Search NASA⌕ Search

SEARCH · Search NASA

Results for “Flow Measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Blowing Flap Experiment: PIV Measurements

PIV measurements of the flow in the region of a flap side edge are presented for several flap configurations. The test model is a NACA 63(sub 2)-215 Hicks Mod-B main element airfoil with a half-span Fowler flap. Air is blown from small slots located along the flap side edge on either the top, bottom or side surfaces. The test set up is described and flow measurements for a baseline and three blowing flap configurations are presented. The effects that the flap tip jets have on the structure of the flap side edge flow are discussed for each of the flap configurations tested. The results indicate that blowing air from a slot located along the top surface of the flap greatly weakened the top vortex system and pushed it further off the top surface. Blowing from the bottom flap surface kept the strong side vortex further outboard while blowing from the side surface only strengthened the flap vortex system. It is concluded that blowing from the top or bottom surfaces of the flap may lead to a reduction of flap side edge noise.

Hutcheson, Florence V.↗

PIV Measurements on a Blowing Flap

PIV measurements of the flow in the region of a flap side edge are presented for several blowing flap configurations. The test model is a NACA 63(sub 2)-215 Hicks Mod-B main-element airfoil with a half-span Fowler flap. Air is blown from small slots located along the flap side edge on either the top, bottom or side surfaces. The test set up is described and flow measurements for a baseline and three blowing flap configurations are presented. The effects that the flap tip jets have on the structure of the flap side edge flow are discussed for each of the flap configurations tested. The results indicate that blowing air from a slot located along the top surface of the flap greatly weakened the top vortex system and pushed it further off the top surface. Blowing from the bottom flap surface kept the strong side vortex further outboard while blowing from the side surface only strengthened the vortex system or accelerated the merging of the side vortex to the flap top surface. It is concluded that blowing from the top or bottom surfaces of the flap may lead to a reduction of flap side edge noise.

Hutcheson, Florence V.↗

Rayleigh Scattering Measurements in NASA Lewis Wind Tunnels

Two applications of Rayleigh scattering for measuring flow parameters in wind tunnels are described. The first is the measurement of one velocity component and static temperature in the vicinity of a 12 % scale advanced short takeoff and vertical landing (ASTOVL) aircraft model in the Lewis 9 ft by 15 ft low speed wing tunnel. The model was equipped with high temperature and high pressure air supplies to simulate lift nozzles and suction systems to simulate engine inlets. The second application is a feasibility study to measure flow properties in a 4 inch by 10 inch supersonic wind tunnel This technique uses an injection seeded, frequency doubled Nd:YAG laser tuned to an absorption band of iodine.

Seasholtz, Richard↗

Achromatic Emission Velocity Measurements in Luminous Flows

A new velocity measurement instrument for luminous flows was developed by Science Research Laboratory for NASA. The SIEVE (Segmented Image Emission VElocimeter) instrument uses broadband light emitted by the flow for the velocity measurement. This differs from other velocimetry techniques in that it does not depend on laser illumination and/or light scattering from particles in the flow. The SIEVE is a passive, non-intrusive diagnostic. By moving and adjusting the imaging optics, the SIEVE can provide three-dimensional mapping of a flow field and determine turbulence scale size. A SIEVE instrument was demonstrated on an illuminated rotating disk to evaluate instrument response and noise and on an oxy-acetylene torch to measure flame velocities. The luminous flow in rocket combustors and plumes is an ideal subject for the SIEVE velocity measurement technique.

Schneider, S. J.↗

Investigation of the Elliptic Flow Fluctuations of the Identified Particles Using the a Multi-Phase Transport Model

A Multi-Phase Transport (AMPT) model is used to study the elliptic flow fluctuations of identified particles using participant and spectator event planes. The elliptic flow measured using the first order spectator event plane is expected to give the elliptic flow relative to the true reaction plane which suppresses the flow fluctuations. However, the elliptic flow measured using the second-order participant plane is expected to capture the elliptic flow fluctuations. Our study shows that the first order spectator event plane could be used to study the elliptic flow fluctuations of the identified particles in the AMPT model. The elliptic flow fluctuations magnitude shows weak particle species dependence and transverse momentum dependence. Such observation will have important implications for understanding the source of the elliptic flow fluctuations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Three-Dimensional Structure and Modeling of a Normal Bifurcated Shock Train from Experimental Measurements

An asymmetric, bifurcated normal shock train in a Mach 2 constant area, rectangular duct is investigated in the University of Michigan Direct Connect Isolator facility. High-speed schlieren imaging, wall static pressure measurements, surface oil flow visualization, and particle image velocimetry of a shock train are synthesized into a three-dimensional representation of shock train structure. This visualization is then used to inform the underlying flow physics of the distributed fluid dynamical processes along the structure. The detailed, three-dimensional morphology of the flow profile entering the shock train is shown to have a significant impact on the separated flow morphology of the shock train. This results in skewed supersonic core flow with alternating separation bubbles in the surrounding boundary layers. Finally, the efficacy of the prevailing pseudo-shock models in the literature is analyzed with the support of the available flow measurements. None are found to simultaneously model both the pressure and streamwise Mach number profile of the UMDCI pseudo-shock.

Hypersonics↗

Application of Circulation Control Technology to Airframe Noise Reduction

This report is a summary of the work performed by Georgia Tech Research Institute (GTRI) under NASA Langley Grant NAG-1-2146, which was awarded as a part of NASA's Breakthrough Innovative Technologies (BIT) initiative. This was a three-year program, with a one-year no-cost extension. Each year's study has been an integrated effort consisting of computational fluid dynamics, experimental aerodynamics, and detailed noise and flow measurements. Year I effort examined the feasibility of reducing airframe noise by replacing the conventional wing systems with a Circulation Control Wing (CCW), where steady blowing was used through the trailing edge of the wing over a Coanda surface. It was shown that the wing lift increases with CCW blowing and indeed for the same lift, a CCW wing was shown to produce less noise. Year 2 effort dealt with a similar study on the role of pulsed blowing on airframe noise. The main objective of this portion of the study was to assess whether pulse blowing from the trailing edge of a CCW resulted in more, less, or the same amount of radiated noise to the farfield. Results show that a reduction in farfield noise of up to 5 dB is measured when pulse flow is compared with steady flow for an equivalent lift configuration. This reduction is in the spectral region associated with the trailing edge jet noise. This result is due to the unique advantage that pulsed flow has over steady flow. For a range of frequencies, more lift is experienced with the same mass flow as the steady case. Thus, for an equivalent lift and slot height, the pulsed system can operate at lower jet velocities, and hence lower jet noise. The computational analysis showed that for a given time-averaged mass flow rate, pulsed jets give a higher value of C(sub l) and a higher L/D than equivalent steady jets. This benefit is attributable to higher instantaneous jet velocities, and higher instantaneous C(sub mu) values for the pulsed jet. Pulsed jet benefits increase at higher frequencies. However, these advantages are somewhat offset by the unsteadiness in the loads, which will cause structural vibrations and fatigue. Additional studies must be done, perhaps with multiple jets on the upper and lower surfaces, to smooth out the fluctuations in lift while retaining the benefits. The rest of the effort was devoted to examining ways of reducing flap edge noise by blowing air through a Coanda nozzle over a rounded tip of the flap. In this case, we were successful in moving the tip vortex away from the tip, but the device producing the blowing was noisy and we were unable to examine the noise benefits, although we believe that the movement of the tip vortex far from the tip should provide noise benefits. It should be noted that in an effort to understand the fluid dynamics and the aeroacoustics of a jet blowing over a Coanda surface, we also carried out a very extensive study of the high aspect ratio slot jets. A first-ever set of far-field noise spectra were measured for jets exhausting from slots with aspect ratios in the range 100 to 3000. Parallel measurements of velocity profiles, length scales and convection velocities were measured to understand the noise generation of high aspect ratio jets. Attempts were also made to develop jet noise prediction schemes for such jets. Much of the work done under this effort has been described in five conference papers and two doctoral theses. The first year s work on the use of steady blowing was described in two AIAA papers presented at the 2001 AIAA Aerospace Sciences Meeting in Reno. Subsequent work was presented at the 9th AIMCEAS Aeroacoustics Conference and Exhibit held at Hilton Head May 12-13. Another paper is to be presented at the 2004 AIAA Aerospace Sciences Meeting in Reno in January 2004. All six papers are included with this report as Appendices. The bulk of the experimental work done in an effort to produce a pulsed flow that is free of upstream noise is also attached as an Appendix.

Ahuja, K. K.↗

Raman Doppler velocimetry - A unified approach for measuring molecular flow velocity, temperature, and pressure

Molecular flow velocity (one component), translational temperature, and static pressure of N2 are measured in a supersonic wind tunnel using inverse Raman spectroscopy. For velocity, the technique employs the large Doppler shift exhibited by the molecules when the pump and probe laser beams are counterpropagating (backward scattering). A retrometer system is employed to yield an optical configuration insensitive to mechanical vibration, which has the additional advantage of simultaneously obtaining both the forward and backward scattered spectra. The forward and backward line breadths and their relative Doppler shift can be used to determine the static pressure, translational temperature, and molecular flow velocity. A demonstration of the technique was performed in a continuous airflow supersonic wind tunnel in which data were obtained under the following conditions: (1) free-stream operation at five set Mach number levels over the 2.50-4.63 range; (2) free-stream operation over a range of Reynolds number (at a fixed Mach number) to vary systematically the static pressure; and (3) operation in the flow field of a simple aerodynamic model to assess beam steering effects in traversing the attached shock layer.

Exton, R. J.↗

Hypersonic-helium-flow-field measurements with the resonant Doppler velocimeter

A low density of sodium atoms seeded into a hypersonic helium flow is used to quantitatively determine flow-field properties. By observing fluorescence from a point as a single-mode dye laser is tuned through the sodium D2 line, the absorption profile may be found. This profile is fitted to a properly weighted sum of Voigt functions to yield the velocity, temperature, and pressure at the observation point. The fluorescence is strong enough to use this technique for qualitative flow-field visualization.

Zimmermann, M.↗

Blood flow imaging by optimal matching of computational fluid dynamics to 4D-flow data

Three-dimensional, time-resolved blood flow measurement (4D-flow) is a powerful research and clinical tool, but improved resolution and scan times are needed. Therefore, this study aims to (1) present a postprocessing framework for optimization-driven simulation-based flow imaging, called 4D-flow High-resolution Imaging with a priori Knowledge Incorporating the Navier-Stokes equations and the discontinuous Galerkin method (4D-flow HIKING), (2) investigate the framework in synthetic tests, (3) perform phantom validation using laser particle imaging velocimetry, and (4) demonstrate the use of the framework in vivo. An optimizing computational fluid dynamics solver including adjoint-based optimization was developed to fit computational fluid dynamics solutions to 4D-flow data. Synthetic tests were performed in 2D, and phantom validation was performed with pulsatile flow. Reference velocity data were acquired using particle imaging velocimetry, and 4D-flow data were acquired at 1.5 T. In vivo testing was performed on intracranial arteries in a healthy volunteer at 7 T, with 2D flow as the reference. Results Synthetic tests showed low error (0.4%-0.7%). Phantom validation showed improved agreement with laser particle imaging velocimetry compared with input 4D-flow in the horizontal (mean -0.05 vs -1.11 cm/s, P < .001; SD 1.86 vs 4.26 cm/s, P < .001) and vertical directions (mean 0.05 vs -0.04 cm/s, P = .29; SD 1.36 vs 3.95 cm/s, P < .001). In vivo data show a reduction in flow rate error from 14% to 3.5%. Phantom and in vivo results from 4D-flow HIKING show promise for future applications with higher resolution, shorter scan times, and accurate quantification of physiological parameters.

4D-flow MRI↗

Conceptual design of a Doppler spectrometer for 102 m/s cross-field flows in tokamak divertors

The cross-field transport in the scrape-off-layers (SOLs) and divertors in tokamaks is of a similar size to the poloidal component of the parallel flow, thereby significantly impacting the plasma transport there. However, its direct observation has been challenging because the drift velocity (102–103 m/s) is significantly below the detection limit of conventional diagnostics. To realize cross-field ion flow measurement, a variety of systematic uncertainties in the system must be narrowed down. Here, we develop a conceptual design of the Doppler spectrometry that enables us to measure the impurity flows with 102-m/s accuracy based on an in situ wavelength-calibration technique developed in the astrophysics field, the iodine-cell method. We discuss its properties and applicability. In particular, the scaling relation between wavelength accuracy and various spectroscopic parameters is newly presented, which suggests the high importance of the wavelength resolution of the system. Based on transport simulations for the JT-60SA divertor, the feasibility of the system is assessed.

Fujii, Keisuke↗

Fluid flow meter for measuring the rate of fluid flow in a conduit

A tube fluid flow rate meter consists of a reservoir divided by flexible diaphragm into two separate isolated compartments. The incoming and outgoing tubes open into the compartments. The orifice is sized to allow maximum tube fluid flow. Opposing compression springs are secured within the two compartments on opposite sides of the orifice to maintain orifice position when the tube fluid pressure is zero. A tapered element is centered in, and extends through the orifice into the compartment, leaving an annular opening between the element and the perimeter of the oriface. The size varies as the diaphragm flexes with changes in the tube fluid pressure to change the fluid flow through the opening. The light source directs light upon the element which in turn scatters the light through the opening into the compartment. The light detector in the compartment senses the scattered light to generate a signal indicating the amount of fluid.

White, P. R.↗

Interferometric data for a shock-wave/boundary-layer interaction

An experimental study of the axisymmetric shock-wave / boundary-layer strong interaction flow generated in the vicinity of a cylinder-cone intersection was conducted. The study data are useful in the documentation and understanding of compressible turbulent strong interaction flows, and are part of a more general effort to improve turbulence modeling for compressible two- and three-dimensional strong viscous/inviscid interactions. The nominal free stream Mach number was 2.85. Tunnel total pressures of 1.7 and 3.4 atm provided Reynolds number values of 18 x 10(6) and 36 x 10(6) based on model length. Three cone angles were studied giving negligible, incipient, and large scale flow separation. The initial cylinder boundary layer upstream of the interaction had a thickness of 1.0 cm. The subsonic layer of the cylinder boundary layer was quite thin, and in all cases, the shock wave penetrated a significant portion of the boundary layer. Owing to the thickness of the cylinder boundary layer, considerable structural detail was resolved for the three shock-wave / boundary-layer interaction cases considered. The primary emphasis was on the application of the holographic interferometry technique. The density field was deduced from an interferometric analysis based on the Able transform. Supporting data were obtained using a 2-D laser velocimeter, as well as mean wall pressure and oil flow measurements. The attached flow case was observed to be steady, while the separated cases exhibited shock unsteadiness. Comparisons with Navier-Stokes computations using a two-equation turbulence model are presented.

Dunagan, Stephen E.↗

Fluid dynamics and low gravity effects of chemical vapor deposition

Based on the comparison between experimental data and numerical results for the growth of GaAs from TMGa, it was shown that 3D simulations are necessary to simulate rectangular CVD reactors even when operated under subcritical (Ra) conditions. The important points found are summarized in the three attached reprints. The experimental studies of mixed convection in horizontal channels have shown three regimes of high Ra (22,220) number flows. At Re = 18.5, the rolls develop very quickly, significantly modulating the axial velocity even before it reaches the beginning of the hot plate. A few centimeters downstream, the velocities become asymmetric about the vertical centerplane and at x = 12 cm, become unsteady. These asymmetries were predicted theoretically, but experimental evidence has not been published prior to this work. At Re = 36, the axial velocity is only slightly modified at x = 0. Although the flow remains steady and symmetric about the vertical centerplane, there is a small spatial oscillation in the velocities over the length of the channel. The period of this oscillation was around 5 cm. At Re = 54, the longitudinal rolls developed smoothly over a length of 30 cm, with no asymmetries, unsteadiness, or spatial oscillations. Comparison of numerical simulations of these flows to experiments has revealed the importance and difficulty of setting proper thermal boundary conditions on the sidewalls. Calculated flows and experimentally measured flows showed very similar profiles, but at different axial locations, with the rolls developing more rapidly in the experiments. This is directly attributable to partially conducting sidewalls of the apparatus being hotter in the entrance section than the adiabatic walls of the simulations. A thorough comparison of the experimental data and numerical results for a variety of sidewall boundary conditions is in preparation.

Nyce, Thomas A.↗

Capacitance probe for fluid flow and volume measurements

Method and apparatus for making measurements on fluids are disclosed, including the use of a capacitive probe for measuring the flow volume of a material within a flow stream. The capacitance probe has at least two elongate electrodes and, in a specific embodiment of the invention, has three parallel elongate electrodes with the center electrode being an extension of the center conductor of a co-axial cable. A conductance probe is also provided to provide more accurate flow volume data in response to conductivity of the material within the flow stream. A preferred embodiment of the present invention provides for a gas flow stream through a microgravity environment that allows for monitoring a flow volume of a fluid sample, such as a urine sample, that is entrained within the gas flow stream.

Arndt, G. Dickey↗