Search NASA⌕ Search

SEARCH · Search NASA

Results for “Linear accelerator structures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Extraction of neutron structure from tagged structure functions

We present work in a model used to describe semi-inclusive deep inelastic scattering off the deuteron. The model uses the virtual nucleon approximation to describe the interaction of the photon with the bound neutron and the generalized eikonal approximation is applied to calculate the final-state interaction diagram. Comparison with data taken at Jefferson Lab shows good agreement in the covered range of kinematics and points at a largely suppressed off-shell rescattering amplitude. The W and Q{sup 2} dependences of the total cross section and slope factor of the interaction of DIS products, X, off the spectator nucleon are extracted. Starting from the JLab data and our model calculations, we outline and apply an extrapolation method to obtain the neutron structure function F{sub 2N} at high Bjorken x.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

GronOR: Massively Parallel and GPU-Accelerated Non-Orthogonal Configuration Interaction for Large Molecular Systems

GronOR is a program package for non-orthogonal configuration interaction calculations for an electronic wave function built in terms of anti-symmetrized products of multi-configuration molecular fragment wave functions. The two-electron integrals that have to be processed may be expressed in terms of atomic orbitals or in terms of an orbital basis determined from the molecular orbitals of the fragments. The code has been specifically designed for execution on distributed memory massively parallel and Graphics Processing Unit (GPU)-accelerated computer architectures, using an MPI+OpenACC/OpenMP programming approach. The task-based execution model used in the implementation allows for linear scaling with the number of nodes on the largest pre-exascale architectures available, provides hardware fault resiliency, and enables effective execution on systems with distinct central processing unit-only and GPU-accelerated partitions. The code interfaces with existing multi-configuration electronic structure codes that provide optimized molecular fragment orbitals, configuration interaction coefficients, and the required integrals. Algorithm and implementation details, parallel and accelerated performance benchmarks, and an analysis of the sensitivity of the accuracy of results and computational performance to thresholds used in the calculations are presented.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Performance Limiting Effects in X-Band Accelerators

Acceleration gradient is a critical parameter for the design of future TeV-scale linear colliders. The major obstacle to higher gradient in room-temperature accelerators is rf breakdown, which is still a very mysterious phenomenon that depends on the geometry and material of the accelerator as well as the input power and operating frequency. Pulsed heating has been associated with breakdown for many years however there have been no experiments that clearly separate field and heating effects on the breakdown rate. Recently, such experiments have been performed at SLAC with both standing-wave and travelling-wave structures. These experiments have demonstrated that pulsed heating is limiting the gradient. Also, a dual-moded cavity has been designed to better distinguish the electric field, magnetic field and pulsed heating effects on breakdown.

43 PARTICLE ACCELERATORS↗

Acceleration of GPU-based Krylov solvers via data transfer reduction

Krylov subspace iterative solvers are often the method of choice when solving large sparse linear systems. At the same time, hardware accelerators such as graphics processing units continue to offer significant floating point performance gains for matrix and vector computations through easy-to-use libraries of computational kernels. However, as these libraries are usually composed of a well optimized but limited set of linear algebra operations, applications that use them often fail to reduce certain data communications, and hence fail to leverage the full potential of the accelerator. In this study, we target the acceleration of Krylov subspace iterative methods for graphics processing units, and in particular the Biconjugate Gradient Stabilized solver that significant improvement can be achieved by reformulating the method to reduce data-communications through application-specific kernels instead of using the generic BLAS kernels, e.g. as provided by NVIDIA’s cuBLAS library, and by designing a graphics processing unit specific sparse matrix-vector product kernel that is able to more efficiently use the graphics processing unit’s computing power. Furthermore, we derive a model estimating the performance improvement, and use experimental data to validate the expected runtime savings. Finally, considering that the derived implementation achieves significantly higher performance, we assert that similar optimizations addressing algorithm structure, as well as sparse matrix-vector, are crucial for the subsequent development of high-performance graphics processing units accelerated Krylov subspace iterative methods.

97 MATHEMATICS AND COMPUTING↗

SU-C-BRB-05: Investigation of Conformal Arc Therapy Utilizing Newly Designed Cobalt 60 Machine

Purpose: A new modernized design for cobalt 60 (Co-60) machines is being developed with a ring type gantry. In this study we investigate the beneficial outcome of the new design for conformal arc therapy for various clinical sites. The new modality was evaluated based on isodose distributions and dose volume histograms as compared to 6MV photon beams from conventional linear accelerators. Methods: Computed tomographic images of seven different SBRT patients were selected from our patient database. All of these cases were previously planned on the Eclipse treatment planning system. New plans for these patients were generated with a modified conformal arc technique using both 6MV and Co-60 beams. The conformal arc was created by the delivery of treatment fields conformal to the target cross-section at every 5 or 10 degrees. The field shape was modified or turned off when it initially passed through a critical structure. Monte Carlo codes, MCBEAM and MCPLAN, were used for the machine head simulation and phantom/patient dose calculation, respectively. In the new Co-60 machine design, the source-to-isocenter distance was 60cm and the treatment head included the Co-60 source, primary collimator, jaws and MLC. Results: For all cases investigated, conformal arc plans utilizing Co-60 beams achieved similar conformity (mean conformity index=1.19) comparing to 6MV photon beams. Isodose distributions were tailored similarly around the PTV; both Co-60 and 6MV plans met our clinical acceptance criteria for the target coverage, and the maximum and minimum target doses. The DVH for the Co-60 plans showed slightly lower doses to the critical structures although the differences were small in most cases. Conclusion: There were no significant dosimetric differences between 6MV and Co-60 plans. Our results confirmed that this new Co-60 design could be a cost-effective machine for advanced radiotherapy due to its low cost, low maintenance and high up time.

60 APPLIED LIFE SCIENCES↗

Design of RF Feed System for Standing-Wave Accelerator Structures

We are investigating a standing wave structure with an rf feed to each individual cell. This approach minimizes rf power flow and electromagnetic energy absorbed by an rf breakdown. The objective of this work is a robust high-gradient (above 100 MV/m) X-band accelerator structure.

43 PARTICLE ACCELERATORS↗

Mitigation of Beam Losses in LANSCE Linear Accelerator

Suppression of beam losses is essential for successful operation of high-intensity accelerator facility. The LANSCE accelerator started routine operation in 1972 as a 0.8 MW average proton beam power facility for meson physics research, and delivered highpower beam for a quarter century. The accelerator currently delivers 100 MeV proton beam to Isotope Production Facility (IPF) and 800 MeV H- beams to various experimental areas. The accelerator is equipped with two independent injectors for H + and H - beams, merging at the entrance of a 201.25 MHz Drift Tube Linac (DTL). The DTL performs acceleration up to the energy of 100 MeV. After the DTL, the Transition Region beamline directs a 100 MeV proton beam to the Isotope Production Facility, while the H - beam is accelerated up to the final energy of 800 MeV in an 805- MHz Coupled Cavity Linac. The H - beams, created with different time structure by a lowenergy chopper, are distributed in the Switch Yard (SY) to four experimental areas: the Lujan Neutron Scattering Center equipped with a Proton Storage Ring (PSR), the Weapons Neutron Research facility (WNR), the Proton Radiography facility (pRad), and the Ultra-Cold Neutron facility (UCN). Multi-beam operation requires careful control of accelerator tune to minimize beam losses. In this paper we review main effects affecting beam losses in LANSCE linear accelerator and discuss methods to reduce them.

43 PARTICLE ACCELERATORS↗

Microbially mediated mechanisms underlie soil carbon accrual by conservation agriculture under decade-long warming

Increasing soil organic carbon (SOC) in croplands by switching from conventional to conservation management may be hampered by stimulated microbial decomposition under warming. Here, we test the interactive effects of agricultural management and warming on SOC persistence and underlying microbial mechanisms in a decade-long controlled experiment on a wheat-maize cropping system. Warming increased SOC content and accelerated fungal community temporal turnover under conservation agriculture (no tillage, chopped crop residue), but not under conventional agriculture (annual tillage, crop residue removed). Microbial carbon use efficiency (CUE) and growth increased linearly over time, with stronger positive warming effects after 5 years under conservation agriculture. According to structural equation models, these increases arose from greater carbon inputs from the crops, which indirectly controlled microbial CUE via changes in fungal communities. As a result, fungal necromass increased from 28 to 53%, emerging as the strongest predictor of SOC content. Collectively, our results demonstrate how management and climatic factors can interact to alter microbial community composition, physiology and functions and, in turn, SOC formation and accrual in croplands.

59 BASIC BIOLOGICAL SCIENCES↗

Spectroscopy of {Lambda} hypernuclei in the (e, e'K{sup +}) reaction at Jefferson Lab

The coincidence experiment E01-011 (HKS), conducted in Hall C at Jefferson Laboratory in fall 2005, represents a new generation of high resolution {Lambda} hypernuclei spectroscopy experiments. It exploits the benefits of the associated electroproduction mechanism via the (e, e'K{sup +}) reaction. Compared with the widely studied meson-induced reactions, the higher quality quasi-continuous electron beam produces the potential for high resolution energy spectra. Further, it provides information complementary to meson-induced reactions: light neutron-rich and mirror hypernuclei, enhanced population of states accessible by spin-flip channels. The newly introduced tilt method of the electron spectrometer (ENGE) greatly reduced the rate of the background electrons due to Bremsstrahlung and Moeller scattering. A brand new high resolution kaon spectrometer (HKS) together with a sophisticated detector package yielded excellent PID and momentum resolution. This resulted in quality missing mass spectra with energy resolution of approximately 400-500 keV (FWHM), an unprecedented value in hypernuclear reaction spectroscopy. The experiment measured the spectra of exotic neutron rich and mirror {Lambda} hypernuclei {sub {Lambda}}{sup 7}He, {sub {Lambda}}{sup 12}B, {sub {Lambda}}{sup 28}Al with high statistics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Megavoltage Image-Based Dynamic Multileaf Collimator Tracking of a NiTi Stent in Porcine Lungs on a Linear Accelerator

Purpose: To investigate the accuracy and potential limitations of MV image-based dynamic multileaf collimator (DMLC) tracking in a porcine model on a linear accelerator. Methods and Materials: A thermo-expandable NiTi stent designed for kilovoltage (kV) X-ray visualization of lung lesions was inserted into the bronchia of three anaesthetized Goettingen minipigs. A four-dimensional computed tomography scan was used for planning a five-field conformal treatment with circular multileaf collimator (MLC) apertures. A 22.5 Gy single fraction treatment was delivered to the pigs. The peak-to-peak stent motion was 3 to 8 mm, with breathing periods of 1.2 to 4 s. Before treatment, X-ray images were used for image-guided setup based on the stent. During treatment delivery, continuous megavoltage (MV) portal images were acquired at 7.5 Hz. The stent was segmented in the images and used for continuous adaptation of the MLC aperture. Offline, the tracking error in beam's eye view of the treatment beam was calculated for each MV image as the difference between the MLC aperture center and the segmented stent position. The standard deviations of the systematic error {Sigma} and the random error {sigma} were determined and compared with the would-be errors for a nontracking treatment with pretreatment image-guided setup. Results: Reliable stent segmentation was obtained for 11 of 15 fields. Segmentation failures occurred when image contrast was dominated by overlapping anatomical structures (ribs, diaphragm) rather than by the stent, which was designed for kV rather than MV X-ray visibility. For the 11 fields with reliable segmentation, {Sigma} was 0.5 mm/0.4 mm in the two imager directions, whereas {sigma} was 0.5 mm/1.1 mm. Without tracking, {Sigma} and {sigma} would have been 1.7 mm/1.4 mm and 0.8 mm/1.4 mm, respectively. Conclusion: For the first time, in vivo DMLC tracking has been demonstrated on a linear accelerator showing the potential for improved targeting accuracy. The study mimicked the envisioned patient workflow of future patient treatments. Clinical implementation of MV image-based tracking would require markers designed for MV visibility.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-J-21: Clinical Evaluation of Surface Scanning Systems in Different Treatment Locations

Purpose: To reduce imaging dose in fractionated IGRT, the ability of optical surface imaging systems (OSIS) to detect setup errors was tested. Therefore, clinical studies to evaluate for different treatment locations setup corrections derived by OSIS in comparison with x-ray image guidance in fractionated radiation therapy was performed. Methods: The setup correction accuracy of an OSIS system (AlignRT, VisionRT, London, UK) will be analysed for the 4 tumour locations Pelvis, Upper Abdomen, Thorax and Breast, 20 patients for each location in comparison to a different system (Sentinel, C-RAD, SE). For each patient, the setup corrections of the cone-beam computed tomography (CBCT) of an Elekta Versa HD linear accelerator (Elekta, Crawley, UK) is considered as gold-standard and then compared with those of the OSIS for the first ten fractions retrospectively. There were no clinical decisions made based on the surrogate system. For the OSIS, the reference surface is highly important as it represents the actual ground truth. It can be obtained either with the system itself or the surface structure delineated in the planning CT can be imported via DICOM interface. In this paper, the first results for the treatment region thorax are presented. The reference image modalities were compared. Results: Table 1 displays the difference between the setup corrections obtained with OSIS and CBCT in lateral (LAT), longitudinal (LNG) and vertical (VRT) direction for the DICOM reference image. While the median deviations are within a few millimeters, some outliers showed large deviations. Generally, the mean deviation as well as the spread was smallest in lateral and largest in vertical direction. Conclusion: Although the system allows fast, simple and non-invasive determination of setup corrections, it should be evaluated treatment region dependant. Therefore, the study is ongoing. The application of OSIS may help to reduce the imaging dose for the patient. We gratefully acknowledge the support by our colleagues from the Radiological University Clinic Heidelberg, where the study was performed. This work was funded by the Federal Ministry of Education and Research (BMBF) Germany, grant number 01IB13001B.

60 APPLIED LIFE SCIENCES↗

Self-consistent core-pedestal transport simulations with neural network accelerated models

Fusion whole device modeling simulations require comprehensive models that are simultaneously physically accurate, fast, robust, and predictive. In this paper we describe the development of two neural-network (NN) based models as a means to perform a snon-linear multivariate regression of theory-based models for the core turbulent transport fluxes, and the pedestal structure. Specifically, we find that a NN-based approach can be used to consistently reproduce the results of the TGLF and EPED1 theory-based models over a broad range of plasma regimes, and with a computational speedup of several orders of magnitudes. These models are then integrated into a predictive workflow that allows prediction with self-consistent core-pedestal coupling of the kinetic profiles within the last closed flux surface of the plasma. Finally, the NN paradigm is capable of breaking the speed-accuracy trade-off that is expected of traditional numerical physics models, and can provide the missing link towards self-consistent coupled core-pedestal whole device modeling simulations that are physically accurate and yet take only seconds to run.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Anisotropic compression of a synthetic potassium aluminogermanate zeolite with gismondine topology

Compression behavior of a potassium aluminogermanate with a gismondine framework topology (K-AlGe-GIS) was studied using in-situ high-pressure synchrotron X-ray powder diffraction. In contrast to the potassium gallosilicate analogue (K-GaSi-GIS), no elastic anomaly due to pressure-induced hydration and/or cation relocation was observed in K-AlGe-GIS. The Birch-Murnaghan fit to the pressure-volume data results in a bulk modulus of B{sub 0} = 31(1) GPa. The derived linear-axial compressibilities (i.e., {beta}{sub a} = 0.0065(5) GPa{sup -1}, {beta}{sub b} = 0.0196(4) GPa{sup -1}, {beta}{sub c} = 0.0081(7) GPa{sup -1}) indicate that the b-axis, normal to the 8-ring channels, is about three times more compressible than the a and c axes, parallel to the elliptical 8-ring channels. As a consequence a gradual flattening of the so-called 'double crankshaft' structural building units of the gismondine framework is observed. In K-AlGe-GIS, this flattening occurs almost linear with pressure, whereas it is nonlinear in the GaSi-analogue due to structural changes of the water-cation assembly under hydrostatic pressures.

43 PARTICLE ACCELERATORS↗

Threshold charmonium photoproduction with GlueX

We report the total and differential cross sections for J/ψ photoproduction obtained using the large acceptance GlueX spectrometer at the 12 GeV JLab accelerator over the full near-threshold kinematic region. The GlueX experiment uses tagged linearly-polarized photon beam from coherent Bremsstrahlung off a thin diamond. Charmonium photoproduction near threshold, under certain assumptions including gluon exchange and factorization, can be used to study important aspects of the gluon structure of the proton, such as the gluon GPD, the gravitational form factors, the mass radius of the proton, and the anomalous contribution to the proton mass. In the measured cross sections we find evidence for possible contributions beyond gluon exchange. The results are compared to a wide range of theoretical predictions including GPD calculations and models with open-charm intermediate states. Photoproduction near threshold of charmonium states with opposite-to-photon parity offer another opportunity, complementary to the J/ψ, to understand the reaction mechanism of the charmonium photoproduction. While we see some evidence for such states, comprehensive studies of such higher-mass charmonia can be done only with the proposed JLab energy upgrade. An electron beam energy of up to 22 GeV significantly increases the photon flux and polarization in the corresponding threshold regions allowing for precise cross section and polarization measurements there.

Pentchev, Lubomir↗

Mechanism of generating fast electrons by an intense laser at a steep overdense interface

The acceleration and heating of electrons by an intense laser normally incident on a steep overdense plasma interface is investigated using the particle-in-cell code osiris. Energetic electrons are generated by the laser's electric field in the vacuum region within {lambda}/4 of the surface. Only those electrons which originate within the plasma with a sufficiently large transverse momentum can escape the plasma. This mechanism relies on the standing wave structure created by the incoming and reflected wave and is therefore very different for linear and circularly polarized light.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Overview of Photoinjectors

High-brightness electron beam sources play a crucial role in many advanced acceleration schemes as well as linac-based light sources such as Energy Recovery Linac (ERL) based light sources and FELs. Three varieties electron sources (photo, thermionic, and field emission) the photoinjector is especially attractive due to its innate ability to control the time structure of intense electron bunches with low transverse and longitudinal emittance. In all cases, the quality of the bunch begins with the intrinsic emittance and time response of the photocathode, and we discuss the trade-offs involved between the various material choices. A variety of longitudinal laser pulse-shaping techniques are currently being developed to linearize space charge forces or create trains of ultra-short bunches. The emittance compensation technique mitigates the growth of the projected emittance due to the linear space charge force while the bunch is accelerated and compressed in an injector. While the normal conducting rf photoinjector is the workhorse of this field, the dc photoinjector is being pushed to its high-voltage limits, and the year 2010 promises to be a critical year for the superconducting rf photoinjector. Parallel to the development of the hardware, rapid progress has also been made with modeling codes, theory, and bench marking of diagnostics. We attempt to give both a tutorial of photoinjectors and a review of the current state of the art in this rapidly developing field.

43 PARTICLE ACCELERATORS↗

Vibration Model Validation for Linear Collider Detector Platforms

The ILC and CLIC reference designs incorporate reinforced-concrete platforms underneath the detectors so that the two detectors can each be moved onto and off of the beamline in a Push-Pull configuration. These platforms could potentially amplify ground vibrations, which would reduce luminosity. In this paper we compare vibration models to experimental data on reinforced concrete structures, estimate the impact on luminosity, and summarize implications for the design of a reinforced concrete platform for the ILC or CLIC detectors.

43 PARTICLE ACCELERATORS↗

The Injection System of the INFN-SuperB Factory Project: Preliminary Design

The ultra high luminosity B-factory (SuperB) project of INFN requires a high performance and reliable injection system, providing electrons at 4 GeV and positrons at 7 GeV, to fulfil the very tight requirements of the collider. Due to the short beam lifetime, continuous injection of electron and positron bunches in both LER and HER rings is necessary to maintain an high average luminosity. Polarized electrons are required for experiments and must be delivered by the injection system, due to the beam lifetime shorter than the ring polarization build-up: they will be produced by means of a SLAC-SLC polarized gun. The emittance and the energy spread of the e{sup -}/e{sup +} beams are reduced in a 1 GeV Damping Ring (DR) before injection in the main rings. Two schemes for positron production are under study, one with e{sup -}/e{sup +} conversion at low energy (< 1 Gev) and one with conversion at 6 GeV and a recirculation line to bring the positrons back to the DR. Acceleration through the Linac is provided by a 2856 MHz RF system made of travelling wave (TW), room temperature accelerating structures.

43 PARTICLE ACCELERATORS↗