Search NASA⌕ Search

SEARCH · Search NASA

Results for “HEAT BALANCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

The separatrix electron density in JET, ASDEX upgrade and alcator C-Mod H-mode plasmas: A common evaluation procedure and correlation with engineering parameters

The separatrix electron density is an important parameter for core-edge scenario integration in tokamak devices, as it influences plasma confinement, divertor detachment and disruption avoidance. This quantity has been measured in H-mode discharges on JET, ASDEX Upgrade and Alcator C-Mod by applying the same fitting function to Thomson scattering measurements, and by employing the same analysis technique based on scrape-off layer power balance. To estimate the power crossing the separatrix, the inter-ELM time derivative of the plasma energy d W /d t has been experimentally evaluated and found to be approximately a constant fraction of the absorbed heating power. Correlations between n e,sep and engineering parameters have been investigated, revealing that n e,sep scales with the divertor neutral pressure p 0,div in a similar manner across all devices. Additionally, when n e,sep is normalized to the obtained n e,sep dependency, no clear correlation with the plasma current is found. These observations are in agreement with the 2-point model, which suggests that the upstream separatrix density is mainly set by the recycling at the divertor target.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Performance Evaluation and Optimal Design Analysis of Continuous-Operation Solar-Driven Cooling Absorption Systems With Thermal Energy Storage

A solar absorption cooling system consisting of a flat plate collector, thermal energy storage tank, and absorption chiller is analyzed in this work. A dimensionless model is developed from the energy balance on each component and the chiller's characteristic performance curves. The model is used to determine the interaction and influence of different parameters such as tank size, solar collector area, chiller size, cooling load, cooling temperature, heat loss, and mass flow rates on the performance. From the analysis, smaller solar collector areas are required for lower cooling loads and smaller tank volumes. A specific cooling load of 1 x 10^-5 will require a specific solar collector area between two and six times larger, depending on the initial tank temperature, than the area required for a baseline system that considers typical commercial design and operation parameters. A similar behavior was observed for the specific tank volume. For the baseline system, the minimum specific area of the collector of 9.57 is achieved for an initial tank temperature of 1.19. For a cooling load of 1 x 10^-5, the optimum initial tank temperature will be 1.11 that results in a minimum specific solar collector area of 25.26. A specific tank volume of 4 x 10^-4 will also have an optimum initial tank temperature of 1.11 that minimizes the specific solar collector area to a value of 28.18. The approach and analysis in this work can be used to determine design parameters for solar absorption cooling systems based on a proper relation among system's dimensions to achieve optimum operation.

cooling load↗

Decarbonization of Residential Building Energy Supply: Impact of Cogeneration System Performance on Energy, Environment, and Economics

Electrical and thermal loads of residential buildings present a unique opportunity for onsite power generation, and concomitant thermal energy generation, storage, and utilization, to decrease primary energy consumption and carbon dioxide intensity. This approach also improves resiliency and ability to address peak load burden effectively. Demand response programs and grid-interactive buildings are also essential to meet the energy needs of the 21st century while addressing climate impact. Given the significance of the scale of building energy consumption, this study investigates how cogeneration systems influence the primary energy consumption and carbon footprint in residential buildings. The impact of onsite power generation capacity, its electrical and thermal efficiency, and its cost, on total primary energy consumption, equivalent carbon dioxide emissions, operating expenditure, and, most importantly, thermal and electrical energy balance, is presented. The conditions at which a cogeneration approach loses its advantage as an energy efficient residential resource are identified as a function of electrical grid’s carbon footprint and primary energy efficiency. Compared to a heat pump heating system with a coefficient of performance (COP) of three, a 0.5 kW cogeneration system with 40% electrical efficiency is shown to lose its environmental benefit if the electrical grid’s carbon dioxide intensity falls below 0.4 kg CO 2 per kWh electricity.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Nature-inspired lotus-shaped fins combined with hybrid nanoparticles and metal foam for high-performance latent heat thermal energy storage

Latent heat thermal energy storage (LHTES) systems play a critical role in renewable energy integration by providing high energy density and nearly isothermal operation during phase transitions. However, their performance is often limited by slow melting/charging rates, which motivates the search for enhanced heat transfer designs. This study investigates the melting behavior of RT-82 phase change material (PCM) using novel lotus-shaped fins combined with copper metal foam and conductive graphene nanoparticles and carbon nanotubes. A two-dimensional enthalpy-porosity model in ANSYS Fluent was developed to simulate the charging/melting process, capturing non-thermal equilibrium between the foam and PCM/nano-PCM. In this study, effects of fin geometry, nanoparticle concentration, and foam porosity on melting dynamics and cost-performance trade-offs were investigated. Results showed that natural convection accelerated melting by ~12% compared to conduction-only scenarios. Optimized lotus-shaped fins with higher fin density (T3F4 and T3F10) achieved up to 63% faster melting relative to sparse configurations. Graphene nanoparticles improved thermal conductivity, with a 6% volume fraction, by reducing melting time by ~6.9%, while their combination with 75% porosity foam achieved a maximum reduction in the melting time of ~51% compared to pure PCM. Cost-performance analysis identified T3F4 as the most balanced design, offering rapid thermal response without excessive material costs, while moderate-density designs like T3S6 provided economical alternatives with acceptable performance. These results highlight the performance enhancement that can be achieved by integrating bio-inspired fins, nanoparticles, and foams, into compact and efficient LHTES for solar heating, building thermal management, and industrial waste-heat recovery applications.

25 ENERGY STORAGE↗

Preparation of Mesophase Pitch Feedstock for Carbon Fiber

A filtration process of the low cost mesophase pitch developed by Advanced Carbon Products, LLC (ACP) was developed. The mesophase pitch was melt spun into fiber at the University of Kentucky Center for Applied Energy Research (UKY), and converted to carbon fiber. The melt spinning process was moderately stable, but resulted in some void structure in the green fibers. The tensile properties of the resulting carbon fibers, after graphitization heat treatment, were tested yielding a modulus value of approximately 560 GPa or 81 MSI. This demonstrated that a high modulus graphitic carbon fiber is certainly possible from the ACP 20 mesophase pitch. For future work, a better balance between the softening point temperature, the spinning temperature, and filtering must be met to reduce the volatiles generated in the pitch during spinning. This would reduce voids in the fiber, facilitate spinning, and generate finer, higher performance graphitic fiber.

36 MATERIALS SCIENCE↗

Energetics of surface melt in West Antarctica

We use reanalysis data and satellite remote sensing of cloud properties to examine how meteorological conditions alter the surface energy balance to cause surface melt that is detectable in satellite passive microwave imagery over West Antarctica. This analysis can detect each of the three primary mechanisms for inducing surface melt at a specific location: thermal blanketing involving sensible heat flux and/or longwave heating by optically thick cloud cover, all-wave radiative enhancement by optically thin cloud cover, and föhn winds. We examine case studies over Pine Island and Thwaites glaciers, which are of interest for ice shelf and ice sheet stability, and over Siple Dome, which is more readily accessible for field work. During January 2015 over Siple Dome we identified a melt event whose origin is an all-wave radiative enhancement by optically thin clouds. During December 2011 over Pine Island and Thwaites glaciers, we identified a melt event caused mainly by thermal blanketing from optically thick clouds. Over Siple Dome, those same 2011 synoptic conditions yielded a thermal-blanketing-driven melt event that was initiated by an impulse of sensible heat flux and then prolonged by cloud longwave heating. The December 2011 synoptic conditions also generated föhn winds at a location on the Ross Ice Shelf adjacent to the Transantarctic Mountains, and we analyze this case with additional support from automatic weather station data. In contrast, a late-summer thermal blanketing period over Pine Island and Thwaites glaciers during February 2013 showed surface melt initiated by cloud longwave heating and then prolonged by enhanced sensible heat flux. One limitation thus far with this type of analysis involves uncertainties in the cloud optical properties. Nevertheless, with improvements this type of analysis can enable quantitative prediction of atmospheric stress on the vulnerable Antarctic ice shelves in a steadily warming climate.

54 ENVIRONMENTAL SCIENCES↗

Quantifying Uncertainties in Earth's Energy Budget by Cloud Feedback and Ocean Heat Uptake Using E3SM-Slab Ocean Configurations

In order to improve predictive skills of Earth System Model, we need to better understand processes that control Earth's energy budget via ocean, atmosphere, and cryosphere interactions. Simulated energy budget in comprehensive Earth System Models shows a wide range, leading to large uncertainties in predicting Earth system dynamic and thermodynamic variations and associated social-economic impacts. Uncertainties in cloud feedbacks have been identified as the main cause of the large inter-model spread, but oceanic adjustments, especially those associated with ocean heat uptake (OHU) and the Atlantic Meridional Overturning Circulation (AMOC), also play an important role. In this proposed work, we focus on understanding the individual and combined roles of cloud feedbacks and ocean adjustments on modulating Earth's energy balance. This research is motivated by our overarching hypothesis that oceanic adjustment is a key source of uncertainty, in addition to those associated with the cloud feedbacks; further, the ocean adjustment and associated OHU work through the cloud feedbacks to modulate Earth's energy budget and temperature variations. We test this hypothesis using numerical experiments where we systematically enable and disable cloud feedbacks in conjunction with perturbations to OHU.

58 GEOSCIENCES↗

Heat Wave Impacts on Western US Electricity System

Visualization of hourly generation, load, unserved load, and locational marginal energy prices in the western United States during a July 22-28 heatwave event in 2018 and 2058. In addition to hourly time series data of each of the parameters, choropleth maps showing the hourly value for each balancing authority are provided as well as a county-level choropleth map of temperature.

Mongird, Kendall↗

Modelling the ejection of primary aerosols during the fast pyrolysis of biomass anisotropic particles

A model for the fast pyrolysis of anisotropic biomass particles is presented which considers bubbling dynamics within the liquid intermediate phase (metaplast) and aerosol ejection from this phase. The model employs the population balance equation and the method of moments to estimate the production rate and resultant size distribution of aerosol ejections, incorporating a detailed CRECK reaction mechanism, and considers the effect of anisotropic biomass microstructure on the intraparticle transport of mass and energy. Here, this study investigates the impact of particle size, heating rate (heat transfer coefficient), and lignocellulosic composition on aerosol ejection. The model predicts that, at high heating rates (convective heat transfer coefficient of 359 W/m 2 .K), aerosols can contribute over 20% to the heavy fraction yield in bio-oil for small particles (1 mm diameter, 4 mm length). The model can predict aerosol size distribution and surface area, indicating an average size of 20 μm for bubbles and 5 μm for aerosols during increased bubble production and aerosol ejection rates. These findings are consistent with prior experimental results and provide essential information for future modeling of extra-particle reactions of the aerosols as they progress through the reactor.

09 BIOMASS FUELS↗

Hysteresis between gas breakdown and plasma discharge

In direct-current (DC) discharge, it is well known that hysteresis is observed between the Townsend (gas breakdown) and glow regimes. Forward and backward voltage sweep is performed using a one-dimensional particle-in-cell Monte Carlo collision (PIC-MCC) model considering a ballast resistor. When increasing the applied voltage after reaching the breakdown voltage (V b ), transition from Townsend to glow discharges is observed. When decreasing the applied voltage from the glow regime, the discharge voltage (V d ) between the anode–cathode gap can be smaller than the breakdown voltage, resulting in a hysteresis, which is consistent with experimental observations. Next, the PIC-MCC model is used to investigate the self-sustaining voltage (V s ) in the presence of finite initial plasma densities between the anode and cathode gap. It is observed that the self-sustaining voltage coincides with the discharge voltage obtained from the backward voltage sweep. In addition, the self-sustaining voltage decreases with increased initial plasma density and saturates above a certain initial plasma density, which indicates a change in plasma resistivity. The decrease in self-sustaining voltage is associated with the electron heat loss at the anode for the low pd (rarefied) regime. In the high pd (collisional) regime, the ion energy loss toward the cathode due to the cathode fall and the inelastic collision loss of electrons in the bulk discharge balance out. Finally, it is demonstrated that the self-sustaining voltage collapses to a singular value, despite the presence of a initial plasma, for microgaps when field emission is dominant, which is also consistent with experimental observations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Mathematical Modeling of Multi-Phenomena Anisotropic Systems: Ejection of Primary Aerosols during the Fast Pyrolysis of Biomass

This study introduces a novel particle model for biomass fast pyrolysis, incorporating an anisotropic cylindrical particle to address mass and energy transport coupled with aerosol ejection, which previous models have overlooked. The main contribution lies in developing a model that considers aerosol generation in anisotropic cylindrical particles for the first time, addressing bubbling dynamics and bursting within the liquid phase. The population balance equation describes bubble dynamics and aerosol formation, capturing phenomena like nucleation, growth, coalescence, and bursting. The model employs the method of moments with bubble volume as an internal variable, substantially reducing computational costs by eliminating dependence on this variable. Results highlight the significant impact of anisotropy and particle size on aerosol ejection: smaller, less elongated particles experience faster heating, quicker conversion, and the increased accumulation of the liquid intermediate phase. Specifically, 1 mm diameter particles yield higher concentrations of metaplast and bio-oil aerosols, exceeding 15%, compared to concentrations below 11% for 3 mm particles. This model provides insights into aerosol structure (volume, surface area), aiding in understanding aerosol reactivity at the reactor scale.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Engineered disorder in CO 2 photocatalysis

Light harvesting, separation of charge carriers, and surface reactions are three fundamental steps that are essential for an efficient photocatalyst. Here we show that these steps in the TiO 2 can be boosted simultaneously by disorder engineering. A solid-state reduction reaction between sodium and TiO 2 forms a core-shell c-TiO 2 @a-TiO 2-x (OH) y heterostructure, comprised of HO-Ti-[O]-Ti surface frustrated Lewis pairs (SFLPs) embedded in an amorphous shell surrounding a crystalline core, which enables a new genre of chemical reactivity. Specifically, these SFLPs heterolytically dissociate dihydrogen at room temperature to form charge-balancing protonated hydroxyl groups and hydrides at unsaturated titanium surface sites, which display high reactivity towards CO 2 reduction. This crystalline-amorphous heterostructure also boosts light absorption, charge carrier separation and transfer to SFLPs, while prolonged carrier lifetimes and photothermal heat generation further enhance reactivity. The collective results of this study motivate a general approach for catalytically generating sustainable chemicals and fuels through engineered disorder in heterogeneous CO 2 photocatalysts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Validation of gyrokinetic simulations in NSTX and projections for high-k turbulence measurements in NSTX-U

An extensive validation effort performed for a modest-beta NSTX NBI-heated H-mode discharge predicts that electron thermal transport can be entirely explained by electron-scale turbulence fluctuations driven by the electron temperature gradient mode (ETG), both in conditions of strong and weak ETG turbulence drive. Thermal power-balance estimates computed by TRANSP as well as the shape of the high-k density fluctuation wavenumber spectrum and the fluctuation level ratio between strongly driven and weakly driven ETG-turbulence conditions can be matched by nonlinear gyrokinetic simulations and a synthetic diagnostic for high-k scattering. Linear gyrokinetic simulations suggest that the ion-scale instability in the weak ETG condition is close to the critical threshold for the kinetic ballooning mode instability, and nonlinear ion-scale gyrokinetic simulations show that turbulence might be in a state reminiscent of a Dimits' shift regime, opening speculation on the role that ion-scale turbulence might play for the weak ETG condition. A simulation that matched all experimental constraints is chosen to project high-k turbulence spectra in NSTX-U, revealing that the new high-k system [R. Barchfeld et al., Rev. Sci. Instrum. 89, 10C114 (2018)] should be sensitive to density fluctuations from radially elongated streamer structures. In this study, two schemes are designed to characterize the radial and poloidal wavenumber dependence of the density fluctuation wavenumber power spectrum around the streamer peak, suggesting future high-k fluctuation measurements could be sensitive to an asymmetry in the k r spectrum introduced due to the presence of strong background flow shear.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Physical effects on compact high-velocity clouds in the circumgalactic medium

ABSTRACT We numerically investigate the evolution of compact high-velocity clouds (CHVCs) passing through a hot, tenuous gas representing the highly ionized circumgalactic medium (CGM) by applying the adaptive-mesh refinement code flash. The model clouds start from both hydrostatic and thermal equilibrium and are in pressure balance with the CGM. Here, we present 14 models, divided into two mass categories and two metallicities each and different velocities. We allow for self-gravity and thermal conduction or not. All models experience mass diffusion, radiative cooling, and external heating leading to dissociation and ionization. Our main findings are (1) self-gravity stabilizes clouds against Rayleigh–Taylor instability, which is disrupted within 10 sound-crossing times without; (2) clouds can develop Jeans-instable regions internally even though they are initially below Jeans mass; (3) all clouds lose mass by ram pressure and Kelvin–Helmholtz instability; (4) thermal conduction substantially lowers mass-loss rates, by this, extending the clouds’ lifetimes, particularly, more than doubling the lifetime of low-mass clouds; (5) thermal conduction leads to continuous, filamentary stripping, while the removed gas is heated up quickly and mixes efficiently with the ambient CGM; (6) without thermal conduction the removed gas consists of dense, cool, clumpy fragments; (7) thermal conduction might prevent CHVCs from forming stars; and (8) clouds decelerated by means of drag from the ambient CGM form head-tail shapes and collapse after they reach velocities characteristic for intermediate-velocity clouds. Conclusively, only sophisticated modelling of CHVCs as non-homogeneous and non-isothermal clouds with thermal conduction and self-gravity explains observed morphologies and naturally leads to the suppression of star formation.

Sander, Bastian↗

Evaporation Dataset from a Temperate Closed-basin Lake in Minnesota 2014-2016

This data set contains observed and modeled evaporation data, eddy covariance data, and supporting information measured at White Bear Lake in the Twin Cities Metropolitan Area near St. Paul, Minnesota, USA. The data package includes csv files containing half-hourly latent heat flux, sensible heat flux, and meteorological data from 2014 to 2016. It also includes csv files containing half-hourly observed evaporation measurements, along with supporting data for validation and retrospective modeling of evaporation. This data was collected to examine current, past, and future lake evaporation to better understand how climate will impact the water balance of lakes within this region.

54 ENVIRONMENTAL SCIENCES↗

A Reduced-Order Model of a Nuclear Power Plant with Thermal Power Dispatch

This paper presents reduced-order modeling of thermal power dispatch (TPD) from a pressurized water reactor (PWR) for providing heat to nearby heat consuming industrial processes that seek to take advantage of nuclear heat to reduce carbon emissions. The reactor model includes the neutronics of the reactor core, thermal–hydraulics of the primary coolant cycle, and a three-lump model of the steam generator (SG). The secondary coolant cycle is represented with quasi-steady state mass and energy balance equations. The secondary cycle consists of a steam extraction system, high-pressure and low-pressure turbines, moisture separator and reheater, high-pressure and low-pressure feedwater heaters, deaerator, feedwater and condensate pumps, and a condenser. The steam produced by the SG is distributed between the turbines and the extraction steam line (XSL) that delivers steam to nearby industrial processes, such as production of clean hydrogen. The reduced-order simulator is verified by comparing predictions with results from separate validated steady-state and transient full-scope PWR simulators for TPD levels between 0% and 70% of the rated reactor power. All simulators indicate that the flow rate of steam in the main steam line and turbine systems decrease with increasing TPD, which causes a reduction in PWR electric power generation. The results are analyzed to assess the impact of TPD on system efficiency and feedwater flow control. Due to the simplicity of the proposed reduced-order model, it can be scaled to represent a PWR of any size with a few parametric changes. In the future, the proposed reduced-order model will be integrated into a power system model in a digital real-time simulator (DRTS) and physical hardware-in-the-loop simulations.

08 HYDROGEN↗

Optimizing the fuel efficiency of an opposed piston engine for electric power generation

This paper investigates the optimal crankshaft motion for an opposed piston (OP) engine in a novel hybrid architecture to maximize fuel efficiency. The OP engine was selected for this work due to its inherent thermodynamic benefits and the balanced nature of the engine which can achieve downsizing through reducing the number of cylinders rather than the individual cylinder volume. The typical geartrain required on an OP engine was exchanged for two electric motors, reducing friction loss and decoupling the crankshafts. Using the motors to control the crankshaft motion profiles, this architecture introduces capabilities to dynamically vary compression ratio, combustion volume, and scavenging dynamics. To leverage these opportunities, an optimization scheme was developed utilizing nonlinear optimization of a 0-D model to compute the crankshaft motion profile that maximizes the work generated by the system. This optimization was then iteratively coupled with a high fidelity model which supplies the cylinder flow boundary conditions. This iterative approach reduces the model complexity used in the optimal control problem (OCP) while capturing the gas exchange dynamics critical to the 2-stroke cycle of the OP engine. By using the rate of change of motor torque as the input to the OCP, the torque fluctuation in a single cycle can be limited to ensure tracking feasibility. The results show crankshaft velocity slows during the compression stroke and conversely accelerates during the expansion stroke, reducing the peak motor torque required for control and thus reducing the motor losses. The extended residence time at top dead center, however, leads to an increase in heat transfer, illustrating the trade-off between the work extraction efficiency and the indicated engine efficiency.

Engineering↗

The effect of saturated thermal conduction on clouds in a hot plasma

We numerically investigate the internal evolution of multiphase clouds, which are at rest with respect to an ambient, highly ionized medium (HIM) representing the hot component of the circumgalactic medium. Time-dependent saturated thermal conduction and its implications like condensation rates and mixing efficiency are assessed in multiphase clouds. Our simulations are carried out by using the adaptive mesh refinement code FLASH. The model clouds are initially in both hydrostatic and thermal equilibrium and are in pressure balance with the HIM. Thus, they have steep gradients in both temperature and density at the interface to HIM leading to non-negligible thermal conduction. Several physical processes are considered numerically or semi-analytically: thermal conduction, radiative cooling and external heating of gas, self-gravity, mass diffusion, and dissociation of molecules and ionization of atoms. It turns out that saturated thermal conduction triggers a continuous condensation irrespective of cloud mass. Dynamical interactions with ambient HIM all relate to the radial density gradient in the clouds: (1) mass flux due to condensation is the higher the more homogeneous the clouds are; (2) mixing of condensed gas with cloud gas is easier in low-mass clouds, because of their shallower radial density gradient; and thus (3) accreted gas is distributed more efficiently. A distinct and sub-structured transition zone forms at the interface between cloud and HIM, which starts at smaller radii and is much narrower as deduced from analytical theory.

79 ASTRONOMY AND ASTROPHYSICS↗