Search NASA⌕ Search

SEARCH · Search NASA

Results for “HEAT GAIN”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Optimizing Control for Efficient Load Shifting with Thermal Energy Storage in Existing HVAC Systems

This project developed the integration of a direct-contact heat exchanger (DCHX) based thermal energy storage (TES) system with a chiller–air handling unit (AHU) plant to evaluate its potential for reducing building energy costs. Detailed physical models of the TES unit, building envelope, and HVAC components were developed alongside simplified control-oriented models to support both high-fidelity simulation and real-time optimization. Two control strategies were implemented and compared: a rule-based control (RBC) aligned with utility time-of-use (ToU) rates, and a model predictive control (MPC) framework leveraging forecasts of building load, weather, and internal gains. Simulation results show that the RBC strategy reduced daily electricity costs by around 30% by shifting cooling production from on-peak to off-peak hours. In contrast, the MPC strategy achieved significantly greater performance, reducing daily operating costs by up to 44% and peak-hour costs by more than 60%. Both strategies maintained indoor thermal comfort within acceptable limits, with MPC further improving load distribution and reducing equipment cycling. The outcomes confirm that TES integration, particularly when coordinated with advanced predictive control, can provide substantial cost savings and on-peak demand reduction. . These findings directly support the U.S. Department of Energy’s goals for grid-interactive efficient buildings and demonstrate the potential of TES-enabled HVAC systems for scalable deployment across the commercial building.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Environmental, Health and Safety Assessment Application of a Heat Integrated, Post-combustion CO2 Capture System Using Monoethanolamine and Hitachi H3-1 Solvent at the E.W. Brown Coal-fired Power Plant

An Environmental Health and Safety (EH&S) Assessment was completed for operation of a pilot scale carbon dioxide (CO2) capture system (CCS) at the Louisville Gas & Electric (LG&E) and Kentucky Utilities (KU) Energy, LLC (LG&E-KU) E. W. Brown Generating Station in Harrodsburg, Mercer County, Kentucky. The pilot system was evaluated using two CO2 capture solvents, monoethanolamine (MEA) and Hitachi’s H3-1 solvent. The purpose of the EH&S Assessment was to determine if there were any unacceptable environmental, health or safety concerns that may prevent operation or environmental permitting of a larger scale pilot scale plant. The assessment included review of process flow diagrams, input and output flow rates for primary materials, literature describing similar processes and chemicals used or created during the process, actual air emission and wastewater test data and air emission calculations. The evaluation included identification of risks related to hazardous chemicals, air emissions, wastewater discharges, solid wastes generated and employee hazards. Most potential EH&S issues that were identified are commonly found and successfully managed at large industrial facilities. No risks were identified that could not be successfully managed or would likely prevent implementation or environmental permitting of the pilot or larger scale plant. Potential exposures and resulting health risks from exposure to low concentrations of nitrosamines generated from degradation of the Hitachi H3-1 and possibly MEA solvents may be a health concern for site workers, but additional investigation is needed to accurately assess this risk. Applying the information gained from operating the pilot plant, performing air emission testing and used solvent testing to a large-scale facility at a commercial coal-fired electric generating plant suggests additional air emission control measures may be necessary to reduce potential site worker health risks and possibly community risks. Depending upon the location and regional air quality, considerable effort may be required to obtain the necessary air permit for construction and operation of a similarly configured large-scale PCCCS facility.

gas separation↗

Environmental, Health and Safety Assessment Application of a Heat Integrated, Post-combustion CO 2 Capture System Using Monoethanolamine and Hitachi H3-1 Solvent at the E.W. Brown Coal-Fired Power Plant

An Environmental Health and Safety (EH&S) Assessment was completed for operation of a pilot scale carbon dioxide (CO 2 ) capture system (CCS) at the Louisville Gas & Electric (LG&E) and Kentucky Utilities (KU) Energy, LLC (LG&E-KU) E. W. Brown Generating Station in Harrodsburg, Mercer County, Kentucky. The pilot system was evaluated using two CO 2 capture solvents, monoethanolamine (MEA) and Hitachi’s H3-1 solvent. The purpose of the EH&S Assessment was to determine if there were any unacceptable environmental, health or safety concerns that may prevent operation or environmental permitting of a larger scale pilot scale plant. The assessment included review of process flow diagrams, input and output flow rates for primary materials, literature describing similar processes and chemicals used or created during the process, actual air emission and wastewater test data and air emission calculations. The evaluation included identification of risks related to hazardous chemicals, air emissions, wastewater discharges, solid wastes generated and employee hazards. Most potential EH&S issues that were identified are commonly found and successfully managed at large industrial facilities. No risks were identified that could not be successfully managed or would likely prevent implementation or environmental permitting of the pilot or larger scale plant. Potential exposures and resulting health risks from exposure to low concentrations of nitrosamines generated from degradation of the Hitachi H3-1 and possibly MEA solvents may be a health concern for site workers, but additional investigation is needed to accurately assess this risk. Applying the information gained from operating the pilot plant, performing air emission testing and used solvent testing to a large-scale facility at a commercial coal-fired electric generating plant suggests additional air emission control measures may be necessary to reduce potential site worker health risks and possibly community risks. Depending upon the location and regional air quality, considerable effort may be required to obtain the necessary air permit for construction and operation of a similarly configured large-scale PCCCS facility.

gas separation↗

Temperature response and brine availability to heated boreholes in bedded salt

Abstract There is a growing need for disposal of high‐level nuclear waste. To reduce uncertainty associated with brine availability to repository excavations in salt formations, a collaboration between Sandia, Los Alamos, and Lawrence Berkeley National Laboratories is performing a series of borehole‐scale coupled process tests. Here, we report on the first round of the Brine Availability Test in Salt (BATS) project, a “shakedown” experiment called Phase 1s. Experimental testing included placing a resistive heater, a 260‐W radiative heater, and a 750‐W radiative heater within previously drilled horizontal boreholes at the Waste Isolation Pilot Plant (WIPP) while monitoring temperature and water inflow. The experiments successfully achieved the targeted temperature of 120 °C when using the 750‐W radiative heater. Simulations using FEHM (Finite Element Heat and Mass transfer code) and TOUGH‐FLAC (Transport Of Unsaturated Groundwater and Heat–Fast Lagrangian Analysis of Continua) were able to accurately predict the coupled thermo–hydro–mechanical–chemical response of salt, matching the observed temperature and brine production. Due to the extremely low permeability of salt, these systems take many years to reach steady state when perturbed by mining activities. Long‐term numerical simulations are used to develop the initial pressure and saturation conditions. The inclusion of a damaged rock zone with higher permeability around the borehole also affects the saturation and pressure distributions and plays an important role in dissipating the potential for thermal pressurization. Knowledge gained from this round of experimentation and simulation will be used to conduct the next BATS project experiment in new boreholes at WIPP.

58 GEOSCIENCES↗

A unified understanding of minimum lattice thermal conductivity

Here, we propose a first-principles model of minimum lattice thermal conductivity ($κ^{min}_L$) based on a unified theoretical treatment of thermal transport in crystals and glasses. We apply this model to thousands of inorganic compounds and find a universal behavior of $κ^{min}_L$ in crystals in the high-temperature limit: The isotropically averaged $κ^{min}_L$ is independent of structural complexity and bounded within a range from ~0.1 to ~2.6 W/(m K), in striking contrast to the conventional phonon gas model which predicts no lower bound. We unveil the underlying physics by showing that for a given parent compound, $κ^{min}_L$ is bounded from below by a value that is approximately insensitive to disorder, but the relative importance of different heat transport channels (phonon gas versus diffuson) depends strongly on the degree of disorder. Moreover, we propose that the diffuson-dominated $κ^{min}_L$ in complex and disordered compounds might be effectively approximated by the phonon gas model for an ordered compound by averaging out disorder and applying phonon unfolding. With these insights, we further bridge the knowledge gap between our model and the well-known Cahill–Watson–Pohl (CWP) model, rationalizing the successes and limitations of the CWP model in the absence of heat transfer mediated by diffusons. Finally, we construct graph network and random forest machine learning models to extend our predictions to all compounds within the Inorganic Crystal Structure Database (ICSD), which were validated against thermoelectric materials possessing experimentally measured ultralow κ L . Our work offers a unified understanding of $κ^{min}_L$, which can guide the rational engineering of materials to achieve .

42 ENGINEERING↗

Modeling of Combined Lead Fast Reactor and Concentrating Solar Power Supercritical Carbon Dioxide Cycles to Demonstrate Feasibility, Efficiency Gains, and Cost Reductions

Solar power has innate issues with weather, grid demand and time of day, which can be mitigated through use of thermal energy storage for concentrating solar power (CSP). Nuclear reactors, including lead-cooled fast reactors (LFRs), can adjust power output according to demand; but with high fixed costs and low operating costs, there may not be sufficient economic incentive to make this worthwhile. We investigate potential synergies through coupling CSP and LFR together in a single supercritical CO 2 Brayton cycle and/or using the same thermal energy storage. Combining these cycles allows for the LFR to thermally charge the salt storage in the CSP cycle during low-demand periods to be dispatched when grid demand increases. The LFR/CSP coupling into one cycle is modeled to find the preferred location of the LFR heat exchanger, CSP heat exchanger, sCO 2 -to-salt heat exchanger (C2S), turbines, and recuperators within the supercritical CO 2 Brayton cycle. Three cycle configurations have been studied: two-cycle configuration, which uses CSP and LFR heat for dedicated turbocompressors, has the highest efficiencies but with less component synergies; a combined cycle with CSP and LFR heat sources in parallel is the simplest with the lowest efficiencies; and a combined cycle with separate high-temperature recuperators for both the CSP and LFR is a compromise between efficiency and component synergies. Additionally, four thermal energy storage charging techniques are studied: the turbine positioned before C2S, requiring a high LFR outlet temperature for viability; the turbine after the C2S, reducing turbine inlet temperature and therefore power; the turbine parallel to the C2S producing moderate efficiency; and a dedicated circulator loop. While all configurations have pros and cons, use of a single cycle offers component synergies with limited efficiency penalty. Using a turbine in parallel with the C2S heat exchanger is feasible but results in a low charging efficiency, while a dedicated circulator loop offers flexibility and near-perfect heat storage efficiency but increasing cost with additional cycle components.

14 SOLAR ENERGY↗

Molecular level insight into non-bilayer structure formation in thylakoid membranes: a molecular dynamics study

In oxygenic photosynthetic organisms, the light reactions are performed by protein complexes embedded in the lipid bilayer of thylakoid membranes (TMs). The organization of the bulk lipid molecules into bilayer structures provide optimal conditions for the build-up of the proton motive force (pmf) and its utilization for ATP synthesis. However, the lipid composition of TMs is dominated by the non-bilayer lipid species monogalactosyl diacylglycerol (MGDG), and functional plant TMs, besides the bilayer, contain large amounts of non-bilayer lipid phases. Bulk lipids have been shown to be associated with lumenal, stromal-side and marginal-region proteins and proposed to play roles in the self-assembly and photoprotection of the photosynthetic machinery. Furthermore, it has recently been pointed out that the generation and utilization of pmf for ATP synthesis according to the ‘protet’ or protonic charge transfer model Kell (Biochim Biophys Acta Bioenerg 1865(4):149504, 2024), requires high MGDG content Garab (Physiol Plant 177(2):e70230, 2025). In this study, to gain better insight into the structural and functional roles of MGDG, we employed all atom and coarse-grained molecular dynamics simulations to explore how temperature, hydration levels and varying MGDG concentrations affect the structural and dynamic properties of bilayer membranes constituted of plant thylakoid lipids. Our findings reveal that MGDG promotes increased membrane fluidity and dynamic fluctuations in membrane thickness. MGDG-rich stacked bilayers spontaneously formed inverted hexagonal phases; these transitions were enhanced at low hydration levels and at elevated but physiologically relevant temperatures. It can thus be inferred that MGDG plays important roles in heat and drought stress mechanisms.

59 BASIC BIOLOGICAL SCIENCES↗

Reservoir Characterization and Techno-Economic Analysis of Enhanced Geothermal and Closed-Loop Systems in the Wattenberg Field of the Denver-Julesburg Basin, Colorado

This report provides details of reservoir characterization and techno-economic analysis for enhanced geothermal systems and closed-loop geothermal systems in the Denver-Julesburg Basin Wattenberg area. The analysis contributes to the Geothermal Limitless Approach to Drilling Efficiencies (GLADE) project, a multi-institutional research initiative focused on advancing geothermal energy development by reducing drilling costs and improving the rate of penetration. The GLADE project brings together national laboratories, academic institutions, and industry partners, including the U.S. Department of Energy's Geothermal Technologies Office, Occidental Petroleum, the National Laboratory of the Rockies (NLR), Los Alamos National Laboratory, Colorado School of Mines, Louisiana State University, Texas A&M University, and several drilling technology companies. As part of this effort, NLR developed and applied slender-body theory modeling tools and the GEOPHIRES simulator to support techno-economic analysis. The slender-body theory wellbore simulator evaluated thermal performance in U-loop, Eavor-type multilateral, and enhanced geothermal system well configurations. Results indicated that an optimized single U-loop design delivers an outlet temperature of 168.8 degrees Celsius,stabilizing at a final outlet temperature of 135.3 degrees Celsius. Heat production also improved significantly, with an average thermal output of 16.9 MWth and a final thermal output of 11.0 MWth. These results provided critical baseline data for selecting optimized systems for techno-economic analysis. Building on these outputs, NLR applied the GEOPHIRES techno-economic simulator to estimate the levelized cost of electricity for both the Eavor multilateral and enhanced geothermal systems. The sensitivity analysis showed that drilling costs exert a particularly strong impact on the levelized cost of electricity of multilateral systems. Therefore, advances in drilling technology and improved drilling rates could yield significant gains in the economic performance of these systems. In this context, the GLADE project directly supports the U.S. Department of Energy's mission to reduce the cost of geothermal energy and accelerate the deployment of next-generation geothermal technologies.

15 GEOTHERMAL ENERGY↗

On the Durability of Tin‐Containing Perovskite Solar Cells

Abstract Tin (Sn)‐containing perovskite solar cells (PSCs) have gained significant attention in the field of perovskite optoelectronics due to lower toxicity than their lead‐based counterparts and their potential for tandem applications. However, the lack of stability is a major concern that hampers their development. To achieve the long‐term stability of Sn‐containing PSCs, it is crucial to have a clear and comprehensive understanding of the degradation mechanisms of Sn‐containing perovskites and develop mitigation strategies. This review provides a compendious overview of degradation pathways observed in Sn‐containing perovskites, attributing to intrinsic factors related to the materials themselves and environmental factors such as light, heat, moisture, oxygen, and their combined effects. The impact of interface and electrode materials on the stability of Sn‐containing PSCs is also discussed. Additionally, various strategies to mitigate the instability issue of Sn‐containing PSCs are summarized. Lastly, the challenges and prospects for achieving durable Sn‐containing PSCs are presented.

14 SOLAR ENERGY↗

Irradiation of an enriched uranium (NaCl-UCl 3 ) fuel salt capsule, summary of nondestructive post-irradiation examinations, and solidification modeling

Molten salt reactors (MSRs) are gaining attention due to their potential for safe, carbon-free nuclear energy with reduced waste. However, licensing these reactors is hindered by limited experimental data on fueled salts, both pre- and post-irradiation. Here, the novel Molten-salt Research Temperature-controlled Irradiation (MRTI) vehicle was designed to address knowledge gaps in irradiating enriched‑uranium-bearing salts. The MRTI experiment irradiated 13 cm 3 of UCl₃-NaCl (93 % U-235) salt in the Neutron Radiography (NRAD) Reactor, achieving a burnup of 0.196 GWd/MTU over 390 h. Despite a heater failure, the thermocouple data suggested fission heat kept the salt molten. The MRTI assembly was remotely disassembled for nondestructive post-irradiation examination (PIE), which included precision gamma-ray scanning (PGS) and neutron radiography. Radiograph images showed the location of the salt and the solidification pattern. PGS results provided an early indication that activated materials of construction did not increase in relative intensity in the region of the capsule where the salt was in contact with the material of construction. Additionally, PGS data showed the presence of several gamma emitting fission products, such as Nb-95, Zr-95, Ru-103, Ce-141, and La-140, where Ru-103 had the highest counts at the bottom of the capsule. Computational fluid dynamics modeling supported observations of salt solidification patterns and proved to be a valuable tool to inform PIE activities. The MRTI experiment has thus far provided critical data and lessons learned for fuel salt PIE activities, essential for advancing the technical readiness of MSRs.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Systems Biology-Based Optimization of Extremely Thermophilic Lignocellulose Conversion to Bioproducts

This was a collaborative project involving researchers at the University of Georgia, North Carolina State University, Sanford‐Burnham‐Prebys Med. Discovery Institute and the University of Rhode Island. The over-arching goal was to demonstrate that non-model microorganisms, specifically extreme thermophiles, can be a strategic metabolic engineering platform for industrial biotechnology. We engineered the most thermophilic lignocellulose-degrading organism known, Caldicellulosiruptor bescii (Cbes) , which grows optimally near 80°C, and the most thermophilic fermentative organism known, Pyrococcus furiosus (Pfu) , which grows optimally at 100°C, to produce several key industrial chemicals. This work leveraged recent breakthrough advances in the development of molecular genetic tools for these organisms, complemented by a deep understanding of its metabolism and physiology gained over the past decade of study in the PIs’ laboratories. We applied the latest metabolic reconstruction and modeling approaches to optimize biomass to product conversion. Bio-processing above 70°C can have important advantages over near-ambient operations. Highly genetically-modified microorganisms usually have a fitness disadvantage and can be easily overtaken in culture when contaminating microbes are present. The high growth temperature of extreme thermophiles precludes growth or survival of virtually any contaminating organism or phage. This reduces operating costs associated with reactor sterilization and maintaining a sterile facility. In addition, at industrial scales, heat production from microbial metabolic activity vastly outweighs heat loss through bioreactor walls such that cooling is required. Extreme thermophiles have the advantage that non-refrigerated cooling water can be used if needed, and heating requirements can be met with low-grade steam typically in excess capacity on plant sites. We assembled a highly interdisciplinary team that brought together all of the expertise for the project to have successful outcomes. This project also built upon and utilized extensive information already available in the PIs’ labs for both Cbes and Pfu to develop models that provide a comprehensive description of these organisms’ physiology and metabolism that were utilized to inform metabolic engineering strategies. The models were validated with experimental data and the results demonstrated that unpretreated lignocellulose has the potential to be converted into value-added industrial chemicals at high loading at bioreactor scale. The data generated from this research were published in twenty-one peer-reviewed papers in international journals with online access.

60 APPLIED LIFE SCIENCES↗

Validation Assessment of Turbulent Reacting Flow Model Using The Area-Validation Metric on Medium-Scale Methanol Pool Fire Results

Accident analysis and ensuring power plant safety are pivotal in the nuclear energy sector. Significant strides have been achieved over the past few decades regarding fire protection and safety, primarily centered on design and regulatory compliance. Yet, after the Fukushima accident a decade ago, the imperative to enhance measures against fire, internal flooding, and power loss has intensified. Hence, a comprehensive, multilayered protection strategy against severe accidents is needed. Consequently, gaining a deeper insight into pool fires and their behavior through extensive validated data can greatly aid in improving these measures using advanced validation techniques. A model validation study was performed at Sandia National Laboratories in which a 30-cm diameter methanol pool fire was modeled using the SIERRA/Fuego turbulent reacting flow code. This validation study used a standard validation experiment to compare model results against, and conclusions have been published. The fire was modeled with a Large Eddy Simulation (LES) turbulence model with subgrid turbulent kinetic energy closure. Combustion was modeled using a strained laminar flamelet library approach. Radiative heat transfer was accounted for with a model utilizing the gray-gas approximation. In the present study, additional validation analysis is performed using the area validation metric (AVM). These activities are done on multiple datasets involving different variables and temporal/spatial ranges and intervals. In conclusion, the results provide insight into the use of the area validation metric on such temporally varying datasets and the importance of physics-aware use of the metric for proper analysis.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Beneficial CHP – Is that a Thing? Considering CHP in the Context of Beneficial Electrification

For decades, combined heat and power (CHP) has been promoted and embraced as a cost-effective technology for meeting on-site thermal and electric needs more efficiently and with fewer emissions than separate procurement of those resources. But climate change concerns are leading to a reevaluation of CHP’s benefits. Significantly, natural gas, the most common fuel for CHP and until recently regarded as an environmentally preferable “bridge fuel” in the energy transition to renewables, is increasingly being reexamined amid calls for deep decarbonization and emerging clean energy policies that limit the use of natural gas. Given this trend, electrification has gained traction as a net zero carbon energy strategy. With natural gas being a preferred fuel for CHP, policymakers and others are beginning to question CHP’s role in a cleaner, more electrified future. However, CHP fueled by low carbon fuels such as renewable natural gas and hydrogen may be a more viable path to decarbonizing industrial processes that are difficult to electrify due to technology limitations or cost, and for applications where energy resilience is a critical requirement. This paper seeks to add clarity to a complex issue. It offers a framework for assessing industrial applications where natural gas CHP will provide significant GHG reductions in the near term and provide a more economic and practical path to deep decarbonization in the long term through a transition to low carbon fuels.

Hedman, Bruce↗

Flexible, integrated modeling of tokamak stability, transport, equilibrium, and pedestal physics

The STEP (Stability, Transport, Equilibrium, and Pedestal) integrated-modeling tool has been developed in OMFIT to predict stable, tokamak equilibria self-consistently with core-transport and pedestal calculations. STEP couples theory-based codes to integrate a variety of physics, including magnetohydrodynamic stability, transport, equilibrium, pedestal formation, and current-drive, heating, and fueling. The input/output of each code is interfaced with a centralized ITER-Integrated Modelling & Analysis Suite data structure, allowing codes to be run in any order and enabling open-loop, feedback, and optimization workflows. This paradigm simplifies the integration of new codes, making STEP highly extensible. STEP has been verified against a published benchmark of six different integrated models. Core-pedestal calculations with STEP have been successfully validated against individual DIII-D H-mode discharges and across more than 500 discharges of the H98,y2 database, with a mean error in confinement time from experiment less than 19%. STEP has also reproduced results in less conventional DIII-D scenarios, including negative-central-shear and negative-triangularity plasmas. Predictive STEP modeling has been used to assess performance in several tokamak reactors. Simulations of a high-field, large-aspect-ratio reactor show significantly lower fusion power than predicted by a zero-dimensional study, demonstrating the limitations of scaling-law extrapolations. STEP predictions have found promising scenarios for an EXhaust and Confinement Integration Tokamak Experiment, including a high-pressure, 80%-bootstrap-fraction plasma. ITER modeling with STEP has shown that pellet fueling enhances fusion gain in both the baseline and advanced-inductive scenarios. Finally, STEP predictions for the SPARC baseline scenario are in good agreement with published results from the physics basis.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

In situ spin coater for multimodal grazing incidence x-ray scattering studies

We present herein a custom-made, in situ, multimodal spin coater system with an integrated heating stage that can be programmed with spinning and heating recipes and that is coupled with synchrotron-based, grazing-incidence wide- and small-angle x-ray scattering. The spin coating system features an adaptable experimental chamber, with the ability to house multiple ancillary probes such as photoluminescence and visible optical cameras, to allow for true multimodal characterization and correlated data analysis. This system enables monitoring of structural evolutions such as perovskite crystallization and polymer self-assembly across a broad length scale (2 Å–150 nm) with millisecond temporal resolution throughout a complete thin film fabrication process. The use of this spin coating system allows scientists to gain a deeper understanding of temporal processes of a material system, to develop ideal conditions for thin film manufacturing.

47 OTHER INSTRUMENTATION↗

Preliminary Modeling of Chloride Deposition on Spent Nuclear Fuel Canisters in Dry Storage Relevant to Stress Corrosion Cracking

This study presents a method that can be used to gain information relevant to determining the corrosion risk for spent nuclear fuel (SNF) canisters during extended dry storage. Currently, it is known that stainless steel canisters are susceptible to chloride-induced stress corrosion cracking (CISCC). However, the rate of CISCC degradation and the likelihood that it could lead to a through-wall crack is unknown. This study uses well-developed computational fluid dynamics and particle-tracking tools and applies them to SNF storage to determine the rate of deposition on canisters. The deposition rate is determined for a vertical canister system and a horizontal canister system, at various decay heat rates with a uniform particle size distribution, ranging from 0.25 to 25 µm, used as an input. In all cases, most of the dust entering the overpack passed through without depositing. Most of what was retained in the overpack was deposited on overpack surfaces (e.g., inlet and outlet vents); only a small fraction was deposited on the canister itself. These results are provided for generalized canister systems with a generalized input; as such, this paper is intended to demonstrate the technique. This study is a part of an ongoing effort funded by the U.S. Department of Energy, Nuclear Energy Office of Spent Fuel Waste Science and Technology, which is tasked with doing research relevant to developing a sound technical basis for ensuring the safe extended storage and subsequent transport of SNF. This work is being presented to demonstrate a potentially useful technique for SNF canister vendors, utilities, regulators, and stakeholders to utilize and further develop for their own designs and site-specific studies.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Partially cracked ammonia mixture combustion in gas turbine combustors

Ammonia is gaining popularity for single fuel use in existing gas turbines, as it is carbonless, has higher hydrogen content per unit volume than liquid hydrogen, and facilitates easy storage and handling. However, the low flame speed of ammonia makes it prone to flame blow off and remains the chief concern for its use in power generation. Following previous studies that have shown improved combustion performance by partially cracking the fuel, in this computational study, efficacy of partially cracked ammonia as a replacement fuel for natural gas is evaluated. A high-pressure optically accessible combustor operated at ~10 bar pressure with non-vitiated heated air was used as the test platform. This combustor was equipped with a novel multifuel multi-tube micromixing injector (M3 injector). High resolution simulations of the flow fields both in the injector as well as the combustor were performed to understand the fuel mixing in the injector and in the inlet region of the combustor. These modeling results showed that the injector was highly effective for achieving mixture homogeneity at the entrance of the combustor for ammonia and natural gas injection, whereas, for hydrogen an earlier injection facilitating longer residence time would be beneficial. Also, these simulations show that while harnessing waste heat the ideal fuel dissociation fraction is between 0.4 and 0.55 for optimal operation.

Ammonia↗