Search NASA⌕ Search

SEARCH · Search NASA

Results for “Lab Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Theory and operation of the real-time data acquisition system for the NASA-LaRC differential absorption lidar (DIAL)

The improvement of computer hardware and software of the NASA Multipurpose Differential Absorption Lidar (DIAL) system is documented. The NASA DIAL system has undergone development and experimental deployment at NASA/Langley Res. Center for the remote measurement of atmospheric trace gas concentrations from ground and aircraft platforms. A viable DIAL system was developed capable of remotely measuring O3 and H2O concentrations from an aircraft platform. The DIAL Data Acquisition System (DAS) has undergone a number of improvements also. Due to the participation of the DIAL in the Global Tropospheric Experiment, modifications and improvements of the system were tested and used both in the lab and in air. Therefore, this is an operational manual for the DIAL DAS.

Butler, Carolyn↗

Laboratory test methodology for evaluating the effects of electromagnetic disturbances on fault-tolerant control systems

Control systems for advanced aircraft, especially those with relaxed static stability, will be critical to flight and will, therefore, have very high reliability specifications which must be met for adverse as well as nominal operating conditions. Adverse conditions can result from electromagnetic disturbances caused by lightning, high energy radio frequency transmitters, and nuclear electromagnetic pulses. Tools and techniques must be developed to verify the integrity of the control system in adverse operating conditions. The most difficult and illusive perturbations to computer based control systems caused by an electromagnetic environment (EME) are functional error modes that involve no component damage. These error modes are collectively known as upset, can occur simultaneously in all of the channels of a redundant control system, and are software dependent. A methodology is presented for performing upset tests on a multichannel control system and considerations are discussed for the design of upset tests to be conducted in the lab on fault tolerant control systems operating in a closed loop with a simulated plant.

Belcastro, Celeste M.↗

Estimates of effects of residual acceleration on USML-1 experiments

The purpose of this study effort was to develop analytical models to describe the effects of residual accelerations on the experiments to be carried on the first U.S. Microgravity Lab mission (USML-1) and to test the accuracy of these models by comparing the pre-flight predicted effects with the post-flight measured effects. After surveying the experiments to be performed on USML-1, it became evident that the anticipated residual accelerations during the USML-1 mission were well below the threshold for most of the primary experiments and all of the secondary (Glovebox) experiments and that the only set of experiments that could provide quantifiable effects, and thus provide a definitive test of the analytical models, were the three melt growth experiments using the Bridgman-Stockbarger type Crystal Growth Furnace (CGF). This class of experiments is by far the most sensitive to low level quasi-steady accelerations that are unavoidable on space craft operating in low earth orbit. Because of this, they have been the drivers for the acceleration requirements imposed on the Space Station. Therefore, it is appropriate that the models on which these requirements are based are tested experimentally. Also, since solidification proceeds directionally over a long period of time, the solidified ingot provides a more or less continuous record of the effects from acceleration disturbances.

Naumann, Robert J.↗

Multilayer Piezoelectric Stack Actuator Characterization

Future NASA missions are increasingly seeking to use actuators for precision positioning to accuracies of the order of fractions of a nanometer. For this purpose, multilayer piezoelectric stacks are being considered as actuators for driving these precision mechanisms. In this study, sets of commercial PZT stacks were tested in various AC and DC conditions at both nominal and extreme temperatures and voltages. AC signal testing included impedance, capacitance and dielectric loss factor of each actuator as a function of the small-signal driving sinusoidal frequency, and the ambient temperature. DC signal testing includes leakage current and displacement as a function of the applied DC voltage. The applied DC voltage was increased to over eight times the manufacturers' specifications to investigate the correlation between leakage current and breakdown voltage. Resonance characterization as a function of temperature was done over a temperature range of -180C to +200C which generally exceeded the manufacturers' specifications. In order to study the lifetime performance of these stacks, five actuators from one manufacturer were driven by a 60volt, 2 kHz sine-wave for ten billion cycles. The tests were performed using a Lab-View controlled automated data acquisition system that monitored the waveform of the stack electrical current and voltage. The measurements included the displacement, impedance, capacitance and leakage current and the analysis of the experimental results will be presented.

active mirrors↗

Enzyme-Cascade Analysis of the Rio Tinto Subsurface Environment: A Biosensor Experiment

The Portable Test System (PTS), designed & developed by Charles Rivers Laboratories, Inc. (Charleston, SC) is a portable instrument that was designed to perform analysis of enzymatic assays related to rapid assessment of microbial contamination (Wainwright, 2003). The enzymatic cascade of Limulus Amebocyte Lysate (LAL) is known to be one of the most sensitive techniques available for microbial detection, enabling the PTS to be evaluated as a potential life detection instrument for in situ Astrobiology missions. In the summer of 2003 the system was tested as a part of the Mars Astrobiology Research and Technology Experiment (MARTE) ground truth science campaign in the Rio Tinto Analogue environment near Nerva, Spain. The preliminary results show that the PTS analysis correlates well with the contamination control tests and the more traditional lab-based biological assays performed during the MARTE field mission. Further work will be conducted on this research during a second field campaign in 2004 and a technology demonstration of a prototype instrument that includes autonomous sample preparation will occur in 2005.

McKay, David S.↗

Analysis of the March 30, 2011 Hail Event at Shuttle Launch Pad 39A

The Kennedy Space Center (KSC) Hail Monitor System, a joint effort of the NASA KSC Physics Lab and the KSC Engineering Services Contract (ESC) Applied Technology Lab, was first deployed for operational testing in the fall of 2006. Volunteers from the Community Collaborative Rain, Hail, and Snow Network (CoCoRaHS) in conjunction with Colorado State University have been instrumental in validation testing using duplicate hail monitor systems at sites in the hail prone high plains of Colorado. The KSC Hail Monitor System (HMS), consisting of three stations positioned approximately 500 ft from the launch pad and forming an approximate equilateral triangle, as shown in Figure 1, was first deployed to Pad 39B for support of STS-115. Two months later, the HMS was deployed to Pad 39A for support of STS-116. During support of STS-117 in late February 2007, an unusually intense (for Florida standards) hail event occurred in the immediate vicinity of the exposed space shuttle and launch pad. Hail data of this event was collected by the HMS and analyzed. Support of STS-118 revealed another important application of the hail monitor system. Ground Instrumentation personnel check the hail monitors daily when a vehicle is on the launch pad, with special attention after any storm suspected of containing hail. If no hail is recorded by the HMS, the vehicle and pad inspection team has no need to conduct a thorough inspection of the vehicle immediately following a storm. On the afternoon of July 13, 2007, hail on the ground was reported by observers at the Vertical Assembly Building (VAB) and Launch Control Center (LCC), about three miles west of Pad 39A, as well as at several other locations at KSC. The HMS showed no impact detections, indicating that the shuttle had not been damaged by any of the numerous hail events which occurred on that day.

Lane, John E.↗

Hail Disrometer Array for Launch Systems Support

Prior to launch, the space shuttle might be described as a very large thermos bottle containing substantial quantities of cryogenic fuels. Because thermal insulation is a critical design requirement, the external wall of the launch vehicle fuel tank is covered with an insulating foam layer. This foam is fragile and can be damaged by very minor impacts, such as that from small- to medium-size hail, which may go unnoticed. In May 1999, hail damage to the top of the External Tank (ET) of STS-96 required a rollback from the launch pad to the Vehicle Assembly Building (VAB) for repair of the insulating foam. Because of the potential for hail damage to the ET while exposed to the weather, a vigilant hail sentry system using impact transducers was developed as a hail damage warning system and to record and quantify hail events. The Kennedy Space Center (KSC) Hail Monitor System, a joint effort of the NASA and University Affiliated Spaceport Technology Development Contract (USTDC) Physics Labs, was first deployed for operational testing in the fall of 2006. Volunteers from the Community Collaborative Rain. Hail, and Snow Network (CoCoRaHS) in conjunction with Colorado State University were and continue to be active in testing duplicate hail monitor systems at sites in the hail prone high plains of Colorado. The KSC Hail Monitor System (HMS), consisting of three stations positioned approximately 500 ft from the launch pad and forming an approximate equilateral triangle (see Figure 1), was deployed to Pad 39B for support of STS-115. Two months later, the HMS was deployed to Pad 39A for support of STS-116. During support of STS-117 in late February 2007, an unusual hail event occurred in the immediate vicinity of the exposed space shuttle and launch pad. Hail data of this event was collected by the HMS and analyzed. Support of STS-118 revealed another important application of the hail monitor system. Ground Instrumentation personnel check the hail monitors daily when a vehicle is on the launch pad, with special attention after any storm suspected of containing hail. If no hail is recorded by the HMS, the vehicle and pad inspection team has no need to conduct a thorough inspection of the vehicle immediately following a storm. On the afternoon of July 13, 2007, hail on the ground was reported by observers at the VAB, about three miles west of Pad 39A, as well as at several other locations around Kennedy Space Center. The HMS showed no impact detections, indicating that the shuttle had not been damaged by any of the numerous hail events which occurred that day.

Lane, John E.↗

Cryo-Temp Data Logger

Biological experiments on the ISS are frequently frozen at ultra-low temperatures on orbit prior to return to Earth for analysis. Recording temperatures during the freezing process, and subsequent handling to the point of post-flight processing, can provide important information of sample integrity to the scientist. The MadgeTech Cryo-Temp Data Logger has been modified for space flight applications by the Payload Development Team at Kennedy Space Center. This ultra-low temperature data logger is rated for temperatures from -86 C to +35 C with 0.1 C resolution and +/-1 C accuracy, but has been successfully tested at Kennedy Space Centers Cryogenic Lab down to -100 C. The logger provides date and time stamped temperature recordings and can be set with logging intervals from 5 seconds up to 30 minutes using the MadgeTech Data Logger Software. Data can be recorded, depending on logging interval, for greater than 90 days. The Cryo-Temp Data logger will first be flown on Space X-12 in the BRIC-Petri Dish Fixation Unit (PDFU) canister hardware, recording temperature data for a Space Life and Physical Sciences (SLPS) flight experiment. The modified Cryo-Temp Data Logger is small in size (Figure 1) and is the ideal temperature monitoring solution for any application involving independent temperature data logging.

Logger↗

Progress on the Development of a Step Height Sensor for the BOLT Flight Vehicle

This presentation will summarize progress on the development of a step height sensor for the BOLT flight vehicle. Two methods have been proposed to measure the step size in this effort.The first method involves the application of miniaturized camera embedded in the flight vehicle that views the step through a rearward-facing port (shown in Fig. 1a inset). The second method involves the application of a linear fiber optic array bundle to measure the intensity of light reflected back from the aft body step (concept shown in Fig. 1b). Preliminary testing with the miniaturized camera has been performed in the lab and shows that displacements of ≤10 μm can be measured using this method. Final testing with both methods will be performed on the test stand shown in Fig. 1a. This test stand will include a fine adjustment vertical translation stage that will be used to adjust the step height in steps of 1-2 μm. A high-magnification imaging system will also be used to verify the step height. The miniaturized camera and linear fiber optic array bundle will be mounted in one of several port holes with varying degrees of inclination relative to the top surface in the opposing aft-section slab. BOLT flight vehicle details and information on the steps can be found in Ref. [1].

BOLT↗

Lab-on-a-Chip: From Astrobiology to the International Space Station

The continual and long-term habitation of enclosed environments, such as Antarctic stations, nuclear submarines and space stations, raises unique engineering, medical and operational challenges. There is no easy way out and no easy way to get supplies in. This situation elevates the importance of monitoring technology that can rapidly detect events within the habitat that affect crew safety such as fire, release of toxic chemicals and hazardous microorganisms. Traditional methods to monitor microorganisms on the International Space Station (ISS) have consisted of culturing samples for 3-5 days and eventual sample return to Earth. To augment these culture methods with new, rapid molecular techniques, we developed the Lab-on-a-Chip Application Development - Portable Test System (LOCAD-PTS). The system consists of a hand-held spectrophotometer, a series of interchangeable cartridges and a surface sampling/dilution kit that enables crew to collect samples and detect a range of biological molecules, all within 15 minutes. LOCAD-PTS was launched to the ISS aboard Space Shuttle Discovery in December 2006, where it was operated for the first time during March-May 2007. The surfaces of five separate sites in the US Lab and Node 1 of ISS were analyzed for endotoxin, using cartridges that employ the Limulus Amebocyte Lysate (LAL) assay; results of these tests will be presented. LOCAD-PTS will remain permanently onboard ISS with new cartridges scheduled for launch in February and October of 2008 for the detection of fungi (Beta-glucan) and Gram-positive bacteria (lipoteichoic acid), respectively.

Maule, Jake↗

Laboratory measurements of on-board subsystems

Good progress was achieved on the test bed for on-board subsystems for future satellites. The test bed is for subsystems developed previously. Four test setups were configured in the INTELSAT technical labs: (1) TDMA on-board modem; (2) multicarrier demultiplexer demodulator; (3) IBS/IDR baseband processor; and (4) baseband switch matrix. The first three series of tests are completed and the tests on the BSM are in progress. Descriptions of test setups and major test results are included; the format of the presentation is outlined.

Nuspl, P. P.↗

Telerobotics test bed for space structure assembly

A cooperative research on super long distance space telerobotics is now in progress both in Japan and USA. In this program. several key features will be tested, which can be applicable to the control of space robots as well as to terrestrial robots. Local (control) and remote (work) sites will be shared between Electrotechnical Lab (ETL) of MITI in Japan and Jet Propulsion Lab (JPL) in USA. The details of a test bed for this international program are discussed in this report.

Kitami, M.↗

Object Creation and Human Factors Evaluation for Virtual Environments

The main objective of this project is to provide test objects for simulated environments utilized by the recently established Army/NASA Virtual Innovations Lab (ANVIL) at Marshall Space Flight Center, Huntsville, Al. The objective of the ANVIL lab is to provide virtual reality (VR) models and environments and to provide visualization and manipulation methods for the purpose of training and testing. Visualization equipment used in the ANVIL lab includes head-mounted and boom-mounted immersive virtual reality display devices. Objects in the environment are manipulated using data glove, hand controller, or mouse. These simulated objects are solid or surfaced three dimensional models. They may be viewed or manipulated from any location within the environment and may be viewed on-screen or via immersive VR. The objects are created using various CAD modeling packages and are converted into the virtual environment using dVise. This enables the object or environment to be viewed from any angle or distance for training or testing purposes.

Lindsey, Patricia F.↗

Body Composition of Rats on NASA Rodent Foodbar Versus Purina Lab Chow

The objective of this study is to test the nutritional adequacy of the NASA Rodent Foodbar for long term use for rats. The Foodbar was tested on two rat strains, Sprague Dawley and Fischer 344. Rats were fed either Foodbar or the control diet, Purina Chow #5012. Body composition analysis was performed on a selected number of samples (n=6 for each gender and treatment group) as part of extensive testing of the Foodbar. Water, fat, ash, and protein (and their percentages) for both treatment groups were compared. Sprague Dawley Foodbar fed rats had a lower % protein than Chow fed rats (25.8% vs. 30.0%). In addition, Sprague Dawley females fed Foodbar had higher total fat (42.1g vs. 24.6g) and % fat (16.4% vs. 10.5%), but lower % water (51.3% vs. 54.8%) than Sprague Dawley females fed Chow. Fischer 344 Foodbar fed rats had a lower % water (47.4% vs. 49,3%) and total water (93.2g vs. 99.6g). In addition, Fischer 344 Foodbar males had higher % fat (17.0% vs. 13.8%) and total fat (43.0g vs. 34.7g). The data suggests that body composition of Foodbar fed rats tends to have lower water content but a higher fat content compared to controls, but not all results are the same for different strains and even different genders within the same strains. The data obtained here, in addition to other data, helps provide a better understanding of the nutritional adequacy of the Foodbar and whether the formula may need to be modified.

Yu, Diane Sau Mun↗

E-2C Loads Calibration in DFRC Flight Loads Lab

Objectives: a) Safely and efficiently perform structural load tests on NAVAIR E-2C aircraft to calibrate strain gage instrumentation installed by NAVAIR; b) Collect load test data and derive loads equations for use in NAVAIR flight tests; and c) Assist flight test team with use of loads equations measurements at PAX River.

Schuster, Lawrence S.↗

Lessons Learned from Particulate Characterization Laboratory Anomalies

The White Sands Test Facility chemistry laboratory provides quality control for cleanroom operations including cleanliness verification of aerospace hardware by particulate counts and non-volatile residue determinations, particulate counts for liquid hypergolic propellants, gaseous helium and nitrogen propellant pressurizing agents used for ground support equipment and flight test article valve actuation, gaseous oxygen primarily used for component testing, and deionized water for refurbished propellant hardware flushing. Cleanliness verification includes particulate counts and non-volatile residue determinations to industry standard, NASA, and program specifications and levels. Particulate counts are typically to customer-specified specifications and levels including JPR 5322.1H (2016) Levels 50 and 100, Orion (MPCV 70156. Revision H (2018)) Level 100, RPTSTD-8070-0001 Revision 3 (2022), and IEST-STD-CC1246E (2013) Levels 50 and 100. The laboratory issues high pressure filter holders containing membrane filters to test operations personnel, who collect samples by flowing the required volumes of fluid through the filter holder, and the filter holder is returned to the lab for counting. A passing particulate count is required before testing may proceed. Rapid data reduction and issuing of reports indicating a pass or fail of the particulate specification are required. Corrective action and resampling invariably occurs if a sample fails. Consequently, the laboratory must maintain the highest degree of reliability to facilitate quality data used to decide if testing may proceed. Experience and continual improvements have enabled reliability. However, anomalies attributed to lab processes and hardware including filter holders, membranes, and Petri dishes have been encountered. This paper presents a summary of problems, solutions, successes, and lessons learned from particle counting experience for over 35 years.

Lessons Learned↗