Search NASA⌕ Search

SEARCH · Search NASA

Results for “Induction heating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

A survey of thermocouple anomalies: mechanisms, interpretation, and mitigation

Thermocouples (TCs) are a critical diagnostic sensor for high enthalpy environments including thermal protection systems (TPS) for atmospheric re-entry, hypersonic wind tunnels, and arc jet test facilities. They are used for both evaluating facility environmental conditions (enthalpy, heat flux) as well as for measuring in-situ material thermal response under test conditions (thermal conductivity, heat capacity, B’, etc.). Consequently, accurate TC measurements are fundamental for both material and facility verification and validation (V&V). However, a number of TC anomalies have been observed in both ground tests and flight instrumentation. These anomalies are caused via various coupling mechanisms: electrostatic gradients, temperature-dependent electrical shorts, radio pickup, magnetic induction, and pressure-dependent leaks. All of these mechanisms can, if unaddressed, result in obviously compromised results or worse, non-physical measurements which appear reasonable. This work will survey known anomaly mechanisms and discuss ongoing efforts to quantify and mitigate anomaly mechanisms including anomaly modeling, diagnostics, and new TC designs/development.

thermocouple anomalies↗

A Survey of Thermocouple Anomalies: Mechanisms, Interpretation, and Mitigation

Thermocouples (TCs) are a critical diagnostic sensor for high enthalpy environments including thermal protection systems (TPS) for atmospheric re-entry, hypersonic wind tunnels, and arc jet test facilities. They are used for both evaluating facility environmental conditions (enthalpy, heat flux) as well as for measuring in-situ material thermal response under test conditions (thermal conductivity, heat capacity, B’, etc.). Consequently, accurate TC measurements are fundamental for both material and facility verification and validation (V&V). However, a number of TC anomalies have been observed in both ground tests and flight instrumentation. These anomalies are caused via various coupling mechanisms: electrostatic gradients, temperature-dependent electrical shorts, radio pickup, magnetic induction, and pressure-dependent leaks. All of these mechanisms can, if unaddressed, result in obviously compromised results or worse, non-physical measurements which appear reasonable. This work will survey known anomaly mechanisms and discuss ongoing efforts to quantify and mitigate anomaly mechanisms including anomaly modeling, diagnostics, and new TC designs/development.

Thermocouple Anomalies↗

Theory of an Electromagnetic Mass Accelerator for Achieving Hypervelocities

It is shown that for any electromagnetic accelerator which employs an electromagnetic force for driving the projectile and uses the projectile as the heat sink for the energy dissipated in it by ohmic heating, the maximum velocity attainable without melting is a function of the mass of the projectile. Therefore, for hypervelocities a large projectile mass is required and thus a power supply of very large capacity is necessary. It is shown that the only means for reducing the power requirement is maximizing the gradient of the mutual inductance. In the scheme of the sliding-coil accelerator investigated herein, the gradient of the mutual inductance is continuously maintained at a high value. It is also shown that for minimum length of the accelerator, the current must be kept constant despite the rise in induced voltage during acceleration. The use of a capacitor bank as an energy source with the condition that the current be kept constant is investigated. Experiments at low velocities are described.

Thom, Karlheinz↗

Studies of Thermophysical Properties of Metals and Semiconductors by Containerless Processing Under Microgravity

Electromagnetic levitation under microgravity provides unique opportunities for the investigation of liquid metals, alloys and semiconductors, both above and below their melting temperatures, with minimized disturbances of the sample under investigation. The opportunity to perform such experiments will soon be available on the ISS with the EML payload which is currently being integrated. With its high-performance diagnostics systems EML allows to measure various physical properties such as heat capacity, enthalpy of fusion, viscosity, surface tension, thermal expansion coefficient, and electrical conductivity. In studies of nucleation and solidification phenomena the nucleation kinetics, phase selection, and solidification velocity can be determined. Advanced measurement capabilities currently being studied include the measurement and control of the residual oxygen content of the process atmosphere and a complementary inductive technique to measure thermophysical properties.

Seidel, A.↗

Design and Engineering of LUPIN: A Test-Bed Radiofrequency Ion Source for Enhanced Neutral Beam Injection on DIII-D

The Large, Uniform Plasma for Ionizing Neutrals (LUPIN) is an RF inductively coupled plasma (ICP) chamber for demonstrating plasma performance of an RF ICP positive ion source upgrade for the DIII-D Neutral Beam Injection (NBI) system. LUPIN will be used to investigate ion source physics, including neutral gas dynamics, plasma density uniformity, interactions with Faraday shields, and power coupling to novel RF antenna designs. LUPIN has an RF generator capable of delivering 20 kW of power at 2 MHz, which is coupled into a cylindrical quartz vessel measuring 20 cm in length and 10 cm in radius. This configuration matches the power density requirements for a full-scale ion source. Target hydrogen and deuterium plasma densities exceeding 10 18 m -3 would relate to extracted ion current densities of 2100 A/m 2 for 10 s. Vacuum conductance and gas flow calculations predict a maximum achievable neutral gas flow rate of 1675 Pa·L/s at 5 Pa of He, which mimics the gas flow of the DIII-D NBI system. Designs have been developed for an internal Faraday shield to mitigate heat flux and ion sputtering on the dielectric vessel. Thermomechanical finite element simulations demonstrated the Faraday shield design to be capable of withstanding anticipated heat loads from worst-case operation scenarios. Results of upcoming experimental investigations on LUPIN will guide the design of a full-scale prototype for DIII-D integration.

Faraday shield↗

Direct simulation with vibration-dissociation coupling

The majority of implementations of the Direct Simulation Monte Carlo (DSMC) method of Bird do not account for vibration-dissociation coupling. Haas and Boyd have proposed the vibrationally-favored dissociation model to accomplish this task. This model requires measurements of induction distance to determine model constants. A more general expression has been derived that does not require any experimental input. The model is used to calculate one-dimensional shock waves in nitrogen and the flow past a lunar transfer vehicle (LTV). For the conditions considered in the simulation, the influence of vibration-dissociation coupling on heat transfer in the stagnation region of the LTV can be significant.

Hash, David B.↗

Modifications and testing of a 4-95 Stirling engine for solar applications

The modifications and testing of a standard Stirling engine, required for connection to a 25 kW induction alternator, for use with a solar thermal parabolic dish electric module is described. Power was absorbed by a GE induction alternator connected to the utility grid. Also included are the results from recent testing of another solar engine at the DOE-Georgia Tech solar site. It was done in parallel with the testing at Edwards for the purpose of comparing performance of two solar-only receivers, which were based on the standard 4-95 involute heat exchanger.

Nelving, H. G.↗

Nylon Sleeve for Cavity Amplifier Holds Tuning Despite Heat

The problem: Detuning of cavity amplifiers with change in temperature. This results in deterioration of the performance of the amplifier at its design frequency. In cavity amplifiers and filters it is desirable that constant performance be maintained regardless of thermal changes. These changes often cause an "off resonance shift" in a cavity filter and a deterioration of performance in a cavity amplifier. The solution: Mount the tuning probe in a nylon sleeve. Thermal expansion and contraction of the nylon nullifies unwanted capacitive and inductive changes in the resonant elements.

Derr, Lloyd↗

High-Enthalpy Testing to Validate Simulation of an Aerosol Capture Probe

AERACEPT (Aerosol Rapid Analysis Combined Entry Probe/sonde Technology) is a developing technology enabling in-situ aerosol particle sampling and analysis in a small spacecraft mission envelope. It integrates a passive aerosol sample collection system into a probe’s thermal protection system (TPS) to remove the need for heat shield separation and active descent control (parachutes, gliders, etc.). AERACEPT is being validated against the requirements of the Nephele mission concept, which targets the middle and lower Venus cloud layers. The proposed technology employs 3D Carbon-Carbon (3D-CC) at the probe’s nose to withstand the extreme environments encountered in a Venus entry without producing pyrolysis gases that would contaminate the mission sample collection. Any shape change of this 3D-CC sample inlet will affect airflow through the sampling system, thereby impacting aerosol sample collection bias and efficiency. Accurate prediction of the nose’s material response during entry is there-fore of fundamental importance to the development and practical use of this technology. As a result, the AERACEPT project is planning a test campaign in the newly built PlasmatronX facility with a novel “Open Iso-Q” test article to validate state-of-the-art material response tools for a simulated Venus entry. The PlasmatronX is a 350 kW inductively-coupled plasma facility developed and run by the Center for Hypersonics and Entry Systems Studies at the University of Illinois at Urbana-Champaign. The facility can support ground testing for a variety of planetary destinations by simulating entry conditions in Nitrogen, Air, and Carbon Dioxide. To best simulate the Venus atmosphere and match flight-like recession, the planned AERACEPT test campaign will use Carbon Dioxide as its test gas. AERACEPT has designed two test articles for this campaign: 1) a standard test article whose curved surface approximates a constant applied heat flux (“Closed Iso-Q” model) and 2) a novel inlet test article with a through-hole at the stagnation point (“Open Iso-Q” model). Both article types consist of a 3D-CC sample bonded to a graphite fixture. All articles will be laser scanned before and after testing to estimate shape change and recession, and the “Closed Iso-Q” articles will be instrumented with thermocouples to provide temperature histories. The test article temperatures and inlet shape change will be compared against simulations run with the Porous material Analysis Toolbox based on OpenFOAM (PATO) to validate the AERACEPT 3D-CC material response model. Due to the high thermal conductivity of 3D-CC, multidimensional effects have a large influence on the test article temperature and the standard 1-D material response tools are not sufficient for test planning. The test campaign features (e.g. article design, run duration, heat fluxes) are therefore informed by a series of 3-D simulations using state-of-the-art material response tools such as PATO. The test campaign is scheduled for spring of 2024. Expected results include 1) Key drivers of selected test conditions (e.g. matching mission flight atmosphere & recession), 2) Simulation results that informed test article design, 3) Acquired test data such as recession measurements, temperature histories, and photos, and 4) Comparisons between test results and simulation predictions.

AERACEPT↗

High-Enthalpy Testing to Validate Simulation of an Aerosol Capture Probe

AERACEPT (Aerosol Rapid Analysis Combined Entry Probe/sonde Technology) is a developing technology enabling in-situ aerosol particle sampling and analysis in a small spacecraft mission envelope. It integrates a passive aerosol sample collection system into a probe’s thermal protection system (TPS) to remove the need for heat shield separation and active descent control (parachutes, gliders, etc.). AERACEPT is being validated against the requirements of the Nephele mission concept, which targets the middle and lower Venus cloud layers. The proposed technology employs 3D Carbon-Carbon (3D-CC) at the probe’s nose to withstand the extreme environments encountered in a Venus entry without producing pyrolysis gases that would contaminate the mission sample collection. Any shape change of this 3D-CC sample inlet will affect airflow through the sampling system, thereby impacting aerosol sample collection bias and efficiency. Accurate prediction of the nose’s material response during entry is there-fore of fundamental importance to the development and practical use of this technology. As a result, the AERACEPT project is planning a test campaign in the newly built PlasmatronX facility with a novel “Open Iso-Q” test article to validate state-of-the-art material response tools for a simulated Venus entry. The PlasmatronX is a 350 kW inductively-coupled plasma facility developed and run by the Center for Hypersonics and Entry Systems Studies at the University of Illinois at Urbana-Champaign. The facility can support ground testing for a variety of planetary destinations by simulating entry conditions in Nitrogen, Air, and Carbon Dioxide. To best simulate the Venus atmosphere and match flight-like recession, the planned AERACEPT test campaign will use Carbon Dioxide as its test gas. AERACEPT has designed two test articles for this campaign: 1) a standard test article whose curved surface approximates a constant applied heat flux (“Closed Iso-Q” model) and 2) a novel inlet test article with a through-hole at the stagnation point (“Open Iso-Q” model). Both article types consist of a 3D-CC sample bonded to a graphite fixture. All articles will be laser scanned before and after testing to estimate shape change and recession, and the “Closed Iso-Q” articles will be instrumented with thermocouples to provide temperature histories. The test article temperatures and inlet shape change will be compared against simulations run with the Porous material Analysis Toolbox based on OpenFOAM (PATO) to validate the AERACEPT 3D-CC material response model. Due to the high thermal conductivity of 3D-CC, multidimensional effects have a large influence on the test article temperature and the standard 1-D material response tools are not sufficient for test planning. The test campaign features (e.g. article design, run duration, heat fluxes) are therefore informed by a series of 3-D simulations using state-of-the-art material response tools such as PATO. The test campaign is scheduled for spring of 2024. Expected results include 1) Key drivers of selected test conditions (e.g. matching mission flight atmosphere & recession), 2) Simulation results that informed test article design, 3) Acquired test data such as recession measurements, temperature histories, and photos, and 4) Comparisons between test results and simulation predictions.

AERACEPT↗

WEST L-mode record long pulses guided by predictions using Integrated Modeling

A new record was set on the WEST Tokamak, designed to operate long duration plasmas in a tungsten (W) environment, with an injected energy of 1.15 GJ and a plasma duration 364s. Scenario development was supported by integrated modeling using the High Fidelity Plasma Simulator (HFPS), the European IMAS-coupled version of JETTO/JINTRAC, which integrates physics-driven modules into a unified framework. In particular, a reduced model for Lower-Hybrid heating and Current-Drive (LHCD) and the quasi-linear turbulent transport model TGLF are crucial for long pulses predictions up to the Last Closed Flux Surface (LCFS). Using this workflow, a 100 s reference discharge was modeled and plasma kinetic profiles and loop voltage were quantitatively well matched. In preparation for the recent long duration experiments, non-inductive current-drive actuators (I P , n e , P LHCD ) were varied to determine the operational domain going towards fully non-inductive discharges. In particular, decreasing the plasma current is shown to ease the access to such conditions, with a careful monitoring of (n e , P LHCD ) to avoid machine limitations. In addition, post-prediction experiments conducted within the investigated parameter range validated the predicted dependencies and were shown to be in quantitative agreement. Exploratory work on the use of ECCD for MHD stability purpose is also introduced.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ice Protection of Turbojet Engines by Inertia Separation of Water II : Single-offset-duct System

Investigation of a single-offset-duct system designed to prevent entrance of water into a turbojet engine was conducted on a half-scale nacelle model. An investigation was made to determine ram-pressure recovery and radial velocity profiles at the compressor section and icing characteristics of such a duct system. At a design inlet velocity of 0.77, the maximum ram-pressure recovery attained with effective water-separating inlet was 77 percent, which is considerably less than attainable with a direct-ram inlet. Continuous heating of the accessory-housing surface would be required for inlets that have a small ice storage space.

NOSE SHAPE - DUCTED BODIES↗

Preparation of low strategic metal content superalloys

The properties of modified NIMONIC 115 and UDIMET 720 with reduced levels of cobalt were evaluated. Vacuum induction melted and vacuum arc remelted ingots were hot rolled to 3/4 inch diameter bar. Hot workability was evaluated in terms of the ingot rolling behavior and the hot ductility of the as-rolled bar. Variations in workability and bar ductility were correlated to variations in incipient melting temperature and gamma prime solvus, both of which varied with cobalt content. Heat treatments were defined to yield, as far as possible, similar structures from alloy to alloy. At the lowest cobalt levels N-115 workability was severely limited and the alloys could not be worked to bar. It is suggested that incipient melting in combination with heavy grain boundary carbide precipitation reduced ingot workability. Final heat treatment of modified alloys was difficult in the situation where the gamma prime solvus temperature was close to the incipient melting point, indicating that it may not be feasible to fully solution low cobalt alloys to obtain the large grain size required for optimum creep resistance.

Sczerzenie, F. E.↗

Influence of Crucible Materials on High-temperature Properties of Vacuum-melted Nickel-chromium-cobalt Alloy

A study of the effect of induction-vacuum-melting procedure on the high-temperature properties of a titanium-and-aluminum-hardened nickel-base alloy revealed that a major variable was the type of ceramic used as a crucible. Reactions between the melt and magnesia or zirconia crucibles apparently increased high-temperature properties by introducing small amounts of boron or zirconium into the melts. Heats melted in alumina crucibles had relatively low rupture life and ductility at 1,600 F and cracked during hot-working as a result of deriving no boron or zirconium from the crucible.

MATERIALS, PROPERTIES - STRESS-RUPTURE↗

Magnetization, anomalous Barkhausen effect, and core loss of Supermendur under high temperature cycling.

The magnetization and core loss of Supermendur were measured up to 900 C under conditions of slow temperature cycling in vacuum. As a consequence of this heating, the coercivity at 25 C increased from 21 A/m to about 110 A/m. This increase is less than previously reported. A prominent anomalous Barkhausen effect, pinched-in hysteresis loops, and a magnetic viscosity field in excess of 20 A/m were observed in the range of 600 to 700 C. At 850 C, Supermendur had a coercivity of 23 A/m, a saturation induction exceeding 1.5 T, a core loss of 26 W/kg at 400 Hz, and a maximum induction of 1.5 T. Supermendur may be useful for high temperature soft magnetic material applications where some history dependence of properties and instability of minor loops at lower temperatures is acceptable.

Niedra, J. M.↗

The magnetic pumping of plasmas with sawtooth waveforms

The pumping of plasmas by sawtooth-waveform magnetic induction variations is studied theoretically and by means of computer simulations. A sawtooth is a cycle waveform that is characterized by a slow increase in the magnetic induction followed by a rapid drop in the induction. Two types of sawtooth pumping are analyzed, and the types classified as to whether or not the first adiabatic invariants of the plasma particles are conserved during the rapid drops in the magnetic induction. When the invariants are conserved, the sawtooth waveforms are found to be less efficient than square waves for pumping plasmas. When the adiabatic invariations are not conserved, the pumping efficiency is found to be a slight improvement over square waves. Both types of pumping are applied to a hypothetical tokamak plasma and it is concluded that neither type of sawtooth pumping is practical for heating magnetically confined fusion plasmas.

Borovsky, Joseph E.↗

Makeup and uses of a basic magnet laboratory for characterizing high-temperature permanent magnets

A set of instrumentation for making basic magnetic measurements was assembled in order to characterize high intrinsic coercivity, rare earth permanent magnets with respect to short term demagnetization resistance and long term aging at temperatures up to 300 C. The major specialized components of this set consist of a 13 T peak field, capacitor discharge pulse magnetizer; a 10 in. pole size, variable gap electromagnet; a temperature controlled oven equipped with iron cobalt pole piece extensions and a removable paddle that carries the magnetization and field sensing coils; associated electronic integrators; and sensor standards for field intensity H and magnetic moment M calibration. A 1 cm cubic magnet sample, carried by the paddle, fits snugly between the pole piece extensions within the electrically heated aluminum oven, where fields up to 3.2 T can be applied by the electromagnet at temperatures up to 300 C. A sample set of demagnetization data for the high energy Sm2Co17 type of magnet is given for temperatures up to 300 C. These data are reduced to the temperature dependence of the M-H knee field and of the field for a given magnetic induction swing, and they are interpreted to show the limits of safe operation.

Niedra, Janis M.↗

Pulsed plasmoid electric propulsion

A method of electric propulsion is explored where plasmoids such as spheromaks and field reversed configurations (FRC) are formed and then allowed to expand down a diverging conducting shell. The plasmoids contain a toroidal electric current that provides both heating and a confining magnetic field. They are free to translate because there are no externally supplied magnetic fields that would restrict motion. Image currents in the diverging conducting shell keep the plasmoids from contacting the wall. Because these currents translate relative to the wall, losses due to magnetic flux diffusion into the wall are minimized. During the expansion of the plasma in the diverging cone, both the inductive and thermal plasma energy are converted to directed kinetic energy producing thrust. Specific impulses can be in the 4000 to 20000 sec range with thrusts from 0.1 to 1000 Newtons, depending on available power.

Bourque, Robert F.↗