Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNETIC INSTRUMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Primordial B-mode diagnostics and self-calibrating the CMB polarization

Distortions in the primordial cosmic microwave background (CMB) along the line of sight can be modeled and described using 11 fields. These distortion fields correspond to various cosmological signals such as weak gravitational lensing of the CMB by a large-scale structure, screening from patchy reionization, and rotation of the plane of polarization due to magnetic fields or parity violating physics. Various instrumental systematics such as gain fluctuations, pixel rotation, differential gain, pointing, and differential ellipticity are also described by the same distortion model. All these distortions produce a B mode that contaminates the primordial tensor B-modes signal. In this paper we show that, apart from generating B modes, each distortion uniquely couples different modes (l{sub 1{ne}}l{sub 2}) of the CMB anisotropies, generating <EB> correlations which for the primordial CMB are zero. We describe and implement unbiased minimum variance quadratic estimators which using the off-diagonal correlations in the CMB can extract the map of distortions. We perform Monte Carlo simulations to characterize the estimators and illustrate the level of distortions that can be detected with current and future experiments. The estimators can be used to look for cosmological signals, or to check for any residual systematics in the data. As a specific example of primordial tensor B-mode diagnostics, we compare the level of minimum detectable distortions using our method with maximum allowed distortion level for the B-modes detection. We show that for any experiment, the distortions will be detected at high significance using correlations before they would show up as spurious B modes in the power spectrum. In other words, if B modes were to be detected, the presence of any nonprimordial contribution could be checked and removed using the off-diagonal correlations in the CMB.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Balance Calibration – A Method for Assigning a Direct-Reading Uncertainty to an Electronic Balance.

Paper Title: Balance Calibration – A method for assigning a direct-reading uncertainty to an electronic balance. Intended Audience: Those who calibrate or use electronic balances. Abstract: As a calibration facility, we provide on-site (at the customer’s location) calibrations of electronic balances for customers within our company. In our experience, most of our customers are not using their balance as a comparator, but simply putting an unknown quantity on the balance and reading the displayed mass value. Manufacturer’s specifications for balances typically include specifications such as readability, repeatability, linearity, and sensitivity temperature drift, but what does this all mean when the balance user simply reads the displayed mass value and accepts the reading as the true value? This paper discusses a method for assigning a direct-reading uncertainty to a balance based upon the observed calibration data and the environment where the balance is being used. The method requires input from the customer regarding the environment where the balance is used and encourages discussion with the customer regarding sources of uncertainty and possible means for improvement; the calibration process becomes an educational opportunity for the balance user as well as calibration personnel. This paper will cover the uncertainty analysis applied to the calibration weights used for the field calibration of balances; the uncertainty is calculated over the range of environmental conditions typically encountered in the field and the resulting range of air density. The temperature stability in the area of the balance is discussed with the customer and the temperature range over which the balance calibration is valid is decided upon; the decision is based upon the uncertainty needs of the customer and the desired rigor in monitoring by the customer. Once the environmental limitations are decided, the calibration is performed and the measurement data is entered into a custom spreadsheet. The spreadsheet uses measurement results, along with the manufacturer’s specifications, to assign a direct-read measurement uncertainty to the balance. The fact that the assigned uncertainty is a best-case uncertainty is discussed with the customer; the assigned uncertainty contains no allowance for contributions associated with the unknown weighing sample, such as density, static charges, magnetism, etc. The attendee will learn uncertainty considerations associated with balance calibrations along with one method for assigning an uncertainty to a balance used for non-comparison measurements.

47 OTHER INSTRUMENTATION↗

Scanning tunneling microscope design with a confocal small field permanent magnet.

The field of ultra-sensitive measurements with scanning probes requires the design and construction of novel instruments. For example, the combination of radio frequency detection and scanning probe can be exploited to measure thermal properties and mechanical resonances at a very low scale. Very recent results by Komeda and Manassen (2008 Appl. Phys. Lett. 92 212506) on the detection of spin noise with the scanning tunneling microscopy (STM) have further expanded previous results reported by one of the authors of this manuscript (Messina et al 2007 J. Appl. Phys. 101 053916). In a previous publication, one of the authors used a new STM instrument (Messina et al J. Appl. Phys. 2007 101 053916 and Mannini et al 2007 Inorg. Chim. Acta 360 3837-42) to obtain the detection of electron spin noise (ESN) from individual paramagnetic adsorbates. The magnetic field homogeneity at the STM tip-sample region was limited. Furthermore, vacuum operation of the STM microscope was limited by the heat dissipation at the electromagnet and the radio frequency (RF) recovery electronics. We report here on a new STM head that incorporates a specially designed permanent magnet and in-built RF amplification system. The magnet provides both a better field homogeneity and freedom to operate the instrument in vacuum. The STM microscope is vacuum compatible, and vertical stability has been improved over the previous design (Messina et al 2007 J. Appl. Phys. 101 053916), despite the presence of a heat dissipative RF amplifier in the close vicinity of the STM tip.

47 OTHER INSTRUMENTATION↗

IS MAGNETIC RECONNECTION THE CAUSE OF SUPERSONIC UPFLOWS IN GRANULAR CELLS?

In a previous work, we reported on the discovery of supersonic magnetic upflows on granular cells in data from the SUNRISE/IMaX instrument. In the present work, we investigate the physical origin of these events employing data from the same instrument but with higher spectral sampling. By means of the inversion of Stokes profiles we are able to recover the physical parameters (temperature, magnetic field, line-of-sight velocity, etc.) present in the solar photosphere at the time of these events. The inversion is performed in a Monte-Carlo-like fashion, that is, repeating it many times with different initializations and retaining only the best result. We find that many of the events are characterized by a reversal in the polarity of the magnetic field along the vertical direction in the photosphere, accompanied by an enhancement in the temperature and by supersonic line-of-sight velocities. In about half of the studied events, large blueshifted and redshifted line-of-sight velocities coexist above/below each other. These features can be explained in terms of magnetic reconnection, where the energy stored in the magnetic field is released in the form of kinetic and thermal energy when magnetic field lines of opposite polarities coalesce. However, the agreement with magnetic reconnection is not perfect and, therefore, other possible physical mechanisms might also play a role.

79 ASTRONOMY AND ASTROPHYSICS↗

The GlueX Detector

The GlueX detector is being built along with the new experimental Hall D at Jefferson lab as part of the 12 GeV upgrade project which received CD-3 approval in fall 2008. GlueX is a fixed target experiment built around a 2 Tesla superconducting solenoid having charged particle tracking and calorimetry with large acceptance. A high rate DAQ system consisting of pipeline electronics will allow the detector to operate at high luminosity (10{sup 8} tagged {lambda}/sec on target). Details on the photon beam and GlueX detector are given including capabilities in resolutions and rates.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Vibrational spectroscopy with neutrons: Recent developments

Here in this short review, we will briefly summarise the differences between INS spectroscopy and conventional infrared and Raman spectroscopies. We will illustrate these with the current state-of-the art, using C 70 as an example. The main focus of the article will be on the key advances in INS spectroscopy over the last ten years or so, that are driving new areas of research. The developments fall into three broad categories: (i) new sources, (ii) new and/or upgraded instrumentation and (iii) novel uses for existing instruments. For (i) we summarise the new neutron sources that are now, or will be, operating. For (ii) we show the capabilities of new or upgraded instruments. These offer unprecedented levels of sensitivity: sub-millimole quantities of hydrogen can be measured and millimole quantities of low cross section materials. Recent work on hexahalo metallates and adsorbed CO 2 is used to demonstrate what is now feasible. For (iii), instruments that were designed for studies of magnetism, are now being used for molecular spectroscopy, especially for catalysts. This is illustrated with work on CuH and methanol synthesis catalysts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hot topic, warm loops, cooling plasma? Multithermal analysis of active region loops

We have found indications of a relationship between the differential emission measure (DEM) weighted temperature and the cross-field DEM width for coronal loops. The data come from the Hinode X-ray Telescope, the Hinode EUV Imaging Spectrometer, and the Solar Dynamics Observatory Atmospheric Imaging Assembly. These data show that cooler loops tend to have narrower DEM widths. If most loops observed by these instruments are composed of bundles of unresolved magnetic strands and are only observed in their cooling phase, as some studies have suggested, then this relationship implies that the DEM of a coronal loop narrows as it cools. This could imply that fewer strands are seen emitting in the later cooling phase, potentially resolving the long standing controversy of whether the cross-field temperatures of coronal loops are multithermal or isothermal.

79 ASTRONOMY AND ASTROPHYSICS↗

High-resolution phonon energy shift measurements with the inelastic neutron spin echo technique

The energy resolution of the conventional way of measuring a small change in a phonon dispersion curve using neutron scattering is restricted by the relatively coarse intrinsic resolution ellipsoid of the neutron triple-axis spectrometer (TAS). By implementing inelastic neutron spin echo on the host TAS using the Larmor precession of the neutron spin, the energy resolution of such measurements can be further improved without reducing the resolution ellipsoid. Measurements of the temperature-dependent phonon energy change are demonstrated using superconducting magnetic Wollaston prisms at the HB-1 instrument of the High-Flux Isotope Reactor at Oak Ridge National Laboratory, and the achievable resolution is <10 µeV.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Bifurcation Buckling Analysis and Non-Linear Collapse Analysis of Teardrop Shaped Vacuum Chamber

The Spallation Neutron Source (SNS) accelerator is being upgraded to increase the beam power from 1.4MW at 1GeV to 2.8MW at 1.3GeV. The currents in the middle two injection chicane magnets cannot simply be scaled up to accommodate the increased injection energy of 1.3GeV due to potential excessive H- stripping; the magnets must be replaced with longer, lower-field magnets and the associated vacuum chambers need to be redesigned. A new teardrop-shaped vacuum chamber was initially designed to accommodate the new magnets and the updated beam paths and instrumentation. This paper focuses on the structural stability study of the teardrop shape vacuum chamber based on buckling analysis. Protection against collapse from buckling according to the ASME BPVC requirement has been evaluated in depth. First, a Type-1 bifurcation buckling analysis using a linear eigenvalue solution to determine the critical load factor was performed. Subsequently, a Type-3 nonlinear collapse analysis was conducted using the static Riks method with elastic-plastic material properties and imperfections explicitly considered in the model geometry. The critical buckling load for the teardrop shape vacuum chamber was confidently estimated based upon this two-stage approach.

Jiang, Hao↗

A dedicated mirror-magnet experiment to study quench characteristics and dependencies in $Nb_{3}Sn$ coils and explore improvements of diagnostics capabilities

A single Nb3Sn short quadrupole coil in a mirror-magnet configuration was employed to investigate a wide range of phenomena and to serve as test-bed for diagnostics developments. A configurable array of spot-heaters was installed on the inner coil surface for control of induced quench conditions. Several different quench antenna arrays were positioned along the coil inner surface, and included significant sensor overlap for assessment of their relative efficiency and operation. Multiple acoustic sensors were placed on the pole and at coil ends. Optical fibers in grid configurations were put in different places on the coil and magnet for strain assessment, along with standard resistive strain gauges. Current spikes in the magnet circuit were monitored. This plethora of instrumentation aimed to support investigations on induced and spontaneous quenches, among other goals, and was supplemented by standard voltage-tap-based measurements. Voltage tap data of induced quenches from various spot-heater configurations was investigated for similarities to voltage development in spontaneous quenches. Quench antennas provided insights about current redistribution in the quenching coil and coil splices. The Quench Current-boosting Device was applied and the effect on coil training examined. This paper describes motivations behind the research, the overall test setup and main results.

Stoynev, Stoyan [Fermilab]↗

Objectives and Layout of a High-Resolution X-ray Imaging Crystal Spectrometer for the Large Helical Device (LHD)

A high-resolution X-ray imaging crystal spectrometer, whose concept was tested on NSTX and Alcator C-Mod, is being designed for LHD. This instrument will record spatially resolved spectra of helium-like Ar16+ and provide ion temperature profiles with spatial and temporal resolutions of < 2 cm and ≥ 10 ms. The stellarator equilibrium reconstruction codes, STELLOPT and PIES, will be used for the tomographic inversion of the spectral data. The spectrometer layout and instrumental features are largely determined by the magnetic field structure of LHD.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High precision magnetic field measurement and mapping of the LEReC 180 degree bending magnet using very low field NMR with hall combined probe (140 - 350 gauss)

The Relativistic Heavy Ion Collider (RHIC) at BNL are using the Low Energy RHIC Electron Cooling (LEReC) to conduct experiments that search for the quantum chromodynamic (QCD) critical point. The first ever electron cooling based on the RF acceleration of electron beams was experimentally demonstrated on April 5, 2019 at LEReC at BNL. The first critical step in obtaining successful 3D non-magnetized cooling of the Au ion bunches in the RHIC cooling section was matching the electron beam energy with a relative error less than 5*10 -4 to the ion beam energy. Part of the LEReC beamline is a dipole magnet that bends the electron beam 180 degree. One of the most outstanding measurement challenges is that the dipole field is so low (≈200 G). Most of the existing NMR probes can only measure fields >400 G. Lower signal-to-noise ratio at low fields is requires the use of larger sample volumes. Working with CAYLAR, a NMR probe has been redesigned and optimized for these low field measurements with high resolution. We report the methods, challenges, and results for extensive magnetic field mappings of the 180 dipole magnet. A combination of NMR and Hall sensors has been successfully implemented to measure uniform field regimes inside the magnet center area and non-uniform field regimes at the magnet ends. Detailed measurement and mapping have been performed at five radii and five heights along the beam trajectory. Meanwhile a finite element magnetic modeling simulation of the magnet using Opera software has been performed. The calculated and measured data are compared, and the calculated data is good reference for measured data over long length mapping from magnet edge to center. The measured magnetic measurement data is directly useful for beam instrumentation, diagnostics and operation.

Magnetic Field Measurement↗

Signal processing in the neutral-trigger system of the CMD-3 detector

A method for calorimeter-signal processing intended for deriving input signals for the neutral trigger is considered. An algorithm for digitizing signals is described in detail, along with a simulation of its operation. A brief account of data obtained in tests of a prototype of the signal-processing module that employs the developed algorithm is given.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An imaging proton spectrometer for short-pulse laser plasma experiments

The ultraintense short pulse laser pulses incident on solid targets can generate energetic protons. In addition to their potentially important applications such as in cancer treatments and proton fast ignition, these protons are essential to understand the complex physics of intense laser plasma interaction. To better characterize these laser-produced protons, we designed and constructed a novel spectrometer that will not only measure proton energy distribution with high resolution but also provide its angular characteristics. The information obtained from this spectrometer compliments those from commonly used diagnostics including radiochromic film packs, CR39 nuclear track detectors, and nonimaging magnetic spectrometers. The basic characterizations and sample data from this instrument are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Large magnetoresistance and Fermi surface study of Sb 2 Se 2 Te single crystal

Here, we have studied the magnetotransport properties of a Sb 2 Se 2 Te single crystal. Magnetoresistance (MR) is maximum when the magnetic field is perpendicular to the sample surface and reaches a value of 1100% at B = 31 T with no sign of saturation. MR shows Shubnikov de Haas (SdH) oscillations above B = 15 T. The frequency spectrum of SdH oscillations consists of three distinct peaks at α = 32 T, β = 80 T, and γ = 117 T indicating the presence of three Fermi surface pockets. Among these frequencies, β is the prominent peak in the frequency spectrum of SdH oscillations measured at different tilt angles of the sample with respect to the magnetic field. From the angle dependence β and Berry phase calculations, we have confirmed the trivial topology of the β-pocket. The cyclotron masses of charge carriers, obtained by using the Lifshitz–Kosevich formula, are found to be m$*\atop{β}$= 0.16m o and m$*\atop{γ}$= 0.63m o for the β and γ bands, respectively. The Large MR of Sb 2 Se 2 Te is suitable for utilization in electronic instruments such as computer hard discs, high field magnetic sensors, and memory devices.

36 MATERIALS SCIENCE↗

A hybrid data acquisition system for magnetic measurements of accelerator magnets

A hybrid data acquisition system was developed for magnetic measurement of superconducting accelerator magnets at LBNL. It consists of a National Instruments dynamic signal acquisition (DSA) card and two Metrolab fast digital integrator (FDI) cards. The DSA card records the induced voltage signals from the rotating probe while the FDI cards records the flux increment integrated over a certain angular step. This allows the comparison of the measurements performed with two cards. In this note, the setup and test of the system is summarized. With a probe rotating at a speed of 0.5 Hz, the multipole coefficients of two magnets were measured with the hybrid system. The coefficients from the DSA and FDI cards agree with each other, indicating that the numerical integration of the raw voltage acquired by the DSA card is comparable to the performance of the FDI card in the current measurement setup.

43 PARTICLE ACCELERATORS↗

A versatile X-ray phase retarder for lock-in XMCD measurements

X-ray magnetic circular dichroism (XMCD) is a technique commonly used to probe magnetic properties of materials with element and orbital selectivity, which requires the use of circularly polarized (CP) X-rays. It is possible to accomplish XMCD experiments with fixed CP and alternating the magnetic field orientation, but most reliable data are obtained when alternating the magnetization orientation and the polarization between right and left helicities. A versatile strategy has been developed to perform XMCD experiments using a hard X-ray quarter-wave plate, at both polychromatic dispersive and conventional monochromatic optics, in combination with synchronous data acquisition. The switching frequency waveform is fed into a lock-in amplifier to detect and amplify the XMCD signal. The results on a reference sample demonstrate an improvement in data quality and acquisition time. The instrumentation successfully generated 98% of CP X-rays switching the beam helicity at 13 Hz, with the possibility of faster helicity switching once it is installed at the new Brazilian fourth-generation source, SIRIUS.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗