Search NASA⌕ Search

SEARCH · Search NASA

Results for “Infrared techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Advanced infrared astronomy

This task supports the application of infrared heterodyne spectroscopy and other high resolution techniques, as well as infrared arrays to ultra-high resolution studies of molecular constituents of planetary atmospheres. High spectral and spatial resolution measurement and analysis of individual spectral lines permits the retrieval of distributions of atmospheric molecular abundances and temperatures and thus, information on local photochemical processes. Determination of absolute line positions to better than 10(exp -8) permits direct measurement of gas velocities to a few m/sec and thus, the study of dynamics. Observations are made from ground based observatories.

Kostiuk, Theodor↗

A Fluorescent Source NDIR Carbon Monoxide Analyzer

This paper describes a new technique for measuring trace quantities of carbon monoxide by the nondispersive infrared (NDIR) methods. The technique uses the property of infrared fluorescence in a gas to generate a specific source of radiation which is an exact match of the absorption spectrum of the fundamental band of carbon monoxide. This results in an instrument with high sensitivity and specificity for CO. A novel method of referencing using an isotopic species of CO confers great stability on the instrument.

Link, W. T.↗

Peak2Patch: High-Fidelity Functional Group Identification through Attention-Based Fusion of Infrared and Mass Spectra

Identifying molecular structure based on spectroscopic readings is a key task in a variety of chemical and biological applications. Common spectroscopy techniques, such as Infrared (IR) Spectroscopy and Mass Spectrometry (MS), provide detailed information on the structure of molecular compounds but nonetheless require expert-level knowledge to decode. Machine learning has emerged as a potential solution for automating structure prediction from chemical spectra; however, current approaches generally focus on single sensor modalities, neglecting to leverage the complementary information contained within differing spectra. In this paper, we introduce Peak2Patch, a novel approach to fusion-enhanced prediction of functional groups from IR and mass spectra. First, we perform a detailed comparison of backbone networks for encoding both sparse mass spectra and dense IR spectra and demonstrate the superior performance of transformer neural networks over current state-of-the-art convolutional neural networks. Second, we evaluate three broad categories of fusion: early (raw feature), middle (deep feature), and late (decision) fusion, demonstrating the potential of a deep feature fusion-based approach. Lastly, we present Peak2Patch, our attention-based fusion scheme, which leverages cross-attention to mix features between encoded tokens of the two modalities. We validate our approach on a publicly available multimodal spectroscopic data set of 790k simulated molecules, demonstrating a large improvement in functional group prediction over both the previous state-of-the-art and our own strong single-modal baselines.

Jacobson, Philip [Sandia National Laboratories (SN↗

Summary of the nondestructive evaluation session

Advanced material systems and designs require improved nondestructive evaluation (NDE) techniques for quality control, failure analysis and properties monitoring. Some advanced NDE techniques such as infrared scanning systems, laser holographic applications and the use of the Mossbauer effect are outlined. Applications of these techniques are discussed for evaluating the new space shuttle external insulation materials, aircraft structures and engine components, and precursors to crack initiation and growth.

Stinebring, R. C.↗

Measured Boundary Layer Transition and Rotor Hover Performance at Model Scale

An experiment involving a Mach-scaled, 11:08 f t: diameter rotor was performed in hover during the summer of 2016 at NASA Langley Research Center. The experiment investigated the hover performance as a function of the laminar to turbulent transition state of the boundary layer, including both natural and fixed transition cases. The boundary layer transition locations were measured on both the upper and lower aerodynamic surfaces simultaneously. The measurements were enabled by recent advances in infrared sensor sensitivity and stability. The infrared thermography measurement technique was enhanced by a paintable blade surface heater, as well as a new high-sensitivity long wave infrared camera. The measured transition locations showed extensive amounts, x=c>0:90, of laminar flow on the lower surface at moderate to high thrust (CT=s > 0:068) for the full blade radius. The upper surface showed large amounts, x=c > 0:50, of laminar flow at the blade tip for low thrust (CT=s < 0:045). The objective of this paper is to provide an experimental data set for comparisons to newly developed and implemented rotor boundary layer transition models in CFD and rotor design tools. The data is expected to be used as part of the AIAA Rotorcraft SimulationWorking Group

Overmeyer, Austin D.↗

Data Analytics for Concrete Structural Health Monitoring in Nuclear Power Plants

Assessment and management of aging concrete structures in nuclear power plants require a more systematic approach than simple reliance on existing code margins of safety. Structural health monitoring of concrete structures aims to understand the current health condition of a structure based on heterogeneous measurements to produce high-confidence actionable information regarding structural integrity that supports operational and maintenance decisions. This ongoing research project is seeking to develop a probabilistic framework for health diagnosis and prognosis of aging concrete structures in a nuclear power plant that is subjected to physical, chemical, environment, and mechanical degradation. In this paper, experimental set up at Vanderbilt University’s Laboratory for Systems Integrity and Reliability is used to research effective combinations of full field techniques, which include infrared thermography, digital image correlation, and ultrasonic measurement. The full-field imaging data collected were processed using contour mapping technique to identify holes in a concrete slab. The techniques discussed and presented in this paper allow diagnosis of damage. The framework will enable plant operators to make risk informed decisions on the struc-tural integrity, remaining useful life, and performance of concrete structures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Efficient computer algorithms for infrared astronomy data processing

Data processing techniques to be studied for use in infrared astronomy data analysis systems are outlined. Only data from space based telescope systems operating as survey instruments are considered. Resulting algorithms, and in some cases specific software, will be applicable for use with the infrared astronomy satellite (IRAS) and the shuttle infrared telescope facility (SIRTF). Operational tests made during the investigation use data from the celestial mapping program (CMP). The overall task differs from that involved in ground-based infrared telescope data reduction.

Pelzmann, R. F., Jr.↗

Quantum state-resolved gas/surface reaction dynamics probed by reflection absorption infrared spectroscopy

We report the design and characterization of a new molecular-beam/surface-science apparatus for quantum state-resolved studies of gas/surface reaction dynamics combining optical state-specific reactant preparation in a molecular beam by rapid adiabatic passage with detection of surface-bound reaction products by reflection absorption infrared spectroscopy (RAIRS). RAIRS is a non-invasive infrared spectroscopic detection technique that enables online monitoring of the buildup of reaction products on the target surface during reactant deposition by a molecular beam. The product uptake rate obtained by calibrated RAIRS detection yields the coverage dependent state-resolved reaction probability S({theta}). Furthermore, the infrared absorption spectra of the adsorbed products obtained by the RAIRS technique provide structural information, which help to identify nascent reaction products, investigate reaction pathways, and determine branching ratios for different pathways of a chemisorption reaction. Measurements of the dissociative chemisorption of methane on Pt(111) with this new apparatus are presented to illustrate the utility of RAIRS detection for highly detailed studies of chemical reactions at the gas/surface interface.

36 MATERIALS SCIENCE↗

Infrared temperature mapping in elastohydrodynamic lubrication

An improved technique for the measurement of temperature distributions in an EHD conjunction is presented. The technique reported here employs the infrared radiation emitted by the EHD conjunction and appears more rigorous, more reliable, and less cumbersome than that reported previously by the authors. Detailed mapping of fluid temperature (averaged through the thickness) and the ball surface temperature can be obtained. These temperature distributions have been reported for a naphthenic mineral oil for peak Hertz pressures of 1.05 and 1.51 GN/sq m (148 and 219 kpsi), at sliding speeds ranging from 0.35 to 12.7 m/s (13.4 to 500 ips) and a bath temperature of 40 C.

Ausherman, V. K.↗

Spatially resolved multimodal vibrational spectroscopy under high pressures

In this perspective, we discuss the potential impact on in situ studies under controlled environments of a novel multimodal spectroscopic technique, optical photothermal infrared + Raman spectroscopy, which enables the simultaneous collection of infrared and Raman scattering spectra, along with hyperspectral imaging and chemical imaging with wavelength-independent sub-500 nm spatial resolution. A brief review of the current literature regarding the O-PTIR technique is presented along with recent work from our own lab on determining the crystallinity of soft and inorganic materials. The results highlight the possibility of resolving differences in the crystallinity of soft materials associated with changes in material processing. Here, we also demonstrate the first reported use of a diamond anvil cell with simultaneous infrared and Raman measurements that showcases, using a high energy material as an example, the potential use of O-PTIR spectroscopy in diamond anvil cell techniques.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Intense 1.54 {mu}m fluorescence of Er{sup 3+}/Yb{sup 3+} codoped phosphate glass and the three-photon phenomenon of near infrared upconversion luminescence

Transparent P{sub 2}O{sub 5}-CaO-Na{sub 2}O glasses codoped with Er{sup 3+} and Yb{sup 3+} ions were fabricated by high-temperature melting technique. Strong near infrared and visible upconversion luminescence were observed under 975 nm laser diode excitation, and the luminescence processes were explained in details. For 1.54 {mu}m band, the calculated peak emission cross sections is 1.04x10{sup -20} cm{sup 2}, and it is better than that in germinate, tellurite, silicate, and other phosphate glasses. The near infrared upconversion emission around 828 nm contains two-photon and three-photon processes, and it is attributed to the transition {sup 4}S{sub 3/2}{yields}{sup 4}I{sub 13/2}, which enhances the population of the upper level for 1.54 {mu}m laser emission and reduces the energy loss due to upconversion. Efficient near infrared fluorescence indicates Er{sup 3+}/Yb{sup 3+} codoped phosphate glass is a promising laser and amplifier material.

36 MATERIALS SCIENCE↗

Polyethylene glycol (PEG) assisted size-controlled SnO{sub 2} nanoparticles by sol-gel process

Tetragonal phase tin oxide (SnO{sub 2}) nanoparticles have been synthesized by sol–gel method using SnCl{sub 4}.5H{sub 2}O and polyethylene glycol (PEG) of different concentration. The phase, size and purity of the final products are characterized by X-ray diffraction (XRD). The morphology is confirmed by scanning electron microscopy (SEM) analysis. There exists relationship between the concentration of PEG and particle size of SnO{sub 2} nanoparticles. Increase in concentration of PEG caused the reduction of particle size of tin oxide nanoparticles. The results suggest that the concentration of PEG plays a significant role in determining the size of SnO{sub 2} nanoparticles synthesized via this method. The optical property of the product has been explored by Ultraviolet (UV-visible) and Fourier Transform Infrared (FTIR) spectroscopic techniques.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Hyperspectral Microscopy of Explosives Particles Using an External Cavity Quantum Cascade Laser

Using infrared hyperspectral imaging, we demonstrate microscopy of small particles of the explosives compounds RDX, tetryl, and PETN with near diffraction-limited performance. The custom microscope apparatus includes an external cavity quantum cascade laser illuminator scanned over its tuning range of 9.13-10.53 µm in four seconds, coupled with a microbolometer focal plane array to record infrared transmission images. We use the hyperspectral microscopy technique to study the infrared absorption spectra of individual explosives particles, and demonstrate sub-nanogram detection limits.

(110.4234) Multispectral & Hyperspectral Imaging↗

Monitoring for neuroprotection. New technologies for the new millennium

Monitoring for neuroprotection, like surgery, has placed on emphasis on minimal or non-invasiveness. Monitoring of parameters that truly reflect the degree of injury to the nervous system is another goal. Thus, two themes for the coming decade in neuromonitoring will be: (1) less-invasive monitoring; and (2) parameters that more closely reflect the etiological factors in ischemic or other neuroinjury. In this paper, we review neuromonitoring techniques and devices that can be used readily in the operating room or intensive care unit setting. Those that require transport of the patient to a special facility (e.g., for computed tomography or magnetic resonance imaging/spectroscopy) and those that have been in standard practice for neuromonitoring (e.g., electrophysiological monitoring--EEG, evoked potentials) are not considered. The two techniques considered in detail are (1) continuous multiparameter local brain tissue monitoring with microprobes, and (2) non-invasive continuous local brain tissue oxygenation monitoring by near infrared spectroscopy. Both techniques have been cleared by the Food and Drug Administration (FDA) for clinical use. The rationale for their use, the nature of the devices, and clinical results to date are reviewed. It is expected that both techniques will gain wide acceptance during the coming decade; further advances in neuromonitoring that can be expected further into the twenty-first century are also discussed.

Review↗

Photoluminescent and Thermoluminescent Studies of Dy{sup 3+} and Eu{sup 3+} Doped Y{sub 2}O{sub 3} Phosphors

Eu{sup 3+} doped and Dy{sup 3+} codoped yttrium oxide (Y{sub 2}O{sub 3}) phosphors have been prepared using solid-state reaction technique (SSR). The prepared phosphors were characterized by X-ray diffractometer (XRD), energy dispersive X-ray (EDX) spectroscopy, scanning electron microscopy (SEM) and Fourier transforms infrared spectroscopy (FTIR) techniques. Photoluminescence (PL) and Thermoluminescence (TL) properties were studied in detail. PL emission spectra were recorded for prepared phosphors under excitation wavelength 254 nm, which show a high intense peak at 613 nm for Y{sub 2}O{sub 3}:Dy{sup 3+}, Eu{sup 3+} (1:1.5 mol %) phosphor. The correlated color temperature (CCT) and CIE analysis have been performed for the synthesized phosphors. TL glow curves were recorded for Eu{sup 3+}doped and Dy{sup 3+}codoped phosphors to study the heating rate effect and dose response. The kinetic parameters were calculated using peak shape method for UV and γ exposures through computerized glow curve deconvolution (CGCD) technique. The phosphors show second order kinetics and activation energies varying from 5.823 × 10{sup − 1} to 18.608 × 10{sup − 1} eV.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Interfacial transmetallation synthesis of a platinadithiolene nanosheet as a potential 2D topological insulator

The construction of two-dimensional metal complex materials is fascinating because of the structural and functional diversity of these materials. Previously, we have reported the synthesis of electroconductive nickelladithiolene (NiDT) and palladadithiolene (PdDT) nanosheets using benzenehexathiol (BHT). Down the group from Ni, Pd to Pt, there is a distinct positive shift in the reduction potential; as a result, it becomes synthetically more challenging to stabilize Pt 2+ than to form metallic Pt(0) in the presence of BHT as a reducing agent. Herein, a novel synthetic strategy for the preparation of platinadithiolene nanosheet (PtDT) using a dibutyltin-protected BHT ligand is reported, leading to transmetallation in the presence of dioxygen. Both free-standing stacked sheets and atomic layer sheets were obtained and characterized by microscopic techniques such as AFM, SEM, and TEM. To study the morphology of the sheets and determine their charge neutrality, X-ray photoelectron (XP) and infrared (IR) spectroscopic techniques were used. Powder X-ray diffraction analysis of the multilayer PtDT indicates a half-way slipped hexagonal configuration in the P 3¯1 m space group. The band structure of this PtDT exhibits a band gap at the Fermi level, which is different from that of NiDT in the staggered configuration, and a Dirac gap, indicating the possibility of 2D topological insulation at room temperature. PtDT is insulating but chemically activated by oxidation with I 2 to increase the conductivity by more than 106 folds up to 0.39 S cm –1 . The MDT sheets exhibit electrocatalytic activity for the hydrogen evolution reaction, and the activity order is NiDT < PdDT < PtDT.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Analysis of laser differential absorption remote sensing using diffuse reflection from the earth

A computer model analysis of an infrared laser differential absorption remote sensing technique (DARS) is presented. An infrared laser source operating at two or more wavelengths and a heterodyne detection system are considered to be mounted on either an aircraft or satellite platform to monitor the differential absorption between the laser source and the earth surface. The capability of this technique for measuring gas concentrations in the lower 5 kilometers of the atmosphere is emphasized. Numerical results are presented simulating measurements of vertical burdens of CO, NO, CH4, CO2, and O3. These results indicate that measurements of expected concentrations of these gases can be made with greater than 80% accuracy using realistic laser powers and system parameters.

Seals, R. K., Jr.↗

Non-invasive optical detection of glucose in cell culture nutrient medium

The objective of the proposed research was to begin the development of a non-invasive optical sensor for measuring glucose concentration in the output medium of cell cultures grown in a unique NASA bioreactor referred to as an integrated rotating-wall vessel (IRWV). The input, a bovine serum based nutrient media, has a known glucose concentration. The cells within the bioreactor digest a portion of the glucose. Thus, the non-invasive optical sensor is needed to monitor the decrease in glucose due to cellular consumption since the critical parameters for sustained cellular productivity are glucose and pH. Previous glucose sensing techniques have used chemical reactions to quantify the glucose concentration. Chemical reactions, however, cannot provide for continuous, real time, non-invasive measurement as is required in this application. Our effort while in the fellowship program was focused on the design, optical setup, and testing of one bench top prototype non-invasive optical sensor using a mid-infrared absorption spectroscopy technique. Glucose has a fundamental vibrational absorption peak in the mid-infrared wavelength range at 9.6 micron. Preliminary absorption data using a CO2 laser were collected at this wavelength for water based glucose solutions at different concentrations and one bovine serum based nutrient medium (GTSF) with added glucose. The results showed near linear absorption responses for the glucose-in-water data with resolutions as high at 108 mg/dl and as low as 10 mg/dl. The nutrient medium had a resolution of 291 mg/dl. The variability of the results was due mainly to thermal and polarization drifts of the laser while the decrease in sensitivity to glucose in the nutrient medium was expected due to the increase in the number of confounders present in the nutrient medium. A multispectral approach needs to be used to compensate for these confounders. The CO2 laser used for these studies was wavelength tunable (9.2 to 10.8 micrometers), however, it was to unstable across wavelengths to test the multispectral approach. From this research, further NASA support was obtained to continue the work throughout the year in which a more stable light source will be used at smaller, near-infrared, wavelengths. It is anticipated that a more compact, non-invasive, optical glucose sensor will be realized which can be used with a bioreactor on future space shuttle missions. It is also anticipated that a multispectral optical sensor may be used to determine the concentration of other molecules needed within the NASA bioreactor, such as fructose and galactose.

Cote, Gerald L.↗