity environment offers a unique opportunity for the study of fluid physics and transport phenomena that are very relevant to management of fluid - gas separations in fuel cell and electrolysis systems. Experiments conducted in space have yielded rich results. These results provided valuable insights into fundamental fluid and gas phase behavior that apply to space environments and could not be observed in Earth-based labs. As an example, recent capillary flow results have discovered both an unexpected sensitivity to symmetric geometries associated with fluid container shape, and identified key regime maps for design of corner or wedge-shaped passive gas-liquid phase separators. In this presentation we will also briefly review some of physical science related to flight experiments, such as boiling, that have applicability to electrochemical systems, along with ground-based (drop tower, low gravity aircraft) microgravity electrochemical research. These same buoyancy and interfacial phenomena effects will apply to electrochemical power and energy storage systems that perform two-phase separation, such as water-oxygen separation in life support electrolysis, and primary space power generation devices such as passive primary fuel cell.

energy storage↗

Preliminary Tests of a Burner for Ram-Jet Applications

Preliminary tests have been made of a small burner to meet the requirements for application to supersonic ram jets. The principal requirements were taken as: (1) efficient combustion in a high-velocity air stream, (2) utilization for combustion of only a small fraction of the air passing through the unit, (3) low resistance to air flow, (4) simple construction, and (5) light weight. Tests of a small burner were carried to stream velocities of nearly 150 feet per second and fuel rates such that one-eighth to one-fourth of the total air was involved in combustion. Commercial propane was selected as the fuel since its low boiling point facilitated vaporization. Combustion which was 80 percent complete along with low aerodynamic losses was obtained by injecting the fuel evenly, prior to ignition, and allowing it to mix with the air without appreciably disturbing the stream. The pressure drop due to frictional losses around the burner and to the adjacent inside walls of the ram jet is small compared with the pressure drop due to combustion.

Huber, Paul W.↗

Tank Pressure Control Experiment: Thermal Phenomena in Microgravity

The report presents the results of the flight experiment Tank Pressure Control Experiment/Thermal Phenomena (TPCE/TP) performed in the microgravity environment of the space shuttle. TPCE/TP, flown on the Space Transportation System STS-52, was a second flight of the Tank Pressure Control Experiment (TPCE). The experiment used Freon 113 at near saturation conditions. The test tank was filled with liquid to about 83% by volume. The experiment consisted of 21 tests. Each test generally started with a heating phase to increase the tank pressure and to develop temperature stratification in the fluid, followed by a fluid mixing phase for the tank pressure reduction and fluid temperature equilibration. The heating phase provided pool boiling data from large (relative to bubble sizes) heating surfaces (0.1046 m by 0.0742 m) at low heat fluxes (0.23 to 1.16 kW/sq m). The system pressure and the bulk liquid subcooling varied from 39 to 78 kPa and 1 to 3 C, respectively. The boiling process during the entire heating period, as well as the jet-induced mixing process for the first 2 min of the mixing period, was also recorded on video. The unique features of the experimental results are the sustainability of high liquid superheats for long periods and the occurrence of explosive boiling at low heat fluxes (0.86 to 1.1 kW/sq m). For a heat flux of 0.97 kW/sq m, a wall superheat of 17.9 C was attained in 10 min of heating. This superheat was followed by an explosive boiling accompanied by a pressure spike of about 38% of the tank pressure at the inception of boiling. However, at this heat flux the vapor blanketing the heating surface could not be sustained. Steady nucleate boiling continued after the explosive boiling. The jet-induced fluid mixing results were obtained for jet Reynolds numbers of 1900 to 8000 and Weber numbers of 0.2 to 6.5. Analyses of data from the two flight experiments (TPCE and TPCE/TP) and their comparison with the results obtained in drop tower experiments suggest that as Bond number approaches zero the flow pattern produced by an axial jet and the mixing time can be predicted by the Weber number.

Hasan, Mohammad M.↗

The Zero Boil-Off Tank Experiment Ground Testing and Verification of Fluid and Thermal Performance

The Zero Boil-Off Technology (ZBOT) Experiment involves performing a small scale International Space Station (ISS) experiment to study tank pressurization and pressure control in microgravity. The ZBOT experiment consists of a vacuum jacketed test tank filled with an inert fluorocarbon simulant liquid. Heaters and thermo-electric coolers are used in conjunction with an axial jet mixer flow loop to study a range of thermal conditions within the tank. The objective is to provide a high quality database of low gravity fluid motions and thermal transients which will be used to validate Computational Fluid Dynamic (CFD) modeling. This CFD can then be used in turn to predict behavior in larger systems with cryogens. This paper will discuss the work that has been done to demonstrate that the ZBOT experiment is capable of performing the functions required to produce a meaningful and accurate results, prior to its launch to the International Space Station. Main systems discussed are expected to include the thermal control system, the optical imaging system, and the tank filling system.This work is sponsored by NASAs Human Exploration Mission Directorates Physical Sciences Research program.

Fluid management↗

Performance testing of a two-phase interface heat exchanger

This paper describes the design and performance testing of a heat exchanger which interfaces separate two-phase ammonia thermal loops. The basic design involves a tube-in-tube concept, with boiling occurring in the inner tube and condensation in the outer tube. Eight such tubes are arranged in parallel. Testing has demonstrated that up to 8.2 kW of heat may be transferred across the heat exchanger when the saturation temperature difference between the systems is 5 C. Performance of the heat exchanger is affected primarily by the mass flow rate of ammonia in the liquid supply loop.

Mccabe, M. E., Jr.↗

Experimental Studies on the Effect of Inlet Liquid Subcooling on the Chilldown Characteristics of Stainless Steel Tubes

Understanding transfer line chilldown process under microgravity is important for the efficient transfer of cryogenic propellants in space fuel depots to facilitate future long duration space missions. The present work is part of the ongoing efforts to develop and test a two-phase flow chilldown test section to study the complete chilldown process under sustained microgravity conditions onboard the International Space Station. In this study, ground-based chilldown experiments are carried out on a 60 cm long SS-316 test section with PF-5060 as the working fluid. The complete chilldown curve was obtained including the film, transition and nucleate boiling regimes along with the temperature transition points. The effect of inlet liquid subcooling on the behavior of the chilldown curves are presented. Further, the chilldown and heat flux curves are analyzed to obtain re-wetting/Leidenfrost and onset of nucleate boiling temperature transition points as well as the critical heat flux values. The effect of inlet liquid subcooling on regime-specific heat flux and heat transfer coefficients are also examined.

CFD↗

Tank Pressure Control Experiment: Thermal Phenomena in Microgravity. Video 2 of 4

The report presents the results of the flight experiment Tank Pressure Control Experiment/Thermal Phenomena (TPCE/TP) performed in the microgravity environment of the space shuttle. TPCE/TP, flown on the Space Transportation System STS-52, was a second flight of the Tank Pressure Control Experiment (TPCE). The experiment used Freon 113 at near saturation conditions. The test tank was filled with liquid to about 83 percent by volume. The experiment consisted of 21 tests. Each test generally started with a heating phase to increase the tank pressure and to develop temperature stratification in the fluid, followed by a fluid mixing phase for the tank pressure reduction and fluid temperature equilibration. The heating phase provided pool boiling data from large (relative to bubble sizes) heating surfaces (0.1046 m by 0.0742 m) at low heat fluxes (0.23 to 1.16 kW/m(exp 2)). The system pressure and the bulk liquid subcooling varied from 39 to 78 kPa and 1 to 3 deg C, respectively. The boiling process during the entire heating period, as well a jet-induced mixing process for the first 2 min. of the mixing period, was also recorded on video. Analyses of data from the two flight experiments (TPCE and TPCE/TP) and their comparison with the results obtained in drop tower experiments suggest that as Bond number approaches zero the flow pattern produced by an axial jet and the mixing time can be predicted by the Weber number. This is video 2 of 4.

Source record↗

Tank Pressure Control Experiment: Thermal Phenomena in Microgravity. Video 4 of 4

The report presents the results of the flight experiment Tank Pressure Control Experiment/Thermal Phenomena (TPCE/TP) performed in the microgravity environment of the space shuttle. TPCE/TP, flown on the Space Transportation System STS-52, was a second flight of the Tank Pressure Control Experiment (TPCE). The experiment used Freon 113 at near saturation conditions. The test tank was filled with liquid to about 83 percent by volume. The experiment consisted of 21 tests. Each test generally started with a heating phase to increase the tank pressure and to develop temperature stratification in the fluid, followed by a fluid mixing phase for the tank pressure reduction and fluid temperature equilibration. The heating phase provided pool boiling data from large (relative to bubble sizes) heating surfaces (0.1046 m by 0.0742 m) at low heat fluxes (0.23 to 1.16 kW/m(exp 2)). The system pressure and the bulk liquid subcooling varied from 39 to 78 kPa and 1 to 3 deg C, respectively. The boiling process during the entire heating period, as well a jet-induced mixing process for the first 2 min. of the mixing period, was also recorded on video. Analyses of data from the two flight experiments (TPCE and TPCE/TP) and their comparison with the results obtained in drop tower experiments suggest that as Bond number approaches zero the flow pattern produced by an axial jet and the mixing time can be predicted by the Weber number. This is video 4 of 4.

Source record↗

Tank Pressure Control Experiment: Thermal Phenomena in Microgravity. Video 1 of 4

The report presents the results of the flight experiment Tank Pressure Control Experiment/Thermal Phenomena (TPCE/TP) performed in the microgravity environment of the space shuttle. TPCE/TP, flown on the Space Transportation System STS-52, was a second flight of the Tank Pressure Control Experiment (TPCE). The experiment used Freon 113 at near saturation conditions. The test tank was filled with liquid to about 83 percent by volume. The experiment consisted of 21 tests. Each test generally started with a heating phase to increase the tank pressure and to develop temperature stratification in the fluid, followed by a fluid mixing phase for the tank pressure reduction and fluid temperature equilibration. The heating phase provided pool boiling data from large (relative to bubble sizes) heating surfaces (0.1046 m by 0.0742 m) at low heat fluxes (0.23 to 1.16 kW/m(exp 2)). The system pressure and the bulk liquid subcooling varied from 39 to 78 kPa and 1 to 3 deg C, respectively. The boiling process during the entire heating period, as well a jet-induced mixing process for the first 2 min. of the mixing period, was also recorded on video. Analyses of data from the two flight experiments (TPCE and TPCE/TP) and their comparison with the results obtained in drop tower experiments suggest that as Bond number approaches zero the flow pattern produced by an axial jet and the mixing time can be predicted by the Weber number. This is video 1 of 4.

Source record↗

Tank Pressure Control Experiment: Thermal Phenomena in Microgravity. Video 3 of 4

The report presents the results of the flight experiment Tank Pressure Control Experiment/Thermal Phenomena (TPCE/TP) performed in the microgravity environment of the space shuttle. TPCE/TP, flown on the Space Transportation System STS-52, was a second flight of the Tank Pressure Control Experiment (TPCE). The experiment used Freon 113 at near saturation conditions. The test tank was filled with liquid to about 83 percent by volume. The experiment consisted of 21 tests. Each test generally started with a heating phase to increase the tank pressure and to develop temperature stratification in the fluid, followed by a fluid mixing phase for the tank pressure reduction and fluid temperature equilibration. The heating phase provided pool boiling data from large (relative to bubble sizes) heating surfaces (0.1046 m by 0.0742 m) at low heat fluxes (0.23 to 1.16 kW/m(exp 2)). The system pressure and the bulk liquid subcooling varied from 39 to 78 kPa and 1 to 3 deg C, respectively. The boiling process during the entire heating period, as well a jet-induced mixing process for the first 2 min. of the mixing period, was also recorded on video. Analyses of data from the two flight experiments (TPCE and TPCE/TP) and their comparison with the results obtained in drop tower experiments suggest that as Bond number approaches zero the flow pattern produced by an axial jet and the mixing time can be predicted by the Weber number. This is video 3 of 4.

Source record↗

Helium jet dispersion to atmosphere

On the event of loss of vacuum guard of superinsulated helium dewar, high rate of heat transfer into the tank occurs. The rapid boiling of liquid helium causes the burst disk to rupture at four atmospheres and consequently the helium passes to the atmosphere through vent lines. The gaseous helium forms a vertical buoyant jet as it exits the vent line into a stagnant environment. Characterization of the gaseous jet is achieved by detailed analysis of the axial and radial dependence of the flow parameters.

Khan, Hasna J.↗

Precision pointing thrustor.

A satellite experiment to test the predicted relativistic precession of a gyroscope moving through a gravitational field has been under development at Stanford University for a number of years. The instruments will be located in a liquid helium bath to insure dimensional stability and to permit using superconducting types of circuitry for readout of the gyro orientation. Heat leaks in the system cause the helium to boil and the resultant helium gas is used for attitude control. The principal subject of the paper is the design and experimental evaluation of an electromagnetically actuated differential thrustor which was built and tested at Stanford University. The results are unique because most propulsion systems operate on-off in order to utilize propellant efficiently. In this case, the gas must flow continually to provide cooling, and the requirements are primarily for low power, small volume, and high reliability.

Bull, J. S.↗

System design and analysis of thermal power dispatch systems for boiling water reactors

Nuclear power plants are crucial to meeting net zero emission goals and achieving energy sustainability. Integrating these plants with clean energy technologies such as high-temperature steam electrolysis (HTSE) may improve the efficiency and economic competitiveness of these plants. Here, the current study investigates the design and operation of a thermal power dispatch (TPD) system for coupling boiling water reactors (BWRs) to HTSE plants. The TPD system extracts a portion of the steam from the reactor’s main steam line and transfers its thermal energy to an HTSE plant through a power transport loop. A TPD system for 5 % steam extraction has been designed and the system performance during steady and transient operations has been analyzed. The TPD system dispatched a total of 197 MW thermal energy to the HTSE plant under nominal design conditions. Saturated steam at 7.17 MPa from the BWR plant was condensed and subcooled to a temperature of 168 °C, while a mass flow rate of 91.1 kg/s of superheated steam was dispatched to the HTSE plant. Furthermore, the system performance during transient operation showed a continuous transition from the initial hot standby mode to the nominal power dispatch level. The transient simulation results emphasized the importance of investigating component level performance for the TPD system design. The current results will guide future works on the development of integrated energy systems for hydrogen production or process heat applications.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Adhesive evaluation of thin films of LARC-TPI and LARC-TPI with 5 mol % ODA

A commercially available LARC-TPI film and an experimentally prepared film of LARC-TPI with 5 mol % of 4,4'-oxydianiline (ODA), designated as LARC-TPI/ODA in the report, supplied by Mitsui Toatsu Chemicals, Incorporated (MTCI), Japan, were evaluated as thermoplastic adhesive films for bonding Ti-6Al-4V. The LARC-TPI/ODA had been shown by MTCI to possess more flow than thermoplastic LARC-TPI and was, therefore, evaluated and compared to the LARC-TPI. Lap shear strength was used to evaluate the materials as adhesives. They were characterized after fracture by determining the glass transition temperature, Tg. The mode of failure was also reported. Thermal exposure at 204C for 500 and 1000 hrs and a 72-hour water-boil were conducted on lap shear specimens prepared with the two adhesive films. Lap shear tests were conducted at RT, 177C, 204C, and 232C before and after exposures.

Progar, D. J.↗

Performance Comparisons for Artificially Propagated and Wild Pacific Lamprey Juveniles and Larvae

ABSTRACT Artificially propagated Pacific lamprey ( Entosphenus tridentatus ) are produced for restoration and for use in dam passage studies to reduce the demand for wild fish. Such uses require that animals are representative of their wild counterparts. Previous work indicated that this is true for Pacific lamprey larvae and juveniles reared in the hatchery with respect to the length of sustained swimming. However, more subtle differences in behaviour and performance that lamprey need to survive have not been assessed. In this study, artificially propagated and wild fish were compared in laboratory tests under no‐flow conditions to examine light avoidance, burrowing speed, burst swim speed, volitional routine swim speed and time to come to rest. Most larvae burrowed in less than a minute, and we found highly significant differences ( p < 0.001) between artificially propagated and wild larvae burrowing times, a critical escape behaviour. This could have implications for studies of larval entrainment at irrigation diversion canals or in turbine boils at dams. Interestingly, all of the wild juveniles tested came to rest quickly after introduction to the chamber (1.5 min), while artificially propagated lamprey swam robotically near the surface and 48% did not come to rest in the first 10 min (median time to rest = 9.5 min). In contrast, wild juveniles quickly (median = 1.47 min) sought areas near the tank bottom and attached strongly with their oral disc. Such behavioural differences could have important survival consequences for artificially propagated lamprey as they approach turbine intakes, bypass screens and irrigation diversion headgates. This study highlights the need to conduct behavioural assays that examine subtleties of fish behaviour that can be missed with traditional swim tunnel comparisons.

Frick, Kinsey [Fish Ecology Division, Northwest Fi↗

A microgravity boiling and convective condensation experiment

A boiling and condensing test article consisting of two straight tube boilers, one quartz and one stainless steel, and two 1.5 m long glass-in-glass heat exchangers, on 6 mm ID and one 10 mm ID, was flown on the NASA KC-135 0-G aircraft. Using water as the working fluid, the 5 kw boiler produces two phase mixtures of varying quality for mass flow rates between 0.005 and 0.1 kg/sec. The test section is instrumented at eight locations with absolute and differential pressure transducers and thermocouples. A gamma densitometer is used to measure void fraction, and high speed photography records the flow regimes. A three axis accelerometer provides aircraft acceleration data (+ or - 0.01G). Data are collected via an analog-to-digital conversion and data acquisition system. Bubbly, annular, and slug flow regimes were observed in the test section under microgravity conditions. Flow oscillations were observed for some operating conditions and the effect of the 2-G pullout prior to the 0-G period was observed by continuously recording data throughout the parabolas. A total fo 300 parabolas was flown.

Kachnik, Leo↗

Correlation of cylinder-head temperatures and coolant heat rejections of a multicylinder, liquid-cooled engine of 1710-cubic-inch displacement

Data obtained from an extensive investigation of the cooling characteristics of four multicylinder, liquid-cooled engines have been analyzed and a correlation of both the cylinder-head temperatures and the coolant heat rejections with the primary engine and coolant variables was obtained. The method of correlation was previously developed by the NACA from an analysis of the cooling processes involved in a liquid-cooled-engine cylinder and is based on the theory of nonboiling, forced-convection heat transfer. The data correlated included engine power outputs from 275 to 1860 brake horsepower; coolant flows from 50 to 320 gallons per minute; coolants varying in composition from 100 percent water to 97 percent ethylene glycol and 3 percent water; and ranges of engine speed, manifold pressure, carburetor-air temperature, fuel-air ratio, exhaust-gas pressure, ignition timing, and coolant temperature. The effect on engine cooling of scale formation on the coolant passages of the engine and of boiling of the coolant under various operating conditions is also discussed.

Lundin, Bruce T↗