At least 379 records · Page 21

A Preliminary Study on the Toxic Combustion Products Testing of Polymers Used in High-Pressure Oxygen Systems

One likely cause of polymer ignition in a high-pressure oxygen system is adiabatic-compression heating of polymers caused by pneumatic impact. Oxidative _ pyrolysis or combustion of polymers in a high-pressure oxygen system could generate toxic gases. This paper reports the preliminary results of toxic combustion product testing of selected polymers in a pneumatic-impact test system. Five polymers commonly used in high-pressure oxygen systems, Nylon 6/6, polychlorotrifluoroethylene (CTFE), polytetrafluoroethylene (PTFE), fluoroelastomer (Viton(TradeMark) A), and nitrile rubber (Buna N), were tested in a pneumatic-impact test system at 2500- or 3500-psia oxygen pressure. The polymers were ignited and burned, then combustion products were collected in a stainless-steel sample bottle and analyzed by GC/MS/IRD, GC/FID, and GC/Methanizer/FID. The results of adiabatic-compression tests show that combustion of hydrocarbon polymers, nitrogen-containing polymers, and halogenated polymers in high-pressure oxygen systems are relatively complete. Toxicity of the combustion product gas is presumably much lower than the combustion product gas generated from ambient-pressure oxygen (or air) environments. The NASA-Lewis equilibrium code was used to determine the composition of combustion product gas generated from a simulated, adiabatic-compression test of nine polymers. The results are presented and discussed.

Hshieh, Fu-Yu↗

High-energy (> 70 KeV) x-ray conversion efficiency measurement on the ARC laser at the National Ignition Facility

Here, the Advanced Radiographic Capability (ARC) laser system at the National Ignition Facility (NIF) is designed to ultimately provide eight beamlets with a pulse duration adjustable from 1 to 30 ps, and energies up to 1.5 kJ per beamlet. Currently, four beamlets have been commissioned. In the first set of 6 commissioning target experiments, the individual beamlets were fired onto gold foil targets with energy up to 1 kJ per beamlet at 20–30 ps pulse length. The x-ray energy distribution and pulse duration were measured, yielding energy conversion efficiencies of 4–9 × 10 –4 for x-rays with energies greater than 70 keV. With greater than 3 J of such x-rays, ARC provides a high-precision x-ray backlighting capability for upcoming inertial confinement fusion and high-energy-density physics experiments on NIF.

42 ENGINEERING↗

Catalytic Microtube Rocket Igniter

Devices that generate both high energy and high temperature are required to ignite reliably the propellant mixtures in combustion chambers like those present in rockets and other combustion systems. This catalytic microtube rocket igniter generates these conditions with a small, catalysis-based torch. While traditional spark plug systems can require anywhere from 50 W to multiple kW of power in different applications, this system has demonstrated ignition at less than 25 W. Reactants are fed to the igniter from the same tanks that feed the reactants to the rest of the rocket or combustion system. While this specific igniter was originally designed for liquid methane and liquid oxygen rockets, it can be easily operated with gaseous propellants or modified for hydrogen use in commercial combustion devices. For the present cryogenic propellant rocket case, the main propellant tanks liquid oxygen and liquid methane, respectively are regulated and split into different systems for the individual stages of the rocket and igniter. As the catalyst requires a gas phase for reaction, either the stored boil-off of the tanks can be used directly or one stream each of fuel and oxidizer can go through a heat exchanger/vaporizer that turns the liquid propellants into a gaseous form. For commercial applications, where the reactants are stored as gases, the system is simplified. The resulting gas-phase streams of fuel and oxidizer are then further divided for the individual components of the igniter. One stream each of the fuel and oxidizer is introduced to a mixing bottle/apparatus where they are mixed to a fuel-rich composition with an O/F mass-based mixture ratio of under 1.0. This premixed flow then feeds into the catalytic microtube device. The total flow is on the order of 0.01 g/s. The microtube device is composed of a pair of sub-millimeter diameter platinum tubes connected only at the outlet so that the two outlet flows are parallel to each other. The tubes are each approximately 10 cm long and are heated via direct electric resistive heating. This heating brings the gasses to their minimum required ignition temperature, which is lower than the auto-thermal ignition temperature, and causes the onset of both surface and gas phase ignition producing hot temperatures and a highly reacting flame. The combustion products from the catalytic tubes, which are below the melting point of platinum, are injected into the center of another combustion stage, called the primary augmenter. The reactants for this combustion stage come from the same source but the flows of non-premixed methane and oxygen gas are split off to a secondary mixing apparatus and can be mixed in a near-stoichiometric to highly lean mixture ratio. The primary augmenter is a component that has channels venting this mixed gas to impinge on each other in the center of the augmenter, perpendicular to the flow from the catalyst. The total crosssectional area of these channels is on a similar order as that of the catalyst. The augmenter has internal channels that act as a manifold to distribute equally the gas to the inward-venting channels. This stage creates a stable flame kernel as its flows, which are on the order of 0.01 g/s, are ignited by the combustion products of the catalyst. This stage is designed to produce combustion products in the flame kernel that exceed the autothermal ignition temperature of oxygen and methane.

Schneider, Steven J.↗

System and method for control of compression in internal combustion engine via compression ratio and elastic piston

The present disclosure relates to a system for controlling ignition of an air/fuel mixture intake charge directed into an internal combustion engine. The system may have a longitudinally movable inner cylinder liner configured to fit within a cylinder wall portion of an internal combustion engine, and able to receive a piston of the engine therein. A portion of the inner cylinder liner defines an internal volume forming a combustion chamber, and the internal volume controls a compression ratio of the cylinder. The system also has a cylinder head assembly operatively associated with the inner cylinder liner and able to move linearly to cause longitudinal displacement of the inner cylinder liner relative to the cylinder wall portion. This enables the volume of the combustion chamber to be further varied, to thus further vary the compression ratio.

Flowers, Daniel L.↗

Compatibility Studies of Hydrogen Peroxide and a New Hypergolic Fuel Blend

Several preliminary materials compatibility studies have been conducted to determine the practicality of a new hypergolic fuel system. Hypergolic fuel ignites spontaneously as the oxidizer decomposes and releases energy in the presence of the fuel. The bipropellant system tested consists of high-test hydrogen peroxide (HTP) and a liquid fuel blend consisting of a hydrocarbon fuel, an ignition enhancer and a transition metal catalyst. In order for further testing of the new fuel blend to take place, some basic materials compatibility and HTP decomposition studies must be accomplished. The thermal decomposition rate of HTP was tested using gas evolution and isothermal microcalorimetry (IMC). Materials were analyzed for compatibility with hydrogen peroxide including a study of the affect welding has on stainless steel elemental composition and its relation to HTP decomposition. Compatibility studies of valve materials in the fuel blend were performed to determine the corrosion resistance of the materials.

Baldridge, Jennifer↗

Injection laser system for Advanced Radiographic Capability using chirped pulse amplification on the National Ignition Facility

We report on the design, performance, and qualification of the injection laser system designed to deliver joule-level chirped pulse beamlets arranged in dual rectangular beam formats into two main laser amplifier beamlines of the National Ignition Facility. The system is designed to meet the requirements of the Advanced Radiographic Capability upgrade with features that deliver performance, adjustability, and long-term reliability.

47 OTHER INSTRUMENTATION↗

Physically-based control-oriented modeling for turbocharged stoichiometric spark-ignited engine with cooled EGR and flexible VVT systems

Accurate estimation and prediction of engine gas exchange system and in-cylinder conditions are critical for spark-ignited engine control and diagnostic algorithm development. In this paper, a physically-based, control-oriented model for a 2.8 l turbocharged, variable valve timing (VVT) and low pressure (LP) exhaust gas recirculation (EGR)-utilizing SI engine was developed. The model includes the impact of modulation to any combination of 10 actuators, including the throttle valve, compressor bypass valve, fueling rate, waste-gate, LP EGR valve, number of deactivated cylinders, intake valve open (IVO) timing, intake valve close (IVC) timing, exhaust valve open (EVO) timing and exhaust valve close (EVC) timing. The accuracy of the model in capturing engine dynamics was demonstrated by validating it against high-fidelity engine GT-Power simulation results for various drive cycles, particularly emphasizing elevated loads. In comparison to the open literature, novel contributions of the effort described in this paper includes in-cylinder gas composition modeling and turbine-out pressure estimation.

Zhang, Xu↗

Development of a Flex-Fuel Mixing Controlled Combustion System for Gasoline/Ethanol Blends Enabled by Prechamber Ignition

This project demonstrated a heavy-duty engine converted from using diesel fuel to a flex-fuel engine that can use any blend of gasoline and ethanol. The combustion system is an innovative concept that allows very low cetane fuels to be used in a conventional mixing-controlled combustion (MCC) strategy without auxiliary heating, changes to the basic engine structure, or advanced controls.

09 BIOMASS FUELS↗

EVALUATION OF CONTROLLED END GAS AUTO IGNITION WITH EXHAUST GAS RECIRCULATION IN A STOICHIOMETRIC, SPARK IGNITED, NATURAL GAS ENGINE

Many stationary and heavy-duty on-road natural gas fueled engines today operate under stoichiometric conditions with a three-way catalyst. The disadvantage of stoichiometric natural gas engines compared to lean-burn natural gas and diesel engines is lower efficiency, resulting primarily from lower power density and compression ratio. Exhaust gas recirculation (EGR) coupled with advanced combustion controls can enable operation with higher compression ratio and power density, which yields higher efficiency. This also results in engine operation between the limits of knock and misfire. Operation between these limits has been named controlled end gas auto-ignition (C-EGAI) and can be used to improve the brake efficiency of the engine. Various methods of cylinder pressure-based knock quantification were explored to implement C-EGAI. The indicated quantification methods are used for the implementation of a control scheme for C-EGAI with a relation to the fractional heat release due to auto-ignition. A custom EGR system was built and the effect of EGR on the performance of a stochiometric, spark ignited, natural gas engine is evaluated. C-EGAI is implemented and the optimal parameters are determined for peak performance under EGR and C-EGAI conditions. In this study, knock detection is used for the recognition, magnitude, and location of the auto-ignition events. Cylinder pressure-based knock detection was the primary method for determining the occurrence and location of knock but was also used for implementing the ignition control scheme for controlled end gas auto-ignition. The combustion intensity metric (CIM) enabled parametric ignition timing control which allowed for the creation of a relationship between fractional heat release due to auto-ignition and CIM. Many stationary and heavy-duty on-road natural gas fueled engines today operate under stoichiometric conditions with a three-way catalyst. The disadvantage of stoichiometric natural gas engines compared to lean-burn natural gas and diesel engines is lower efficiency, resulting primarily from lower power density and compression ratio. Exhaust gas recirculation (EGR) coupled with advanced combustion controls can enable operation with higher compression ratio and power density, which yields higher efficiency. This also results in engine operation between the limits of knock and misfire. Operation between these limits has been named controlled end gas auto-ignition (C-EGAI) and can be used to improve the brake efficiency of the engine. Various methods of cylinder pressure-based knock quantification were explored to implement C-EGAI. The indicated quantification methods are used for the implementation of a control scheme for C-EGAI with a relation to the fractional heat release due to auto-ignition. A custom EGR system was built and the effect of EGR on the performance of a stochiometric, spark ignited, natural gas engine is evaluated. C-EGAI is implemented and the optimal parameters are determined for peak performance under EGR and C-EGAI conditions. In this study, knock detection is used for the recognition, magnitude, and location of the auto-ignition events. Cylinder pressure-based knock detection was the primary method for determining the occurrence and location of knock but was also used for implementing the ignition control scheme for controlled end gas auto-ignition. The combustion intensity metric (CIM) enabled parametric ignition timing control which allowed for the creation of a relationship between fractional heat release due to auto-ignition and CIM. Both exhaust gas recirculation and controlled end gas auto-ignition were analyzed with a cooperative fuel research (CFR) engine modified for boosted fuel/air intake. The data was interpreted to provide a proper evaluation of unique analytical methods to quantify the results of C_EGAI and characterize the live auto-ignition events. The control variables for this method of C-EGAI were optimized with EGR conditions to generate the point of peak performance on the CFR engine under stoichiometric, spark ignited, natural gas conditions.

Bayliff, Scott Michael↗

12-NIF Dedication: Concluding Remarks and Video

The National Ignition Facility, the world's largest laser system, was dedicated at a ceremony on May 29, 2009 at Lawrence Livermore National Laboratory. These are the concluding remarks by NIF Director Edward Moses, and a brief video presentation.

99 GENERAL AND MISCELLANEOUS↗

Low soot stoichiometric compression-ignition combustion

A combustion system including a combustion mechanism that injects oxygenated fuel into a combustion chamber. The oxygenated fuel mixes with the intake air in the combustion chamber where the air-fuel ratio in a portion of the combustion chamber is stoichiometric. The combustion mechanism includes an ignition mechanism that ignites the air-fuel mixture that generates a threshold number of particulates during combustion of the air-fuel mixture. The combustion system further includes an exhaust gas recirculation (EGR) device that recirculates a portion of the exhaust gases back into the combustion chamber. The EGR device recirculates the portion of the exhaust to lower combustion temperature resulting in reduced amount of nitrogen oxide in the exhaust. The combustion system further includes a three-way catalytic converter in line with the exhaust channel to convert a second portion of the exhaust gases, leading to lower pollutant emissions than conventional combustion systems.

Pickett, Lyle M.↗

Piezoelectrically Initiated Pyrotechnic Igniter

This innovation consists of a pyrotechnic initiator and piezoelectric initiation system. The device will be capable of being initiated mechanically; resisting initiation by EMF, RF, and EMI (electromagnetic field, radio frequency, and electromagnetic interference, respectively); and initiating in water environments and space environments. Current devices of this nature are initiated by the mechanical action of a firing pin against a primer. Primers historically are prone to failure. These failures are commonly known as misfires or hang-fires. In many cases, the primer shows the dent where the firing pin struck the primer, but the primer failed to fire. In devices such as "T" handles, which are commonly used to initiate the blowout of canopies, loss of function of the device may result in loss of crew. In devices such as flares or smoke generators, failure can result in failure to spot a downed pilot. The piezoelectrically initiated ignition system consists of a pyrotechnic device that plugs into a mechanical system (activator), which on activation, generates a high-voltage spark. The activator, when released, will strike a stack of electrically linked piezo crystals, generating a high-voltage, low-amperage current that is then conducted to the pyro-initiator. Within the initiator, an electrode releases a spark that passes through a pyrotechnic first-fire mixture, causing it to combust. The combustion of the first-fire initiates a primary pyrotechnic or explosive powder. If used in a "T" handle, the primary would ramp the speed of burn up to the speed of sound, generating a shock wave that would cause a high explosive to go "high order." In a flare or smoke generator, the secondary would produce the heat necessary to ignite the pyrotechnic mixture. The piezo activator subsystem is redundant in that a second stack of crystals would be struck at the same time with the same activation force, doubling the probability of a first strike spark generation. If the first activation fails to ignite, the device is capable of multiple attempts. Another unique aspect is in the design of the pyrotechnic device. There is an electrode that aids the generation of a directed spark and the use of a conductive matrix to support the first-fire material so that the spark will penetrate to the second electrode.

Quince, Asia↗

Computational analysis of flame initiation, quenching, and re-ignition in a prechamber natural gas engine under varying EGR-dilution levels

The on-road natural-gas (NG) fueled transportation relies on stoichiometric spark-ignition engines for the advantages of simple after-treatment system despite the efficiency penalty relative to lean-burn combustion strategies. Exhaust gas recirculation (EGR) has the potential to reduce this efficiency gap at low to moderate loads without the need for complex lean-exhaust aftertreatment systems. However, EGR dilution leads to reduced combustion stability and increased cycle-to-cycle variability. A promising technology that has the potential to achieve reliable operation under diluted conditions is the prechamber ignition (or turbulent jet ignition) which uses chemically active turbulent jets generated from combustion inside a prechamber to initiate, stabilize and accelerate combustion of the mixture inside the main chamber. The present work focusses on developing a RANS-based CFD approach to accurately reproduce in-cylinder phenomena in a stoichiometric NG prechamber-assisted heavy-duty engine without relying on complex combustion models that account for turbulence-chemistry interactions. This is necessary because reactive prechamber jets at high EGR dilution tend to extinguish while emerging into the main chamber, which is followed by a phase of re-ignition — a phenomenon that conventional G-equation or well-stirred reactor combustion models cannot reproduce. With addition of a damping multiplier to the well-stirred reactor model, the predictions are seen to show good agreement with experimental pressure evolution and combustion images acquired from a single cylinder Cummins N-14 optical diesel engine retrofitted with a prechamber ignition system. Model predictions of local heat release in the flame and temperature evolution inside the flame are used to investigate combustion dynamics in the prechamber and the main chamber. It is seen that the well-stirred reactor model with the inclusion of damping is able to reproduce the temporary reduction in heat release within the flame, which can be considered equivalent to quenching of jets, and the subsequent re-ignition of the flame inside the main chamber. The delay between quenching and re-ignition depends on the amount of dilution, as explained by an illustration of flame evolution in a Borghi diagram.

Prechamber ignition↗

Analysis of Risks to Oxygen Systems from Particulate and Fiber Contaminants and Derivation of Cleanliness Requirements

It has been well documented in the literature that contamination within oxygen systems can create significant fire hazards. Cleanliness limits for nonvolatile residues, ranging from 10 to 500 mg/sq m, have been established for various industries and types of oxygen systems to reduce the risk of ignition of flammable organic films. Particulate cleanliness limits used for oxygen systems vary considerably. Maximum allowed particle size, quantity limits, and allocations for fibers or metallic particles are all variables seen in aerospace cleanliness limits. Particles are known to have the potential to ignite within oxygen systems and must be limited to prevent fires. Particulate contamination may also pose risks to the performance of oxygen systems that are unrelated to ignition hazards. An extensive literature search was performed to better understand the relative importance of particle ignition mechanisms versus other deleterious effects of particles on oxygen systems and to identify rationale for derivation of particulate cleanliness limits for specific systems. The identified risks of different types and sizes of particles and fibers were analyzed. This paper summarizes the risks identified and rationale that may be used to derive particulate cleanliness limits for specific oxygen systems.

Lowrey, Nikki M.↗

Analysis of Risks to Oxygen Systems from Particulate and Fiber Contaminants and Derivation of Cleanliness Requirements

It has been well documented in the literature that contamination within oxygen systems can create significant fire hazards. Cleanliness limits for nonvolatile residues, ranging from 10 to 500 milligrams per square meter, have been established for various industries and types of oxygen systems to reduce the risk of ignition of flammable organic films. Particulate cleanliness limits used for oxygen systems, however, vary considerably, notably within the aerospace industry. Maximum allowed particle size, quantity limits, and allocations for fibers or metallic particles are all variables seen in aerospace cleanliness limits. Particles are known to have the potential to ignite within oxygen systems and must be limited to prevent fires. Particulate contamination may also pose risks to the performance of oxygen systems that are unrelated to ignition hazards. An extensive literature search was performed to better understand the relative importance of particle ignition mechanisms versus other deleterious effects of particles on oxygen systems and to identify rationale for derivation of particulate cleanliness limits for specific systems. The identified risks of different types and sizes of particles and fibers were analyzed. This paper summarizes the risks identified and rationale that may be used to derive particulate cleanliness limits for specific oxygen systems.

Lowrey, Nikki M.↗

NASA Engineering and Safety Center Technical Bulletin No. 20-06: Material Compatibility Assessment of Spacecraft Oxidizer Systems

Recently designed oxidizer systems used in spacecraft propulsion are pushing the limits of materials and operating conditions. As a result, nitrogen tetroxide (NTO) oxidizer systems are exhibiting failures driven by ignition mechanisms similar to oxygen systems. Oxidizer systems (e.g., O 2 , N 2 O 4 , N 2 O H 2 O 2 ) have generally been designed and operated within industry experience for material corrosion concerns without a complete understanding or regard for the concerns regarding potential material ignition and burning. To compound the problem, the effects of varying parameters on ignition and the kindling chain have not been studied, and there is a very limited amount of published data to help with the understanding. NASA-sponsored testing is actively researching ignition mechanisms, determining thresholds, and defining operating envelopes to inform the aerospace community.

NESC↗

Test methods for determining the suitability of metal alloys for use in oxygen-enriched environments

Materials are more flammable in oxygen rich environments than in air. When the structural elements of a system containing oxygen ignite and burn, the results are often catastrophic, causing loss of equipment and perhaps even human lives. Therefore, selection of the proper metallic and non-metallic materials for use in oxygen systems is extremely important. While test methods for the selection of non-metallic materials have been available for years, test methods for the selection of alloys have not been available until recently. Presented here are several test methods that were developed recently at NASA's White Sands Test Facility (WSTF) to study the ignition and combustion of alloys, including the supersonic and subsonic speed particle impact tests, the frictional heating and coefficient of friction tests, and the promoted combustion test. These test methods are available for commercial use.

Stoltzfus, Joel M.↗