Search NASA⌕ Search

SEARCH · Search NASA

Results for “Laboratory procedures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Planning for Space Station Freedom laboratory payload integration

Space Station Freedom is being developed to support extensive missions involving microgravity research and applications. Requirements for on-orbit payload integration and the simultaneous payload integration of multiple mission increments will provide the stimulus to develop new streamlined integration procedures in order to take advantage of the increased capabilities offered by Freedom. The United States Laboratory and its user accommodations are described. The process of integrating users' experiments and equipment into the United States Laboratory and the Pressurized Logistics Modules is described. This process includes the strategic and tactical phases of Space Station utilization planning. The support that the Work Package 01 Utilization office will provide to the users and hardware developers, in the form of Experiment Integration Engineers, early accommodation assessments, and physical integration of experiment equipment, is described. Plans for integrated payload analytical integration are also described.

Willenberg, Harvey J.↗

Army Reactor Program Regulatory Bases: Supporting Army Regulation 50–7

This report describes the regulatory bases for the 2025 revision of Army Regulation (AR) 50–7 - Nuclear and Chemical Weapons and Materiel: Army Reactor Program and the new associated Department of the Army pamphlet (DA PAM) Army Reactor Program Procedures.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A study of TRIGLYCINE SULFATE (TGS) crystals from the International Microgravity Laboratory Mission (IML-1)

Preliminary evaluation of the data was made during the hologram processing procedure. A few representative holograms were selected and reconstructed in the HGS; photographs of sample particle images were made to illustrate the resolution of all three particle sizes. Based on these evaluations slight modifications were requested in the hologram processing procedure to optimize the hologram exposure in the vicinity of the crystal. Preliminary looks at the data showed that we are able to see and track all three sizes of particles throughout the chamber. Because of the vast amount of data available in the holograms, it was recommended that we produce a detailed data reduction plan with prioritization on the different types of data which can be extracted from the holograms.

Lal, R. B.↗

Curating NASA's Past, Present, and Future Extraterrestrial Sample Collections

As codified in NASA Policy Directive 7100.10F, the Astromaterials Acquisition and Curation Office at NASA Johnson Space Center (hereafter JSC Curation) is charged with curation of all extraterrestrial material under NASA control, including future NASA missions. JSC Curation curates all or part of nine astromaterial collections in seven clean room suites: (1) Apollo Samples (1969; ISO 6-7), (2) Luna Samples (from USSR; 1972; ISO 7), (3) Antarctic Meteorites (1976; ISO 7), (4) Cosmic Dust (1981; ISO 5), (5) Microparticle Impact Collection (formerly called Space Exposed Hardware; 1985; ISO 5), (6) Genesis Solar Wind Atoms (2004; ISO 4); (7) Stardust Comet Particles (2006; ISO 5), (8) Stardust Interstellar Particles (2006; ISO 5), (9) Hayabusa Asteroid Particles (from JAXA; 2010; ISO 5). In addition to the labs that house the samples, we have installed and maintained a wide variety of facilities and infrastructure required to support the clean-rooms: more than 10 different HEPA-filtered air-handling systems, ultrapure dry gaseous nitrogen systems, an ultrapure water system (UPW) and cleaning facilities to provide clean tools and equipment for the labs. We also have sample preparation facilities for making thin sections, microtome sections, and even focused ion-beam (FIB) sections to meet the research requirements of scientists. To ensure that we are keeping the samples as pristine as possible, we routinely monitor the cleanliness of our clean rooms and infrastructure systems. This monitoring includes: daily monitoring of the quality of our UPW, weekly airborne particle counts in the labs, monthly monitoring of the stable isotope composition of the gaseous N2 system, and annual measurements of inorganic or organic contamination in processing cabinets. We track within our databases the current and ever-changing characteristics of more than 250,000 individual samples across our various collections (including the 19,141 samples on loan to 433 Principal Investigators in 24 countries). The next sample return missions that NASA will participate in are Hayabusa2 and OSIRIS-REx (Origins Spectral Interpretation Resource Identification Security - Regolith Explorer). The designs for a new state-of-the-art suite of clean rooms to house these samples at JSC have been finalized. This includes separate ISO class 5 clean rooms to house each collection, a common ISO class 7 area for general use, an ISO class 7 microtome laboratory, and a separate thin section lab. Additionally, a new cleaning facility is being designed and procedures developed that will allow for enhanced cleaning of cabinets and tools in an inorganically, organically, and biologically clean manner. We are also designing a large multi-purpose Advanced Curation laboratory that will allow us to develop the techniques necessary to fully support the Hayabusa2 and OSIRIS-REx missions, as well as future possible sample return missions (e.g., Lunar Polar Volatiles, Mars, Comet Surface). A micro-CT (micro Computed Tomography) laboratory dedicated to the study of astromaterials has come online within JSC Curation, and we plan to add additional facilities that will enable non-destructive (or minimally-destructive) analyses of astromaterials in the near future (e.g., micro-XRF (micro X-Ray Fluorescence), confocal imaging Raman Spectroscopy). These facilities will be available to: (1) develop sample handling and storage techniques for future sample return missions, (2) be utilized by PET (Positron Emission Tomography) for future sample return missions, (3) for retroactive PET-style analyses of our existing collections, and (4) for periodic assessments of the existing sample collections.

Zeigler, Ryan A.↗

October 2024 Semiannual Composite Salt Waste Processing Facility (SWPF) Decontaminated Salt Solution (DSS) Toxicity Characteristic Leaching Procedure (TCLP) Results

The aqueous waste from the Salt Waste Processing Facility (SWPF) is sampled semiannually for transfers to the Saltstone Production Facility (SPF). Salt solution is treated at SPF and disposed of in the Saltstone Disposal Facility (SDF). Per request of customer, X-TTR-Z-00027, Revision 0, one SDF waste form (saltstone) sample was prepared in the Savannah River National Laboratory (SRNL) from the SWPF Decontaminated Salt Solution (DSS) Waste Acceptance Criteria (WAC) sample and Z-area premix material for the October 2024 semiannual Toxicity Characteristic Leaching Procedure (TCLP) sample. The sample contained 60:40 (by weight) of slag and fly ash (referred to as the “Cement-Free grout sample”). Results from the technical report support Task 2: ‘Grout Leaching Analyses’ of the Task Technical Request (TTR) prepared by Savannah River Mission Completion (SRMC). At 64 days cured, a sample of the SDF waste form was collected and shipped to a certified laboratory for analysis using the Toxicity Characteristic Leaching Procedure (TCLP). The October 2024 semiannual Cement-Free grout sample met the South Carolina (SC) Code of Regulations for Hazardous Waste Management Regulations (HWMR) 61-79.261.24 and 61-79.268.48 requirements for a non-hazardous waste form with respect to the Resource Conservation and Recovery Act (RCRA) metals and Underlying Hazardous Constituents (UHCs), and met the SPF WAC that was in effect at the time of the sample collection at SWPF.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

April 2024 Semiannual Composite Salt Waste Processing Facility (SWPF) Decontaminated Salt Solution (DSS) Toxicity Characteristic Leaching Procedure (TCLP) Results

The aqueous waste from the Salt Waste Processing Facility (SWPF) is sampled semiannually for transfers to the Saltstone Production Facility (SPF). Salt solution is treated at SPF and disposed of in the Saltstone Disposal Facility (SDF). Per request of customer, X-TTR-Z-00027, Revision 0, one SDF waste form (saltstone) sample was prepared in the Savannah River National Laboratory (SRNL) from the SWPF Decontaminated Salt Solution (DSS) Waste Acceptance Criteria (WAC) sample and Z-area premix material for the April 2024 semiannual Toxicity Characteristic Leaching Procedure (TCLP) sample. The sample contained 60:40 (by weight) of slag and fly ash (referred to as the “Cement-Free grout sample”). Results from the technical report support Task 2: ‘Grout Leaching Analyses’ of the Task Technical Request (TTR) prepared by Savannah River Mission Completion (SRMC). After at least 28 days cured, a sample of the SDF waste form was collected and shipped to a certified laboratory for analysis using the Toxicity Characteristic Leaching Procedure (TCLP). The April 2024 semiannual Cement-Free grout sample met the South Carolina (SC) Code of Regulations for Hazardous Waste Management Regulations (HWMR) 61-79.261.24 and 61-79.268.48 requirements for a non-hazardous waste form with respect to the Resource Conservation and Recovery Act (RCRA) metals and Underlying Hazardous Constituents (UHCs), and met the SPF WAC that was in effect at the time of the tank sampling.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Techniques for Solution- Assisted Optical Contacting

A document discusses a solution-assisted contacting technique for optical contacting. An optic of surface flatness Lambda/20 was successfully contacted with one of moderate surface quality, or Lambda/4. Optics used were both ultra-low expansion (ULE) glass (Lambda/4 and Lambda/20) and fused silica (Lambda/20). A stainless steel template of the intended interferometer layout was designed and constructed with three contact points per optic. The contact points were all on a common side of the template. The entire contacting jig was tilted at about 30 . Thus, when the isopropanol was applied, each optic slid due to gravity, resting on the contact points. All of the contacting was performed in a relatively dusty laboratory. A number of successful contacts were achieved where up to two or three visible pieces of dust could be seen. These were clearly visible due to refraction patterns between the optic and bench. On a number of optics, the final step of dropping isopropyl between the surfaces was repeated until a successful contact was achieved. The new procedures realized in this work represent a simplification for optical contacting in the laboratory. They will both save time and money spent during the contacting process, and research and development phases. The techniques outlined are suitable for laboratory experiments, research, and initial development stages.

DeVine, Glenn↗

Enumeration and Fluorescence In Situ Hybridization of Microbial Bioburden on Cleanroom Surfaces

Introduction: Microorganisms are everywhere on Earth, even in the cleanest of places. Spacecraft assembly cleanrooms can harbor low levels of living and dead microbial cells (e.g., [1,2]), and cleanroom bioburden can also include organic molecules from industrial sources and in situ biomass. Life detection missions require careful attention to avoid contaminants that can be easily convoluted with analytical targets. We are evaluating epifluorescent microscopy and fluorescence in situ hybridization (FISH) as methods to complement organic contamination detection techniques. Epifluorescent cell counting offers an accurate and cost-effective way to quantify low levels of surface biomass. FISH could allow for the identification of residual organisms, and can be targeted to detect active populations of specific organisms such as bacteria known to resist cleaning procedures. This effort is part of a larger study that is concentrated on characterizing the surface and airborne molecular organic contamination background in Johnson Space Center (JSC) Astromaterials curation laboratories and Goddard Space Flight Center (GSFC) spacecraft assembly rooms, and understanding contaminants in the context of cleaning procedures and residual bioburden. Methods: Samples were collected by swabbing surfaces in ISO 5 and ISO 7 equivalent cleanrooms at JSC. Swabs for FISH were fixed in 4% paraformaldehyde (PFA) for 3 hours and then stored in 1:1 ethanol:PBS, while swabs for cell counting were stored in 4% PFA until analysis to avoid any cell loss during centrifugation that could impact quantification of very low biomass samples. Cell counting was performed with SYBR Gold as in [3], but adapted for very low biomass. FISH was performed as in [4], using DAPI as a counterstain for all DNA-containing cells. Negative controls included wells with no probe applied, to test for natural fluorescence, as well as the nonsense probe NONEUB (reverse complement of EUB338) to evaluate non-specific probe binding. Results and Discussion: Cleanroom surfaces had 102-103 cells cm-2. The extremely low biomass of these samples was challenging for enumeration, and required careful and routine use of “field” and laboratory blanks. FISH was performed with the general archaeal and bacterial probes ARCH915 and EUB338 (EUBMIX, [4]), probe GAMBET ([4]), and PSE227, which targets the genus Pseudomonas [5]). The latter two probes were selected because Pseudomonas spp. and other Gammaproteobacteria have not been isolated from cleanroom surfaces but do appear frequently in rRNA gene libraries from these surfaces. While some active bacteria were identified (Fig. 1c), most cells detectable by DAPI did not have a strong or any fluorescent signal (e.g., Fig. 1d), indicating that the vast majority of cells are dead or inactive. This suggests that cleaning protocols are effective at inactivating microbial contaminants, but that dead or inactive cells can remain on surfaces. Cells were often clumped in a weakly autofluorescent matrix, possibly biofilm material (Fig. 1c,d). We also observed other particulate material that was collected by the swabs, including apparent textile fibers (Fig. 1b). Our results are consistent with other studies that show that the bioburden present in clean rooms includes active, dormant, and dead cells. We will discuss how FISH and epifluorescent cell counting could be applied in planetary protection protocols, including the advantages and disadvantages of FISH and cell counting for routine use, as well as different possible applications for more specialized FISH procedures. References: [1] Moissl-Eichinger et al. (2015) Sci Rep, 5, 9156 [2] Hendrickson et al. (2021) Microbiome, 9, 238 [3] Jones et al. (2017) Appl Environ Microbiol, 83, e00909-17 [4] Jones et al. (2015) Appl Environ Microbiol, 81, 1242-1250. [5] Watt et al. (2006) Environ Microbiol, 8, 871-884

C J Huff↗

TA-16-306: A Plastics Components Development Facility (Volumes 1 & 2)

The U.S. Department of Energy (DOE), National Nuclear Security Administration (NNSA), Los Alamos Field Office (Field Office), has prepared final documentation for the resolution of adverse effects to Building 306 in Technical Area (TA) 16 at Los Alamos National Laboratory (LANL or the Laboratory). This documentation is being submitted to the New Mexico State Historic Preservation Officer (SHPO). TA-16-306 was determined eligible for listing in the National Register of Historic Places (Register) in 1995 in the report, TA-16 Heating System Replacement (LA-CP-95-0180). TA-16- 306 was identified as an excess property to be decontaminated, decommissioned, and demolished by the LANL Footprint Reduction Program in fiscal year 2021, an adverse effect to Register eligible building 16-306 requiring mitigation. To bring a resolution to the adverse effects to Building TA-16-306, the Field Office initiated consultation with the SHPO on December 4, 2017. The New Mexico Historic Preservation Division concurred with the mitigation actions outlined in the Programmatic Agreement among the U.S. Department of Energy, National Nuclear Security Administration, Los Alamos Field Office, the New Mexico State Historic Preservation Office, and the Advisory Council on Historic Preservation Concerning Management of Historic Properties of Los Alamos National Laboratory, Los Alamos, New Mexico (PA) in correspondence dated January 30, 2018. The PA states in Appendix D.2.A that adverse effects to Register-eligible buildings and structures will be resolved according to the procedures defined in A Plan for the Management of the Cultural Heritage at Los Alamos National Laboratory, New Mexico (CRMP) (LA-UR-19-21590, formerly LA-UR-15-27624) and within the PA itself. Volume 2 contains a collection of photos of building TA-16-306 with index.

42 ENGINEERING↗

NASA Glenn's Acoustical Testing Laboratory Awarded Accreditation by the National Voluntary Laboratory Accreditation Program

NASA Glenn Research Center's Acoustical Testing Laboratory (ATL) provides a comprehensive array of acoustical testing services, including sound pressure level, sound intensity level, and sound-power-level testing per International Standards Organization (ISO)1 3744. Since its establishment in September 2000, the ATL has provided acoustic emission testing and noise control services for a variety of customers, particularly microgravity space flight hardware that must meet International Space Station acoustic emission requirements. The ATL consists of a 23- by 27- by 20-ft (height) convertible hemi/anechoic test chamber and a separate sound-attenuating test support enclosure. The ATL employs a personal-computer-based data acquisition system that provides up to 26 channels of simultaneous data acquisition with real-time analysis (ref. 4). Specialized diagnostic tools, including a scanning sound-intensity system, allow the ATL's technical staff to support its clients' aggressive low-noise design efforts to meet the space station's acoustic emission requirement. From its inception, the ATL has pursued the goal of developing a comprehensive ISO 17025-compliant quality program that would incorporate Glenn's existing ISO 9000 quality system policies as well as ATL-specific technical policies and procedures. In March 2003, the ATL quality program was awarded accreditation by the National Voluntary Laboratory Accreditation Program (NVLAP) for sound-power-level testing in accordance with ISO 3744. The NVLAP program is administered by the National Institutes of Standards and Technology (NIST) of the U.S. Department of Commerce and provides third-party accreditation for testing and calibration laboratories. There are currently 24 NVLAP-accredited acoustical testing laboratories in the United States. NVLAP accreditation covering one or more specific testing procedures conducted in accordance with established test standards is awarded upon successful completion of an intensive onsite assessment that includes proficiency testing and documentation review. The ATL NVLAP accreditation currently applies specifically to its ISO 3744 soundpower- level determination procedure (see the photograph) and supporting ISO 17025 quality system, although all ATL operations are conducted in accordance with its quality system. The ATL staff is currently developing additional procedures to adapt this quality system to the testing of space flight hardware in accordance with International Space Station acoustic emission requirements.<

Akers, James C.↗

A design procedure for the phase-controlled parallel-loaded resonant inverter

High-frequency-link power conversion and distribution based on a resonant inverter (RI) has been recently proposed. The design of several topologies is reviewed, and a simple approximate design procedure is developed for the phase-controlled parallel-loaded RI. This design procedure seeks to ensure the benefits of resonant conversion and is verified by data from a laboratory 2.5 kVA, 20-kHz converter. A simple phasor analysis is introduced as a useful approximation for design purposes. The load is considered to be a linear impedance (or an ac current sink). The design procedure is verified using a 2.5-kVA 20-kHz RI. Also obtained are predictable worst-case ratings for each component of the resonant tank circuit and the inverter switches. For a given load VA requirement, below-resonance operation is found to result in a significantly lower tank VA requirement. Under transient conditions such as load short-circuit, a reversal of the expected commutation sequence is possible.

King, Roger J.↗

Y-12 Groundwater Protection Program Groundwater and Surface Water Sampling and Analysis Plan (CY2020)

This plan provides a description of the groundwater and surface water quality monitoring activities planned for calendar year (CY) 2020 at the U.S. Department of Energy Y-12 National Security Complex (Y-12) that will be managed by the Y-12 Groundwater Protection Program (GWPP). The following sections of this report provide details regarding the CY 2020 groundwater and surface water monitoring activities. Section 2 describes the monitoring locations in each regime and the processes used to select the sampling locations. A description of the field measurements and laboratory analytes is provided in Section 3. Sample collection methods and procedures are described in Section 4, and Section 5 lists the documents cited for more detailed operational and technical information.

54 ENVIRONMENTAL SCIENCES↗

Y-12 Groundwater Protection Program Groundwater and Surface Water Sampling and Analysis Plan for Calendar Year 2022

This plan provides a description of the groundwater and surface water quality monitoring activities planned for calendar year (CY) 2022 at the U.S. Department of Energy Y-12 National Security Complex (Y-12) that will be managed by the Y-12 Groundwater Protection Program (GWPP). Groundwater and surface water monitoring will be performed in three hydrogeologic regimes at Y-12: the Bear Creek Hydrogeologic Regime (Bear Creek Regime), the Upper East Fork Poplar Creek Hydrogeologic Regime (East Fork Regime), and the Chestnut Ridge Hydrogeologic Regime (Chestnut Ridge Regime). The Bear Creek and East Fork regimes are located in Bear Creek Valley and the Chestnut Ridge Regime is located south of Y-12. Additional surface water monitoring will be performed north of Pine Ridge along the boundary of the Oak Ridge Reservation. The following sections of this report provide details regarding the CY 2022 groundwater and surface water monitoring activities. Section 2 describes the monitoring locations in each regime and the processes used to select the sampling locations. A description of the field measurements and laboratory analytes is provided in Section 3. Sample collection methods and procedures are described in Section 4, and Section 5 lists the documents cited for more detailed operational and technical information.

54 ENVIRONMENTAL SCIENCES↗

Status of availability of Mariner 9 (1971-051A) TV picture data

Request procedures are described for Mariner 9 TV picture data. Image processing laboratory, user's guides, mosaics, catalogues, and microfiches are briefly discussed. Samples of the limb picture microfiche index and catalogue are presented.

Source record↗

Development of flightweight static face seals for 75.84 MPa /11 000 psi/ pressure and cryogenic temperatures

The development of a static seal configuration to meet the lightweight low-leakage requirements of the Space Shuttle Main Engine (pressure carrying capability of up to 75.84 MPa) is discussed. The design features, fabrication methods, lab testing, and performance of seal are examined. Flange and bolt details of the joint assembly are considered with attention to an ultrasonic technique for measuring preload in the bolts. Methods used for leak testing in the laboratory and in the field are described; the practicality of the procedures is considered. Attention is directed to hydrogen-environment embrittlement and its influence on seal and joint design.

Daniels, C. M.↗

Electric vehicle test report Cutler-Hammer Corvette

Vehicles were characterized for the state of the art assessment of electric vehicles. The vehicle evaluated was a Chevrolet Corvette converted to electric operation. The original internal combustion engine was replaced by an electric traction motor. Eighteen batteries supplied the electrical energy. A controller, an onboard battery charger, and several dashboard instruments completed the conversion. The emphasis was on the electrical portion of the drive train, although some analysis and discussion of the mechanical elements are included. Tests were conducted both on the road (actually a mile long runway) and in a chassis dynamometer equipped laboratory. The majority of the tests performed were according to SAE Procedure J227a and included maximum effort accelerations, constant speed range, and cyclic range. Some tests that are not a part of the SAE Procedure J227a are described and the analysis of the data from all tests is discussed.

Source record↗

Methods of training the graduate level and professional geologist in remote sensing technology

Requirements for a basic course in remote sensing to accommodate the needs of the graduate level and professional geologist are described. The course should stress the general topics of basic remote sensing theory, the theory and data types relating to different remote sensing systems, an introduction to the basic concepts of computer image processing and analysis, the characteristics of different data types, the development of methods for geological interpretations, the integration of all scales and data types of remote sensing in a given study, the integration of other data bases (geophysical and geochemical) into a remote sensing study, and geological remote sensing applications. The laboratories should stress hands on experience to reinforce the concepts and procedures presented in the lecture. The geologist should then be encouraged to pursue a second course in computer image processing and analysis of remotely sensed data.

Kolm, K. E.↗