X-Band Photonic Band-Gap Accelerator Structure Breakdown Experiment

In order to understand the performance of photonic band-gap (PBG) structures under realistic high gradient, high power, high repetition rate operation, a PBG accelerator structure was designed and tested at X band (11.424 GHz). The structure consisted of a single test cell with matching cells before and after the structure. The design followed principles previously established in testing a series of conventional pillbox structures. The PBG structure was tested at an accelerating gradient of 65 MV/m yielding a breakdown rate of two breakdowns per hour at 60 Hz. An accelerating gradient above 110 MV/m was demonstrated at a higher breakdown rate. Significant pulsed heating occurred on the surface of the inner rods of the PBG structure, with a temperature rise of 85 K estimated when operating in 100 ns pulses at a gradient of 100 MV/m and a surface magnetic field of 890 kA/m. A temperature rise of up to 250 K was estimated for some shots. The iris surfaces, the location of peak electric field, surprisingly had no damage, but the inner rods, the location of the peak magnetic fields and a large temperature rise, had significant damage. Breakdown in accelerator structures is generally understood in terms of electric field effects. These PBG structure results highlight the unexpected role of magnetic fields in breakdown. The hypothesis is presented that the moderate level electric field on the inner rods, about 14 MV/m, is enhanced at small tips and projections caused by pulsed heating, leading to breakdown. Future PBG structures should be built to minimize pulsed surface heating and temperature rise.

43 PARTICLE ACCELERATORS↗

High voltage switch triggered by a laser-photocathode subsystem

A spark gap switch for controlling the output of a high voltage pulse from a high voltage source, for example, a capacitor bank or a pulse forming network, to an external load such as a high gradient electron gun, laser, pulsed power accelerator or wide band radar. The combination of a UV laser and a high vacuum quartz cell, in which a photocathode and an anode are installed, is utilized as triggering devices to switch the spark gap from a non-conducting state to a conducting state with low delay and low jitter.

43 PARTICLE ACCELERATORS↗

High-efficiency acceleration of an electron beam in a plasma wakefield accelerator

High-efficiency acceleration of charged particle beams at high gradients of energy gain per unit length is necessary to achieve an affordable and compact high-energy collider. The plasma wakefield accelerator is one concept being developed for this purpose. In plasma wakefield acceleration, a charge-density wake with high accelerating fields is driven by the passage of an ultra-relativistic bunch of charged particles (the drive bunch) through a plasma. Furthermore, if a second bunch of relativistic electrons (the trailing bunch) with sufficient charge follows in the wake of the drive bunch at an appropriate distance, it can be efficiently accelerated to high energy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Direct Acceleration of Electrons in a Corrugated Plasma Channel

Direct laser acceleration of electrons provides a low power tabletop alternative to laser wakefield accelerators. Until recently, however, direct acceleration has been limited by diffraction, phase matching, and material damage thresholds. The development of the corrugated plasma channel [B. Layer et al., Phys. Rev. Lett. 99, 035001 (2007)] has removed all of these limitations and promises to allow direct acceleration of electrons over many centimeters at high gradients using femtosecond lasers [A. G. York et al., Phys Rev. Lett 100, 195001 (2008), J. P. Palastro et al., Phys. Rev. E 77, 036405 (2008)]. We present a simple analytic model of laser propagation in a corrugated plasma channel and examine the laser-electron beam interaction. Simulations show accelerating gradients of several hundred MeV/cm for laser powers much lower than required by standard laser wakefield schemes. In addition, the laser provides a transverse force that confines the high energy electrons on axis, while expelling low energy electrons.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Comparative study of active plasma lenses in high-quality electron accelerator transport lines

Electrically discharged active plasma lenses (APLs) are actively pursued in compact high-brightness plasma-based accelerators due to their high-gradient, tunable, and radially symmetric focusing properties. In this paper, the APL is experimentally compared with a conventional quadrupole triplet, highlighting the favorable reduction in the energy dependence (chromaticity) in the transport line. Through transport simulations, it is explored how the non-uniform radial discharge current distribution leads to beam-integrated emittance degradation and a charge density reduction at focus. However, positioning an aperture at the APL entrance will significantly reduce emittance degradation without additional loss of charge in the high-quality core of the beam. An analytical model is presented that estimates the emittance degradation from a short beam driving a longitudinally varying wakefield in the APL. Finally, optimizing laser plasma accelerator operation is discussed where emittance degradation from the non-uniform discharge current (favoring small beams inside the APL) and wakefield effects (favoring larger beam sizes) is minimized.

43 PARTICLE ACCELERATORS↗

Warm to cold correlations and other test results of the MQXFA Low-Beta Quadrupole magnets for the High-Luminosity Large Hadron Collider

The production of the MQXFA low-beta quadrupole magnets for the High Luminosity LHC (HL-LHC) is quite advanced with about 20 magnets cold tested in vertical cryostat. The MQXFA magnets are fabricated by the US HL-LHC Accelerator Upgrade Project (AUP) and are being used in the Q1 and Q3 Inner Triplet (IT) elements of the HL-LHC, whereas CERN is fabricating similar magnets for Q2a and Q2b IT elements. These large-aperture, high-gradient quadrupole magnets are first-of-the-kind accelerator magnets introducing Nb_3Sn conductor to High Energy Physics colliders. At this point of MQXFA production there is sufficient data to look at warm to cold correlations for the HL-LHC and for future use of Nb_3Sn magnets in particle accelerators. Examples of warm-cold correlations discussed in this paper are: field quality (including the use of magnetic shims for low-order harmonics correction), magnetic length, magnetic axis and magnetic field angle. A summary of main test data will also be presented and discussed.

Kurian, F. [Brookhaven]↗

Shielded radiography with a laser-driven MeV-energy X-ray source

We report the results of experimental and numerical-simulation studies of shielded radiography using narrowband MeV-energy X-rays from a compact all-laser-driven inverse-Compton-scattering X-ray light source. This recently developed X-ray light source is based on a laser-wakefield accelerator with ultra-high-field gradient (GeV/cm). We demonstrate experimentally high-quality radiographic imaging (image contrast of 0.4 and signal-to-noise ratio of 2:1) of a target composed of 8-mm thick depleted uranium shielded by 80-mm thick steel, using a 6-MeV X-ray beam with a spread of 45% (FWHM) and 10 7 photons in a single shot. The corresponding dose of the X-ray pulse measured in front of the target is ~100 nGy/pulse. Simulations performed using the Monte-Carlo code MCNPX accurately reproduce the experimental results. These simulations also demonstrate that the narrow bandwidth of the Compton X-ray source operating at 6 and 9 MeV leads to a reduction of deposited dose as compared to broadband bremsstrahlung sources with the same end-point energy. The X-ray beam’s inherently low-divergence angle (~mrad) is advantageous and effective for interrogation at standoff distance. Furthermore, these results demonstrate significant benefits of all-laser driven Compton X-rays for shielded radiography.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Controlling Oxidation of Nb in Oxygen Abundant Environments

Modern particle accelerators depend on Superconducting Radio Frequency (SRF) cavities made from high-purity niobium (Nb) to achieve optimal performance, including high quality factors and strong accelerating gradients. However, when exposed to air, niobium naturally forms a complex oxide layer that can introduce surface imperfections and carbon contamination. This work examines an alternative oxidation strategy under oxygen-rich conditions to better regulate the oxide formation process. The ultimate objective is to improve surface uniformity and cleanliness, thereby reducing defect density and enhancing performance. We used Confocal Microscopy, Scanning Electron Microscopy (SEM), and X-Ray Photoelectron Spectroscopy (XPS) to analyze surface changes. We used standard metrics, like Arithmetic Average Roughness (Ra) and Root Mean Square (Rq). Three oxidation methods were applied: short, extended, and a repeated HF and H₂O₂ oxidation process. Preliminary results show promising reductions in carbon contamination and surface defects.

Romero, Juan [Fermilab]↗

Precision X-Band Linac Technologies for Nuclear Photonics Gamma-Ray Sources

Nuclear photonics is an emerging field of research requiring new tools, including high spectral brightness, tunable gamma-ray sources; high photon energy, ultrahigh-resolution crystal spectrometers; and novel detectors. This presentation focuses on the precision linac technology required for Compton scattering gamma-ray light sources, and on the optimization of the laser and electron beam pulse format to achieve unprecedented spectral brightness. Within this context, high-gradient X-band technology will be shown to offer optimal performance in a compact package, when used in conjunction with the appropriate pulse format, and photocathode illumination and interaction laser technologies. The nascent field of nuclear photonics is enabled by the recent maturation of new technologies, including high-gradient X-band electron acceleration, robust fiber laser systems, and hyper-dispersion CPA. Recent work has been performed at LLNL to demonstrate isotope-specific detection of shielded materials via NRF using a tunable, quasi-monochromatic Compton scattering gamma-ray source operating between 0.2 MeV and 0.9 MeV photon energy. This technique is called Fluorescence Imaging in the Nuclear Domain with Energetic Radiation (or FINDER). This work has, among other things, demonstrated the detection of {sup 7}Li shielded by Pb, utilizing gamma rays generated by a linac-driven, laser-based Compton scattering gamma-ray source developed at LLNL. Within this context, a new facility is currently under construction at LLNL, with the goal of generating tunable {gamma}-rays in the 0.5-2.5 MeV photon energy range, at a repetition rate of 120 Hz, and with a peak brightness in the 10{sup 20} photons/(s x mm{sup 2} x mrad{sup 2} x 0.1% bw).

42 ENGINEERING↗

Accelerated Irradiation Testing of Miniature Nuclear Fuel and Cladding Specimens

Qualification of advanced nuclear fuels and materials requires irradiation testing to provide input to predictive models for licensing. Oak Ridge National Laboratory has a long history of performing accelerated irradiation testing and post-irradiation examination (PIE) of miniature material specimens to determine the evolution of microstructure and thermophysical properties, leveraging the High Flux Isotope Reactor, dedicated hot cells, and instruments for handling small, low-level radioactive samples. This work gives a brief overview of irradiation testing of miniature samples to support qualification of advanced fuel cladding materials such as FeCrAl alloys and SiC ceramic matrix composites. More recent work has enabled separate effects irradiation testing of miniature fuel specimens. The small fuel size essentially decouples fuel temperature from fission rate, allowing for highly accelerated testing without large temperature gradients. This paper briefly highlights the new mini fuel irradiation facility and its first set of experiments.

Petrie, Christian↗

LCLS-II SRF Cavity Processing Protocol Development and Baseline Cavity Performance Demonstration

The ”Linac Coherent Light Source-II” Project will construct a 4 GeV CW superconducting RF linac in the first kilometer of the existing SLAC linac tunnel. The baseline design calls for 280 1.3 GHz nine-cell cavities with an average intrinsic quality factor Q0 of 2.7·1010 at 2K and 16 MV/m accelerating gradient. The LCLS-II high Q0 cavity treatment protocol utilizes the reduction in BCS surface resistance by nitrogen doping of the RF surface layer, which was discovered originally at FNAL. Cornell University, FNAL, and TJNAF conducted a joint high Q0 R&D program with the goal of (a) exploring the robustness of the N-doping technique and establishing the LCLS-II cavity high Q0 processing protocol suitable for production use, and (b) demonstrating that this process can reliably achieve LCLS-II cavity specification in a production acceptance testing setting. In this paper we describe the LCLS-II cavity protocol and analyze combined cavity performance data from both vertical and horizontal testing at the three partner labs, which clearly shows that LCLS-II specifications were met, and thus demonstrates readiness for LCLS-II cavity production.

Liepe, M.↗

New RF Control System for the 12 GeV Energy Upgrade of the CEBAF Accelerator at Jefferson Lab

The CEBAF Accelerator at Jefferson Lab presently consists of 50 MeV injector, two anti-parallel superconducting linacs and two arcs for transporting beam between the linacs. By the mid-1990s, the accelerator was providing electrons up to 5.75 GeV. The 12 GeV Upgrade is a major accelerator project aimed at doubling the energy by adding 10 (five per linac) new high gradient cryomodules, each providing 100 MV of field. The new cryomodule will consist of eight 7-cell superconducting cavities operating at an average accelerating gradient of 19.5 MV/m and with an external Q=3.2 x 10^7. The high gradient, very high quality factor and large Lorentz detuning coefficient (KL up to 4) pose significant challenges beyond what the present analog low level RF (LLRF) control systems can handle reliably; therefore, a new digital LLRF control system has been developed. The main highlights of the new RF Control system include: a RF front-end with low temperature drift and good linearity, a large FPGA

43 PARTICLE ACCELERATORS↗

HIGH Q0 AT MEDIUM FIELDS IN Nb3Sn SRF CAVITIES AT 4.2 K

Nb3Sn has proven itself to be a very promising alternative SRF material. With twice the critical temperature of niobium cavities, 1.3 GHz Nb3Sn cavities can achieve quality factors on the order of 1010 even at 4.2 K, significantly reducing cryogenic infrastructure and operational costs. In addition, its large predicted superheating field may allow for maximum accelerating gradients up to twice that of niobium for high energy applications. In this work, we report on new cavity results fromthe CornellNb3Sn SRF program demonstrating a significant improvement in the maximum field achieved with high Q0 in a Nb3Sn cavity. At 4.2 K, accelerating gradients above 16MV/m were obtainedwith Q0 of 8 × 109, showing the potential of this material for future applications. In addition to this result, current limitations are discussed.

Nb3Sn↗

Improved laser-plasma accelerator stability via high-bandwidth longitudinal focal position stabilization of a 100 TW-class laser system

Laser-plasma accelerators (LPAs) offer an attractive alternative to conventional accelerators for the development of compact electron sources and next-generation light sources. Due to orders-of-magnitude larger accelerating gradients, LPAs enable the acceleration of high-brightness electron beams to ultrarelativistic energies in millimeter- to centimeter-scale distances. However, LPA stability is limited by shot-to-shot fluctuations of the driving laser system. Specifically, fluctuations in the final-focus longitudinal position result in correlated instability in LPA electron beam qualities, including total beam charge, average beam energy, and energy spread. We demonstrate active stabilization of the longitudinal focal position for a 100 TW-class laser system. This repetition-rate scalable stabilization system leverages noninvasive wave front monitoring of a copropagating, unamplified kHz pulse train to guide corrective adjustments to the focal position of a 1 Hz amplified drive laser via an upstream telescope on millisecond timescales. In this demonstration, the approach limits standard deviation fluctuations of the amplified drive beam’s longitudinal focal position to ±0.22⁢ mm (representing at least a 53% reduction), achieved with a correction bandwidth that reaches the Nyquist frequency limit. Consequently, we observe marked improvements in both long-term and shot-to-shot LPA stability in terms of charge and spectrum.

Beam control↗

ADVANCED X-BAND TEST ACCELERATOR FOR HIGH BRIGHTNESS ELECTRON AND GAMMA RAY BEAMS

In support of Compton scattering gamma-ray source efforts at LLNL, a multi-bunch test stand is being developed to investigate accelerator optimization for future upgrades. This test stand will enable work to explore the science and technology paths required to boost the current 10 Hz monoenergetic gamma-ray (MEGa-Ray) technology to an effective repetition rate exceeding 1 kHz, potentially increasing the average gamma-ray brightness by two orders of magnitude. Multiple bunches must be of exceedingly high quality to produce narrow-bandwidth gamma-rays. Modeling efforts will be presented, along with plans for a multi-bunch test stand at LLNL. The test stand will consist of a 5.5 cell X-band rf photoinjector, single accelerator section, and beam diagnostics. The photoinjector will be a high gradient standing wave structure, featuring a dual feed racetrack coupler. The accelerator will increase the electron energy so that the emittance can be measured using quadrupole scanning techniques. Multi-bunch diagnostics will be developed so that the beam quality can be measured and compared with theory. Design will be presented with modeling simulations, and layout plans.

42 ENGINEERING↗

Advanced X-Band Test Accelerator for High Brightness Electron and Gamma Ray Beams

In support of Compton scattering gamma-ray source efforts at LLNL, a multi-bunch test stand is being developed to investigate accelerator optimization for future upgrades. This test stand will enable work to explore the science and technology paths required to boost the current 10 Hz monoenergetic gamma-ray (MEGa-Ray) technology to an effective repetition rate exceeding 1 kHz, potentially increasing the average gamma-ray brightness by two orders of magnitude. Multiple bunches must be of exceedingly high quality to produce narrow-bandwidth gamma-rays. Modeling efforts will be presented, along with plans for a multi-bunch test stand at LLNL. The test stand will consist of a 5.5 cell X-band rf photoinjector, single accelerator section, and beam diagnostics. The photoinjector will be a high gradient standing wave structure, featuring a dual feed racetrack coupler. The accelerator will increase the electron energy so that the emittance can be measured using quadrupole scanning techniques. Multi-bunch diagnostics will be developed so that the beam quality can be measured and compared with theory. Design will be presented with modeling simulations, and layout plans.

43 PARTICLE ACCELERATORS↗

An X-Band Ultra-High Gradient Photoinjector

High brightness beams appealing for XFELs and UEM essentially imply a high current and a low emittance. To obtain such beams we propose to raise the accelerating voltage in the gun mitigating repealing Coulomb forces. An ultra-high gradient is achieved utilizing a short-pulse technology. We have designed a room temperature X-band 1,5 cell gun that is able to inject 4 MeV, 100 pC bunches with as low as 0.15 mcm normalized transverse emittance. The gun is operated with as high gradients as 400 MV/m and fed by 200 MW, 10 ns RF pulses generated with Argonne Wakefield Accelerator (AWA) power extractor. We report results of low RF power tests, laser alignment test results, and successful gun conditioning results carried out at nominal RF power.