Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNETIC INSTRUMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

DVCS - HERMES

The study of Generalised Parton Distributions (GPDs) promises to provide new knowledge of the structure of the nucleon, including, most notably, access to the total angular momentum of quarks within the nucleon. It can be difficult to ascertain new information on the distributions, but amongst all the exclusive processes that can provide access, Deeply Virtual Compton Scattering (DVCS) is relatively simple and experimentally accessible. The HERMES collaboration has the most diverse results pertaining to DVCS of any experiment, extracting asymmetries in the azimuthal distribution of produced photons according to both beam helicity and charge and target spin state. In this talk, we provide an overview of the HERMES DVCS result catalogue and explain how the results are used to improve constraints on the underlying GPDs.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Portable 16-channel Magnetic Sensor for Human Magnetocardiographic Experiments

Here, we constructed a portable, low-cost 16-channel magnetic sensor for magnetocardiography (MCG) applications. The sensor is based on a high-sensitivity optically pumped magnetometer (OPM) with a novel configuration of nearly parallel pump and probe laser beams. The OPM-based 16-channel magnetic sensing is realized in a single module by using a fairly large rubidium vapor cell, broad pump/probe laser beams, and a 16-channel photodiode array, leading projected 10-fold reduction of the cost of sensors. The portability of the sensor is achieved by coupling the pump and probe lasers to OPM optics through multi-mode optical fibers. The 16-channel magnetic sensor is surrounded by a non-magnetic enclosure for safe operation. For MCG experiments with the sensor, its main components except lasers are located inside a magnetically shielded room (MSR), which reduces the ambient magnetic noise. The location of lasers and supporting electronics outside the MSR improves the sensitivity of the sensor. We report that the 16-channel magnetic sensor has a magnetic field sensitivity sufficient to directly detect the human cardiac magnetic signals.

16-channel magnetic sensing↗

2003 Mars Exploration Rover Mission: Robotic Field Geologists for a Mars Sample Return Mission

The Mars Exploration Rover (MER) Spirit landed in Gusev crater on Jan. 4, 2004 and the rover Opportunity arrived on the plains of Meridiani Planum on Jan. 25, 2004. The rovers continue to return new discoveries after 4 continuous Earth years of operations on the surface of the red planet. Spirit has successfully traversed 7.5 km over the Gusev crater plains, ascended to the top of Husband Hill, and entered into the Inner Basin of the Columbia Hills. Opportunity has traveled nearly 12 km over flat plains of Meridiani and descended into several impact craters. Spirit and Opportunity carry an integrated suite of scientific instruments and tools called the Athena science payload. The Athena science payload consists of the 1) Panoramic Camera (Pancam) that provides high-resolution, color stereo imaging, 2) Miniature Thermal Emission Spectrometer (Mini-TES) that provides spectral cubes at mid-infrared wavelengths, 3) Microscopic Imager (MI) for close-up imaging, 4) Alpha Particle X-Ray Spectrometer (APXS) for elemental chemistry, 5) Moessbauer Spectrometer (MB) for the mineralogy of Fe-bearing materials, 6) Rock Abrasion Tool (RAT) for removing dusty and weathered surfaces and exposing fresh rock underneath, and 7) Magnetic Properties Experiment that allow the instruments to study the composition of magnetic martian materials [1]. The primary objective of the Athena science investigation is to explore two sites on the martian surface where water may once have been present, and to assess past environmental conditions at those sites and their suitability for life. The Athena science instruments have made numerous scientific discoveries over the 4 plus years of operations. The objectives of this paper are to 1) describe the major scientific discoveries of the MER robotic field geologists and 2) briefly summarize what major outstanding questions were not answered by MER that might be addressed by returning samples to our laboratories on Earth.

Ming, Douglas W.↗

Electron cyclotron emission detection of neoclassical tearing modes for control for ITER

Successful operation of ITER requires control of magnetic instabilities including neoclassical tearing modes (NTMs) that can degrade confinement and lead to disruption. Low latency detection by electron cyclotron emission (ECE) diagnostics has been demonstrated in a few current experiments. Using a synthetic diagnostic, we demonstrate low latency NTM detection for ITER with plasmas described by ITER IMAS database scenarios and with realistic limitations imposed on the instrumentation by these high temperature scenarios. 2/1 NTMs are detected 430 ms after magnetic island seeding and before island locking. The radiometer configuration was optimized using simulation, and the smallest detectable island size was explored. Island sizes of ∼3 cm are detectable at the 2/1 surface. The simulated signals incorporate recent physics models for island growth and rotation, which show early locking and continued island growth after locking and before disruption. This work determines limits for ITER ECE spatial resolution imposed by relativistic broadening of channels, which informs hardware design. Real-time detection is demonstrated in hardware that is required by ITER, including on an NI PXI-7853R FPGA system. Development of a synthetic diagnostic and details of the hardware will be discussed.

Cyclotron radiation↗

Survey of radiation belt energetic electron pitch angle distributions based on the Van Allen Probes MagEIS measurements: Electron Pitch Angle Distributions

A statistical survey of electron pitch angle distributions (PADs) is performed based on the pitch angle-resolved flux observations from the Magnetic Electron Ion Spectrometer (MagEIS) instrument on board the Van Allen Probes during the period from 1 October 2012 to 1 May 2015. By fitting the measured PADs to a sin n α form, where α is the local pitch angle and n is the power law index, we investigate the dependence of PADs on electron kinetic energy, magnetic local time (MLT), the geomagnetic Kp index, and L shell. The difference in electron PADs between the inner and outer belt is distinct. In the outer belt, the common averaged n values are less than 1.5, except for large values of the Kp index and high electron energies. The averaged n values vary considerably with MLT, with a peak in the afternoon sector and an increase with increasing L shell. In the inner belt, the averaged n values are much larger, with a common value greater than 2. The PADs show a slight dependence on MLT, with a weak maximum at noon. A distinct region with steep PADs lies in the outer edge of the inner belt where the electron flux is relatively low. The distance between the inner and outer belt and the intensity of the geomagnetic activity together determine the variation of PADs in the inner belt. Finally, besides being dependent on electron energy, magnetic activity, and L shell, the results show a clear dependence on MLT, with higher n values on the dayside.

79 ASTRONOMY AND ASTROPHYSICS↗

The electromagnetic environment for the Space Shuttle orbiter

The electromagnetic environment of the Shuttle orbiter is discussed with respect to the electromagnetic compatibility of the orbiter and its cargo. Effects on payloads of the orbiter's Ku-band antenna are considered, along with the effects of unintentional emissions in the cargo bay, the magnetic fields produced by the orbiter and various payloads, lightning-produced magnetic fields, and noise and transients in the AC and DC power buses. Special EMI testing is described that was carried out to substantiate the orbiter's electromagnetic compatibility. It is concluded that the orbiter presents a very benign electromagnetic environment for cargo except for payloads or experiments that use very sensitive receivers or instruments that can measure low magnetic or electric fields.

Giffin, B. L.↗

Coaxial Electric Heaters

Coaxial electric heaters have been conceived for use in highly sensitive instruments in which there are requirements for compact heaters but stray magnetic fields associated with heater electric currents would adversely affect operation. Such instruments include atomic clocks and magnetometers that utilize heated atomic-sample cells, wherein stray magnetic fields at picotesla levels could introduce systematic errors into instrument readings. A coaxial electric heater is essentially an axisymmetric coaxial cable, the outer conductor of which is deliberately made highly electrically resistive so that it can serve as a heating element. As in the cases of other axisymmetric coaxial cables, the equal magnitude electric currents flowing in opposite directions along the inner and outer conductors give rise to zero net magnetic field outside the outer conductor. Hence, a coaxial electric heater can be placed near an atomic-sample cell or other sensitive device. A coaxial electric heater can be fabricated from an insulated copper wire, the copper core of which serves as the inner conductor. For example, in one approach, the insulated wire is dipped in a colloidal graphite emulsion, then the emulsion-coated wire is dried to form a thin, uniform, highly electrically resistive film that serves as the outer conductor. Then the film is coated with a protective layer of high-temperature epoxy except at the end to be electrically connected to the power supply. Next, the insulation is stripped from the wire at that end. Finally, electrical leads from the heater power supply are attached to the exposed portions of the wire and the resistive film. The resistance of the graphite film can be tailored via its thickness. Alternatively, the film can be made from an electrically conductive paint, other than a colloidal graphite emulsion, chosen to impart the desired resistance. Yet another alternative is to tailor the resistance of a graphite film by exploiting the fact that its resistance can be changed permanently within about 10 percent by heating it to a temperature above 300 C. A coaxial heater, with electrical leads attached, that has been bent into an almost full circle for edge heating of a circular window is shown. (In the specific application, there is a requirement for a heated cell window, through which an optical beam enters the cell.)

Strekalov, Dmitry↗

A tandem time–of–flight spectrometer for negative–ion/positive–ion coincidence measurements with soft x-ray excitation

We present a newly constructed spectrometer for negative–ion/positive–ion coincidence spectroscopy of gaseous samples. The instrument consists of two time–of–flight ion spectrometers and a magnetic momentum filter for deflection of electrons. The instrument can measure double and triple coincidences between mass–resolved negative and positive ions with high detection efficiency. First results include identification of several negative–ion/positive–ion coincidence channels following inner-shell photoexcitation of sulfur hexafluoride (SF{sub 6})

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of conductivity and permittivity on samples sealed in nuclear magnetic resonance tubes

We present a broadband impedance spectroscopy instrument designed to measure conductivity and/or permittivity for samples that are sealed in glass tubes, such as the standard 5 mm tubes used for nuclear magnetic resonance experiments. The calibrations and corrections required to extract the dielectric properties of the sample itself are outlined. It is demonstrated that good estimates of the value of dc-conductivity can be obtained even without correcting for the effects of glass or air on the overall impedance. The approach is validated by comparing data obtained from samples sealed in nuclear magnetic resonance tubes with those from standard dielectric cells, using glycerol and butylmethylimidazolium-hexafluorophosphate as respective examples of a molecular and an ionic liquid. This instrument and approach may prove useful for other studies of permittivity and conductivity where contact to the metal electrodes or to the ambient atmosphere needs to be avoided.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Determining Confounding Sensitivities In Eddy Current Thin Film Measurements

Determining Confounding Sensitivities In Eddy Current Thin Film Measurements Ethan Gros, Lalita Udpa, Electrical Engineering, Michigan State University, East Lansing MI 48824 James A. Smith, Experiment Analysis, Idaho National Laboratory, Idaho Falls ID 83415 Eddy current (EC) techniques are widely used in industry to measure the thickness of non-conductive films on a metal substrate. This is done using a system whereby a coil carrying a high-frequency alternating current is used to create an alternating magnetic field at the surface of the instrument's probe. When the probe is brought near a conductive surface, the alternating magnetic field will induce ECs in the conductor. The substrate characteristics and the distance of the probe from the substrate (the coating thickness) affect the magnitude of the ECs. The induced currents load the probe coil affecting the terminal impedance of the coil. The measured probe impedance is related to the lift off between coil and conductor as well as conductivity of the test sample. For a known conductivity sample, the probe impedance can be converted into an equivalent film thickness value. The EC measurement can be confounded by a number of measurement parameters. It is the goal of this research to determine which physical properties of the measurement set-up and sample can adversely affect the thickness measurement. The eddy current testing is performed using a commercially available, hand held eddy current probe (ETA3.3H spring loaded eddy probe running at 8 MHz) that comes with a stand to hold the probe. The stand holds the probe and adjusts the probe on the z-axis to help position the probe in the correct area as well as make precise measurements. The signal from the probe is sent to a hand held readout, where the results are recorded directly in terms of liftoff or film thickness. Understanding the effect of certain factors on the measurements of film thickness, will help to evaluate how accurate the ETA3.3H spring loaded eddy probe is at measuring film thickness under varying experimental conditions. This research will study the effects of a number of factors such as i) calibration, ii) conductivity, iii) edge effect, iv) surface finish of base material and v) cable condition and compare with the long term reproducibility of a standard measurement. This work was performed with support from the Department of Energy under the United States National Nuclear Security Administration (NNSA) at the Idaho National Laboratory.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Magnetic Field Sensing via Acoustic Sensing Fiber with Metglas® 2605SC Cladding Wires

Magnetic field sensing has the potential to become necessary as a critical tool for long-term subsurface geophysical monitoring. The success of distributed fiber optic sensing for geophysical characterization provides a template for the development of next generation downhole magnetic sensors. In this study, Sentek Instrument’s picoDAS is coupled with a multi-material single mode optical fiber with Metglas® 2605SC cladding wire inclusions for magnetic field detection. The response of acoustic sensing fibers with one and two Metglas® 2605SC cladding wires was evaluated upon exposure to lateral AC magnetic fields. An improved response was demonstrated for a sensing fiber with in-cladding wire following thermal magnetic annealing (~400 °C) under a constant static transverse magnetic field (~200 μT). A minimal detectable magnetic field of ~500 nT was confirmed for a sensing fiber with two 10 μm cladding wires. The successful demonstration of a magnetic field sensing fiber with Metglas® cladding wires fabricated via traditional draw processes sets the stage for distributed measurements and joint inversion as a compliment to distributed fiber optic acoustic sensors.

Dejneka, Zach (ORCID:0000000179415708)↗

Development of ultrastable filters and lasers for solar seismology

The Stable Solar Analyzer is a recently developed instrument for the measurement of solar magnetic fields and surface velocities that is being employed at the U.S. National Solar Observatory to study the subsurface convection cells of the sun and the structure of surface and subsurface magnetic fields. The Analyzer is expected to ultimately be flown aboard such spacecraft as the ESA/NASA Solar and Heliospheric Observatory. This instrument is based on a crystalline lithium niobate Fabry-Perot filter that is used in conjunction with a stabilized laser that furnishes an absolute wavelength reference; this laser Fabry-Perot combination has achieved wavelength stabilities of the order of 2 parts in 10 to the 10th, over a six-hour interval.

Rust, D. M.↗

Potential aerospace applications of high temperature superconductors

The recent discovery of High Temperature Superconductors (HTS) with superconducting transition temperature, T(sub c), above the boiling point of liquid nitrogen has opened the door for using these materials in new and practical applications. These materials have zero resistance to electric current, have the capability of carrying large currents and as such have the potential to be used in high magnetic field applications. One of the space applications that can use superconductors is electromagnetic launch of payloads to low-earth-orbit. An electromagnetic gun-type launcher can be used in small payload systems that are launched at very high velocity, while sled-type magnetically levitated launcher can be used to launch larger payloads at smaller velocities. Both types of launchers are being studied by NASA and the aerospace industry. The use of superconductors will be essential in any of these types of launchers in order to produce the large magnetic fields required to obtain large thrust forces. Low Temperature Superconductor (LTS) technology is mature enough and can be easily integrated in such systems. As for the HTS, many leading companies are currently producing HTS coils and magnets that potentially can be mass-produced for these launchers. It seems that designing and building a small-scale electromagnetic launcher is the next logical step toward seriously considering this method for launching payloads into low-earth-orbit. A second potential application is the use of HTS to build sensitive portable devices for the use in Non Destructive Evaluation (NDE). Superconducting Quantum Interference Devices (SQUID's) are the most sensitive instruments for measuring changes in magnetic flux. By using HTS in SQUID's, one will be able to design a portable unit that uses liquid nitrogen or a cryocooler pump to explore the use of gradiometers or magnetometers to detect deep cracks or corrosion in structures. A third use is the replacement of Infra-Red (IR) sensor leads on Earth Orbit Systems (EOS) with HTS leads. IR detectors on these EOS missions are cooled to a 4.2K to improve their signal to noise ratio. They are connected to data acquisitions systems using manganin wires (low thermal conductors) to reduce the heat load on the cryogen. Replacing these wires with HTS leads will increase the lifetime of these missions by about 50 percent. This is a promising application that is ready for actual implementation on such systems. The analysis also show that an the number of IR detectors increase in larger EOS systems, substantial increase in the lifetime of each mission will be realized by using HTS leads instead of the manganin ones.

Selim, Raouf↗

The Magnetospheric Multiscale Mission...Resolving Fundamental Processes in Space Plasmas

The Magnetospheric Multiscale (MMS) mission is a multiple-spacecraft Solar-Terrestrial Probe designed to study the microphysics of magnetic reconnection, charged particle acceleration, and turbulence in key boundary regions of Earth's magnetosphere. These three processes, which control the flow of energy, mass, and momentum within and across plasma boundaries, occur throughout the universe and are fundamental to our understanding of astrophysical and solar system plasmas. Only in Earth's magnetosphere, however, are they readily accessible for sustained study through in-situ measurement. MMS will employ five co-orbiting spacecraft identically instrumented to measure electric and magnetic fields, plasmas, and energetic particles. The initial parameters of the individual spacecraft orbits will be designed so that the spacecraft formation will evolve into a three-dimensional configuration near apogee, allowing MMS to differentiate between spatial and temporal effects and to determine the three dimensional geometry of plasma, field, and current structures. In order to sample all of the magnetospheric boundary regions, MMS will employ a unique four-phase orbital strategy involving carefully sequenced changes in the local time and radial distance of apogee and, in the third phase, a change in orbit inclination from 10 degrees to 90 degrees. The nominal mission operational lifetime is two years. Launch is currently scheduled for 2006.

Curtis, S.↗

Observation of critical scaling in spin glasses below T c using thermoremanent magnetization

Time-dependent thermoremanent magnetization (TRM) studies have been instrumental in probing energy dynamics within the spin glass phase. In this paper, we review the evolution of the TRM experiment over the last half century and discuss some aspects related to how it has been used in the understanding of spin glasses. We also report on recent experiments using high-resolution DC SQUID magnetometry to probe the TRM at temperatures less than but near to the transition temperature T c . These experiments have been performed as a function of waiting time, temperature, and five different magnetic fields. We find that as the transition temperature is approached from below, the characteristic time scale of TRM is suppressed up to several orders of magnitude in time. In the highest-temperature region, we find that the waiting time effect subsides, and a waiting time-independent crossover line is reached. We also find that increasing the magnetic field further suppresses the crossover line. Using a first-principles energy argument across the crossover line, we derive an equation that is an excellent fit to the crossover lines for all magnetic fields probed. The data show strong evidence for critical slowing down and an H = 0 Oe phase transition.

36 MATERIALS SCIENCE↗

In-flight jet engine noise measurement system

An instrumentation system in flight tests for noise research is described which utilizes miniature transducers to measure low-amplitude, high-frequency fluctuating pressures in a jet engine mounted under the wing of a turboprop aircraft. The system employs a rotor-mounted FM telemeter to acquire data from eight fan-blade-mounted transducers which are subjected to up to 75,000 g's of loading. Data is transmitted from the rotor to an antenna mounted in the inlet-duct wall using a low-power, close-coupled RF link. The blade pressures and other inlet and stator-vane fluctuating pressures are recorded on airborne, magnetic-tape recorders. The flight instrumentation described also includes PCM techniques to encode and record a variety of quasi-static measurements to provide engine and aircraft performance data. The instrumentation and experimental measurements are of value to an improved understanding of noise sources in jet engines and for the advancement of jet-engine ground noise testing techniques.

Knight, V. H., Jr.↗

ALICE—An advanced reflectometer for static and dynamic experiments in magnetism at synchrotron radiation facilities

We report on significant developments of a high vacuum reflectometer (diffractometer) and spectrometer for soft x-ray synchrotron experiments which allows conducting a wide range of static and dynamic experiments. Although the chamber named ALICE was designed for the analysis of magnetic hetero- and nanostructures via resonant magnetic x-ray scattering, the instrument is not limited to this technique. The versatility of the instrument was testified by a series of pilot experiments. Static measurements involve the possibility to use scattering and spectroscopy synchrotron based techniques (photon-in photon-out, photon-in electron-out, and coherent scattering). Dynamic experiments require either laser or magnetic field pulses to excite the spin system followed by x-ray probe in the time domain from nano- to femtosecond delay times. In this temporal range, the demagnetization/remagnetization dynamics and magnetization precession in a number of magnetic materials (metals, alloys, and magnetic multilayers) can be probed in an element specific manner. We demonstrate here the capabilities of the system to host a variety of experiments, featuring ALICE as one of the most versatile and demanded instruments at the Helmholtz Center in Berlin-BESSY II synchrotron center in Berlin, Germany.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A modular optics design for the LBNE beamline

Protons extracted from the Main Injector (MI) in the MI-60 straight section are transported 84 m through quadrupole Q106 in the NuMI stub, at which point two 6-3-120 vertical switching magnets, followed by three EPB vertical dipoles, steer the beam into the main body of the LBNE beamline. From Q106 in NuMI the LBNE beamline transports these protons 722.0 m to the LBNE target, located 41.77 m (137.0 ft) below the MI beamline center (BLC) elevation, on a trajectory aimed towards DUSEL. Bending is provided (predominantly) by 34 long (6 m) MI-style IDA/IDB and 8 short (4 m) IDC/IDD dipoles [through 48.36{sup o} horizontally and -5.844{sup o} (net) vertically]. Optical properties are defined by 49 quadrupoles (grouped functionally into 44 focusing centers) of the proven MI beamline-style 3Q60/3Q120 series. All focusing centers are equipped with redesigned MI-style IDS orbit correctors and dual-plane beam position monitors (BPM's). Ample space is available in each arc cell to accommodate ion pumps and diagnostic instrumentation. Parameters of the main magnets are listed in a table.

43 PARTICLE ACCELERATORS↗