The CMS Phase-2 Fast Beam Condition Monitor prototype test with beam

The Fast Beam Condition Monitor (FBCM) is a standalone luminometer for the High Luminosity LHC (HL-LHC) program of the CMS Experiment at CERN. The detector is under development and features a new, radiation-hard, front-end application-specific integrated circuit (ASIC) designed for beam monitoring applications. The achieved timing resolution of a few nanoseconds enables the measurement of both the luminosity and the beam-induced background. The ASIC, called FBCM23, features six channels with adjustable shaping times, enabling in-field fine-tuning. Each ASIC channel outputs a single binary asynchronous signal encoding time-of-arrival and time-over-threshold information. The FBCM is based on silicon-pad sensors, with two sensor designs presently being considered. This paper presents the results of tests of the FBCM detector prototype using both types of silicon sensors with hadron, muon, and electron beams. Irradiated FBCM23 ASICs and silicon-pad sensors were also tested to simulate the expected conditions near the end of the detector's lifetime in the HL-LHC radiation environment. Based on test results, direct bonding between the sensor and ASIC was chosen, and an optimal bias voltage and ASIC threshold for FBCM operation were proposed. The current design of the front-end test board was validated following the beam test and is now being used for the first front-end module, which is expected to be produced in summer 2025. These results represent a major step forward in validating the FBCM concept, first version of the firmware and establishing a reliable design path for the final detector.

Beam-line instrumentation (beam position and profi↗

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER↗

The IDEA detector concept for FCC-ee

A detector concept, named IDEA, optimized for the physics and running conditions at the FCC-ee is presented. After discussing the expected running conditions and the main physics drivers, a detailed description of the individual sub-detectors is given. These include: a very light tracking system with a powerful vertex detector inside a large drift chamber surrounded by a silicon wrapper, a high resolution dual readout crystal electromagnetic calorimeter, an HTS based superconducting solenoid, a dual readout fiber calorimeter and three layers of muon chambers embedded in the magnet flux return yoke. Some examples of the expected detector performance, based on fast and full simulation, are also given.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enhancing weak lensing redshift distribution characterization by optimizing the Dark Energy Survey Self-Organizing Map Photo-z method

Characterization of the redshift distribution of ensembles of galaxies is pivotal for large scale structure cosmological studies. In this work, we focus on improving the Self-Organizing Map (SOM) methodology for photometric redshift estimation (SOMPZ), specifically in anticipation of the Dark Energy Survey Year 6 (DES Y6) data. This data set, featuring deeper and fainter galaxies than DES Year 3 (DES Y3), demands adapted techniques to ensure accurate recovery of the underlying redshift distribution. We investigate three strategies for enhancing the existing SOM-based approach used in DES Y3: 1) Replacing the Y3 SOM algorithm with one tailored for redshift estimation challenges; 2) Incorporating $\textit{g}$-band flux information to refine redshift estimates (i.e. using $\textit{griz}$ fluxes as opposed to only $\textit{riz}$); 3) Augmenting redshift data for galaxies where available. These methods are applied to DES Y3 data, and results are compared to the Y3 fiducial ones. Our analysis indicates significant improvements with the first two strategies, notably reducing the overlap between redshift bins. By combining strategies 1 and 2, we have successfully managed to reduce redshift bin overlap in DES Y3 by up to 66$\%$. Conversely, the third strategy, involving the addition of redshift data for selected galaxies as an additional feature in the method, yields inferior results and is abandoned. Our findings contribute to the advancement of weak lensing redshift characterization and lay the groundwork for better redshift characterization in DES Year 6 and future stage IV surveys, like the Rubin Observatory.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The XLZD Design Book: towards the next-generation liquid xenon observatory for dark matter and neutrino physics

This report describes the experimental strategy and technologies for XLZD, the next-generation xenon observatory sensitive to dark matter and neutrino physics. In the baseline design, the detector will have an active liquid xenon target of 60 tonnes, which could be increased to 80 tonnes if the market conditions for xenon are favorable. It is based on the mature liquid xenon time projection chamber technology used in current-generation experiments, LZ and XENONnT. The report discusses the baseline design and opportunities for further optimization of the individual detector components. The experiment envisaged here has the capability to explore parameter space for Weakly Interacting Massive Particle (WIMP) dark matter down to the neutrino fog, with a 3σ evidence potential for WIMP-nucleon cross sections as low as 3 x 10 –49 cm 2 (at 40 GeV/c 2 WIMP mass). The observatory will also have leading sensitivity to a wide range of alternative dark matter models. It is projected to have a 3σ observation potential of neutrinoless double beta decay of 136 Xe at a half-life of up to 5.7 x 10 27 years. Additionally, it is sensitive to astrophysical neutrinos from the sun and galactic supernovae.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High Multiplicity Trigger for long-lived particles in CMS detector

Searches for long-lived particles (LLPs) at the CMS experiment often involve unconventional event topologies that are difficult to efficiently select using standard trigger strategies. To improve sensitivity to such signatures during LHC Run 3 operation, a dedicated High Multiplicity Trigger (HMT) has been developed and deployed in the CMS trigger system. The trigger targets events containing unusually large numbers of hits in the CMS cathode strip chamber (CSC) muon detectors, a characteristic signature of several LLP scenarios involving displaced decays in the muon system. The HMT implementation, trigger logic, rate dependence with pileup, and operational stability are described. Optimized hit multiplicity thresholds are used to maintain acceptable trigger rates under high-luminosity and high-pileup conditions while preserving high efficiency across a broad range of LLP lifetimes and kinematic regimes. The trigger performance is evaluated using both simulated event samples and proton-proton collision data collected during Run 3 of the LHC. The HMT substantially extends the CMS sensitivity to non-standard signatures associated with LLP decays and provides a flexible platform for future searches for physics beyond the Standard Model.

47 OTHER INSTRUMENTATION↗

Performance of the Particle-Identification Silicon-Telescope Array coupled with the VAMOS++ magnetic spectrometer

The Particle-Identification Silicon-Telescope Array (PISTA) is a new detection system designed for high-resolution studies of fission process induced by multi-nucleon transfer in inverse kinematics. It is specifically optimized for experiments with the VAMOS++ magnetic spectrometer at GANIL (Grand Accélérateur National d’Ions Lourds). The array comprises eight trapezoidal ΔE-E silicon telescopes arranged in a lamp shade configuration. Each telescope integrates two single-sided stripped silicon detectors, enabling target-like recoil identification, energy loss measurements, and trajectory reconstruction. Positioned in close proximity to the target, PISTA’s compact geometry achieves high-efficiency tracking of target-like recoils produced in multi-nucleon transfer reactions at Coulomb barrier energies. The spatial segmentation of the array allows precise determination of the mass and charge of the target-like nucleus, and excitation energy of fissioning systems. This work presents the particle identification and excitation energy reconstruction performances for the interactions of 238 U beam with 12 C target. An excitation energy resolution of 800 keV (FWHM) was determined together with mass resolution of 1.1% (FWHM). The combination of PISTA and VAMOS++ magnetic spectrometer enables unprecedented investigations of the fission process as a function of the excitation energy of the fissioning nucleus, particularly for exotic systems produced in transfer-induced reactions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A gravity-based mounting approach for large-scale cryogenic calorimeter arrays

Cryogenic calorimeters are among the leading technologies for searching for rare events. The CUPID experiment is exploiting this technology to deploy a tonne-scale detector to search for neutrinoless double-beta decay of 100 Mo. The CUPID collaboration proposed an innovative approach to assembling cryogenic calorimeters in a stacked configuration, held in position solely by gravity. This gravity-based assembly method is unprecedented in the field of cryogenic calorimeters and offers several advantages, including relaxed mechanical tolerances and simplified construction. To assess and optimize its performance, we constructed a medium-scale prototype hosting 28 Li 2 MoO 4 crystals and 30 Ge light detectors, both operated as cryogenic calorimeters at the Laboratori Nazionali del Gran Sasso (Italy). Despite an unexpected excess of noise in the light detectors, the results of this test proved (i) a thermal stability better than ±0.5 mK at 10 mK, (ii) a good energy resolution of Li 2 MoO 4 cryogenic calorimeters, (6.6 ± 2.2) keV FWHM at 2615 keV, and (iii) a Li 2 MoO 4 light yield measured by the closest light detector of 0.36 keV/MeV, sufficient to guarantee the particle identification requested by CUPID.