Search NASA⌕ Search

SEARCH · Search NASA

Results for “Importance Sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Small Scale Field Test Demonstrating CO 2 Sequestration In Arbuckle Saline Aquifer And By CO 2 -Eor At Wellington Field, Sumner County, Kansas

The objectives of this project are to understand the processes that occur when a maximum of 70,000 metric tonnes of CO 2 are injected into two different formations to evaluate the response in different lithofacies and depositional environments. The evaluation will be accomplished through the use of both in situ and indirect MVA (monitoring, verification, and accounting) technologies. The project will optimize for carbon storage accounting for 99% of the CO 2 using lab and field testing and comprehensive characterization and modeling techniques. Site characterization and CO 2 injection should demonstrate state-of-the-art MVA tools and techniques to monitor and visualize the injected CO 2 plume and to refine geomodels developed using nearly continuous core, exhaustive wireline logs, and well tests and a multi-component 3-D seismic survey. Reservoir simulation studies will map the injected CO 2 plume and estimate tonnage of CO 2 stored in solution, as residual gas, and by mineralization and integrate MVA results and reservoir models shall be used to evaluate CO 2 leakage. A rapid-response mitigation plan was developed to minimize CO 2 leakage and provide a comprehensive risk management strategy. The CO 2 was intended to be supplied from a reliable facility and have an adequate delivery and quality of CO 2 . However, several unforeseen circumstances complicated this plan: (1) the initially negotiated CO 2 supply facility went offline and contracts associated with CO 2 supply had to be renegotiated, (2) a UIC Class VI permit proved to be difficult to obtain due to the experimental nature of the project. Both subjects are detailed in separate deliverables attached to this report. The CO 2 enhanced oil recovery (EOR) and geologic storage in Mississippian carbonate reservoir was sucessully deployed. Approximately 20,000 metric tons of CO 2 was injected in the upper part of the Mississippian reservoir to verify CO 2 EOR viability in carbonate reservoirs and evaluate a potential of transitioning to geologic CO 2 storage through EOR. A total of 1,101 truckloads, 19,803 metric tons—an average of 120 tonnes per day—were delivered over the course of injection that lasted from January 9 to June 21, 2016. After cessation of CO 2 injection, the KGS 2-32 well was converted to water injector and continues to operate. CO 2 EOR progression in the field was monitored weekly with fluid level, temperature, and production recording and formation fluid composition sampling. It is important to note that normally, CO 2 EOR pilots are less efficient than commercial operations due to lack of directional and precise well control, lack of surface facilities for CO 2 recycling, and other factors. As a result of this pilot CO 2 injection, the observed incremental average oil production increase was ~68% with only ~18% of injected CO 2 produced back. Decline curve analysis forecasts of additional cumulative oil produced were 32.44M STB to the end of 2027. Wellington Mississippian pilot efficiency by the end of forecast calculations is 11 MCF per barrel of produced oil. Using 32M STB oil production and $1,964,063 cost of CO 2 , CO 2 EOR cost per barrel of oil production is ~$60. Simple but robust monitoring technologies proved to be very efficient in detecting and locating CO 2 . High CO 2 reservoir retentions with low yields within an actively producing field could help to estimate real-world risks of CO 2 geological storage for future projects. The Wellington Field CO 2 EOR was executed in a controlled environment with high efficiency. This case study proves that CO 2 EOR could be successfully applied in Kansas carbonate reservoirs if CO 2 sources and associated infrastructure are available. Recent developments in unconventional resources development in Mid-Continent USA and associated large volume disposal of backflow water and the resulting seismic activity have brought more focus and attention to the Arbuckle Group in southern Kansas. Despite the commercial interest, limited essential information about reservoir properties and structural elements has impeded the management and regulation of disposal, an issue brought to the forefront by recent seismicity in and near areas of large volumes and rates of brine disposal. The Kansas Geological Survey (KGS) collected, compiled, and analyzed available data, including well logs, core data, step rate tests, drill stem tests, 2-D and 3-D seismic data, water level measurements, and others types of data. Several exploratory wells were drilled and core was collected and modern suites of logs were analyzed. Reservoir properties were populated into several site-specific geological models. The geological models illustrate the highly heterogeneous nature of the Arbuckle Group. Vertical and horizontal variability results in several distinct hydro-stratigraphic units that are the result of both depositional and diagenetic processes. During the course of this project, it has been demonstrated that advanced seismic interpretation methods can be used successfully for characterization of the Mississippian reservoir and Arbuckle saline aquifer. Analysis of post-stack 3-D seismic data at the Mississippian reservoir showed the response of a gradational velocity transition. Pre-stack gather analysis showed that porosity zones of the Mississippian and Arbuckle reservoirs exhibit characteristic amplitude versus offset (AVO) response. Simultaneous AVO inversion estimated P- and S-impedances. The 3-D survey gather azimuthal anisotropy analysis (AVAZ) provided information about the fault and fracture network and showed good agreement to the regional stress field and well data. Mississippian reservoir porosity and fracture predictions agreed well with the observed mobility of injected CO 2 in KGS well 2-32. Fluid substitution modeling predicted acoustic impedance reduction in the Mississippian carbonate reservoir introduced by the presence of CO 2 . Seismicity in the United States midcontinent has increased by orders of magnitude over the past decade. Spatiotemporal correlations of seismicity to wastewater injection operations have suggested that injection-related pore fluid pressure increases are inducing the earthquakes. In this investigation, we examine earthquake occurrence in southern Kansas and northern Oklahoma and its relation to the change in pore pressure. The main source of data comes from the Wellington Array in the Wellington oil field, in Sumner County, Kansas, which has monitored for earthquakes in central Sumner County, Kansas, since early 2015. The seismometer array was established to monitor CO 2 injection operations at Wellington Field. Although no seismicity was detected in association with the spring 2016 Mississippian CO 2 injection, the array has recorded more than 2,500 earthquakes in the region and is providing valuable understanding to induced seismicity. A catalog of earthquakes was built from this data and was analyzed for spatial and temporal changes, stress information, and anisotropy information. The region of seismic concern has been shown to be expanding through use of the Wellington earthquake catalog, which has revealed a northward progression of earthquake activity reaching the metropolitan area of Wichita. The stress orientation was also calculated from this earthquake catalog through focal mechanism inversion. The calculated stress orientation was confirmed through comparison to other stress measurements from well data and previous earthquake studies in the region. With this knowledge of the stress orientation, the anisotropy in the basement could be understood. This allowed for the anisotropy measurements to be correlated to pore pressure increases. The increase in pore pressure was monitored through time-lapse shear-wave anisotropy analysis. Since the onset of the observation period in 2010, the orientation of the fast shear wave has rotated 90°, indicating a change associated with critical pore pressure build up. The time delay between fast and slow shear wave arrivals has increased, indicating a corresponding increase in anisotropy induced by pore pressure rise. In-situ near-basement fluid pressure measurements corroborate the continuous pore pressure increase revealed by the shear-wave anisotropy analysis over the earthquake monitoring period. This research is the first to identify a change in pore fluid pressure in the basement using seismological data and it was recently published in the AAAS journal Science Advances (Nolte et al., 2017). The shear-wave splitting analysis is a novel application of the technique, which can be used in other regions to identify an increase in pore pressure. This increasing pore fluid pressure has become more regionally extensive as earthquakes are occurring in southern Kansas, where they previously were absent. These monitoring techniques and analyses provide new insight into mitigating induced seismicity’s impact on society.

02 PETROLEUM↗

Ultra-high speed imaging and DIC for explosive system observation.

Digital image correlation (DIC) and the tremendous advances in optical imaging are beginning to revolutionize explosive and high-strain rate measurements. This paper presents results obtained from metallic hemispheres expanded at detonation velocities. Important aspects of sample preparation and lighting of the image will be presented that are key considerations in obtaining images for DIC with frame rates at 1-million frames/second. Quantitative measurements of the case strain rate, expansion velocity and deformation will be presented. Furthermore, preliminary estimations of the measurement uncertainty will be discussed with notes on how image noise and contrast effect the measurement of shape and displacement. The data are then compared with analytical representations of the experiment.

99 GENERAL AND MISCELLANEOUS↗

The radiolysis of CMPO: effects of acid, metal complexation and alpha vs. gamma radiation

Abstract The group actinide/lanthanide complexing agent octylphenylcarbamoylmethyl phosphine oxide (CMPO) has been examined for its radiation stability by measuring the kinetics of its reactions with free radicals in both the aqueous and organic phases for the free and metal-complexed ligand, identifying its degradation products for both alpha and gamma irradiation, measuring the effects on solvent extraction performance, and measuring the G-values for its degradation under various conditions. This includes the G-values for CMPO in the absence of, and in contact with the acidic aqueous phase, where it is shown that the acidic aqueous phase provides radio-protection for this ligand. It was found that both solvent and metal complexation affect the kinetics of the reaction of the •NO3 radical, a product of HNO3 radiolysis, with CMPO. For example, CMPO complexed with lanthanides has a rate constant for this reaction an order of magnitude higher than for the free ligand, and the reaction for the free ligand in the organic phase is about three times faster than in the aqueous phase. In steady state radiolysis kinetics it was determined that HNO3, although not NO3- anion, provides radio-protection to CMPO, with the G-value for its degradation decreasing with increasing acidity, until it was almost completely suppressed by irradiation in contact with 5 M HNO3. The same degradation products were produced by irradiation with alpha and gamma-sources, except that the relative abundances of these products varied. For example, the product of C-C bond scission was produced only in low amounts for gamma-radiolysis, but it was an important product for samples irradiated with a He ion beam. These results are compared to the new data appearing in the literature on DGA radiolysis, since CMPO and the DGAs both contain the amide functional group.

CMPO↗

Field Test to Evaluate Deep Borehole Disposal.

The U.S. Department of Energy (DOE) has embarked on the Deep Borehole Field Test (DBFT), which will investigate whether conditions suitable for disposal of radioactive waste can be found at a depth of up to 5 km in the earth’s crust. As planned, the DBFT will demonstrate drilling and construction of two boreholes, one for initial scientific characterization, and the other at a larger diameter such as could be appropriate for waste disposal (the DBFT will not involve radioactive waste). A wide range of geoscience activities is planned for the Characterization Borehole, and an engineering demonstration of test package emplacement and retrieval is planned for the larger Field Test Borehole. Characterization activities will focus on measurements and samples that are important for evaluating the long-term isolation capability of the Deep Borehole Disposal (DBD) concept. Engineering demonstration activities will focus on providing data to evaluate the concept’s operational safety and practicality. Procurement of a scientifically acceptable DBFT site and a site management contractor is now underway. The concept of deep borehole disposal (DBD) for radioactive wastes is not new. It was considered by the National Academy of Science (NAS 1957) for liquid waste, studied in the 1980’s in the U.S. (Woodward–Clyde 1983), and has been evaluated by European waste disposal R&D programs in the past few decades (for example, Grundfelt and Crawford 2014; Grundfelt 2010). Deep injection of wastewater including hazardous wastes is ongoing in the U.S. and regulated by the Environmental Protection Agency (EPA 2001). The DBFT is being conducted with a view to use the DBD concept for future disposal of smaller-quantity, DOE-managed wastes from nuclear weapons production (i.e., Cs/Sr capsules and granular solid wastes). However, the concept may also have broader applicability for nations that have a need to dispose of limited amounts of spent fuel from nuclear power reactors. For such nations the cost for disposing of volumetrically limited waste streams could be lower than mined geologic repositories.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The Cost of (In-) Accurate Waste Characterization in the U.S. Nuclear Power Industry - 20066

Proper disposal of waste has never been a human priority. Our history is full of examples of throwing away things with minimal effort or thought to consequence. That is until disease or toxicity become apparent and we realize we need to change. Unfortunately, we almost never have all the information we need at the time we make decisions. In addition to the technical and scientific issues, profits and politics are also factors. Newton's third law also applies to politics and so for every policy (action) put in place, there will be (opposite reaction) forces in play to push back against it. These forces are seldom balanced and so the reaction to the discovery of harm is to over-correct and destroy the benefit to be had. This of course causes those who want the benefit, or profit from it, to work to undermine or repeal those measures put in place to eliminate the harm. The issue is exacerbated when the problem to be solved is highly technical and at the edge of our science so that the harm and benefit cannot be easily or accurately quantified. At these times, reason often goes out the window and our decision makers are influenced by either greed or fear as these emotions are much easier to stoke. Those of us in the middle, with the charge to 'do the right thing for the least cost', are therefore frequently constrained and forced into actions that are neither technically the right thing to do and not cost effective. The cost of radioactive waste disposal is based on the concentrations of various radioisotopes in the waste. Some of these isotopes are relatively easy to quantify and some are not. Most laboratory methods for quantification are limited in the amount of activity that can be present during the measurement process. Current nuclear plants were not designed with the idea that taking truly representative waste samples would be important. The limits used to define waste class and therefore cost are precisely defined but the methods for determining those concentrations are far less precise. Improving the accuracy of radioactivity concentrations in waste and having consistent and reasonable oversight can reduce waste costs through active management of the process. So what can we do about it? Science may provide an answer. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

PACKAGING AND TRANSPORTATION OF NEPTUNIUM OXIDE

The Savannah River Site's HB-Line Facility completed a campaign in which fifty (50) cans of neptunium oxide were produced and shipped to the Idaho National Laboratory in the 9975 shipping container. This shipping campaign involved the addition of neptunium oxide to the 9975 Safety Analysis Report for Packaging (SARP) as a new content and subsequently a Letter of Amendment to the SARP content table. This paper will address the proper steps which should be taken to add a new content table to a SARP. It will also address the importance of product sampling and understanding the material shipping requirements of a SARP.

42 ENGINEERING↗

Solving Complex Radioactive Decay Chains for Future Assessment and Cleanup Decisions - 17046

In support of U.S. Environmental Protection Agency's on-line calculators for risk and dose assessment, a decay chain tool was developed to address the need to understand how radionuclide activity changes with time as the activity measured in the past will be different from current and future levels. When a radionuclide decays, its activity decreases exponentially as a function of time transforming into a different atom - a decay product. The atoms keep transforming to new decay products until they reach a stable state and are no longer radioactive. The series of decay products created to reach this balance is called the decay chain. For radionuclide chains, the daughter products can have significant implications in dosimetry and remediation. Thus, risk assessors evaluating sites with radioactive contamination need to plan for future progeny ingrowth, in addition to sampled radionuclides. These are important considerations for risk quantification during the characterization and cleanup plans, particularly when sampling may have occurred years before the remediation cleanup work begins. If a radionuclide half-life and current activity are known, then hand-calculating the future activity is straightforward. However, calculating the ingrowth of progeny quickly becomes cumbersome for longer chains such as the Thorium-232 decay series. For the more complex chains where many daughters are formed, possibly with multiple branches, this calculation involves solving a complex set of simultaneous differential equations known as the Bateman Equation. The Decay Chain Activity Projection Tool calculates the activity of radionuclides and their progeny as a function of time. This tool currently uses a combination of Perl, JavaScript, Plot.ly, and jQuery to automatically construct the radionuclide decay chains, solve the resulting Bateman Equation, and provide the user with tabular solution output and plots. Additional software may be used as development advances. The risk assessor can then use the data for exposure assessment and cleanup decisions without further costly sampling. The benefits of providing this calculator are to prevent overestimation of risk due to decay of the parent isotope and to avoid underestimation of risk due to ingrowth of progeny more toxic than the parent. Graphs are provided to show the simultaneous decay rates and ingrowth, as well as tabular output at time-point T and all the decay half-life intervals. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SU-F-T-220: Validation of Hounsfield Unit-To-Stopping Power Ratio Calibration Used for Dose Calculation in Proton Radiotherapy

Purpose: To validate the stoichiometric calibration of the Hounsfield Unit (HU) to Stopping Power Ratio (SPR) calibration used to commission a commercial treatment planning system (TPS) for proton radiotherapy dose calculation. Methods and Materials: The water equivalent thickness (WET) of several individual pig tissues (lung, fat, muscle, liver, intestine, rib, femur), mixed tissue samples (muscle/rib, ice/femur, rib/air cavity/muscle), and an intact pig head were measured with a multi-layer ionization chamber (MLIC). A CT scan of each sample was obtained and imported into a commercial TPS. The WET calculated by the TPS for each tissue sample was compared to the measured WET value to determine the accuracy of the HU-to-SPR calibration curve used by the TPS to calculate dose. Results: The WET values calculated by the TPS showed good agreement (< 2.0%) with the measured values for bone and all soft tissues except fat (3.1% difference). For the mixed tissue samples and the intact pig head measurements, the difference in the TPS and measured WET values all agreed to within 3.5%. In addition, SPR values were calculated from the measured WET of each tissue, and compared to SPR values of reference tissues from ICRU 46 used to generate the HU-to-SPR calibration for the TPS. Conclusion: For clinical scenarios where the beam passes through multiple tissue types and its path is dominated by soft tissues, we believe using an uncertainty of 3.5% of the planned beam range is acceptable to account for uncertainties in the TPS WET determination.

60 APPLIED LIFE SCIENCES↗

Using low volume eDNA methods to sample pelagic marine animal assemblages

Environmental DNA (eDNA) is an increasingly useful method for detecting pelagic animals in the ocean but typically requires large water volumes to sample diverse assemblages. Ship-based pelagic sampling programs that could implement eDNA methods generally have restrictive water budgets. Studies that quantify how eDNA methods perform on low water volumes in the ocean are limited, especially in deep-sea habitats with low animal biomass and poorly described species assemblages. Using 12S rRNA and COI gene primers, we quantified assemblages comprised of micronekton, coastal forage fishes, and zooplankton from low volume eDNA seawater samples (n = 436, 380–1800 mL) collected at depths of 0–2200 m in the southern California Current. We compared diversity in eDNA samples to concurrently collected pelagic trawl samples (n = 27), detecting a higher diversity of vertebrate and invertebrate groups in the eDNA samples. Differences in assemblage composition could be explained by variability in size-selectivity among methods and DNA primer suitability across taxonomic groups. The number of reads and amplicon sequences variants (ASVs) did not vary substantially among shallow (<200 m) and deep samples (>600 m), but the proportion of invertebrate ASVs that could be assigned a species-level identification decreased with sampling depth. Using hierarchical clustering, we resolved horizontal and vertical variability in marine animal assemblages from samples characterized by a relatively low diversity of ecologically important species. Low volume eDNA samples will quantify greater taxonomic diversity as reference libraries, especially for deep-dwelling invertebrate species, continue to expand.

59 BASIC BIOLOGICAL SCIENCES↗

Real sample temperature: a critical issue in the experiments of nuclear resonant vibrational spectroscopy on biological samples

There are several practical and intertangled issues which make the experiments of nuclear resonant vibrational spectroscopy (NRVS) on biological samples difficult to perform. The sample temperature is one of the most important issues. In NRVS the real sample temperatures can be very different from the readings on the temperature sensors. In this study the following have been performed: (i) citing and analyzing various existing NRVS data to assess the real sample temperatures during the NRVS measurements and to understand their trends with the samples’ loading conditions; (ii) designing several NRVS measurements with (Et 4 N)[FeCl 4 ] to verify these trends; and (iii) proposing a new sampleloading procedure to achieve significantly lower real sample temperatures and to balance among the intertangled experimental issues in biological NRVS measurements.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

DO BARS DRIVE SPIRAL DENSITY WAVES?

We present deep near-infrared K{sub s} -band Anglo-Australian Telescope Infrared Imager and Spectrograph observations of a selected sample of nearby barred spiral galaxies, including some with the strongest known bars. The sample covers a range of Hubble types from SB0{sup -} to SBc. The goal is to determine if the torque strengths of the spirals correlate with those of the bars, which might be expected if the bars actually drive the spirals as has been predicted by theoretical studies. This issue has implications for interpreting bar and spiral fractions at high redshift. Analysis of previous samples suggested that such a correlation exists in the near-infrared, where effects of extinction and star formation are less important. However, the earlier samples had only a few excessively strong bars. Our new sample largely confirms our previous studies, but still any correlation is relatively weak. We find two galaxies, NGC 7513 and UGC 10862, where there is only a weak spiral in the presence of a very strong bar. We suggest that some spirals probably are driven by their bars at the same pattern speed, but that this may be only when the bar is growing or if there is abundant gas and dissipation.

79 ASTRONOMY AND ASTROPHYSICS↗

Current and future federal and state sampling guidance for per- and polyfluoroalkyl substances in environmental matrices

Per- and polyfluoroalkyl substances (PFAS) are a class of emerging contaminants composed of an estimated 5000 to 10,000 human-made, fluorinated, organic chemicals. Due to the complexity of PFAS, the need for multiple environmental matrix considerations and the absence of a promulgated federal standard for environmental sampling and analysis, U.S. states have begun developing health-based regulatory and/or guidance values for a limited number of PFAS in environmental matrices. As there is a growing body of science to inform PFAS sampling guidance standard development, it is important to understand which U.S. states are implementing sampling guidelines and how they plan to handle emerging PFAS. This critical review discusses the current and impending federal and state sampling guidelines for PFAS in environmental matrices, the data gaps surrounding PFAS sampling guidance in U.S. states, and the future impacts of impending guidance documents and regulations. Ten federal guidance documents are available for PFAS sampling guidance and analysis. The maximum number of PFAS covered in these guidance documents is 25 analytes spanning across 8 unique media. While the EPA has developed several different sampling and analytical guidelines for PFAS, there is no formal regulation of PFAS or requirements of states to enforce these guidelines. Consequently, only 31 states have informally adopted sampling guidelines, while the other 19 states have no guidance documentation in place for PFAS. The introduction of new PFAS sampling guidelines by the EPA, as well as updated analytical guidelines that target more PFAS or total organofluoride, is expected to continuously shift the landscape of federal and state guidance for PFAS sampling moving forward.

54 ENVIRONMENTAL SCIENCES↗

Performance of a Silicon-Drift Detector in 200kV TEM Environments

Silicon-drift detectors for energy-dispersive spectroscopy have gained increasing acceptance in the field principally because of their outstanding capabilities for high count-rate performance coupled with excellent resolution [1,2]. Improvements in design in the last few years have overcome some early disadvantages of the SDD in comparison to Si(Li) detectors, which have dominated the field for nearly 4 decades. Amongst these are detection efficiency in the low-energy regime, and a dropoff in detection efficiency at higher energies above 10keV. The former disadvantage has been largely overcome by generational design improvements to minimize the effective dead layer at the entrance window, so that present detectors provide better performance in the low-energy regime than Si(Li) detectors. In the latter case, higher energy peak detection performance has been improved by increasing the thickness of the detector. This is important primarily for the use of the SDD in a TEM environment, where very high count rates are not encountered due to the thin sample geometry. Also of importance for incorporation of an SDD into a TEM column is the lack of need for liquid nitrogen, since the SDD is chilled by a thermoelectric cooler. This is an advantage for SEM and microprobe operation also, but high-resolution TEMs (particularly aberration-corrected instruments) are more sensitive to vibration than SEMs or microprobes, so the much reduced form factor of an air-cooled SDD relative to a Si(Li) detector with a large LN2 dewar is desirable for use on the TEM. We have recently tested two Bruker C

200kV TEM↗

Sample preparation with sucrose cryoprotection dramatically alters Zn distribution in the rodent hippocampus, as revealed by elemental mapping

Transition metal ions (Fe, Mn, Cu, Zn) are essential for healthy brain function, but altered concentration, distribution, or chemical form of the metal ions has been implicated in numerous brain pathologies. Currently, it is not possible to image the cellular or sub-cellular distribution of metal ions in vivo and therefore, studying brain-metal homeostasis largely relies on ex vivo in situ elemental mapping. Sample preparation methods that accurately preserve the in vivo elemental distribution are essential if one wishes to translate the knowledge of elemental distributions measured ex vivo toward increased understanding of chemical and physiological pathways of brain disease. Furthermore, the choice of sample preparation is particularly important for metal ions that exist in a labile or mobile form, for which the in vivo distribution could be easily distorted by inappropriate sample preparation. One of the most widely studied brain structures, the hippocampus, contains a large pool of labile and mobile Zn. Herein, we describe how sucrose cryoprotection, the gold standard method of preparing tissues for immuno-histochemistry or immuno-fluorescence, which is also often used as a sample preparation method for elemental mapping studies, drastically alters hippocampal Zn distribution. Based on the results of this study, in combination with a comparison against the strong body of published literature that has used either rapid plunge freezing of brain tissue, or sucrose cryo-protection, we strongly urge investigators in the future to cease using sucrose cryoprotection as a method of sample preparation for elemental mapping, especially if Zn is an analyte of interest.

59 BASIC BIOLOGICAL SCIENCES↗

Enhanced Iron Solubility at Low pH in Global Aerosols

The composition and oxidation state of aerosol iron were examined using synchrotron-based iron near-edge X-ray absorption spectroscopy. By combining synchrotron-based techniques with water leachate analysis, impacts of oxidation state and mineralogy on aerosol iron solubility were assessed for samples taken from multiple locations in the Southern and the Atlantic Oceans; and also from Noida (India), Bermuda, and the Eastern Mediterranean (Crete). These sampling locations capture iron-containing aerosols from different source regions with varying marine, mineral dust, and anthropogenic influences. Across all locations, pH had the dominating influence on aerosol iron solubility. When aerosol samples were approximately neutral pH, iron solubility was on average 3.4%; when samples were below pH 4, the iron solubility increased to 35%. This observed aerosol iron solubility profile is consistent with thermodynamic predictions for the solubility of Fe(III) oxides, the major iron containing phase in the aerosol samples. Source regions and transport paths were also important factors affecting iron solubility, as samples originating from or passing over populated regions tended to contain more soluble iron. Although the acidity appears to affect aerosol iron solubility globally, a direct relationship for all samples is further confounded by factors such as anthropogenic influence, aerosol buffer capacity, mineralogy and physical processes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Diagnosing the plasma nonuniformity in an iron opacity experiment by spatially resolved Al 1s-2p absorption spectroscopy

Generating a well-characterized hot-dense sample is of great importance to high quality opacity measurements. In this paper, we report on an experimental investigation of the plasma nonuniformity in a radiatively heated iron opacity sample by spatially resolved Al 1s-2p absorption spectroscopy. The iron sample was tamped by plastic at both sides and was heated by thermal x-ray radiation generated in a gold Hohlraum, and an Al layer attached to it was used as a tracer for temperature diagnosis. Spatially resolved 1s-2p transition absorption spectra of the Al tracer were measured by the technique of point-projection-spectroscopy, and temperatures in the sample were obtained by comparing the measured spectra with detailed-term-accounting model calculations, with the density of the sample deduced using a combination of side-on radiography and radiative hydrodynamic simulation. The results showed the existence of axial temperature nonuniformity in the sample, and these temperature variations have been used to explain the shift of iron 2p-3d transition absorption feature along the axial direction of the Hohlraum used to heat the sample successfully.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Bayesian Approach for Quantifying Data Scarcity when Modeling Human Behavior via Inverse Reinforcement Learning

Computational models that formalize complex human behaviors enable study and understanding of such behaviors. However, collecting behavior data required to estimate the parameters of such models is often tedious and resource intensive. Thus, estimating dataset size as part of data collection planning (also known as Sample Size Determination) is important to reduce the time and effort of behavior data collection while maintaining an accurate estimate of model parameters. In this paper, we present a sample size determination method based on Uncertainty Quantification (UQ) for a specific Inverse Reinforcement Learning (IRL) model of human behavior, in two cases: 1) pre-hoc experiment design—conducted in the planning stage before any data is collected, to guide the estimation of how many samples to collect; and 2) post-hoc dataset analysis—performed after data is collected, to decide if the existing dataset has sufficient samples and whether more data is needed. Here, we validate our approach in experiments with a realistic model of behaviors of people with Multiple Sclerosis (MS) and illustrate how to pick a reasonable sample size target. Our work enables model designers to perform a deeper, principled investigation of effects of dataset size on IRL.

97 MATHEMATICS AND COMPUTING↗

Rapid method for the determination of 226Ra in hydraulic fracturing wastewater samples

A new method that rapidly preconcentrates and measures 226 Ra from hydraulic fracturing wastewater samples was developed in the Savannah River Environmental Laboratory. The method improves the quality of 226 Ra measurements using gamma spectrometry by providing up to 100x preconcentration of 226 Ra from this difficult sample matrix, which contains very high levels of calcium, barium, strontium, magnesium and sodium. The high chemical yield, typically 80-90%, facilitates a low detection limit, important for lower level samples, and indicates method ruggedness. Ba-133 tracer is used to determine chemical yield and correct for geometry-related counting issues. The 226 Ra sample preparation takes < 2 hours.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗