Search NASA⌕ Search

SEARCH · Search NASA

Results for “Intact”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Response of Graphite to Dynamic Loading and Hypervelocity Jet Impacts

The compressive strengths of three varieties of high purity graphite, PCEA, NBG-18, and NBG-25, as well as the depth of penetration of small-scale charges into these materials was experimentally determined. These grades are similar in density, ranging from 1.80 – 1.85 g/cc, and nominal apparent porosity, ranging from 18% to 20%, but provide a wide range in maximum grain or particle size from 10s to 1000s of µm. Two very different manufacturing methods are also represented; PCEA is extruded while NBG-18 and NBG-25 are iso-molded. The quasistatic and dynamic strengths of each grade were determined on a load frame and split-Hopkinson pressure bar, respectively. The depth of penetration (DOP) of two small-scale shaped charges, the Teledyne RP-1 and RP-4, was determined against graphite. The global response of the RP-4 impacts was markedly different as the PCEA samples remained intact while all the NBG-25 samples split into 2 or 3 pieces after the jet penetration had completed. However, for all tests, the trusted DOPs fell within 2 cm. Preliminary hydrocode modeling of the penetration events used existing models that were not designed for graphite. The results can be tuned to reasonably reproduce the DOP, but the wound channel geometry is not reproduced well. A model designed for graphite would need to represent graphite’s non-linear and energy dissipation characteristics.

36 MATERIALS SCIENCE↗

Pretest Modeling A Spent Nuclear Fuel Seismic Shake Test

The U.S. Department of Energy Spent Fuel and Waste Science and Technology (SFWST) program is planning to conduct a series of full-scale shake table tests to simulate hypothetical earthquake conditions and record the response of surrogate spent nuclear fuel (SNF) assemblies in a dry canister storage system mockup. The shake table motions will represent a range of hypothetical earthquake conditions at hypothetical locations in the continental U.S. to generally define the range of mechanical loads that SNF can be expected to experience during extended dry storage periods. This paper describes the pretest predictions made with LS-DYNA models of the mockup storage systems. The test will use two dry storage system configurations, a mockup vertical concrete cask (VCC) and a mockup horizontal storage module (HSM). The test will use a production-quality canister and basket. Within the canister will be four instrumented fuel assemblies with fuel rods containing surrogate mass and 28 instrumented dummy assemblies that are intended to match the mass and outer dimension of a fuel assembly. The finite element models include models of the VCC and HSM on the shake table to calculate the system level dynamic responses and separate single fuel assembly models to calculate stress and strain in fuel assembly components. Both types of models include nonlinear behavior like rod-to-rod contact and the ability for VCC’s to rock and slide. This paper presents the expected response of the VCC, HSM, and fuel assemblies to the shake table testing that is planned to start in April of 2024. The earthquake conditions represent seismic hazards in the 2,000-to-20,000-year return period range. The test data is expected to confirm the expectation that fuel rod cladding will remain intact, fuel assembly structural components like guide tubes will remain intact, and no significant VCC sliding or tipping will occur in the range of conditions to be tested with the shake table.

Klymyshyn, Nicholas A.↗

XPS study of thermal and electron-induced decomposition of Ni and Co acetylacetonate thin films for metal deposition

Optimizing thin metal film deposition techniques from metal-organic precursors such as atomic layer deposition, chemical vapor deposition (CVD), or electron beam-induced deposition (EBID) with the help of surface science analysis tools in ultrahigh vacuum requires a contamination-free precursor delivery technique, especially in the case of the less volatile precursors. For this purpose, the preparation of layers of undecomposed Ni(acac){sub 2} and Co(acac){sub 2} was tried via pulsed spray evaporation of a liquid solution of the precursors in ethanol into a flow of nitrogen on a CVD reactor. Solvent-free layers of intact precursor molecules were obtained when the substrate was held at a temperature of 115 °C. A qualitative comparison of thermally initiated and electron-induced precursor decomposition and metal center reduction was carried out. All deposited films were analyzed with respect to chemical composition quasi in situ by x-ray photoelectron spectroscopy. Thermally initiated decomposition yielded higher metal-to-metal oxide ratios in the deposit than the electron-induced process for which ratios of 60:40 and 20:80 were achieved for Ni and Co, resp. Compared to continuous EBID processes, all deposits showed low levels of carbon impurities of ∼10 at. %. Therefore, postdeposition irradiation of metal acetylacetonate layers by a focused electron beam and subsequent removal of intact precursor by dissolution in ethanol or by heating is proposed as electron beam lithography technique on the laboratory scale for the production of the metal nanostructures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Improvement of dose distribution in breast radiotherapy using a reversible transverse magnetic field Linac-MR unit

Purpose: To investigate the improvement in dose distribution in tangential breast radiotherapy using a reversible transverse magnetic field that maintains the same direction of Lorentz force between two fields. The investigation has a potential application in future Linac-MR units. Methods: Computed tomography images of four patients and magnetic fields of 0.25–1.5 Tesla (T) were used for Monte Carlo simulation. Two patients had intact breast while the other two had mastectomy. Simulations of planning and chest wall irradiation were similar to the actual clinical process. The direction of superior-inferior magnetic field for the medial treatment beam was reversed for the lateral beam. Results: For the ipsilateral lung and heart mean doses were reduced by a mean (range) of 45.8% (27.6%–58.6%) and 26.0% (20.2%–38.9%), respectively, depending on various treatment plan setups. The mean V{sub 20} for ipsilateral lung was reduced by 55.0% (43.6%–77.3%). In addition acceptable results were shown after simulation of 0.25 T magnetic field demonstrated in dose-volume reductions of the heart, ipsilateral lung, and noninvolved skin. Conclusions: Applying a reversible magnetic field during breast radiotherapy, not only reduces the dose to the lung and heart but also produces a sharp drop dose volume histogram for planning target volume, because of bending of the path of secondary charged particles toward the chest wall by the Lorentz force. The simulations have shown that use of the magnetic field at 1.5 T is not feasible for clinical applications due to the increase of ipsilateral chest wall skin dose in comparison to the conventional planning while 0.25 T is suitable for all patients due to dose reduction to the chest wall skin.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-I-14: Comparison of Iodine-Labeled and Indium-Labeled Antibody Biodistributions

Purpose: It is often assumed that animal biodistributions of novel proteins are not dependent upon the radiolabel used in their determination. In units of percent injected dose per gram of tissue (%ID/g), organ uptake results (u) may be obtained using either iodine or metal as radioactive labels. Iodination is preferred as it is a one-step process whereas metal labeling requires two chemical procedures and therefore more protein material. It is important to test whether the radioactive tag leads to variation in the uptake value. Methods: Uptakes of 3antibodies to Carcinoembryonic Antigen (CEA) were evaluated in a nude mouse model bearing 150 to 300 mg LS174T human colon cancer xenografts. Antibodies included diabody (56 kDa), minibody (80kDa) and intact M5A (150 kDa) anti-CEA cognates. Both radioiodine and indium-111 labels were used with uptakes evaluated at 7 time(t) points out to 96 h. Ratios (R) of u(iodine-label)/u(indium-label) were determined for liver, spleen, kidneys, lung and tumor. Results: Hepatic loss was rapid for diabody and minibody; by 24 h their R values were only 2%; i.e., uptake of iodine was 2% of that of indium for these 2 antibodies. By contrast, R for the intact cognate was 50% at that time point. Splenic results were similar. Tumor uptake ratios did not depend upon the antibody type and were 50% at 24 h. Conclusions: Relatively rapid loss of iodine relative to indium in liver and spleen was observed in lower mass antibodies. Tumor ratios were larger and independent of antibody type. Aside from tumor, the R ratio of uptakes depended on the antibody type. R values decreased monotonically with time in all tissues and for all cognates. Using this ratio, one can possibly correct iodine-based u (t) results so that they resemble radiometal-derived biodistributions.

60 APPLIED LIFE SCIENCES↗

SU-E-T-483: Treatment Planning Study of Volumetric Modulated Arc Therapy for Left-Sided Breast and Chestwall Cancers

Purpose: To perform the comparison of dose distributions and dosevolume- histograms generated by VMAT and conventional field-in-field technique for left-sided breast and chestwall cancers; to determine whether VMAT offers more dosimetric benefits than does the field-in-field technique. Methods: All VMAT and field-in-filed plans were produced in Eclipse(version 10). Five plans were generated for left-sided breast and leftsided chestwall with supraclavicular nodes, respectively. A clockwise arc (CW) and a counter-clockwise arc (CCW) were used with start and stop angles being 310o±10o and 140o±10o. Collimator angles were 30o for CW and 330o for CCW. The conformity index (CI) is the ratio of V95% over PTV. The homogeneity index (HI) is the ratio of the difference between D2% and D98% over the prescribed dose. The V5, as an indicator of low dose bath to organs-at-risk, was used for ipsilateral lung, heart, contralateral lung, and contralateral breast. The V20, as an indicator of radiation pneumonitis, was used for ipsilateral lung. Results: Breast/chestwall VMAT delivers much higher low dose bath to ipsilateral lung, contralateral lung and contralateral breast/chestwall for both intact breast and chestwall with nodes. V5 for heart is increased in VMAT plans. V20 for ipsilateral lung is lower in VMAT plans. PTV coverage is similar for both techniques. For one particular chestwall patient with supraclavicular and internal mammary nodes, VMAT offers superior dose coverage of PTVs with slightly more low-dose-wash to heart, contralateral lung and contralateral breast. Conclusion: This study indicates that there is generally no benefit using VMAT for left-sided intact breast, due to large low-dose-bath (5Gy) to normal tissues with insignificant improvement in PTV coverage. Dosimetric benefits will be seen in VMAT plans for some chestwall patients with large size, and/or internal mammary nodes, etc. Whether a chestwall patient is treated with VMAT should be carefully analyzed on an individual basis.

60 APPLIED LIFE SCIENCES↗

SU-F-BRD-06: Dosimetric Cost of a GTV Margin for Simultaneous Integrated Intra- Prostatic Boost Treatments

Purpose: Quantify the dosimetric cost for a margin around the MRI-defined high risk GTV for simultaneous integrated intra-prostatic boosts (SIIB) treated with RapidArc. Methods: For external beam radiotherapy of the prostate, a 3-7 mm PTV margin is typically used to account for setup and intra-fraction uncertainties after adjusting for inter-fraction motion. On the other hand, our current paradigm is to treat the MRI-defined high risk GTV with no margin. In this work, 11 patients treated SIIB (7 post-prostatectomy, 4 intact prostate) with RapidArc were re-planned with 1-5 mm margins around the GTV to quantify dosimetric effects. Two 358 degree, 10 MV RapidArcs were used to deliver 68 Gy (76.5 Gy boost) to the post-prostatectomy patients and 80 Gy (86 Gy boost) to the intact prostates. Paired, two tail t-tests were used to determine if there were any significant differences (p<0.05) in the total MUs and dosimetric parameters used to evaluate rectum, bladder, and PTV dose with and without margin. Results: The average GTV volume without margin was 8.1cc (2.8% of the PTV volume) while the average GTV volume with a 5 mm margin was 20.1cc (9.0% of the PTV volume). GTV volumes ranged from 0.2% of the PTV volume up to 33.0%. Despite these changes in volume, the only statistical difference was found for the rectal V65 Gy with a 5 mm margin (18.6% vs. 19.4%; p-value = 0.026) when all patients were considered as a single group. No difference was found when analyzed as two groups. The rectum V40Gy, bladder V40Gy and V65Gy, PTV Dmax and D95% or the total MUs did not show any significant difference for any margin. Conclusion: A 4 mm margin on the high risk GTV is possible with no statistically significant change in dosimetry or total MUs. Further work will assess the appropriate margin required for intra-prostatic boosts.

60 APPLIED LIFE SCIENCES↗

Experimental demonstration of passive acoustic imaging in the human skull cavity using CT-based aberration corrections

Purpose: Experimentally verify a previously described technique for performing passive acoustic imaging through an intact human skull using noninvasive, computed tomography (CT)-based aberration corrections Jones et al. [Phys. Med. Biol. 58, 4981–5005 (2013)]. Methods: A sparse hemispherical receiver array (30 cm diameter) consisting of 128 piezoceramic discs (2.5 mm diameter, 612 kHz center frequency) was used to passively listen through ex vivo human skullcaps (n = 4) to acoustic emissions from a narrow-band fixed source (1 mm diameter, 516 kHz center frequency) and from ultrasound-stimulated (5 cycle bursts, 1 Hz pulse repetition frequency, estimated in situ peak negative pressure 0.11–0.33 MPa, 306 kHz driving frequency) Definity™ microbubbles flowing through a thin-walled tube phantom. Initial in vivo feasibility testing of the method was performed. The performance of the method was assessed through comparisons to images generated without skull corrections, with invasive source-based corrections, and with water-path control images. Results: For source locations at least 25 mm from the inner skull surface, the modified reconstruction algorithm successfully restored a single focus within the skull cavity at a location within 1.25 mm from the true position of the narrow-band source. The results obtained from imaging single bubbles are in good agreement with numerical simulations of point source emitters and the authors’ previous experimental measurements using source-based skull corrections O’Reilly et al. [IEEE Trans. Biomed. Eng. 61, 1285–1294 (2014)]. In a rat model, microbubble activity was mapped through an intact human skull at pressure levels below and above the threshold for focused ultrasound-induced blood–brain barrier opening. During bursts that led to coherent bubble activity, the location of maximum intensity in images generated with CT-based skull corrections was found to deviate by less than 1 mm, on average, from the position obtained using source-based corrections. Conclusions: Taken together, these results demonstrate the feasibility of using the method to guide bubble-mediated ultrasound therapies in the brain. The technique may also have application in ultrasound-based cerebral angiography.

60 APPLIED LIFE SCIENCES↗

SU-F-T-220: Validation of Hounsfield Unit-To-Stopping Power Ratio Calibration Used for Dose Calculation in Proton Radiotherapy

Purpose: To validate the stoichiometric calibration of the Hounsfield Unit (HU) to Stopping Power Ratio (SPR) calibration used to commission a commercial treatment planning system (TPS) for proton radiotherapy dose calculation. Methods and Materials: The water equivalent thickness (WET) of several individual pig tissues (lung, fat, muscle, liver, intestine, rib, femur), mixed tissue samples (muscle/rib, ice/femur, rib/air cavity/muscle), and an intact pig head were measured with a multi-layer ionization chamber (MLIC). A CT scan of each sample was obtained and imported into a commercial TPS. The WET calculated by the TPS for each tissue sample was compared to the measured WET value to determine the accuracy of the HU-to-SPR calibration curve used by the TPS to calculate dose. Results: The WET values calculated by the TPS showed good agreement (< 2.0%) with the measured values for bone and all soft tissues except fat (3.1% difference). For the mixed tissue samples and the intact pig head measurements, the difference in the TPS and measured WET values all agreed to within 3.5%. In addition, SPR values were calculated from the measured WET of each tissue, and compared to SPR values of reference tissues from ICRU 46 used to generate the HU-to-SPR calibration for the TPS. Conclusion: For clinical scenarios where the beam passes through multiple tissue types and its path is dominated by soft tissues, we believe using an uncertainty of 3.5% of the planned beam range is acceptable to account for uncertainties in the TPS WET determination.

60 APPLIED LIFE SCIENCES↗

In situ diversity of metabolism and carbon use efficiency among soil bacteria

The central carbon (C) metabolic network harvests energy to power the cell and feed biosynthesis for growth. In pure cultures, bacteria use some but not all of the network’s major pathways, such as glycolysis and pentose phosphate and Entner-Doudoroff pathways. However, how these pathways are used in microorganisms in intact soil communities is unknown. Here, we analyzed the incorporation of 13 C from glucose isotopomers into phospholipid fatty acids. We showed that groups of Gram-positive and Gram-negative bacteria in an intact agricultural soil used different pathways to metabolize glucose. They also differed in C use efficiency (CUE), the efficiency with which a substrate is used for biosynthesis. Our results provide experimental evidence for diversity among microbes in the organization of their central carbon metabolic network and CUE under in situ conditions. These results have important implications for our understanding of how community composition affects soil C cycling and organic matter formation.

59 BASIC BIOLOGICAL SCIENCES↗

Molecular insights into the evolution of woody plant decay in the gut of termites

Plant cell walls represent the most abundant pool of organic carbon in terrestrial ecosystems but are highly recalcitrant to utilization by microbes and herbivores owing to the physical and chemical barrier provided by lignin biopolymers. Termites are a paradigmatic example of an organism’s having evolved the ability to substantially degrade lignified woody plants, yet atomic-scale characterization of lignin depolymerization by termites remains elusive. We report that the phylogenetically derived termite Nasutitermes sp. efficiently degrades lignin via substantial depletion of major interunit linkages and methoxyls by combining isotope-labeled feeding experiments and solution-state and solid-state nuclear magnetic resonance spectroscopy. Exploring the evolutionary origin of lignin depolymerization in termites, we reveal that the early-diverging woodroach Cryptocercus darwini has limited capability in degrading lignocellulose, leaving most polysaccharides intact. Conversely, the phylogenetically basal lineages of “lower” termites are able to disrupt the lignin-polysaccharide inter- and intramolecular bonding while leaving lignin largely intact. These findings advance knowledge on the elusive but efficient delignification in natural systems with implications for next-generation ligninolytic agents.

59 BASIC BIOLOGICAL SCIENCES↗

Structural Basis for Broad Detection of Genogroup II Noroviruses by a Monoclonal Antibody That Binds to a Site Occluded in the Viral Particle

Human noroviruses are genetically and antigenically highly divergent. Monoclonal antibodies raised in mice against one kind of norovirus virus-like particle (VLP), however, were found to have broad recognition. In this study, we present the crystal structure of the antigen-binding fragment (Fab) for one of these broadly reactive monoclonal antibodies, 5B18, in complex with the capsid-protruding domain from a genogroup II genotype 10 (GII.10) norovirus at 3.3-{angstrom} resolution and, also, the cryo-electron microscopy structure of the GII.10 VLP at {approx}10-{angstrom} resolution. The GII.10 VLP structure was more similar in overall architecture to the GV.1 murine norovirus virion than to the prototype GI.1 human norovirus VLP, with the GII.10 protruding domain raised {approx}15 {angstrom} off the shell domain and rotated {approx}40{sup o} relative to the GI.1 protruding domain. In the crystal structure, the 5B18 Fab bound to a highly conserved region of the protruding domain. Based on the VLP structure, this region is involved in interactions with other regions of the capsid and is buried in the virus particle. Despite the occluded nature of the recognized epitope in the VLP structure, enzyme-linked immunosorbent assay (ELISA) binding suggested that the 5B18 antibody was able to capture intact VLPs. Together, the results provide evidence that the norovirus particle is capable of extreme conformational flexibility, which may allow for antibody recognition of conserved surfaces that would otherwise be buried on intact particles.

59 BASIC BIOLOGICAL SCIENCES↗

Myosin head orientation: a structural determinant for the Frank-Starling relationship

The cellular mechanism underlying the Frank-Starling law of the heart is myofilament length-dependent activation. The mechanism(s) whereby sarcomeres detect changes in length and translate this into increased sensitivity to activating calcium has been elusive. Small-angle X-ray diffraction studies have revealed that the intact myofilament lattice undergoes numerous structural changes upon an increase in sarcomere length (SL): lattice spacing and the I{sub 1,1}/I{sub 1,0} intensity ratio decreases, whereas the M3 meridional reflection intensity (I{sub M3}) increases, concomitant with increases in diastolic and systolic force. Using a short ({approx}10 ms) X-ray exposure just before electrical stimulation, we were able to obtain detailed structural information regarding the effects of external osmotic compression (with mannitol) and obtain SL on thin intact electrically stimulated isolated rat right ventricular trabeculae. We show that over the same incremental increases in SL, the relative changes in systolic force track more closely to the relative changes in myosin head orientation (as reported by IM3) than to the relative changes in lattice spacing. We conclude that myosin head orientation before activation determines myocardial sarcomere activation levels and that this may be the dominant mechanism for length-dependent activation.

59 BASIC BIOLOGICAL SCIENCES↗

Mine Flooding History of a Regional Below-Drainage Coalfield Dominated by Barrier Leakage (1970–2014)

A 44-year record of water level fluctuations in a series of adjacent closed underground mines documents the history of closure and mine flooding in the Fairmont Coalfield, one of the oldest coal mining districts in the Pittsburgh coal basin, West Virginia, USA. As closures proceeded and mines began to flood, US environmental regulations were first enacted mandating mine water control and treatment, rendering uncontrolled surface discharges unacceptable. The purpose of this study is to present this flooding history and to identify critical events that determined how mine pools evolved in this case. Also examined is the strategy developed to control and treat water from these mines. Flooding is visualized using both water level hydrographs and mine flooding maps with the latter constructed assuming mine water hydraulic continuity between one or more mines. The earliest flooding formed small pools within near-surface mines closed prior to 1962 yet still pumped following closure to minimize leaking into adjacent still-active workings. These subpools gradually enlarged and merged as more closures occurred and the need for protective pumping was removed, forming what is today referred to as the unconfined Fairmont Pool. Later, deeper mines, separated by intact updip barriers from the Fairmont Pool, were closed and flooded more gradually, supplied in large part by leakage from the Fairmont Pool. By 1985, all mines except 2 had closed and by 1994 all had fully flooded, with the Fairmont Pool interconnected to deeper single mine pools via barrier leakage. As protective pumping ceased, the Fairmont Pool rose to a water level 3 m higher than surface drainage elevation and in 1997 discharged from an undermined section of Buffalo Creek near the Monongahela River. The principal mine operator in the basin then designed a pumping system to transfer water from the Fairmont Pool to their existing treatment facilities to the north, thus terminating the discharge. It may be concluded that the progress of mine flooding was influenced by mining history and design, by the timing of closures, by barrier leakage conditions, and by geologic structure. A key element in how flooding proceeded was the presence of a series of intact barriers separating deep from shallow mines. The shallow mines closed and flooded early, but then lost sufficient water by barrier leakage into the deeper mines to delay the completion of flooding until after the deep mines had all closed and flooded as well. Intensive mine water control has continued from the 1997 breakout to the present. The final water control scheme was likely unanticipated and serendipitous; future district-wide mining efforts should be advised to consider in advance closeout strategies to control mine water postmining.

Donovan, Joseph J.↗

Nuclear Canister Corrosion Detection

The software titled "nccd" is used for running residual neural networks (ResNets) on images of nuclear canisters. The software provides only the code for the implementation (based on the fastai library), but it does not share the image data. The compute code allows the use of residual nets (and more generally of other deep learning models) for classifying images from nuclear canisters as corroded. or intact. An image is considered to be corroded if it contains pitting or stress corrosion cracks. The code trains ResNets on image tiles extracted from original images from nuclear canisters, and then implements a classification rule, which can be applied to a validation set to decide if each original image is corroded or intact. The software automates the process of using images taken from nuclear canisters to detect corrosion. It provides also scope for future research directions on the basis of the existing research and code.

Papamarkou, Theodore↗

Selective Equatorial Sclera Crosslinking in the Orbit Using a Metal-Coated Polymer Waveguide

Purpose: Photochemical crosslinking of the sclera is an emerging technique that may prevent excessive eye elongation in pathologic myopia by stiffening the scleral tissue. To overcome the challenge of uniform light delivery in an anatomically restricted space, we previously introduced the use of flexible polymer waveguides. We presently demonstrate advanced waveguides that are optimized to deliver light selectively to equatorial sclera in the intact orbit. Methods: Our waveguides consist of a polydimethylsiloxane cladding and a polyurethane core, coupled to an optical fiber. A reflective silver coating deposited on the top and side surfaces of the waveguide prevents light leakage to nontarget, periorbital tissue. Postmortem rabbits were used to test the feasibility of in situ equatorial sclera crosslinking. Tensometry measurements were performed on ex vivo rabbit eyes to confirm a biomechanical stiffening effect. Results: Metal-coated waveguides enabled efficient light delivery to the entire circumference of the equatorial sclera with minimal light leakage to the periorbital tissues. Blue light was delivered to the intact orbit with a coefficient of variation in intensity of 22%, resulting in a 45 ± 11% bleaching of riboflavin fluorescence. A 2-fold increase in the Young's modulus at 5% strain (increase of 92% P < 0.05, at 25 J/cm 2 ) was achieved for ex vivo crosslinked eyes. Conclusions: Flexible polymer waveguides with reflective, biocompatible surfaces are useful for sclera crosslinking to achieve targeted light delivery. We anticipate that our demonstrated procedure will be applicable to sclera crosslinking in live animal models and, potentially, humans in vivo.

59 BASIC BIOLOGICAL SCIENCES↗

Microfluidic molecular assay platform for the detection of miRNAs, mRNAs, proteins, and post-translational modifications at single-cell resolution

In this study, cell signaling is a dynamic and complex process. A typical signaling pathway may begin with activation of cell surface receptors, leading to activation kinase cascade that culminates in induction of mRNA and non-coding miRNA production in the nucleus, followed by modulation of mRNA expression by miRNAs in the cytosol, and end with production of proteins in response to the signaling pathway. Signaling pathways involve proteins, miRNA, and mRNAs, along with various forms of transient post-translational modifications, and detecting each type of signaling molecule requires categorically different sample preparation methods such as Western blotting for proteins, PCR for nucleic acids, and flow cytometry for post-translational modifications. Since we know that cells in populations behave heterogeneously1, especially in the cases of stem cells, cancer, and hematopoiesis, there is need for a new technology that provides capability to detect and quantify multiple categories of signaling molecules in intact single cells to provide a comprehensive view of the cell’s physiological state. In this technical brief, we describe our microfluidic platform with a portfolio of customized molecular assays that can detect nucleic acids, proteins, and post-translational modifications in single intact cells with >95% reduction in reagent requirement in under 8 hours.

42 ENGINEERING↗

Spectral probabilities of top-down tandem mass spectra

In mass spectrometry (MS)-based proteomics, accurate estimation of statistical signicance of peptide and protein identications is desired for determining whether they are actually correct. Probabilistic models, such as the generating function method, have been successfully applied to compute statistical signicance of peptide-spectrum matches (PSMs) in bottom-up MS, but it is limited to PSMs of short peptides without post-translational modications (PTMs). Recently, top-down MS has be- come available in many laboratories, which often identies intact proteins with PTMs. In this paper, we propose an extended generating function (EGF) method for accurately computing statistical signicance of protein- spectrum matches (PrSMs) with PTMs.

59 BASIC BIOLOGICAL SCIENCES↗