Search NASA⌕ Search

SEARCH · Search NASA

Results for “Gamma Scan”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

SU-F-T-513: Dosimetric Validation of Spatially Fractionated Radiotherapy Using Gel Dosimetry

Purpose: Spatially fractionated radiation therapy, also known as GRID therapy, is used to treat large solid tumors by irradiating the target to a single dose of 10–20Gy through spatially distributed beamlets. We have investigated the use of a 3D gel for dosimetric characterization of GRID therapy. Methods: GRID therapy is an external beam analog of volumetric brachytherapy, whereby we produce a distribution of hot and cold dose columns inside the tumor volume. Such distribution can be produced with a block or by using a checker-like pattern with MLC. We have studied both types of GRID delivery. A cube shaped acrylic phantom was filled with polymer gel and served as a 3D dosimeter. The phantom was scanned and the CT images were used to produce two plans in Pinnacle, one with the grid block and one with the MLC defined grid. A 6MV beam was used for the plan with a prescription of 1500cGy at dmax. The irradiated phantom was scanned in a 3T MRI scanner. Results: 3D dose maps were derived from the MR scans of the gel dosimeter and were found to be in good agreement with the predicted dose distribution from the RTP system. Gamma analysis showed a passing rate of 93% for 5% dose and 2mm DTA scoring criteria. Both relative and absolute dose profiles are in good agreement, except in the peripheral beamlets where the gel measured slightly higher dose, possibly because of the changing head scatter conditions that the RTP is not fully accounting for. Our results have also been benchmarked against ionization chamber measurements. Conclusion: We have investigated the use of a polymer gel for the 3D dosimetric characterization and evaluation of GRID therapy. Our results demonstrated that the planning system can predict fairly accurately the dose distribution for GRID type therapy.

60 APPLIED LIFE SCIENCES↗

NDE Technology Engineering Program for Hanford DST Non-Visual Volumetric Inspection Technology: Phase II RAVIS Radiation Tolerance Test Report

This test report provides the results of radiation tolerance robustness testing that was performed on samples of robotic components and an ultrasonic guided wave air-slot sensor that represent components/sub-systems of the Robotic Air-slot Volumetric Inspection System (RAVIS) that has been engineered for volumetric inspection of Hanford tank bottom plates via under-tank refractory pad air-slots. The specific components tested for 1) functionality during active irradiation and 2) tolerance to cumulative radiation dose (until failure or upon reaching a cumulative dose test limit) were: • four samples each of a printed circuit board (PCB) and direct current (DC) motor, which are robotic components, and • 26 ultrasonic piezoelectric elements (samples) inside an air-slot sensor. The robotic components are part of the RAVIS air-slot inspection crawler drive control system that is responsible for remote communication with and actuation of the air-slot inspection crawler. The failure of either of these components during under-tank deployment would require manual retrieval via the crawler’s tether, which risks damage to the robot/refractory/tank. Preemptive replacement of the components at appropriately conservative dose/time intervals informed by failure dose would reduce the likelihood of under-tank failure. The components were included in radiation tolerance testing to quantify their failure doses to inform replacement intervals. The air-slot sensor is responsible for collecting ultrasonic inspection data (scan images) for the tank bottom plates during under-tank deployment. Compromised signal quality due to elevated noise levels caused by gamma radiation would compromise inspection performance. The air-slot sensor was included in radiation tolerance testing to quantify the impact of active irradiation on sensor signal quality. The irradiation and in-situ functional tests of the PCBs, DC motors and air-slot sensor took place in June and July 2020 at the Pacific Northwest National Laboratory. Testing was performed at a gamma dose rate near 300 rad/hr., which, in the absence of under-tank dose rate data, has been conservatively estimated to be the upper-bound dose rate beneath the primary tanks at Hanford. Irradiation took place at elevated temperatures of 150-200°F to determine failure doses that reflect the compounding effects of gamma radiation and heat. The test results revealed: • The DC motors can tolerate being actively irradiated at the high dose rate at 200°F and can tolerate a cumulative dose of 300,000 rad, that which would be incurred after 5 years of service at the 300 rad/hr dose rate. The component therefore meets minimum and preferred radiation tolerance and lifecycle requirements for robotic components. • The air-slot sensor can tolerate being actively irradiated at the high dose rate at 150°F and can tolerate a cumulative dose of 60,000 rad, that which would be incurred after 1 year of service at the 300 rad/hr dose rate. The sensor therefore meets minimum radiation tolerance and lifecycle requirements. • The PCB can tolerate being actively irradiated at the high dose rate, but can only tolerate a cumulative dose of 19,000 rad at 150-200°F. The PCB does not meet minimum radiation tolerance and lifecycle requirements; however, because the component is considered replaceable, it can be replaced before a cumulative dose of 19,000 rad is reached, determined through either monitoring with a dosimeter or scheduled time intervals that are calculated based on conservative estimates of under-tank dose rates.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Positron annihilation radiation from the galactic center region

Measurements of 0.511 MeV radiation from the vicinity of the galactic center performed by the high resolution gamma ray spectrometer aboard the HEAO 3 spacecraft are discussed. The spectrometer is described and an exploded view of it exhibited, and scans in the 50-244 keV region as well as 0.511 MeV are shown. The intensity from the Crab nebula remained constant while that of the Cygnus source increased considerably, and there was a decrease in the radiation from the vicinity of the galactic center. The flux emanating from the center implies an annihilation rate of 10 to the 43rd per second. The apparent time variation and the spatial extent observed tend to limit the source to a single object and the annihilation region to a size less than about one light year.

Jacobson, A. S.↗

Measurements of atmospheric nitric oxide from Nimbus 7 SBUV ultraviolet spectral scan data

Results are given of SBUV (solar backscattered ultraviolet instrument) measurements from Nimbus 7, when - one day per month - it is operated in a spectral scan mode, scanning from 160 nm to 400 nm in 0.2-nm steps. By measuring the intensity of a series of nitric oxide (NO) gamma band fluorescence features in this wavelength range, it has been possible to estimate the amount of NO in the upper stratosphere and mesosphere. The background of atmospherically scattered sunlight normally masks the much weaker NO gamma band emission, but these emission features are discriminated by subtracting a synthetic spectrum calculated for a model atmosphere that includes only Rayleigh scattering and absorption by ozone and oxygen. The resulting difference plot clearly reveals features resulting from processes not included in the simple model, such as NO gamma band emission. Nitric oxide is inferred by measuring the absolute intensity of various bands relative to the adjacent background and relating this intensity to total NO above an altitude determined by the backscattering contribution function for that band. NO observations near the solstice and at various latitudes are reported.

Mcpeters, R. D.↗

Characterization and use of a 2D-array of ion chambers for brachytherapy dosimetric quality assurance

The two-dimensional (2D) ionization chamber array MatriXX Evolution is one of the 2D ionization chamber arrays developed by IBA Dosimetry (IBA Dosimetry, Germany) for megavoltage real-time absolute 2D dosimetry and verification of intensity-modulated radiation therapy (IMRT). The purpose of this study was to (1) evaluate the performance of ion chamber array for submegavoltage range brachytherapy beam dose verification and quality assurance (QA) and (2) use the end-to-end dosimetric evaluation that mimics a patient treatment procedure and confirm the primary source strength calibration agrees in both the treatment planning system (TPS) and treatment delivery console computers. The dose linearity and energy dependence of the 2D ion chamber array was studied using kilovoltage X-ray beams (100, 180 and 300 kVp). The detector calibration factor was determined using 300 kVp X-ray beams so that we can use the same calibration factor for dosimetric verification of high-dose-rate (HDR) brachytherapy. The phantom used for this measurement consists of multiple catheters, the IBA MatriXX detector, and water-equivalent slab of RW3 to provide full scattering conditions. The treatment planning system (TPS) (Oncentra brachy version 3.3, Nucletron BV, Veenendaal, the Netherlands) dose distribution was calculated on the computed tomography (CT) scan of this phantom. The measured and TPS calculated distributions were compared in IBA Dosimetry OmniPro-I'mRT software. The quality of agreement was quantified by the gamma ({gamma}) index (with 3% delta dose and distance criterion of 2 mm) for 9 sets of plans. Using a dedicated phantom capable of receiving 5 brachytherapy intralumenal catheters a QA procedure was developed for end-to-end dosimetric evaluation for routine QA checks. The 2D ion chamber array dose dependence was found to be linear for 100-300 kVp and the detector response (k{sub user}) showed strong energy dependence for 100-300 kVp energy range. For the Ir-192 brachytherapy HDR source, dosimetric evaluation k{sub user} factor determined by photon beam of energy of 300 kVp was used. The maximum mean difference between ion chamber array measured and TPS calculated was 3.7%. Comparisons of dose distribution for different test plans have shown agreement with >94.5% for {gamma} {<=}1. Dosimetric QA can be performed with the 2D ion chamber array to confirm primary source strength calibration is properly updated in both the TPS and treatment delivery console computers. The MatriXX Evolution ionization chamber array has been found to be reliable for measurement of both absolute dose and relative dose distributions for the Ir-192 brachytherapy HDR source.

61 RADIATION PROTECTION AND DOSIMETRY↗

Electron channeling contrast imaging studies of nonpolar nitrides using a scanning electron microscope

Threading dislocations, stacking faults, and associated partial dislocations significantly degrade the optical and electrical properties of materials such as non-polar III-nitride semiconductor thin films. Stacking faults are generally difficult to detect and quantify with existing characterization techniques. We demonstrate the use of electron channeling contrast imaging in the scanning electron microscope to non-destructively reveal basal plane stacking faults terminated by partial dislocations in m-plane GaN and InGaN/GaN multiple quantum well structures grown on {gamma}-LiAlO{sub 2} by metal organic vapor phase epitaxy.

36 MATERIALS SCIENCE↗

Positronium Formation Of Glyeisdyl Methacrylic Acid (GMA)/Styrene Grafted On PVDF Membrane For Fuel Cells

Simultaneous gamma irradiation was used effectively for grafting of glycidyl methacrylic acid and styrene onto Poly vinyldine fluoride (PVDF). Membranes were characterized by thermal gravimetric analysis (TGA) and scanning electron microscopy (SEM). The properties of the obtained membranes were evaluated in terms of proton conductivity, methanol permeability and positron annihilation lifetime (PALS) parameters. The high probability of Positronium formation enables the application of PALS to the study of free volume. Good property values approved the applicability of the membrane from the cost benefit point of view.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Compact FEL-driven inverse compton scattering gamma-ray source

Many research and applications areas require photon sources capable of producing gamma-ray beams in the multi-MeV energy range with reasonably high fluxes and compact footprints. Besides industrial, nuclear physics and security applications, a considerable interest comes from the possibility to assess the state of conservation of cultural assets like statues, columns etc., via visualization and analysis techniques using high energy photon beams. Computed Tomography scans, widely adopted in medicine at lower photon energies, presently provide high quality three-dimensional imaging in industry and museums. We explore the feasibility of a compact source of quasi-monochromatic, multi-MeV gamma-rays based on Inverse Compton Scattering (ICS) from a high intensity ultra-violet (UV) beam generated in a free-electron laser by the electron beam itself. This scheme introduces a stronger relationship between the energy of the scattered photons and that of the electron beam, resulting in a device much more compact than a classic ICS for a given scattered energy. As a result, the same electron beam is used to produce gamma-rays in the 10–20 MeV range and UV radiation in the 10–15 eV range, in a ~4 × 22 m 2 footprint system.

43 PARTICLE ACCELERATORS↗

Dual-headed SPECT for awake animal brain imaging

Motion-corrected awake animal imaging is needed for normal-state investigations of models of neurological disease and brain activity. The awake animal brain SPECT/CT system, AwakeSPECT at Johns Hopkins University has in the past used a single gamma camera for imaging. Enhancements have been made by adding a pinhole collimator to the second gamma camera at the opposite side which has been previously equipped parallel hole collimator. Geometry calibration was performed using a custom built quality control phantom containing three Co-57 point sources and applied to the tomographic reconstruction code. Hot-rod phantom scans with Tc-99m were performed to test sensitivity and resolution improvements. The reconstruction results show significant resolution and sensitivity improvements.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effects of MAR-M247 substrate (modified) composition on coating oxidation coating/substrate interdiffusion

The effects of gamma+gamma' Mar-M247 substrate composition on gamma+beta Ni-Cr-Al-Zr coating oxidation and coating/substrate interdiffusion were evaluated. These results were also compared to a prior study for a Ni-Cr-Al-Zr coated gamma Ni-Cr-Al substrate with equivalent Al and Cr atomic percentages. Cyclic oxidation behavior at 1130 C was investigated using change in weight curves. Concentration/distance profiles were measured for Al, Cr, Co, W, and Ta. The surface oxides were examined by X-ray diffraction and scanning electron microscopy. The results indicate that variations of Ta and C concentrations in the substrate do not affect oxidation resistance, while additions of grain boundary strengthening elements (Zr, Hf, B) increase oxidation resistance. In addition, the results indicate that oxidation phenomena in gamma+beta/gamma+gamma' Mar-M247 systems have similar characteristics to the l gamma+beta/gamma Ni-Cr-Al system.

Pilsner, B. H.↗

Micrometeorite Impacts in Beringian Mammoth Tusks and a Bison Skull

We have discovered what appear to be micrometeorites imbedded in seven late Pleistocene Alaskan mammoth tusks and a Siberian bison skull. The micrometeorites apparently shattered on impact leaving 2 to 5 mm hemispherical debris patterns surrounded by carbonized rings. Multiple impacts are observed on only one side of the tusks and skull consistent with the micrometeorites having come from a single direction. The impact sites are strongly magnetic indicating significant iron content. We analyzed several imbedded micrometeorite fragments from both tusks and skull with laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) and X-ray fluorescence (XRF). These analyses confirm the high iron content and indicate compositions highly enriched in nickel and depleted in titanium, unlike any natural terrestrial sources. In addition, electron microprobe (EMP) analyses of a Fe-Ni sulfide grain (tusk 2) show it contains between 3 and 20 weight percent Ni. Prompt gamma-ray activation analysis (PGAA) of a particle extracted from the bison skull indicates ~;;0.4 mg of iron, in agreement with a micrometeorite ~;;1 mm in diameter. In addition, scanning electron microscope (SEM) images and XRF analyses of the skull show possible entry channels containing Fe-rich material. The majority of tusks (5/7) have a calibrated weighted mean 14C age of 32.9 +- 1.8 ka BP, which coincides with the onset of significant declines<36 ka ago in Beringian bison, horse, brown bear, and mammoth populations, as well as in mammoth genetic diversity. It appears likely that the impacts and population declines are related events, although their precise nature remains to be determined.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Simulation of pseudo-CT images based on deformable image registration of ultrasound images: A proof of concept for transabdominal ultrasound imaging of the prostate during radiotherapy

Purpose: Imaging of patient anatomy during treatment is a necessity for position verification and for adaptive radiotherapy based on daily dose recalculation. Ultrasound (US) image guided radiotherapy systems are currently available to collect US images at the simulation stage (US{sub sim}), coregistered with the simulation computed tomography (CT), and during all treatment fractions. The authors hypothesize that a deformation field derived from US-based deformable image registration can be used to create a daily pseudo-CT (CT{sub ps}) image that is more representative of the patients’ geometry during treatment than the CT acquired at simulation stage (CT{sub sim}). Methods: The three prostate patients, considered to evaluate this hypothesis, had coregistered CT and US scans on various days. In particular, two patients had two US–CT datasets each and the third one had five US–CT datasets. Deformation fields were computed between pairs of US images of the same patient and then applied to the corresponding US{sub sim} scan to yield a new deformed CT{sub ps} scan. The original treatment plans were used to recalculate dose distributions in the simulation, deformed and ground truth CT (CT{sub gt}) images to compare dice similarity coefficients, maximum absolute distance, and mean absolute distance on CT delineations and gamma index (γ) evaluations on both the Hounsfield units (HUs) and the dose. Results: In the majority, deformation did improve the results for all three evaluation methods. The change in gamma failure for dose (γ{sub Dose}, 3%, 3 mm) ranged from an improvement of 11.2% in the prostate volume to a deterioration of 1.3% in the prostate and bladder. The change in gamma failure for the CT images (γ{sub CT}, 50 HU, 3 mm) ranged from an improvement of 20.5% in the anus and rectum to a deterioration of 3.2% in the prostate. Conclusions: This new technique may generate CT{sub ps} images that are more representative of the actual patient anatomy than the CT{sub sim} scan.

60 APPLIED LIFE SCIENCES↗

MadDM v.3.0: a Comprehensive Tool for Dark Matter Studies

We present MadDM v.3.0, a numerical tool to compute particle dark matter observables in generic new physics models. The new version features a comprehensive and automated framework for dark matter searches at the interface of collider physics, astrophysics and cosmology and is deployed as a plugin of the MadGraph5 aMC@NLO platform, inheriting most of its features. With respect to the previous version, MadDM v.3.0 can now provide predictions for indirect dark matter signatures in astrophysical environments, such as the annihilation cross section at present time and the energy spectra of prompt photons, cosmic rays and neutrinos resulting from dark matter annihilation. MadDM indirect detection features support both 2 → 2 and 2 → n dark matter annihilation processes. In addition, the ability to compare theoretical predictions with experimental constraints is extended by including the Fermi-LAT likelihood for gamma-ray constraints from dwarf spheroidal galaxies and by providing an interface with the nested sampling algorithm PyMultiNest to perform high dimensional parameter scans efficiently. We validate the code for a wide set of dark matter models by comparing the results from MadDM v.3.0 to existing tools and results in the literature.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Data for "Plasmon-driven exciton formation in a non-equilibrium Fermi liquid"

This repository contains source data for key plots presented in the manuscript "Plasmon-driven exciton formation in a non-equilibrium Fermi liquid." Experimental data that was analyzed in Igor Pro 8 are presented as the .pxp files used to generate individual sub-plots. Electronic spectral function calculations are provided as .txt files, in which consecutive rows refer to the meshgrid x coordinate, y coordinate, spectral function (and, where relevant, axis-projected local angular momentum). We additionally include the Wannier model and DFT-obtained bulk band structure on which the Wannier model was based. Files are named as the number of the figure in the manuscript to which they correspond, with additional details included where necessary. Details of file names: 2a_DOS_Lxz_Ek_KGM_40layer_xnum_800kpt_tot.txt: Density of states, xz-axis projected local orbital angular momentum, for 800 points along the K-Gamma-M path, for a 40-layer model. 2c_composite_y.pxp: ARPES (angle-resolved photoemission spectroscopy) spectra along the ky axis, including both a scan near the Fermi level and a scan at high kinetic energies. 2d_LCP_RCP_diff_Sect_20K.pxp: difference between ARPES constant energy cuts at T=20 K at E0 + 0.23 eV taken with left- and right-circularly polarized photons. The polarization-integrated intensity at the constant energy cut is also included. 2e_DOS_L45_E11pt79_m0pt25to0pt25_xnum_800kpt_tot.txt: Density of states, xz-projected local orbital angular momentum, and corresponding k-points in two dimensions from ab-initio electronic structure calculations for a constant-energy cut. 3a_[x]_[y]ps: ARPES cut under excitation at a fluence of x uJ/cm2, measured y ps after photoexcitation. Measurements were performed at 9 K. 3b_[x]: Energy distribution curves under excitation at a fluence x uJ/cm2 at selected delay times after photoexcitation. 4a_ImSigma_vs_temperature.pxp: Imaginary self energy (extracted from ARPES linewidths) at different energies above E0 for selected lattice temperatures. 4b_EELS_lowE.pxp: Electron energy loss spectrum over a low energy range 5b_diff_55m15.pxp: Difference between momentum-integrated Tr-ARPES traces at 55 uJ/cm2 and 15 uJ/cm2 photoexcitation. Time-dependent intensity at each energy level has been normalized to a maximum of 1 for each individual fluence prior to subtraction. 5d_invtau_at_EX_vs_fluence.pxp: decay rate at a specified energy EX for different excitation fluences, from single exponential fits. NOTE: Analyses based on the Wannier model presented here should cite both the associated Article and this dataset. For all other files in the repository, citing the dataset alone is sufficient.

Acharya, Rishi [University of Illinois] (ORCID:000↗

Apollo scientific experiments data handbook

A brief description of each of the Apollo scientific experiments was described, together with its operational history, the data content and formats, and the availability of the data. The lunar surface experiments described are the passive seismic, active seismic, lunar surface magnetometer, solar wind spectrometer, suprathermal ion detector, heat flow, charged particle, cold cathode gage, lunar geology, laser ranging retroreflector, cosmic ray detector, lunar portable magnetometer, traverse gravimeter, soil mechanics, far UV camera (lunar surface), lunar ejecta and meteorites, surface electrical properties, lunar atmospheric composition, lunar surface gravimeter, lunar seismic profiling, neutron flux, and dust detector. The orbital experiments described are the gamma-ray spectrometer, X-ray fluorescence, alpha-particle spectrometer, S-band transponder, mass spectrometer, far UV spectrometer, bistatic radar, IR scanning radiometer, particle shadows, magnetometer, lunar sounder, and laser altimeter. A brief listing of the mapping products available and information on the sample program were also included.

Eichelman, W. F.↗

Multilayer Monochromator For Hard X Rays And Gamma Rays

Compact monochromator for hard x rays and gamma rays provides high spectral resolution with high throughput. Resembles instruments in "Compact X-Ray and Extreme-Ultraviolet Monochromator" (MFS-28499), "Scanning X-Ray or Extreme-Ultraviolet Monochromator" (MFS-28492), "Ultra-High-Spectral-Resolution X-Ray/EUV Monochromator" (MFS-28500), and "Four-Mirror X-Ray and Extreme-Ultraviolet Monochromator" (MFS-28498). Operates on principle of multilayer Bragg reflector. Used in nuclear, astronomical, and biomedical research, x-ray crystallography, research on processing materials, research in x-ray lasers, and x-ray lithography.

Hoover, Richard B.↗

BATSE as an all-sky monitor for INTEGRAL

It is proposed to use data from the burst and transient source experiment (BATSE) onboard the Compton Gamma Ray Observatory (CGRO) as a sensitive, rapid, all sky monitor for the International Gamma Ray Astrophysics Laboratory (INTEGRAL). The all sky earth occultation monitoring and imaging capabilities of BATSE will complement and extend the Galactic plane scans of INTEGRAL as well as provide high latitude Galactic coverage which is inaccessible to INTEGRAL. Examples of transients previously observed by BATSE, its sensitivity, and the response time for these observations are described. Examples of the variability of several of the brighter sources observed by BATSE are shown.

Fishman, G. J.↗

Wide-field Hard X-ray Survey with ART-XC

The Astronomical Roentgen Telescope X-ray Concentrator (ART-XC) instrument onboard the Spectrum Röntgen Gamma (SRG) mission began the 4-year all-sky hard X-ray survey since December 2019 and has already completed four scans of the sky. The observations of the ecliptic pole regions will reach exceptional depth thanks to the survey design of overlapping exposure in these regions. We will discuss the progress of the ART-XC survey in the North Ecliptic Pole (NEP) region so far, including the status of the data reduction and analysis pipeline as well as the survey results.

Chien-Ting Chen↗