Search NASA⌕ Search

SEARCH · Search NASA

Results for “Laser Calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Radiometric Calibration of A Non-Imaging Airborne Spectrometer To Measure the Greenland Ice Sheet Surface

Methods to radiometrically calibrate a non-imaging airborne visible-to-shortwave infrared (VSWIR) spectrometer to measure the Greenland ice sheet surface are presented. Airborne VSWIR measurement performance for bright Greenland ice and dark bare rock/soil targets is compared against the MODerate resolution atmospheric TRANsmission (MODTRAN ® ) radiative transfer code (version 6.0), and a coincident Landsat 8 Operational Land Imager (OLI) acquisition on 29 July 2015 during an in-flight radiometric calibration experiment. Airborne remote sensing flights were carried out in northwestern Greenland in preparation for the Ice, Cloud, and land Elevation Satellite 2 (ICESat-2) laser altimeter mission. A total of nine science flights were conducted over the Greenland ice sheet, sea ice, and open-ocean water. The campaign's primary purpose was to correlate green laser pulse penetration into snow and ice with spectroscopic-derived surface properties. An experimental airborne instrument configuration that included a nadir-viewing (looking downward at the surface) non-imaging Analytical Spectral Devices (ASD) Inc. spectrometer that measured upwelling VSWIR (0.35 to 2.5 µm) spectral radiance (Wm −2 sr −1 µm −1 ) in the two-color Slope Imaging Multi-polarization Photon-Counting Lidar's (SIMPL) ground instantaneous field of view, and a zenith-viewing (looking upward at the sky) ASD spectrometer that measured VSWIR spectral irradiance (W m −2 nm −1 ) was flown. National Institute of Standards and Technology (NIST) traceable radiometric calibration procedures for laboratory, in-flight, and field environments are described in detail to achieve a targeted VSWIR measurement requirement of within 5 % to support calibration/validation efforts and remote sensing algorithm development. Our MODTRAN predictions for the 29 July flight line over dark and bright targets indicate that the airborne nadir-viewing spectrometer spectral radiance measurement uncertainty was between 0.6 % and 4.7 % for VSWIR wavelengths (0.4 to 2.0 µm) with atmospheric transmittance greater than 80 %. MODTRAN predictions for Landsat 8 OLI relative spectral response functions suggest that OLI is measuring 6 % to 16 % more top-of-atmosphere (TOA) spectral radiance from the Greenland ice sheet surface than was predicted using apparent reflectance spectra from the nadir-viewing spectrometer. While more investigation is required to convert airborne VSWIR spectral radiance into atmospherically corrected airborne surface reflectance, it is expected that airborne science flight data products will contribute to spectroscopic determination of Greenland ice sheet surface optical properties to improve understanding of their potential influence on ICESat-2 measurements.

Christopher J. Crawford↗

A Laser-Induced Fluorescence Instrument for Aircraft Measurements of Sulfur Dioxide in the Upper Troposphere and Lower Stratosphere

This work describes the development and testing of a new instrument for in situ measurements of sulfur dioxide (SO2) on airborne platforms in the upper troposphere and lower stratosphere (UTLS). The instrument is based on the laser-induced fluorescence technique and uses the fifth harmonic of a tunable fiber-amplified semiconductor diode laser system at 1084.5 nm to excite SO2 at 216.9 nm. Sensitivity and background checks are achieved in flight by additions of SO2 calibration gas and zero air, respectively. Aircraft demonstration was performed during the NASA Volcano Plume Investigation Readiness and Gas-Phase and Aerosol Sulfur (VIRGAS) experiment, which was a series of flights using the NASA WB-57F during October 2015 based at Ellington Field and Harlingen, Texas. During these flights, the instrument successfully measured SO2 in the UTLS at background (non-volcanic) conditions with a precision of 2 ppt at 10 s and an overall uncertainty determined primarily by instrument drifts of +/- (16% + 0.9 ppt).

tunable fiber-amplified semiconductor diode laser ↗

Real-time tracking of objects for space applications using a laser range scanner

Real-time tracking of multiple targets and three dimensional object features was demonstrated using a laser range scanner. The prototype was immune to ambient illumination and sun interference. Tracking error feedback was simultaneously obtained from individual targets, global predicted target position, and the human operator. A more complete study of calibration parameters and temperature variations on the scanner is needed to determine the exact performance of the sensor. Lissajous patterns used in three-dimensional real-time tracking prove helpful given their high resolution. The photogrammetry-based Advanced Space Vision System (ASVS) is discussed in combination with the laser range scanner.

Blais, F.↗

Calibration and Validation of the SHERLOC Instrument Operating in Jezero Crater, Mars

The Scanning Habitable Environments with Raman and Luminescence for Organics and Chemistry (SHERLOC) is an instrument onboard the Mars 2020 Perseverance rover. It consists of a spectrometer that measures deep ultraviolet (DUV) resonance Raman and native fluorescence photons generated through surface interactions with a 248.6 nm pulsed laser. Two microscopic imagers, the Autofocus Context Imager (ACI) and the Wide-Angle Topographic Sensor for Operations and eNgineering (WATSON), provide high-resolution context images of SHERLOC targets. The ACI is co-boresighted with the spectrometer. To ensure proper calibration, the SHERLOC calibration target (SCT) is mounted on the front of the rover and consists of ten different materials. The SCT was designed, fabricated, assembled, and tested by Jacobs Technology, Inc., and NASA Johnson Space Center. The dimensions of the calibration target housing are 150 x 89 x 33 mm and it weighs ~437 g. The ten targets are arranged in two rows; the first six are hard targets (AlGaN for Raman and fluorescence, diffuse transmission target, a slice of the SaU008 Mars meteorite, an intensity maze, and polycarbonate over geocache coin) and the remaining four are soft-goods targets (Vectran, Ortho-Fabric, Teflon, and nGimat-coated Teflon). The hard targets calibrate the spectrometer’s Raman and fluorescence spectral accuracy, ambient light reflection, and Raman response curve, while the soft-goods targets are spacesuit materials that function as human exploration targets, some of which are also used for spectral calibration. SHERLOC also has an internal calibration target consisting of AlGaN on sapphire (275 nm) located inside the ACI opaque dust cover to ensure proper instrument functioning between calibration target analyses. Initial SHERLOC, ACI, and WATSON calibration and validation on Mars was performed using the internal calibration target on sols 59, 83, 98, and 141; WATSON imaging of the SCT on sols 26 and 62, and SHERLOC spectroscopy and ACI imaging of the SCT on sol 59. These early data provide initial insights into instrument performance and the stability and degradation of the calibration target materials relative to the Martian surface and dust environment. Early observations also have implications for future astronaut spacesuit materials.

Trevor G Graff↗

High-precision gravimetric survey in support of lunar laser ranging at Haleakala, Maui, 1976 - 1978

The planning, observations and adjustment of high-precision gravity survey networks established on the islands of Maui and Oahu as part of the geodetic-geophysical program in support of lunar laser ranging at Haleakala, Maui, Hawaii are described. The gravity survey networks include 43 independently measured gravity differences along the gravity calibration line from Kahului Airport to the summit of Mt. Haleakala, together with some key points close to tidal gauges on Maui, and 40 gravity differences within metropolitan Honolulu. The results of the 1976-1978 survey are compared with surveys made in 1961 and in 1964-1965. All final gravity values are given in the system of the international gravity standardization net 1971 (IGSN 71); values are obtained by subtracting 14.57 mgal from the Potsdam value at the gravity base station at the Hickam Air Force Base, Honolulu.

Schenck, B. E.↗

LOWCAL Ground Receiver: PMT Characterization Procedure and Results

This paper is part of a series of papers for a research project at New Mexico State University. The project is referred to as LOWCAL or Lightweight optical wavelength communications without a laser in space. While some of the material presented is specific to the LOWCAL project, the general procedure for characterization and calibration of a photomultiplier tube is presented.

MacCannell, John, Alexander↗

Lamb wave defect detection and evaluation using a fully non-contact laser system

Traditional Lamb wave structural health monitoring (SHM)/nondestructive evaluation (NDE) system employs contact type transducers such as PZT, ultrasonic transducers, and optical fibers. In application, transducer attachment and maintenance can be time and labor consuming. In addition, the use of couplant and adhesives can introduce additional materials on structures, and the interface coupling is often not well understood. To overcome these limitations, we proposed a fully non-contact NDE system by employing pulsed laser (PL) for Lamb wave actuation and scanning laser Doppler vibrometer (SLDV) for Lamb wave sensing. The proposed system is implemented on aluminum plates. The PL Lamb wave excitation is calibrated, and the optimal parameters are obtained. Lamb wave modes are then characterized through 1D wavefield analysis. With the calibrated and characterized system, defect detection and evaluation are achieved on aluminum plates with simulated defects (surfaced-bonded quartz rod, and machine milled crack) through 1D and 2D inspection in both time-space and frequency-wavenumber domains.

Ma, Zhaoyun↗

Pulsed multiwavelength laser ranging system

A pulsed multiwavelength laser ranging system for measuring atmospheric delay was built and tested, and its theoretical performance limits were calculated. The system uses a dye modelocked ND:YAG laser, which transmits 70 psec wide pulses simultaneously at 1064, 532, and 355 nm. The differential delay of the 1064 and 355 nm pulses is measured by a specially calibrated waveform digitizer to estimate the dry atmospheric delay. The delay time of the 532 nm pulse is used to measure the target distance. Static crossed field photomultipliers are used as detectors for all wavelengths. Theoretical analysis shows that path curvature and atmospheric turbulence are fundamental limits to the ranging accuracy of both single and multicolor systems operating over horizontal paths. For two color systems, an additional error is caused by the uncertainty in the path averaged water vapor. The standard deviation of the multicolor instrument's timing measurements is directly proportional to the laser pulse width plus photomultiplier jitter divided by the square root of the received photoelectron number. The prototype system's maximum range is km, which is limited by atmospheric and system transmission losses at 355 nm. System signal detection and false alarm calculations are also presented.

Abshire, J. B.↗

System enables more complete calibrations of dynamic-pressure transducers

Absolute pressure calibration system using a Michelson interferometer calibrates phase characteristics and pressure sensitivities of the transducers that monitor acoustic or aerodynamic pressure fields. The interferometer uses a helium-neon laser light source and interchangeable acoustic signal generators to produce acoustic waves.

Pernet, D. F.↗

Engineering a laser remote sensor for atmospheric pressure and temperature

A system for the remote sensing of atmospheric pressure and temperature is described. Resonant lines in the 7600 Angstrom oxygen A band region are used and an organic dye laser beam is tuned to measure line absorption changes with temperature or pressure. A reference beam outside this band is also transmitted for calibration. Using lidar techniques, profiling of these parameters with altitude can be accomplished.

Kalshoven, J. E., Jr.↗

Prototype microprocessor controller

A microcomputer controller for STDN antennas was developed. The microcomputer technology reduces the system's physical size by the implementation in firmware of functions. The reduction in the number of components increases system reliability and similar benefit is derived when a graphic video display is substituted for several control and indicator panels. A substantial reduction in the number of cables, connectors, and mechanical switches is achieved. The microcomputer based system is programmed to perform calibration and diagnostics, to update the satellite orbital vector, and to communicate with other network systems. The design is applicable to antennas and lasers.

Zarur, J.↗

Compact X-Ray And Extreme-Ultraviolet Monochromator

Monochromator for x-ray and extreme-ultraviolet radiation provides higher spectral resolution than achieved with thin-metal-foil broad-band-pass filters. Uses Bragg reflection to band-pass-filter radiation from high-intensity, broad-spectrum source. Operates over much broader x-ray and extreme-ultraviolet spectrum than devices based upon natural crystals. Intended to filter continuum radiation from sources like synchrotrons, laser plasma sources, free-electron lasers, and wigglers to produce monochromatic beams for testing and analysis of x-ray and extreme-ultraviolet telescopes and microscopes, for calibration of photographic films and detectors, for biological and biomedical research, for x-ray lithography, for processing of materials, and for research in properties of materials.

Hoover, Richard B.↗

Optical attenuation mechanism upgrades, MOBLAS, and TLRS systems

This poster presentation describes the Optical Attenuation Mechanism (OAM) Upgrades to the MOBLAS and TLRS Crustal Dynamics Satellite Laser Ranging (CDSLR) systems. The upgrades were for the purposes of preparing these systems to laser range to the TOPEX/POSEIDON spacecraft when it will be launched in the summer of 1992. The OAM permits the laser receiver to operate over the expected large signal dynamic range from TOPEX/POSEIDON and it reduces the number of pre- and post-calibrations for each satellite during multi-satellite tracking operations. It further simplifies the calibration bias corrections that had been made due to the pass-to-pass variation of the photomultiplier supply voltage and the transmit filter glass thickness. The upgrade incorporated improvements to the optical alignment capability of each CDSLR system through the addition of a CCD camera into the MOBLAS receive telescope and an alignment telescope onto the TLRS optical table. The OAM is stepper motor and microprocessor based; and the system can be controlled either manually by a control switch panel or computer controlled via an EIA RS-232C serial interface. The OAM has a neutral density (ND) range of 0.0 to 4.0 and the positioning is absolute referenced in steps of 0.1 ND. Both the fixed transmit filter and the daylight filter are solenoid actuated with digital inputs and outputs to and from the OAM microprocessor. During automated operation, the operator has the option to overide the remote control and control the OAM system via a local control switch panel.

Eichinger, Richard↗

VCL Laser Altimeter Surface Return Expected Geolocation Performance

The Vegetation Canopy Lidar (VCL) mission, expected to launch in the spring of 2002, will carry a unique Multi-Beam Laser Altimeter (MBLA) instrument designed to observe vegetative canopy structure for a nominal mission duration of 2 years. The VCL MBLA is a three-beam instrument where each laser is capable of producing returns with 30-m along-track spacing and 25-m-diameter footprints. Identifying the precise location of the point on the Earth's surface from which the laser energy reflects is a critical issue in the validation and application of the data. The resultant geolocation accuracy is dependent on the performance of many components of the VCL system including: laser pulse round trip travel time observation to surface, navigation tracking data, attitude determination system data, timing, laser pointing and body orientation stability, knowledge of instrument and navigation tracking point positions, media and geophysical corrections. Additionally, it is critical to calibrate on-orbit instrument parameters including pointing and range corrections. The geolocation and calibration methodology and algorithms will be summarized. A detailed geolocation error analysis identifying the contributions from each system component, along with the resultant expected geolocation accuracy, will be presented. A brief discussion of the operational geolocation process will also be presented. Science and data validation implications from geolocation performance will be summarized.

Luthcke, S. B.↗

Enhanced Video-Oculography System

A previously developed video-oculography system has been enhanced for use in measuring vestibulo-ocular reflexes of a human subject in a centrifuge, motor vehicle, or other setting. The system as previously developed included a lightweight digital video camera mounted on goggles. The left eye was illuminated by an infrared light-emitting diode via a dichroic mirror, and the camera captured images of the left eye in infrared light. To extract eye-movement data, the digitized video images were processed by software running in a laptop computer. Eye movements were calibrated by having the subject view a target pattern, fixed with respect to the subject s head, generated by a goggle-mounted laser with a diffraction grating. The system as enhanced includes a second camera for imaging the scene from the subject s perspective, and two inertial measurement units (IMUs) for measuring linear accelerations and rates of rotation for computing head movements. One IMU is mounted on the goggles, the other on the centrifuge or vehicle frame. All eye-movement and head-motion data are time-stamped. In addition, the subject s point of regard is superimposed on each scene image to enable analysis of patterns of gaze in real time.

Moore, Steven T.↗

Comments on Lambeck and Coleman - 'The earth's shape and gravity field: A report of progress from 1958 to 1982'

The accuracy and validation of global gravity models based on satellite data are discussed, responding to the statistical analysis of Lambeck and Coleman (1983) (LC). Included are an evaluation of the LC error spectra, a summary of independent-observation calibrations of the error estimates of the Goddard Earth Models (GEM) 9 and L2 (Lerch et al., 1977, 1979, 1982, 1983, and 1985), a comparison of GEM-L2 with GRIM-3B (Reigber et al., 1983), a comparison of recent models with LAGEOS laser ranging, and a summary of resonant-orbit model tests. It is concluded that the accuracy of GEMs 9, 10, and L2 is much higher than claimed by LC, that the GEMs are in good agreement with independent observations and with GRIM-3B, and that the GEM calibrations were adequate. In a reply by LC, a number of specific questions regarding the error estimates are addressed, and it is pointed out that the intermodel discrepancies of the greatest geophysical interest are those in the higher-order coefficients, not discussed in the present comment. It is argued that the differences among the geoid heights of even the most recent models are large enough to call for considerable improvements.

Lerch, F. J.↗

Ground and Airborne Methane Measurements with an Optical Parametric Amplifier

Here we report on measurements made with an improved CO2 Sounder lidar during the ASCENDS 2014 and 2016 airborne campaigns. The changes made to the 2011 version of the lidar included incorporating a rapidly wavelength-tunable, step-locked seed laser in the transmittter, using a much more sensitive HgCdTe APD detector andusing an analog digitizer with faster readout time in the receiver. We also improved the lidar's calibration approach and the XCO2 retrieval algorithm. The 2014 and 2016 flights were made over several types of topographic surfaces from3 to 12 km aircraft altitudes in the continental US. The results are compared to the XCO2 values computed from an airborne in situ sensor during spiral-down maneuvers. The 2014 results show significantly better performance and include measurement of horizontal gradients in XCO2 made over the Midwestern US that agree with chemistry transport models. The results from the 2016 airborne lidar retrievals show precisions of 0:7 parts per million (ppm) with 1 s averaging over desert surfaces, which is an improvement of about 8 times compared to similar measurements made in 2011. Measurements in 2016 were also made over fresh snow surfaces that have lower surface reflectance at the laser wavelengths. The results from both campaigns showed that the mean values of XCO2 retrieved from the lidar consistently agreed with those based on the in situ sensor to within 1 ppm. The improved precision and accuracy demonstrated in the 2014 and 2016 flights should benefit future airborne science ampaigns and advance the technique's readiness for a spacebased instrument.

Numata, Kenji↗