Distributed Photovoltaic Economic Impact Analysis in Indonesia

Like other countries in the region, the Government of Indonesia aims to increase its use renewable energy in the near term from various technologies, including grid-connected distributed photovoltaics (DPV). While little DPV has been installed to date, the policy landscape has been shifting over the past few years with recent pronouncements from the state-run utility Perusahaan Listrik Negara (PLN) and the Ministry of Energy and Mines (MEMR) that have begun to provide a more supportive policy framework for the deployment of DPV. Nonetheless, many questions remain as to how DPV impacts customers, the utility, and the economy as a whole. This report presents a holistic view of DPV economic impacts in the Java-Bali region of Indonesia by assessing customer economic impacts, utility revenue impacts, and jobs and economic development impacts.

14 SOLAR ENERGY↗

Grid-Scale Ternary-Pumped Thermal Electricity Storage for Flexible Operation of Nuclear Power Generation under High Penetration of Renewable Energy Sources

In this work, the integration of a grid-scale ternary-Pumped Thermal Electricity Storage (t-PTES) with a nuclear power generation to enhance operation flexibility is assessed using physics-based models and digital real time simulation. A part of the electricity from the nuclear power generation is delivered to the grid, and the balance is used to power a heat pump that can be augmented by an auxiliary resistive load element to increase the charging rate of the thermal storage. This increases the thermal potential between hot and cold thermal stores (usually solid materials or molten salts inside large storage tanks). The thermal energy is transformed back into electricity by reversing the heat pump cycle. Different transient scenarios including startup, shutdown, and power change for grid-connected operation are simulated to determine the behavior of the hybrid nuclear-t-PTES system operating under variable loads that constitute a departure from conventional, baseload nuclear plant operation schemes. Ternary refers to the three modes operation: (i) heat pump (including heating coil), (ii) heat engine, and (iii) simultaneous operation of heat pump (including heating coil) and heat engine during changeover from pumping to generation or vice-versa. The controllability of t-PTES in the short timescales as a dynamic load is used to demonstrate operational flexibility of hybrid nuclear plants for flexible operation through advanced load management. The integration of t-PTES into nuclear power systems enhances the system flexibility and is an enabler for high penetration of renewable energy resources.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Network Reduction Algorithm for Developing Distribution Feeders for Real-Time Simulators

As advanced grid-support functions (AGF) become more widely used in grid-connected photovoltaic (PV) inverters, utilities are increasingly interested in their impacts when implemented in the field. These effects can be understood by modeling feeders in real-time simulators and test PV inverters using power hardware-in-the-loop (PHIL) techniques. This paper presents a novel feeder model reduction algorithm using a ruin & reconstruct methodology that enables large feeders to be solved and operated on real-time computing platforms. Two Hawaiian Electric feeder models in Synergi Electric's load flow software were converted to reduced order models in OpenDSS, and subsequently implemented in the OPAL-RT real-time digital testing platform. Smart PV inverters were added to the realtime model with AGF responses modeled after characterizing commercially available hardware inverters. Finally, hardware inverters were tested in conjunction with the real-time model using PHIL techniques so that the effects of AGFs on the feeders could be analyzed.

14 SOLAR ENERGY↗

Network Reduction Algorithm for Developing Distribution Feeders for Real-Time Simulators: Preprint

As advanced grid-support functions (AGF) become more widely used in grid-connected photovoltaic (PV) inverters, utilities are increasingly interested in their impacts when implemented in the field. These effects can be understood by modeling feeders in real-time systems and testing PV inverters using power hardware-in-the-loop (PHIL) techniques. This paper presents a novel feeder model reduction algorithm using a Monte Carlo method that enables large feeders to be solved and operated on real-time computing platforms. Two Hawaiian Electric feeder models in Synergi Electric's load flow software were converted to reduced order models in OpenDSS, and subsequently implemented in the OPAL-RT real-time digital testing platform. Smart PV inverters were added to the real-time model with AGF responses modeled after characterizing commercially available hardware inverters. Finally, hardware inverters were tested in conjunction with the real-time model using PHIL techniques so that the effects of AGFs on the choice feeders could be analyzed.

14 SOLAR ENERGY↗

Electricity Produced from Photovoltaic Systems in Apartment Buildings and Self-Consumption: Comparison of the Situation in Various IEA PVPS Countries

Over the last two decades, grid-connected solar photovoltaic systems have increased from a niche market to one of the leading power generation capacity additions annually. In 2018 the total installed photovoltaic electricity generation capacity exceeded 500 GW. Another doubling is forecasted until the early 2020s. Therefore, the further development is coupled with the question at what prices solar photovoltaic electricity can be provided and delivered to the customers. The installation of PV systems for self-consumption is already now an interesting option for many people but in general limited to those who have access to a rooftop they own or can use. A new envelopment to enable residents of multi apartment buildings to commonly use electricity generated by a PV system (collective self-consumption) is a relatively new development and is still facing a lot of administrative and regulatory challenges.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A Large-Scale Hardware Experiment Demonstration of Operating High Inverter-Based Resource Power Systems With Grid-Forming Inverters

This paper presents experimental hardware results from a microgrid system as the penetration level of grid-forming (GFM) inverters increases. The experiment aims to showcase the advantages of GFM inverters in enhancing system stability and to investigate the operational challenges in systems relying entirely on inverter-based resources (IBRs). Five test scenarios are devised to progressively increase GFM inverter penetration levels: 0% (S1), 19% (S2), 37% (S3), 68% (S4), and 100% (S5). To ensure consistency, identical loading conditions and dynamic events are applied across all scenarios. The conducted tests include load step changes, output variation of grid-following (GFL) inverters during islanded mode, transition operations (such as synchronization to the grid and islanding), and rateof- change-of-frequency (ROCOF) and voltage jump tests during grid-connected mode. Key findings from the tests are summarized as follows: (1) Scenario S1 proved most challenging for load steps, and GFL variations because of insufficient GFM capacity, leaving the diesel generator unable to handle transient ridethrough; (2) Scenario S5 was the most difficult for transition operations, because the lack of a diesel generator to maintain stiff bus voltage resulted in unexpected reactive power flows during synchronization, causing the point of common coupling (PCC) breaker to trip; (3) Scenarios S4 and S5 were particularly challenging for ROCOF tests because of minimal system inertia, leading to large transients that triggered breaker trips; and (4) Scenario S4 exhibited the strongest voltage recovery capability because of the presence of the diesel generator and a higher number of GFM inverters, both of which possess the highest capacity for reactive power injection.

24 POWER TRANSMISSION AND DISTRIBUTION↗

FINAL REPORT: SUNSHINE STATE SOLAR GRID INITIATIVE (SUNGRIN) PHASE 1 (Critical Milestone Review Version)

This report provides details on the activities and accomplishments of Phase 1 of the Sunshine State Solar Grid Initiative (SUNGRIN) Project for the period beginning 4/28/2010 and ending 12/31/2011. SUNGRIN is a five-phase high-penetration solar PV project within the Systems Integration (SI) area of the Solar Energy Technologies (SETP) Program, under the SunShot Initiative. SUNGRIN is focused on understanding and enabling high-penetration grid-connected solar PV through simulation assisted studies of actual Florida utility high-penetration distribution circuits as well as substations and, to a limited extent, the bulk power system. Each phase builds and expands upon the efforts of the previous phase, leading to a comprehensive examination and understanding of high-penetration solar PV issues, from the solar resource to the conversion and integration technologies to the electric power system, with Florida and it’s utility partners providing the broad range of conditions and system integration scenarios necessary to develop useful insight and solutions. This phase, Phase 1, was funded with American Recovery and Reinvestment Act (ARRA) funds. This version of the final report is organized to align with statement of project objectives (SOPO) critical milestones.

14 SOLAR ENERGY↗

High Penetration Solar PV Deployment Sunshine State Solar Grid Initiative (SUNGRIN)

The report provides results from the Sunshine State Solar Grid Initiative (SUNGRIN) high penetration solar PV deployment project led by Florida State University’s (FSU) Center for Advanced Power Systems (CAPS). FSU CAPS and industry and university partners have completed a five-year effort aimed at enabling effective integration of high penetration levels of grid-connected solar PV generation. SUNGRIN has made significant contributions in the development of simulation-assisted techniques, tools, insight and understanding associated with solar PV effects on electric power system (EPS) operation and the evaluation of mitigation options for maintaining reliable operation. An important element of the project was the partnership and participation of six major Florida utilities and the Florida Reliability Coordinating Council (FRCC). Utilities provided details and data associated with actual distribution circuits having high-penetration PV to use as case studies. The project also conducted foundational work supporting future investigations of effects at the transmission / bulk power system level. In the final phase of the project, four open-use models with built-in case studies were developed and released, along with synthetic solar PV data sets, and tools and techniques for model reduction and in-depth parametric studies of solar PV impact on distribution circuits. Along with models and data, at least 70 supporting MATLAB functions have been developed and made available, with complete documentation.

14 SOLAR ENERGY↗

An Overview of Behind-the-Meter Solar-Plus-Storage Program Design: With Considerations for India

Indian consumers have been deploying behind-the-meter generation (predominantly diesel backup, and, more recently, photovoltaic) and storage systems (predominantly lead-acid and other kinds of batteries as uninterrupted power supplies) by the millions for decades) to address reliability issues within the Indian power system. The same energy storage systems could provide additional services to the consumer and distribution companies if properly regulated and designed from the outset to be grid interactive. Grid-connected distributed solar PV (DPV), or rooftop solar, has also seen wide deployment in India and features prominently in the Government of India’s plans for a transition to clean, reliable, and affordable energy for all. At the same time, many utilities and state governments, as well as the central government in India are currently funding-constrained for both operational and future capital expenditures in the power sector, and some perceive customer-sited resources as exacerbating existing financial challenges. In that context, behind-the-meter energy storage systems paired with distributed photovoltaic (DPV) - with the capability to act as both generation and load - represent a potentially unique and disruptive power sector technology capable of providing a range of important services to customers, utilities, and the broader power system in India. This report aims to offer a comprehensive, evidence-based approach to designing customer programs based on experience in the United States that can help regulators, utilities, and policymakers in India manage the range of challenges and opportunities that increased behind-the-meter energy storage deployment will bring to the power system, in particular when these systems are paired with DPV.

14 SOLAR ENERGY↗

Building a 40% Energy Saving House in the Mixed-Humid Climate

This report describes a home that uses 40% less energy than the energy-efficient Building America standard - a giant step in the pursuit of affordable near-zero-energy housing through the evolution of five near-zero-energy research houses. This four-bedroom, two-bath, 1232-ft2 house has a Home Energy Rating System (HERS) index of 35 (a HERS rating of 0 is a zero-energy house, a conventional new house would have a HERS rating of 100), which qualifies it for federal energy efficiency and solar incentives. The house is leading to the planned construction of a similar home in Greensburg, Kansas, and 21 staff houses in the Walden Reserve, a 7000-unit "deep green" community in Cookville, Tennessee. Discussions are underway for construction of similar houses in Charleston, South Carolina, Seattle, Washington, Knoxville and Oak Ridge, Tennessee, and upstate New York. This house should lead to a 40% and 50% Gate-3, Mixed-Humid-Climate Joule for the DOE Building America Program. The house is constructed with structurally-insulated-panel walls and roof, raised metal-seam roof with infrared reflective coating, airtight envelope (1.65 air changes per hour at 50 Pascal), supply mechanical ventilation, ducts inside the conditioned space, extensive moisture control package, foundation geothermal space heating and cooling system, ZEHcor wall, solar water heater, and a 2.2 kWp grid-connected photovoltaic (PV) system. The detailed specifications for the envelope and the equipment used in ZEH5 compared to all the houses in this series are shown in Tables 1 and 2. Based on a validated computer simulation of ZEH5 with typical occupancy patterns and energy services for four occupants, energy for this all-electric house is predicted to cost only $0.66/day ($0.86/day counting the hookup charges). By contrast, the benchmark house would require $3.56/day, including hookup charges (these costs are based on a 2006 residential rates of $0.07/kWh and solar buyback at $0.15/kWh). The solar fraction for this home located in Lenoir City, Tennessee, is predicted to be as high as 41%(accounting for both solar PV and the solar water heater). This all-electric home is predicted to use 25 kWh/day based on the one year of measured data used to calibrate a whole-building simulation model. Based on two years of measured data, the roof-mounted 2.2 kWp PV system is predicted to generate 7.5 kWh/day. The 2005 cost to commercially construct ZEH5, including builder profit and overhead, is estimated at about $150,000. This cost - for ZEH5's panelized construction, premanufactured utility wall (ZEHcor), foundation geothermal system, and the addition of the walkout lower level, and considering the falling cost for PV - suggests that the construction cost per ft2 for a ZEH5 two-story will be even more cost-competitive. The 2005 construction cost estimate for a finished-out ZEH5 with 2632 ft2 is $222,000 or $85/ft2. The intention of this report is to help builders and homeowners make the decision to build zero-energy-ready homes. Detailed drawings, specifications, and lessons learned in the construction and analysis of data from about 100 sensors monitoring thermal performance for a one-year period are presented. This information should be specifically useful to those considering structural insulated panel walls and roof, foundation geothermal space heating and cooling, solar water heater and roof-mounted, photovoltaic, grid-tied systems.

14 SOLAR ENERGY↗

Advancing the Deployment of Utility-Scale Photovoltaic Plants in the Northeast

As one of the premier research laboratories operated by the Department of Energy, Brookhaven National Laboratory (BNL) is pursuing an energy research agenda that focuses on renewable energy systems and will help to secure the nation's energy security. A key element of the BNL research is the advancement of grid-connected utility-scale solar photovoltaic (PV) plants, particularly in the northeastern part of the country where BNL is located. While a great deal of information has been generated regarding solar PV systems located in mostly sunny, hot, arid climates of the southwest US, very little data is available to characterize the performance of these systems in the cool, humid, frequently overcast climates experienced in the northeastern portion of the country. Recognizing that there is both a need and a market for solar PV generation in the northeast, BNL is pursuing research that will advance the deployment of this important renewable energy resource. BNL's research will leverage access to unique time-resolved data sets from the 37MWp solar array recently developed on its campus. In addition, BNL is developing a separate 1MWp solar research array on its campus that will allow field testing of new PV system technologies, including solar modules and balance of plant equipment, such as inverters, energy storage devices, and control platforms. These research capabilities will form the cornerstone of the new Northeast Solar Energy Research Center (NSERC) being developed at BNL. In this paper, an overview of BNL's energy research agenda is given, along with a description of the 37MWp solar array and the NSERC.

14 SOLAR ENERGY↗

Investigating capacity credit sensitivity to reliability metrics and computational methodologies

Assigning capacity value to renewable energy sources (RES) is a challenge faced in planning their integration with the grid. The difficulties stem from the natural characteristics of variability and intermittency of wind and solar sources. The capacity credit (CC) analysis evaluates the system’s actual power output compared with a constant capacity generator, i.e., conventional generator and determines an effective capacity to use for planning and operation. Herein this paper presents different factors that could affect the CC of a system. Two methods are proposed to determine the CC, namely equivalent firm capacity (EFC) and effective load carrying capability (ELCC). Since these methods are based on satisfying reliability criteria, daily loss of load expectation (LOLE), hourly loss of load (LOLH), and expected energy not served (EENS) have been employed as indices. To obtain the CC value, both methods apply two techniques: traditional and optimization. Genetic algorithm (GA) is the optimization approach used in this paper. Then, this work compares the two techniques and shows the superior performance of the optimization approach. Two hybrid systems, stand-alone (SA) and grid-connected (GC) modes, are proposed and used as case studies. The hybrid systems consist of photovoltaic (PV), wind turbine (WT), and battery energy storage system (BESS). In this work, three different scenarios are used to compare capacity credit: system as a whole, only wind, and no batteries. Finally, sensitivity analysis is carried out to examine the impact of varying the wind speed, solar irradiation, and load. It is demonstrated that the choice of reliability index plays an important role in determining the capacity credit and it is shown that EENS is a more comprehensive and consistent index of reliability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The impact of climate on solvent-based direct air capture systems

Direct air capture (DAC) is increasingly seen as a critical technology to reach mid-century net-zero targets and limit climate change to well below 2 °C. While the commercialization of DAC technologies is being pursued by numerous companies, there remains remarkably little information on their performance under “real-world” conditions. In this paper, for the first time, we investigate the influence of temperature and relative humidity of air on the CO 2 capture rate at the air contactor, overall energy requirement, CO 2 capture efficiency, and levelized cost of liquid-solvent based DAC systems. We observe that the overall energy demand decreases from 11.1 to 8.3 GJ/tCO 2 as the CO 2 capture rate increases from 40 to 85 % and that high capture rates can only be achieved in hot and humid climate conditions. We observe that a CO 2 capture rate of 75 % is only possible above 17 °C and 90 % relative humidity, and this drops dramatically at lower temperatures. It is also observed that water evaporation in the air contactor is highest at dry and low relative humidity, as expected. The sensitivity analysis showed that CO 2 capture efficiency is relatively insensitive to climate conditions for the liquid-solvent based DAC plant. Lastly, the levelized cost of natural gas standalone scenario varies from $240/tCO 2 to $409/tCO 2 , and this is more sensitive to temperature than relative humidity. The levelized cost of the natural gas stand-alone case is between 7 % and 10 % lower than that of an electric grid-connected case across all climate conditions.

54 ENVIRONMENTAL SCIENCES↗

Renewable hydrogen horizon: Geospatial techno-economic feasibility and life cycle greenhouse gas analysis in the Middle East and North Africa

Renewable hydrogen is receiving increasing attention for its potential as a flexible energy carrier in sectors such as transportation and industry. Specific cost and carbon intensity (CI) of renewable hydrogen production vary largely based on the location, owing to differences in renewable energy resources, as well as the supply chain dynamics. This study maps the techno-economic and life cycle greenhouse gas emissions of renewable hydrogen production in the Middle East and North Africa region, leveraging abundant solar and wind resources. The work investigates the variability in hydrogen costs and CI, optimally sizing proton-exchange membrane (PEM) electrolyzers to account for partial and cyclic loading, and explores standalone versus grid-connected systems. PEM capacity ratios of 52 %–63 % for photovoltaic (PV) systems and 28 %–82 % for wind systems were identified as optimal, with hydrogen production costs ranging from $\$3.8$-$\$4.8$/kg for PV and $2.0-$7.0/kg for wind. CIs span from 1.9 to 3.7 kg CO 2 ,eq /kg H 2 for PV and 0.4–7.7 kg CO 2,eq /kg H 2 for wind systems. The study highlights significant cost and CI reductions achievable with technological advancements and co-product revenue from oxygen and excess electricity sales.

Carbon Intensity↗

Estimation of the potential array output charge in the performance analysis of stand-alone photovoltaic systems without MPPT (Case study: Mediterranean climate)

The potential array output energy, E{sub P}, stated by the Joint Research Centre (JRC) in their European Guidelines for the Assessment of Photovoltaic Plants and the IEC Standard 61724 does not estimate properly the potential array output of stand-alone photovoltaic (SAPV) systems without maximum power point tracker (MPPT) as it is the case for SAPV systems with MPPT and grid connected systems. In this way, the main purpose of this paper is to validate an expression that compromises simplicity and accuracy when estimating the potential array output of SAPV systems without MPPT. This issue can be of high interest to photovoltaic (PV) practitioners and experts as it can improve the analysis performance of this type of systems, helping to discriminate better the different losses in this kind of systems. Furthermore, a study of the array potential estimation through different expressions will be developed in order to evaluate which matches better the array potential output in SAPV system without MPPT. Although the analysis will be focused especially in Mediterranean climates, it will be derived some general conclusions that can be considered in other climates. (author)

14 SOLAR ENERGY↗

Statistical analysis of the performance and simulation of a two-axis tracking PV system

The energy produced by a photovoltaic system over a given period can be estimated from the incident radiation at the site where the Grid Connected PV System (GCPVS) is located, assuming knowledge of certain basic features of the system under study. Due to the inherently stochastic nature of solar radiation, the question ''How much energy will a GCPVS produce at this location over the next few years?'' involves an exercise of prediction inevitably subjected to a degree of uncertainty. Moreover, during the life cycle of the GCPVS, another question arises: ''Is the system working correctly?''. This paper proposes and examines several methods to cope with these questions. The daily performance of a PV system is simulated. This simulation and the interannual variability of both radiation and productivity are statistically analyzed. From the results several regression adjustments are obtained. This analysis is shown to be useful both for productivity prediction and performance checking exercises. Finally, a statistical analysis of the performance of a GCPVS is carried out as a detection method of malfunctioning parts of the system. (author)

14 SOLAR ENERGY↗

A review of current anti-islanding methods for photovoltaic power system

Islanding phenomenon is undesirable because it leads to a safety hazard to utility service personnel and may cause damage to power generation and power supply facilities as a result of unsynchronized re-closure. Until now, various anti-islanding methods (AIMs) for detecting and preventing islanding of photovoltaic and other distributed generations (DGs) have been proposed. This paper presents an overview of recent anti-islanding method developments for grid-connected photovoltaic (PV) power generation, focusing on the concept and operating principle, mainly based on single phase system. For the performance comparison, the experimental results of the various AIMs with 3 kW PV inverter are provided based on the islanding detection capability and power quality. As a result, the active AIMs have better islanding detection capability rather than the passive one. However, the active AIMs have power quality degradation on harmonic distortion or displacement power factor based on the injected active signal type. In addition to the evaluation and comparison of the main anti-islanding methods, this paper also summarizes the related anti-islanding standards to evaluate anti-islanding capability for PV system. This paper can be used as a useful anti-islanding reference for future work in DG like PV, and wind turbine. (author)

14 SOLAR ENERGY↗