At least 379 records · Page 21

A Scintillation Counter System Design To Detect Antiproton Annihilation using the High Performance Antiproton Trap(HiPAT)

The High Performance Antiproton Trap (HiPAT), a system designed to hold up to l0(exp 12) charge particles with a storage half-life of approximately 18 days, is a tool to support basic antimatter research. NASA's interest stems from the energy density represented by the annihilation of matter with antimatter, 10(exp 2)MJ/g. The HiPAT is configured with a Penning-Malmberg style electromagnetic confinement region with field strengths up to 4 Tesla, and 20kV. To date a series of normal matter experiments, using positive and negative ions, have been performed evaluating the designs performance prior to operations with antiprotons. The primary methods of detecting and monitoring stored normal matter ions and antiprotons within the trap includes a destructive extraction technique that makes use of a micro channel plate (MCP) device and a non-destractive radio frequency scheme tuned to key particle frequencies. However, an independent means of detecting stored antiprotons is possible by making use of the actual annihilation products as a unique indicator. The immediate yield of the annihilation event includes photons and pie mesons, emanating spherically from the point of annihilation. To "count" these events, a hardware system of scintillators, discriminators, coincident meters and multi channel scalars (MCS) have been configured to surround much of the HiPAT. Signal coincidence with voting logic is an essential part of this system, necessary to weed out the single cosmic ray events from the multi-particle annihilation shower. This system can be operated in a variety of modes accommodating various conditions. The first is a low-speed sampling interval that monitors the background loss or "evaporation" rate of antiprotons held in the trap during long storage periods; provides an independent method of validating particle lifetimes. The second is a high-speed sample rate accumulating information on a microseconds time-scale; useful when trapped antiparticles are extracted against a target, providing an indication of quantity. This paper details the layout of this system, setup of the hardware components around HiPAT, and applicable checkouts using normal matter radioactive sources.

Martin, James J.↗

Sea ice breakup and freeze-up indicators for users of the Arctic coastal environment

Abstract. The timing of sea ice retreat and advance in Arctic coastal waters varies substantially from year to year. Various activities, ranging from marine transport to the use of sea ice as a platform for industrial activity or winter travel, are affected by variations in the timing of breakup and freeze-up, resulting in a need for indicators to document the regional and temporal variations in coastal areas. The primary objective of this study is to use locally based metrics to construct indicators of breakup and freeze-up in the Arctic and subarctic coastal environment. The indicators developed here are based on daily sea ice concentrations derived from satellite passive-microwave measurements. The “day of year” indicators are designed to optimize value for users while building on past studies characterizing breakup and freeze-up dates in the open pack ice. Relative to indicators for broader adjacent seas, the coastal indicators generally show later breakup at sites known to have landfast ice. The coastal indicators also show earlier freeze-up at some sites in comparison with freeze-up for broader offshore regions, likely tied to earlier freezing of shallow-water regions and areas affected by freshwater input from nearby streams and rivers. A factor analysis performed to synthesize the local indicator variations shows that the local breakup and freeze-up indicators have greater spatial variability than corresponding metrics based on regional ice coverage. However, the trends towards earlier breakup and later freeze-up are unmistakable over the post-1979 period in the synthesized metrics of coastal breakup and freeze-up and the corresponding regional ice coverage. The findings imply that locally defined indicators can serve as key links between pan-Arctic or global indicators such as sea ice extent or volume and local uses of sea ice, with the potential to inform community-scale adaptation and response.

54 ENVIRONMENTAL SCIENCES↗

Urban change detection procedures using Landsat digital data

Landsat multispectral scanner data was applied to an urban change detection problem in Denver, CO. A dichotomous key yielding ten stages of residential development at the urban fringe was developed. This heuristic model allowed one to identify certain stages of development which are difficult to detect when performing digital change detection using Landsat data. The stages of development were evaluated in terms of their spectral and derived textural characteristics. Landsat band 5 (0.6-0.7 micron) and texture data produced change detection maps which were approximately 81 percent accurate. Results indicated that the stage of development and the spectral/textural features affect the change in the spectral values used for change detection. These preliminary findings will hopefully prove valuable for improved change detection at the urban fringe.

Jensen, J. R.↗

Cardiovascular Adaptations to Long Duration Head-Down Tilt Bed Rest

INTRODUCTION: Orthostatic hypotension is a serious risk for crewmembers returning from spaceflight. Numerous cardiovascular mechanisms have been proposed to account for this problem, including vascular and cardiac dysfunction, which we studied during bed rest. METHODS: Thirteen subjects were studied before and during bed rest. Statistical analysis was limited to the first 49-60 days of bed rest, and compared to pre-bed rest data. Ultrasound data were collected on vascular and cardiac structure and function. Tilt testing was conducted for 30 minutes or until presyncopal symptoms intervened. RESULTS: Plasma volume was significantly reduced by day 7 of bed rest. Flow-mediated dilation in the leg was significantly increased at bed rest day 49. Arterial responses to nitroglycerin differed in the arm and leg, but did not change as a result of bed rest. Intimal-medial thickness markedly decreased at bed rest days 21, 35 and 49. Several cardiac functional parameters including isovolumic relaxation time, ejection time and myocardial performance index were significantly increased (indicating a decrease in cardiac function) during bed rest. There was a trend for decreased orthostatic tolerance following 60 days of bed rest. DISCUSSION: These data suggest that 6 head-down tilt bed rest alters cardiovascular structure and function in a pattern similar to short duration spaceflight. Additionally, the vascular alterations are primarily seen in the lower body, while vessels of the upper body are unaffected. KEY WORDS: spaceflight, orthostatic intolerance, hypotension, fluid-shift, plasma volume

Platts, Steven H.↗

Mapping and Characterizing the Visual Impacts of the Existing US Wind Turbine Fleet

Visual impacts of wind turbines have been a persistent concern for wind energy development in the United States (US) for decades and remain a major source of project delays and cancellations. Assessments of visual impacts are frequently performed at a local scale for individual projects, but a comprehensive understanding of broader geographic patterns in visual impacts across the US is lacking. This paper presents a visual impact assessment of the existing land-based wind turbine fleet of the contiguous United States (CONUS). The assessment combines geographic information systems and 3D simulation methods to account for key factors driving the visual magnitude of impacts from the installed turbines. The results indicate that, despite the deployment of approximately 70,000 turbines and over 144 gigawatts of land-based wind in the CONUS, the visual impacts are very small when measured as a proportion of land area, population, and sensitive visual resources. Nonetheless, visual impacts are not evenly distributed: people experience a concentrated share in a small number of natural settings, primarily including plains, prairies, and deserts. Finally, we find that although increased density of wind development consistently leads to visual impacts across a greater proportion of land, it does not always lead to impacts to a greater share of the population. These findings suggest that visual impacts from wind energy are generally well-mitigated across the CONUS to date but also highlight the need for a deeper understanding of landscape sensitivity and individual perceptions of wind turbines in the most heavily impacted natural settings.

3D simulation↗

Highly Concentrated Electrolytes: Electrochemical and Physicochemical Characteristics of LiPF 6 in Propylene Carbonate Solutions

Highly concentrated electrolytes (HCEs) based on LiPF 6 in propylene carbonate (PC) have been examined as lithium-ion battery electrolytes. These HCEs have lower ionic conductivities and higher viscosities than ethylene carbonate (EC) electrolytes with 1.2 M LiPF 6 , but they have higher Li + ion transference numbers. Electrochemical cycling behaviour of LiNi 0.8 Co 0.015 Al 0.05 O 2 //graphite cells with 3.2 M LiPF 6 in PC resembles that of cells with EC-based electrolytes; the HCE cells have higher impedance, which can be lowered by increasing test temperature. By employing Raman and infrared spectroscopy, combined with density functional theory and ab initio molecular dynamics simulations, we reveal that the Li + solvation structure and speciation are key factors that determine cell performance. Two distinct regimes are observed as a function of salt concentration—in the conventional regime, the solvation number (SN) is mostly constant, while in the HCE regime it decreases linearly. Graphite exfoliation is suppressed only at very high salt concentrations ( > 2.4 M), where [ PC ] free /[Li + ] < 1 and P F 6 − f r e e > P C f r e e . Results from the Advanced Electrolyte Model indicate that Li + desolvation improves at higher LiPF 6 concentrations, thereby mitigating PC co-intercalation into the graphite. However, Li + ion transport is hindered in the HCEs, which increases impedance at both the oxide-positive and graphite-negative electrodes.

25 ENERGY STORAGE↗

Sterilization of N95 Respirators via Gamma Radiation: Comparison of Post-sterilization Efficacy

This study evaluated gamma irradiation for sterilization and reuse of two models of N95 respirators after gamma radiation sterilization as a method to increase availability of N95 respirators during a shortage. The Sandia National Laboratories Gamma Irradiation Facility was used to irradiate two different models of N95 filtering facepiece respirators at doses ranging from 0 kGy(tissue) to 50 kGy(tissue). The following tests were used to determine the efficacy of the respirator after irradiation sterilization: Ambient Aerosol Condensation Nuclei Counter Quantitative Fit Test, tensile test, strain cycling, oscillatory dynamic mechanical analysis, microscopic image analysis of fiber layers, and electrostatic field measurements. Both of the respirator models exhibited statistically significant changes after gamma irradiation as shown by the Quantitative Fit Test, electrostatic testing and the aerosol testing. The change in electrostatic charge of the filter was correlated with a reduction in capturing particles near the 200 nm size by approximately 40-50%. Both tested respirators showed statistically significant changes associated with gamma sterilization. However, our results indicate that choices in materials and manufacturing methods to achieve N95 filtration lead to different magnitudes of damage when exposed to gamma radiation at sterilization relevant doses. This damage results in lower filtration performance. While our sample size (2 different types of respirators) was small, we did observe a change in electrostatic properties on a filter layer that coincided with the failure on the Quantitative Fit Test and reduction in aerosol filtering efficiency. Key Words: N95 respirators, respirators, airborne transmission, pandemic prevention, COVID-19, gamma sterilization

COVID-19↗

Performance Characterization of High Energy Commercial Lithium-ion Cells

The NASA Glenn Research Center Electrochemistry Branch performed characterization of commercial lithium-ion cells to determine the cells' performance against Exploration Technology Development Program (ETDP) Key Performance Parameters (KPP). The goals of the ETDP Energy Storage Project require significant improvements in the specific energy of lithium-ion technology over the state-of-the-art. This work supports the high energy cell development for the Constellation customer Lunar Surface Systems (LSS). In support of these goals, testing was initiated in September 2009 with high energy cylindrical cells obtained from Panasonic and E-One Moli. Both manufacturers indicated the capability of their cells to deliver specific energy of at least 180 Wh/kg or higher. Testing is being performed at the NASA Glenn Research Center to evaluate the performance of these cells under temperature, rate, and cycling conditions relevant to the ETDP goals for high energy cells. The cell-level specific energy goal for high energy technology is 180 Wh/kg at a C/10 rate and 0 C. The threshold value is 165 Wh/kg. The goal is to operate for at least 2000 cycles at 100 percent DOD with greater than 80 percent capacity retention. The Panasonic NCR18650 cells were able to deliver nearly 200 Wh/kg at the aforementioned conditions. The E-One Moli ICR18650J cells also met the specific energy goal by delivering 183 Wh/kg. Though both cells met the goal for specific energy, this testing was only one portion of the testing required to determine the suitability of commercial cells for the ETDP. The cells must also meet goals for cycle life and safety. The results of this characterization are summarized in this report.

Schneidegger, Brianne T.↗

Pilot and Controller Evaluations of Separation Function Allocation in Air Traffic Management

Two human-in-the-loop simulation experiments were conducted in coordinated fashion to investigate the allocation of separation assurance functions between ground and air and between humans and automation. The experiments modeled a mixed-operations concept in which aircraft receiving ground-based separation services shared the airspace with aircraft providing their own separation service (i.e., self-separation). Ground-based separation was provided by air traffic controllers without automation tools, with tools, or by ground-based automation with controllers in a managing role. Airborne self-separation was provided by airline pilots using self-separation automation enabled by airborne surveillance technology. The two experiments, one pilot-focused and the other controller-focused, addressed selected key issues of mixed operations, assuming the starting point of current-day operations and modeling an emergence of NextGen technologies and procedures. In the controller-focused experiment, the impact of mixed operations on controller performance was assessed at four stages of NextGen implementation. In the pilot-focused experiment, the limits to which pilots with automation tools could take full responsibility for separation from ground-controlled aircraft were tested. Results indicate that the presence of self-separating aircraft had little impact on the controllers' ability to provide separation services for ground-controlled aircraft. Overall performance was best in the most automated environment in which all aircraft were data communications equipped, ground-based separation was highly automated, and self-separating aircraft had access to trajectory intent information for all aircraft. In this environment, safe, efficient, and highly acceptable operations could be achieved for twice today's peak airspace throughput. In less automated environments, reduced trajectory intent exchange and manual air traffic control limited the safely achievable airspace throughput and negatively impacted the maneuver efficiency of self-separating aircraft through high-density airspace. In a test of scripted conflicts with ground-managed aircraft, flight crews of self-separating aircraft prevented separation loss in all conflicts with detection time greater than one minute. In debrief, pilots indicated a preference for at least five minute's alerting notice and trajectory intent information on all aircraft. When intent information on ground-managed aircraft was available, self-separating aircraft benefited from fewer conflict alerts and fewer required deviations from trajectory-based operations.

Wing, David↗

Evaluation of a high-resolution regional climate simulation for surface and hub-height wind climatology over North America

Assessing the availability of key wind resources requires augmenting observations to support the implementation of wind energy infrastructure. However, observations are limited, necessitating the development of high-resolution, long-term gridded datasets. This study presents a robust, dynamically downscaled climatological dataset, offering 20 years of hourly wind data at a 4 km spatial resolution across North America, and evaluates its performance against observations, including meteorological towers and automated surface-observing system (ASOS) stations, as well as coarse-resolution reanalysis data (the European Centre for Medium-Range Weather Forecasts (ECMWF) reanalysis version 5 (ERA5)). Results demonstrate that the downscaled high-resolution wind data outperform ERA5 in regions of complex terrain and coastal areas, with improved overlap coefficients for wind data distributions and reduced root mean square errors (RMSEs) for hub-height and near-surface diurnal wind patterns. The downscaled simulation also captures the synoptic drivers of seasonal wind direction patterns reasonably well, indicated by high wind rose similarity indices. This study also provides an analysis of interannual variability, utilizing the dataset's full 20-year period, and model uncertainty, generated by varying model initial conditions and physics parameterizations across 1-year ensemble members, which are key considerations for wind resource assessment in wind farm development.

17 WIND ENERGY↗

The Hubble Space Telescope

The Hubble Space Telescope was launched from the Kennedy Space Center on April 24, 1990. Its initial check-out indicates that all sub-systems of the satellite are working very well, with two key exceptions: The line-of-sight pointing is subject to occasional jitter apparently induced by thermal stresses in the solar arrays; this is expected to be overcome. The telescope mirrors are found to contain approximately 0.5 wave rms of spherical aberration which cannot be overcome by any controls on board the satellite. This defect will limit the scientific performance of the telescope in the short run. However, the aberration can be fully corrected in the optical designs of future replacement instruments, and the delivery schedules of these instruments are being accelerated.

Boggess, Albert↗

A Comprehensive System of Energy Intensity Indicators for the U.S.: Methods, Data and Key Trends

This report describes a comprehensive system of energy intensity indicators for the United States that has been developed for the Department of Energy’s Office of Energy Efficiency and Renewable Energy (EERE) over the past decade. This system of indicators is hierarchical in nature, beginning with detailed indexes of energy intensity for various sectors of the economy, which are ultimately aggregated to an overall energy intensity index for the economy as a whole. The aggregation of energy intensity indexes to higher levels in the hierarchy is performed with a version of the Log Mean Divisia index (LMDI) method. Based upon the data and methods in the system of indicators, the economy-wide energy intensity index shows a decline of about 16% in 2014 relative to a 1985 base year. Discussion of energy intensity indicators for each of the broad end-use sectors of the economy—residential, commercial, industrial, and transportation—is presented in the report. An analysis of recent changes in the efficiency of electricity generation in the U.S. is also included. A detailed appendix describes the data sources and methodology behind the energy intensity indicators for each sector.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A Comprehensive System of Energy Intensity Indicators for the U.S.: Methods, Data and Key Trends

This report describes a comprehensive system of energy intensity indicators for the United States that has been developed for the Department of Energy’s Office of Energy Efficiency and Renewable Energy (EERE) over the past decade. This system of indicators is hierarchical in nature, beginning with detailed indexes of energy intensity for various sectors of the economy, which are ultimately aggregated to an overall energy intensity index for the economy as a whole. The aggregation of energy intensity indexes to higher levels in the hierarchy is performed with a version of the Log Mean Divisia index (LMDI) method. Based upon the data and methods in the system of indicators, the economy-wide energy intensity index shows a decline of about 16% in 2014 relative to a 1985 base year. Discussion of energy intensity indicators for each of the broad end-use sectors of the economy—residential, commercial, industrial, and transportation—is presented in the report. An analysis of recent changes in the efficiency of electricity generation in the U.S. is also included. A detailed appendix describes the data sources and methodology behind the energy intensity indicators for each sector.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Scalability in SLA lattice through lattice orientation and hybrid frame and plate architectures

Lightweighting has been a key goal for engineers and designers, with lattice structures widely explored as the building blocks for structural components. Cellular structure-inspired lattice truss frame designs made of struts, have been extensively studied. All plate-based lattice designs have superior mechanical performance. Limits in scalability occur from formation of closed pockets limiting uv curing in processes like stereolithography (SLA). We examine hybrid frame and plate body-centered cubic-simply cubic (BCC-SC) lattices under compression. Unit cells and scaled up lattice exhibit an increase in yield stress and modulus with the addition of plates. The loading direction on the hybrid frame and plate unit cells affected the magnitude of improvement. Simulations and measurements indicated that the optimal lightweight lattice was determined to be when two plates were placed opposite each other with plates buttressing the struts, inhibiting buckling of the struts aligned with the loading direction. This lattice resulted in 63% improvement in specific modulus, a 137% improvement in specific yield point, and a 360% improvement in specific energy absorption (SEA) and the scaled up 4 × 4 × 4 scaled-up structures, showed a 107%, 148%, and 297% in specific modulus, specific yield point, and SEA, respectively A combined stretching-bending behavior was identified in optimal orientations reflecting the delayed buckling mechanism paired to a rising stress-strain curve past the elastic yield indicating bending resistance. The mass moment of inertia was found to be a key parameter correlating optimum orientation for the same number of plates added to the BCC-SC frame.

Mahan Ghosh↗

Examining CO 2 as an Additive for Solid Electrolyte Interphase Formation on Silicon Anodes

In this study, we demonstrate that the addition of CO 2 to a standard 1.0 M LiPF 6 3:7 wt% ethylene carbonate:ethyl methyl carbonate electrolyte results in the formation of a thinner insoluble solid electrolyte interphase (SEI) that is dominated by the presence of LiF. In contrast, cells without CO 2 result in a thicker insoluble SEI layer containing more organic constituents. The CO 2 is incorporated in the dimethyl carbonate soluble part of the SEI composed primarily of polymeric poly(ethylene oxide) (PEO) on the surface of a thin inorganic layer. This combination of properties from CO 2 addition provides an improved cycling performance through the reduction of irreversible side reactions, leading to higher coulombic efficiency. The results indicate that CO 2 incorporates into the SEI and plays a role similar to additives like fluorinated ethylene carbonate and vinylene carbonate with respect to polymeric components.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Uncertain role of clouds in shaping summertime atmosphere-sea ice connections in reanalyses and CMIP6 models

Downwelling longwave radiation (DLR) driven by the atmospheric and cloud conditions in the troposphere is suggested to be a dominant factor to determine the summertime net surface energy budget over the Arctic Ocean and thus plays a key role to shape the September sea ice. We use reanalyses and the self-organizing map (SOM) method to distinguish CMIP6 model performance in replicating the observed strong atmosphere-DLR connection. We find all models can reasonably simulate the linkage between key atmosphere variables and the clear sky DLR but behave differently in replicating the atmosphere-DLR connection due to cloud forcing. In ERA5 and strongly coupled models, tropospheric high pressure is associated with decreased clouds in the mid- and high-levels and increased clouds near the surface. This out-of-phase structure indicates that DLR cloud forcing is nearly neutral, making the clear sky DLR more important to bridge JJA circulation to late-summer sea ice. In MERRA-2 and weakly coupled models, tropospheric clouds display a vertically homogeneous reduction; the cloud DLR is thus strongly reduced due to the cooling effect, which partially cancels out the clear sky DLR and makes the total DLR less efficient to translate circulation forcing to sea ice. The differences of cloud vertical distribution in CMIP6 appear to be differentiated by circulation related relative humidity. Therefore, a better understanding of the discrepancy of different reanalyses and remote sensing products is critical to comprehensively evaluate simulated interactions among circulation, clouds, sea ice and energy budget at the surface in summer.

54 ENVIRONMENTAL SCIENCES↗

Long-Term field testing of the accuracy and HVAC energy savings potential of occupancy presence sensors in A Single-Family home

The energy-saving potential of occupancy-centric smart thermostats has been extensively explored in simulations but lacked field testing for energy savings quantification and sensor performance assessment in real buildings. This paper presents a long-term field study conducted in a single-family home in Texas, U.S. to evaluate the performance of occupancy-centric controls (OCC) of HVAC (heating, ventilation, and air-conditioning) system in terms of energy savings, sensor accuracy, and impact on electric peak demand. The test site was equipped with a commercial off-the-shelf (COTS) smart thermostat and multiple occupancy presence sensors for OCC implementation. Additionally, a sub-metering system was installed to monitor electricity consumption of various end-use equipment, including the HVAC system. A supplementary device was installed to track the ground-truth occupancy for the accuracy evaluation of the occupancy presence sensor. Scenarios of baseline and OCC controls were alternated weekly over the 20-month testing period. The results indicated an effective OCC execution, as evidenced by indoor temperature profiles. During the 2023 cooling season, OCC achieved total energy savings of 1,958 kWh, corresponding to a 17.6% energy savings ratio. Under certain conditions, daily HVAC energy savings reached as high as 17 kWh, with a savings ratio of 35%. Sensor performance showed an overall accuracy of 83.8%, a False Positive Rate (FPR) of 12.8%, and a False Negative Rate (FNR) of 47.4%. A key limitation was the sensor’s inability to detect stationary occupants during sleep, leading to a midnight FNR of nearly 100% and significantly compromising thermal comfort. Additionally, the implementation of OCC resulted in extended periods of high electricity demand on summer afternoons, affecting occupant’s thermal comfort and posing potential challenges to community-level grid operations if OCC were widely adopted. Furthermore, this study addresses a critical research gap by empirically investigating energy-saving potential and occupancy sensor performance in residential buildings. Through a comprehensive field-testing study, the research examines the interrelationship between sensor accuracy, energy savings, and thermal comfort, an area that has received limited attention in the current literature.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Lithium Ion Battery (LIB) Charger: Spacesuit Battery Charger Design with 2-Fault Tolerance to Catastrophic Hazards

Charger design that is 2-fault tolerant to catastrophic has been achieved for the Spacesuit Li-ion Battery with key features. Power supply control circuit and 2 microprocessors independently control against overcharge. 3 microprocessor control against undercharge (false positive: Go for EVA) conditions. 2 independent channels provide functional redundancy. Capable of charge balancing cell banks in series. Cell manufacturing and performance uniformity is excellent with both designs. Once a few outliers are removed, LV cells are slightly more uniform than MoliJ cells. If cell balance feature of charger is ever invoked, it will be an indication of a significant degradation issue, not a nominal condition.

Darcy, Eric↗