Search NASA⌕ Search

SEARCH · Search NASA

Results for “High loading rate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Anomolous Fatigue Crack Growth Phenomena in High-Strength Steel

The growth of a fatigue crack through a material is the result of a complex interaction between the applied loading, component geometry, three-dimensional constraint, load history, environment, material microstructure and several other factors. Previous studies have developed experimental and computational methods to relate the fatigue crack growth rate to many of the above conditions, with the intent of discovering some fundamental material response, i.e. crack growth rate as a function of something. Currently, the technical community uses the stress intensity factor solution as a simplistic means to relate fatigue crack growth rate to loading, geometry and all other variables. The stress intensity factor solution is a very simple linear-elastic representation of the continuum mechanics portion of crack growth. In this paper, the authors present fatigue crack growth rate data for two different high strength steel alloys generated using standard methods. The steels exhibit behaviour that appears unexplainable, compared to an aluminium alloy presented as a baseline for comparison, using the stress intensity factor solution.

Forth, Scott C.↗

Quasi-Uniform High Speed Foam Crush Testing Using a Guided Drop Mass Impact

A relatively simple method for measuring the dynamic crush response of foam materials at various loading rates is described. The method utilizes a drop mass impact configuration with mass and impact velocity selected such that the crush speed remains approximately uniform during the entire sample crushing event. Instrumentation, data acquisition, and data processing techniques are presented, and limitations of the test method are discussed. The objective of the test method is to produce input data for dynamic finite element modeling involving crash and energy absorption characteristics of foam materials.

Jones, Lisa E.↗

Micron Size NaCrO 2 Particles Enable High‐loading Dry‐processed Electrode for Sodium Ion Batteries

Dry-process fabrication using fibrillatable binder is emerging as a promising method to produce high-loading electrodes for energy storage applications, favored by its cost-efficiency and eco-friendliness. While previous studies have demonstrated the advantages of dry process over the traditional slurry method, there remains a gap in understanding how the particle size of active materials influences the mechanical and electrochemical performance of dry electrodes. In this study, four different particle size NaCrO 2 materials (Average size, S-NCO: 0.6 µm, M1-NCO 1.5 µm, M2-NCO: 4.4 µm, and L-NCO: 9.9 µm) are synthesized to investigate the effect of particle size on dry-processed high-loading electrodes. The findings reveal that the larger micron-sized (>4.4 µm) NCO dry films exhibit significantly improved tensile strength and electrochemical performance, primarily ascribed to the low film porosity, abundant inter-particle connection by the binder, comprehensive carbon coverage, and efficient percolation of the conductive pathway. Notably, a full cell incorporated with a high loading (5.2 mAh cm −2 ) and high active material ratio (96.5 wt.%) L-NCO film electrode demonstrates promising cycling stability and rate capability. Furthermore, these results provide valuable insights regarding the design and fabrication of dry-processed electrodes for future energy storage applications.

25 ENERGY STORAGE↗

Modeling Electrochemical and Rheological Characteristics of Suspension-Based Electrodes for Redox Flow Cells

Flowable suspension-based electrodes (FSEs) have gained attention in recent years, as the integration of solid materials into electrochemical flow cells can offer improved performance and flexible operation. However, under conditions that engender favorable electrochemical properties (e.g., high particle loading, high conductivity, high surface area), FSEs can exhibit non-Newtonian characteristics that impose large pumping losses and flow-dependent transport rates. These multifaceted trade-offs motivate the use of models to broadly explore scaling relationships and better understand design rules for electrochemical devices. To this end, we present a one-dimensional model, integrating porous electrode theory with FSE rheology as well as flow-dependent electron and mass transport under pressure-driven flow. We study FSE behavior as a function of material properties and operating conditions, identifying key dimensionless groups that describe the underlying physical processes. We assess flow cell performance by quantifying electrode polarization and relative pumping losses, establishing generalized property-performance relationships for FSEs. Importantly, we expound relevant operating regimes—based on a subset of dimensionless groups—that inform practical operating envelopes, ultimately helping to guide FSE and cell engineering for electrochemical systems.

25 ENERGY STORAGE↗

Hydrogen gas embrittlement and the disc pressure test

A disc pressure test has been used to study the influenced of a hydrogen gas environment on the mechanical properties of three high strength superalloys, Inconel 718, L-605 and A-286, in static and dynamic conditions. The influence of the hydrogen pressure, loading rate, temperature, mechanical and thermal fatigue has investigated. The permeation characteristics of Inconel 718 have been determined in collaboration with the French AEC. The results complemented by a fractographic study are consistent either with a stress-sorption or with an internal embrittlement type of mechanism.

Bachelet, E. J.↗

Digital transmitter for data bus communications system

An improved digital transmitter for transmitting serial pulse code modulation (pcm) data at high bit rates over a transmission line is disclosed. When not transmitting, the transmitter features a high output impedance which prevents the transmitter from loading the transmission line. The pcm input is supplied to a logic control circuit which produces two discrete logic level signals which are supplied to an amplifier. The amplifier, which is transformer coupled to the output isolation circuitry, converts the discrete logic level signals to two high current level, ground isolated signals in the secondary windings of the coupling transformer. The latter signals are employed as inputs to the isolation circuitry which includes two series transistor pairs operating into a hybrid transformer functioning to isolate the transmitter circuitry from the transmission line.

Proch, G. E.↗

Influence of load interactions on crack growth as related to state of stress and crack closure

Fatigue crack propagation (FCP) after an application of a low-high loading sequence was investigated as a function of specimen thickness and crack closure. No load interaction effects were detected for specimens in a predominant plane strain state. However, for the plane stress specimens, initially high FCP rates after transition to a higher stress intensity range were observed. The difference in observed behavior was explained by examining the effect of the resulting closure stress intensity values on the effective stress intensity range.

Telesman, J.↗

Test Rig for Evaluating Active Turbine Blade Tip Clearance Control Concepts

Improved blade tip sealing in the high pressure compressor and high pressure turbine can provide dramatic improvements in specific fuel consumption, time-on-wing, compressor stall margin and engine efficiency as well as increased payload and mission range capabilities of both military and commercial gas turbine engines. The preliminary design of a mechanically actuated active clearance control (ACC) system for turbine blade tip clearance management is presented along with the design of a bench top test rig in which the system is to be evaluated. The ACC system utilizes mechanically actuated seal carrier segments and clearance measurement feedback to provide fast and precise active clearance control throughout engine operation. The purpose of this active clearance control system is to improve upon current case cooling methods. These systems have relatively slow response and do not use clearance measurement, thereby forcing cold build clearances to set the minimum clearances at extreme operating conditions (e.g., takeoff, re-burst) and not allowing cruise clearances to be minimized due to the possibility of throttle transients (e.g., step change in altitude). The active turbine blade tip clearance control system design presented herein will be evaluated to ensure that proper response and positional accuracy is achievable under simulated high-pressure turbine conditions. The test rig will simulate proper seal carrier pressure and temperature loading as well as the magnitudes and rates of blade tip clearance changes of an actual gas turbine engine. The results of these evaluations will be presented in future works.

Lattime, Scott B.↗

Exploration Extravehicular Mobility Unit (xEMU) 11 Foot Vacuum Chamber Upgrades Test Results

The Exploration Extravehicular Mobility Unit (xEMU) uncrewed 11 foot vacuum chamber testing evaluated the capabilities of the 11 foot vacuum chamber facility to support advanced spacesuit testing. The government reference design xEMU spacesuit provided a high-fidelity test article to demonstrate 11 foot vacuum chamber capabilities which included: gas loading of the chamber at varying simulated metabolic rates and open loop suit abort operations, Intravehicular Activity (IVA) vacuum access, consumables recharge, IVA vehicle-provided thermal loop cooling, and IVA vehicle-provided power. To demonstrate the xEMU airlock operations transitioning from IVA to EVA conditions without a test subject in the suit, test support equipment was developed to remotely actuate both the Exploration, Servicing, and Cooling Umbilical (ESCU) and the vacuum access umbilical. This test also evaluated the performance of the Exploration Portable Life Support System (xPLSS) at vacuum conditions. Data was collected and analyzed for carbon dioxide (CO2) scrubbing performance of the Rapid Cycle Amine (RCA) swingbed, for thermal regulation performance of the Suit Water Membrane Evaporator (SWME), and for sensor performance across the xPLSS. This paper will detail the findings of the testing performed with these upgrades which discussed previously laid out in ICES-2025-342.

Robert F Marsch↗

Exploration Extravehicular Mobility Unit 11 Foot Vacuum Chamber Upgrades Test Results

The Exploration Extravehicular Mobility Unit (xEMU) uncrewed 11 foot vacuum chamber testing evaluated the capabilities of the 11 foot vacuum chamber facility to support advanced spacesuit testing. The government reference design xEMU spacesuit provided a high-fidelity test article to demonstrate 11 foot vacuum chamber capabilities which included: gas loading of the chamber at varying simulated metabolic rates and open loop suit abort operations, Intravehicular Activity (IVA) vacuum access, consumables recharge, IVA vehicle-provided thermal loop cooling, and IVA vehicle-provided power. To demonstrate the xEMU airlock operations transitioning from IVA to EVA conditions without a test subject in the suit, test support equipment was developed to remotely actuate both the Exploration, Servicing, and Cooling Umbilical (ESCU) and the vacuum access umbilical. This test also evaluated the performance of the Exploration Portable Life Support System (xPLSS) at vacuum conditions. Data was collected and analyzed for carbon dioxide (CO2) scrubbing performance of the Rapid Cycle Amine (RCA) swingbed, for thermal regulation performance of the Suit Water Membrane Evaporator (SWME), and for sensor performance across the xPLSS. This paper will detail the findings of the testing performed with these upgrades which discussed previously laid out in ICES-2025-342.

Robert Marsch↗

Measurement Adequacy for Monitoring Data Center Oscillations

Artificial intelligence (AI) training data centers with periodic load profiles can induce sustained grid oscillations across a wide frequency range, making accurate monitoring essential for reliable power system operation. This report evaluates the adequacy of existing measurement systems for monitoring such oscillations, focusing on phasor measurement units (PMUs) and point-on-wave (POW) measurement systems. The analysis shows that while PMUs are highly effective for monitoring low-frequency electromechanical oscillations, they have inherent limitations in accurately representing higher-frequency oscillations due to constraints imposed by reporting rates and the bandwidth of phasor estimation filters. Even when configured with higher reporting rates, the filtering inherent in the phasor estimation process can significantly attenuate oscillation magnitudes, potentially leading to underestimation of oscillatory behavior. This has important implications for compliance and performance monitoring of large loads. To address the limitations associated with PMU-based monitoring, the report examines the use of high-resolution POW measurements, which can capture oscillations across a broader frequency range. However, continuous POW monitoring introduces practical challenges related to large data volumes, communication bandwidth, and real-time data processing. For this reason, the report also discusses emerging approaches that use POW measurements as a complementary capability alongside PMUs to improve observability of oscillations from large data center loads.

47 OTHER INSTRUMENTATION↗

The Global Fingerprint of Modern Ice-Mass Loss on 3-D Crustal Motion

Crustal motion generated by rapid ice-mass loss from Earth's glaciers and ice sheets has previously been considered in Global Navigational Satellite System (GNSS) analyses and numerical models across regions of ice retreat. However, the fingerprint of ice-mass loss is not limited to glaciated areas, but is characterized by a global pattern of 3-D crustal deformation. We compute “far-field” vertical and horizontal deformation rates that occurred in response to early 21st century mass flux from the Greenland and Antarctic Ice Sheets, global glaciers and ice caps, and associated ocean loading. We demonstrate that mass changes in the Greenland Ice Sheet and high latitude glacier systems each generated average crustal motion of 0.1–0.4 mm/yr across much of the Northern Hemisphere, with significant year-to-year variability in magnitude and direction. Horizontal motions associated with ice-mass loss exceed vertical rates in many far-field areas, and both should be considered in future analysis of GNSS measurements.

58 GEOSCIENCES↗

Characterizing peak electricity demand for U.S. households: an assessment of end-use loads and demand factors

Understanding household peak electricity demand is critical to evaluate the technical need for electrical infrastructure upgrades. This study characterizes peak loads for existing and new equipment using metered data from a convenience sample of 11,940 U.S. dwellings from four sources, including 911 from two sources with end-use metering. After standardized data cleaning and labeling, we derived descriptive statistics for key metrics, such as maximum demand and demand factors, and developed predictive models relating 60- to 15-min demand for the National Electrical Code (NEC). Mean 15-min maximum demand was 9.7 kW (median 9.0 kW; IQR 7.0–11.5 kW, 95% CI 9.6–9.8 kW), indicating spare capacity in 98% of homes with hypothetical 100 A panels. Maximum demand increased with floor area and number of high-demand loads. Dwelling maximum demand was driven by higher-power, longer-duration heating appliances and vehicle charging, while most user-operated appliances contributed little. Demand factors are used to account for how most devices contribute less than their rated power to maximum demand. Existing load mean demand factors (28%; median 10%; IQR 0–58%; CI 28–29%) were higher than those for new loads (21%; median 7%; IQR 0–35%; CI 20–21%), because new loads changed the timing and magnitude of maximum demand. New high-demand loads had higher than average demand factors (40–60%). Whole dwelling demand factors support the NEC's 40% assumption, but they challenge its conservative 100% treatment of new HVAC. We propose a data-driven 50% demand factor for new equipment, which would align with metered data, improve affordability, and modernize electrical codes.

Appliances↗

Lubrication of high-speed, large bore tapered-roller bearings

The performance of 120.65-mm- (4.75-in.-) bore tapered-roller bearings was investigated at shaft speeds up to 15,000 rpm (18,000 DN). Temperature distribution and bearing heat generation were determined as a function of shaft speed, radial and thrust loads, lubricant flow rate, and lubricant inlet temperature. Lubricant was supplied either by jets or by a combination of holes through the cone directly to the cone-rib contact and jets at the roller small-end side. Cone-rib lubrication significantly improved high-speed tapered-roller bearing performance, yielding lower cone-face temperatures and lower power loss and allowing lower lubricant flow rates for a given speed condition. Bearing temperatures increased with increased shaft speed and decreased with increased lubricant flow rate. Bearing power loss increased with increased shaft speed and increased lubricant flow rate.

Parker, R. J.↗

Aerothermal evaluation of a spherically blunted body with a trapezoidal cross section in the Langley 8-foot high-temperature tunnel

A model to be used in the flow studies and curved Thermal Protection System (TPS) evaluations was tested in the Langley 8 Foot High-Temperature Tunnel at a nominal Mach number of 6.8. The purpose of the study was to define the surface pressure and heating rates at high angles of attack (in support of curved metallic TPS studies) and to determine the conditions for which the model would be suitable as a test bed for aerothermal load studies. The present study was conducted at a nominal total temperature of 2400 and 3300 R, dynamic pressures from 2.3 to 10.9 psia, and free-stream Reynolds numbers from 4000,000 to 1,700,000/ft. The measurements consisted primarily of surface pressure and cold-wall (530 R) heating rates. Qualitative comparisons between predictions and data show that for this configuration, aerothermal tests should be limited to angles of attack between 10 and -10 degrees. Outside this range, the effects of free-stream flow nonuniformity appear in the data, as a result of the long length of the model. However, for TPS testing, this is not a concern and tests can be performed at angles of attack ranging from 20 to -20 degrees. Laminar and naturally turbulent boundary layers are available over limited ranges of conditions.

Albertson, Cindy W.↗

High‐Rate Polymeric Redox in MXene‐Based Superlattice‐Like Heterostructure for Ammonium Ion Storage

Abstract Achieving both high redox activity and rapid ion transport is a critical and pervasive challenge in electrochemical energy storage applications. This challenge is significantly magnified when using large‐sized charge carriers, such as the sustainable ammonium ion (NH 4 + ). A self‐assembled MXene/n‐type conjugated polyelectrolyte (CPE) superlattice‐like heterostructure that enables redox‐active, fast, and reversible ammonium storage is reported. The superlattice‐like structure persists as the CPE:MXene ratio increases, accompanied by a linear increase in the interlayer spacing of MXene flakes and a greater overlap of CPEs. Concurrently, the redox activity per unit of CPE unexpectedly intensifies, a phenomenon that can be explained by the enhanced de‐solvation of ammonium due to the increased volume of 3 Å‐sized pores, as indicated by molecular dynamic simulations. At the maximum CPE mass loading (MXene:CPE ratio = 2:1), the heterostructure demonstrates the strongest polymeric redox activity with a high ammonium storage capacity of 126.1 C g −1 and a superior rate capability at 10 A g −1 . This work unveils an effective strategy for designing tunable superlattice‐like heterostructures to enhance redox activity and achieve rapid charge transfer for ions beyond lithium.

36 MATERIALS SCIENCE↗

Lithium promotion of Pt/m-ZrO 2 catalysts for low temperature water-gas shift

Low temperature water-gas shift (LTS) is an important reaction occurring in a fuel processor for producing and purifying hydrogen. Platinum supported on m-ZrO 2 belongs to a family of catalysts consisting of metal nanoparticles and an active partially reducible oxide, with the catalysis proposed to occur at the boundary between metal particles and the support. In this investigation, increasing the loading of lithium dopant increased the LTS rate up to 0.54 wt % lithium, where conversion was 2.4 times that of the unpromoted catalyst at 260°C. Further increases in lithium loading up to 1.5 wt % decreased the rate, although it remained higher than that of the unpromoted catalyst. Infrared spectroscopy and CO 2 temperature programmed desorption experiments showed three effects with increasing lithium loading: (1) lithium promoter weakened the C–H bond of formate, the proposed rate limiting step of the interfacial surface formate mechanism; (2) high levels of lithium suppressed the platinum site capacity required for hydrogen transfer; and (3) high levels of lithium increased catalyst basicity. Aspects (2) and (3) tended to inhibit desorption of product CO 2 , an acidic molecule the removal of which is metal-catalyzed. XANES and XPS experiments revealed that electron transfer to enrich Pt nanoparticles is unlikely the root cause of C–H bond weakening in formate. However, other electronic effects (e.g., electrostatic effects or molecular rearrangement due to enhanced basicity) were not ruled out.

08 HYDROGEN↗

Anisotropic strength behavior of single-crystal TATB

High-rate strength behavior plays an important role in the shock initiation of high explosives, with plastic deformation serving to localize heat into hot spots and as a mechanochemical means to enhance reactivity. Recent simulations predict that detonation-like shocks produce highly reactive nanoscale shear bands in the layered crystalline explosive TATB (1,3,5-triamino-2,4,6-trinitrobenzene), but the thresholds leading to this response are poorly understood. We utilize molecular dynamics to simulate the high-rate compressive stress–strain response of TATB, with a focus on understanding flow behavior. Here, the dependence of strength on pressure and loading axis (crystal orientation) is explored. The deformation mechanisms fall broadly into two categories, with compression along crystal layers activating a buckling/twinning mode and compression normal to the layers producing nanoscale shear bands. Despite the complexity of the underlying mechanisms, the crystal exhibits relatively straightforward stress–strain curves. Most of the crystal orientations studied show rapid strain softening following the onset of yielding, which settles to a steady flow state. Trajectories are analyzed using five metrics for local states and structural order, but most of these metrics yield similar distributions for these deformation mechanisms. On the other hand, a recently proposed measure of intramolecular strain energy is found to most cleanly distinguish between these mechanisms, while also providing a plausible connection with mechanochemically accelerated decomposition kinetics. Localization of intramolecular strain energy is found to depend strongly on crystal orientation and pressure.

36 MATERIALS SCIENCE↗