Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNETIC RESONANCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Folate conjugated Mn{sub 3}O{sub 4}@SiO{sub 2} nanoparticles for targeted magnetic resonance imaging in vivo

Graphical abstract: The Mn{sub 3}O{sub 4}@SiO{sub 2}(PEG)–FA has been used as a T{sub 1}-MRI probe for in vivo. - Highlights: • The PEG and FA modified Mn{sub 3}O{sub 4}@SiO{sub 2} nanoparticles (Mn{sub 3}O{sub 4}@SiO{sub 2}–FA) were prepared. • Mn{sub 3}O{sub 4}@SiO{sub 2}–FA exhibited the good colloidal stability in the simulated biological medium. • Mn{sub 3}O{sub 4}@SiO{sub 2}–FA showed the targeting ability to HeLa cells overexpressed the FA receptor. • The T{sub 1}-weighted magnetic resonance (MR) imaging demonstrated the targeting ability of Mn{sub 3}O{sub 4}@SiO{sub 2}–FA in vivo tumor. - Abstract: The monodisperse silica-coated manganese oxide nanoparticles (Mn{sub 3}O{sub 4}@SiO{sub 2} NPs) were synthesized via the high temperature pyrolysis approach and were aminated through silanization. The amine-functionalized Mn{sub 3}O{sub 4} NPs enabled the covalent conjugation of hydrophilic methoxypoly(ethylene glycol) (PEG) and the targeting ligand of folate (FA) onto their surface. The formed PEG and FA modified Mn{sub 3}O{sub 4} NPs (Mn{sub 3}O{sub 4}@SiO{sub 2}(PEG)–FA) exhibited the good colloidal stability in the simulated biological medium and the targeting ability to HeLa cells overexpressed the FA receptor. The T{sub 1}-weighted magnetic resonance (MR) imaging and inductively coupled plasma atomic emission spectroscopy (ICP-AES) analysis of Mn{sub 3}O{sub 4}@SiO{sub 2}(PEG)–FA NPs further demonstrated their targeting ability in tumor.

36 MATERIALS SCIENCE↗

Nuclear magnetic resonance investigation of superconducting and normal state Nb 3 Sn

The superconductor Nb3Sn has important applications for construction of very high-field superconducting magnets. In this work we investigate its microscopic electronic structure with 93 Nb nuclear magnetic resonance (NMR). The high-quality Nb 3 Sn powder sample was studied in both 3.2 T and 7 T magnetic fields in the temperature range from 4 K to 300 K. From measurement of the spectrum and its theoretical analysis, we find evidence for anisotropy despite its cubic crystal structure. Magnetic alignment of the powder grains in the superconducting state was also observed. The Knight shift and spin-lattice relaxation rate, T 1 -1 , were measured and the latter compared with BCS theory for the energy gap Δ(0) = 2.7 ± 0.3k B T c at 3.2 T and Δ(0) = 2.33 ± 0.07 k B T c at 7 T, indicating suppression of the order parameter by magnetic field.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Magnetic Resonance Lymphography-Guided Selective High-Dose Lymph Node Irradiation in Prostate Cancer

Purpose: To demonstrate the feasibility of magnetic resonance lymphography (MRL) -guided delineation of a boost volume and an elective target volume for pelvic lymph node irradiation in patients with prostate cancer. The feasibility of irradiating these volumes with a high-dose boost to the MRL-positive lymph nodes in conjunction with irradiation of the prostate using intensity-modulated radiotherapy (IMRT) was also investigated. Methods and Materials: In 4 prostate cancer patients with a high risk of lymph node involvement but no enlarged lymph nodes on CT and/or MRI, MRL detected pathological lymph nodes in the pelvis. These lymph nodes were identified and delineated on a radiotherapy planning CT to create a boost volume. Based on the location of the MRL-positive lymph nodes, the standard elective pelvic target volume was individualized. An IMRT plan with a simultaneous integrated boost (SIB) was created with dose prescriptions of 42 Gy to the pelvic target volume, a boost to 60 Gy to the MRL-positive lymph nodes, and 72 Gy to the prostate. Results: All MRL-positive lymph nodes could be identified on the planning CT. This information could be used to delineate a boost volume and to individualize the pelvic target volume for elective irradiation. IMRT planning delivered highly acceptable radiotherapy plans with regard to the prescribed dose levels and the dose to the organs at risk (OARs). Conclusion: MRL can be used to select patients with limited lymph node involvement for pelvic radiotherapy. MRL-guided delineation of a boost volume and an elective pelvic target volume for selective high-dose lymph node irradiation with IMRT is feasible. Whether this approach will result in improved outcome for these patients needs to be investigated in further clinical studies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of Computed Tomography– and Magnetic Resonance Imaging–based Clinical Target Volume Contours at Brachytherapy for Cervical Cancer

Purpose: We prospectively compared computed tomography (CT)– and magnetic resonance imaging (MRI)–based high-risk clinical target volume (HR-CTV) contours at the time of brachytherapy for cervical cancer in an effort to identify patients who might benefit most from MRI-based planning. Methods and Materials: Thirty-seven patients who had undergone a pretreatment diagnostic MRI scan were included in the analysis. We delineated the HR-CTV on the brachytherapy CT and brachytherapy MRI scans independently for each patient. We then calculated the absolute volumes for each HR-CTV and the Dice coefficient of similarity (DC, a measure of spatial agreement) for the HR-CTV contours. We identified the clinical and tumor factors associated with (1) a discrepancy in volume between the CT HR-CTV and MRI HR-CTV contours; and (2) DC. The mean values were compared using 1-way analysis of variance or paired or unpaired t tests, as appropriate. Simple and multivariable linear regression analyses were used to model the effects of covariates on the outcomes. Results: Patients with International Federation of Gynecology and Obstetrics stage IB to IVA cervical cancer were treated with intracavitary brachytherapy using tandem and ovoid (n=33) or tandem and cylinder (n=4) applicators. The mean CT HR-CTV volume (44.1 cm{sup 3}) was larger than the mean MRI HR-CTV volume (35.1 cm{sup 3}; P<.0001, paired t test). On multivariable analysis, a higher body mass index (BMI) and tumor size ≥5 cm with parametrial invasion on the MRI scan at diagnosis were associated with an increased discrepancy in volume between the HR-CTV contours (P<.02 for both). In addition, the spatial agreement (as measured by DC) between the HR-CTV contours decreased with an increasing BMI (P=.013). Conclusions: We recommend MRI-based brachytherapy planning for patients with tumors >5 cm and parametrial invasion on MRI at diagnosis and for those with a high BMI.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Magnetic Resonance Imaging Appearances in the Postoperative Breast: The Clinical Target Volume-Tumor and Its Relationship to the Chest Wall

Purpose: To describe and measure the postoperative complexes and their relationship to the chest wall in 100 randomly chosen MRI breast scans, to attempt a better understanding of the changes taking place in the postoperative breast. Methods and Materials: Appearances and measurements of MRI postoperative cavities were analyzed in a cohort of 100 randomly selected patients who underwent a single open MRI scan in the conventional breast radiotherapy treatment position before routine two-dimensional simulation. Results: Magnetic resonance imaging appearances of postoperative cavities seem to differ qualitatively from descriptions of CT and ultrasound cavities in the literature. Rather than being principally homogeneous, heterogeneous cavities were seen in 85%, irregular in 51%. The size of cavity was inversely related to the time elapsed since surgery. Cavities directly touched the chest wall in 53% of cases; 89% lay within 10 mm of the chest wall. Regular, annular concentric rings of differing signal were seen in 32% of cases; such appearances have not been previously described. These patterns suggest that seromas may not shrink entirely as a result of simple serous fluid absorption; instead, new tissue may be being laid down. Because large, regular spheroidal/ellipsoidal cavities with crisp margins may be seromas under pressure, greater target shifts during radiation may need to be anticipated in such cases. Conclusions: Postsurgical cavities in the conserved breast on MRI are commonly heterogeneous, irregular, and lie close to the chest wall. Magnetic resonance imaging studies may help in better understanding the natural history of postoperative cavities.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Broadband, large-area microwave antenna for optically detected magnetic resonance of nitrogen-vacancy centers in diamond

We report on a microwave planar ring antenna specifically designed for optically detected magnetic resonance (ODMR) of nitrogen-vacancy (NV) centers in diamond. It has the resonance frequency at around 2.87 GHz with the bandwidth of 400 MHz, ensuring that ODMR can be observed under external magnetic fields up to 100 G without the need of adjustment of the resonance frequency. It is also spatially uniform within the 1-mm-diameter center hole, enabling the magnetic-field imaging in the wide spatial range. These features facilitate the experiments on quantum sensing and imaging using NV centers at room temperature.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigation of laser polarized xenon magnetic resonance

Ground-based investigations of a new biomedical diagnostic technology: nuclear magnetic resonance of laser polarized noble gas are addressed. The specific research tasks discussed are: (1) Development of a large-scale noble gas polarization system; (2) biomedical investigations using laser polarized noble gas in conventional (high magnetic field) NMR systems; and (3) the development and application of a low magnetic field system for laser polarized noble gas NMR.

Walsworth, Ronald L.↗

Hyperintensity in the Dentate Nucleus on Nonenhanced T1-Weighted Magnetic Resonance Imaging Suggests Dechelation of Contrast Agents

With the exception of renal failure patients, gadolinium-based contrast agents (GBCAs) for magnetic resonance imaging (MRI) have a high tolerance and acceptability in patients needing to undergo an enhanced MRI. Now that enhanced MRIs are becoming increasingly popular and nephrogenic systemic fibrosis cases are becoming a rarity, a common belief is that these GBCAs are essentially “biologically inert” materials. However, recent reports have emerged querying the link between these GBCAs and hyperintensity in the dentate nucleus on unenhanced T1-weighted MRI in some patients. This review article outlines the basic chemistry and characteristics of currently approved GBCAs, summarizes the described research findings of gadolinium deposition in the dentate nucleus, and identifies areas for future research.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Nuclear magnetic resonance study of Li and H diffusion in the high-temperature solid phase of LiBH{sub 4}

In order to study the atomic jump motions in the high-temperature solid phase of LiBH{sub 4}, we have measured the {sup 1}H and {sup 11}B nuclear magnetic resonance (NMR) spectra and the {sup 1}H, {sup 7}Li and {sup 11}B spin-lattice relaxation rates in this compound over the resonance frequency range of 14-34.4 MHz. In the temperature range 384-500 K, all the spin-lattice relaxation data are satisfactorily described in terms of a thermally activated jump motion of Li ions with the pre-exponential factor tau{sub 0}=1.1x10{sup -15} s and the activation energy E{sub a}=0.56 eV. The observed frequency dependences of the spin-lattice relaxation rates in this temperature range exclude a presence of any distributions of the Li jump rate or any other jump processes on the frequency scale of 10{sup 7}-10{sup 10} s{sup -1}. The strong narrowing of the {sup 1}H and {sup 11}B NMR lines above 440 K is consistent with the onset of diffusive motion of the BH{sub 4} tetrahedra. - Graphical abstract: The measured spin-lattice relaxation rates of {sup 1}H (a), {sup 7}Li (b) and {sup 11}B (c) as functions of the inverse temperature for the high-temperature solid phase of LiBH{sub 4}. The curves show the simultaneous Bloembergen-Purcell-Pound fits to the data with the fixed parameters of Li diffusion (the pre-exponential factor tau{sub 0}=1.1x10{sup -15} s and the activation energy E{sub a}=0.56 eV). This plot indicates that all the relaxation data for different nuclei and at different resonance frequencies are governed by a single Li jump process. Display Omitted

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Role of the edge stochastic layer in density pump-out by resonant magnetic perturbations

The role of the edge stochastic layer on particle transport is addressed in DIII-D plasmas with applied resonant magnetic perturbations (RMPs) causing density pump-out (a term used to denote the density reduction at the top of the pedestal due to the applied RMPs). Using an analytical model that adds the stochastic parallel transport of electrons (Harvey et al 1981 Phys. Rev. Lett. 47 102) to the fluid equations, the ambipolar radial electric field and particle flux are calculated simultaneously. In this model the nonambipolar electron particle flux, driven by the stochastic magnetic field, is predominantly balanced by the nonambipolar perpendicular ion flux, driven by toroidal viscosity, across a narrow stochastic layer of order two percent of the plasma radius (0.98 < ψn < 1). The model reproduces the level of density pump-out and its dependence on RMP amplitude near the separatrix for three plasma discharges for which the pedestal foot is at medium to high collisionality $(2\leqslant {\nu }_{\text{sep}}^{\ast }\leqslant 30)$. In this work, the experimentally observed and numerically tested inverse density dependence of density pump-out (Hu et al 2020 Nucl. Fusion 60 076001) is accurately captured by the model: an increase in collisionality with density in the pedestal foot results in a decrease in stochastic diffusivity, and hence a decrease in the level of pump-out.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Molecular weight distributions of irradiated siloxane-based elastomers: A complementary study by statistical modeling and multiple quantum nuclear magnetic resonance

The statistical methodology of population balance (PB) has been applied in order to predict the effects of cross-linking and chain-scissioning induced by ionizing radiation on the distribution of molecular weight between cross-links (MWBC) of a siloxane-based elastomer. Effective molecular weight distributions were extracted from the quantification of residual dipolar couplings via multiple quantum nuclear magnetic resonance (MQ-NMR) measurements and are taken to reflect actual MWBC distributions. The PB methodology is then applied to the unirradiated MWBC distribution and considers both chain-scissioning and the possibility of the formation of three types of cross-links: random recombination of scissioned-chain ends (end-linking), random covalent bonds of free radicals on scissioned-chain ends (Y-cross-linking), and the formation of random cross-links from free radicals on side groups (H-cross-linking). The qualitative agreement between the statistical modeling approach and the NMR data confirms that it is possible to predict trends for the evolution of the distribution of MWBC of polymers under irradiation. The approach described herein can also discern heterogeneities in radiation effects in different structural motifs in the polymer network.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Pelvic Lymph Node Topography for Radiotherapy Treatment Planning From Ferumoxtran-10 Contrast-Enhanced Magnetic Resonance Imaging

Purpose: To define a population-based pelvic lymph node clinical target volume (CTV) for radiotherapy treatment planning using magnetic resonance (MR) imaging and the ultrasmall superparamagnetic iron oxide lymph node contrast agent ferumoxtran-10. Methods and Materials: A total of 55 eligible patients with endometrial, cervical, prostate, or bladder cancer underwent MR imaging sessions before and after contrast administration on 2 consecutive days. Ferumoxtran-10 was administered immediately after the first scan. The three-dimensional spatial distribution of the pelvic lymph nodes was determined in relation to adjacent vessels and other musculoskeletal landmarks, from which guidelines for determining a nodal CTV in individual patients were developed. Results: On average, 30 lymph nodes (range, five to 62 nodes) were identified in each patient. The distribution of nodal distances to the closest artery or vein was observed to vary in different anatomic regions. Symmetrical three-dimensional margins of expansion around the distal para-aortic (12 mm), common iliac (10 mm), external iliac (9 mm), and internal iliac (10 mm) vessels, drawn in continuity with a 12-mm expansion anterior to the sacrum and a 22-mm expansion medial to the pelvic sidewall, were shown to encompass the majority of detectable lymph nodes in most patients. Conclusion: Use of MR lymphography with ferumoxtran-10 provides an objective description of lymph node locations for radiotherapy planning. Use of this nodal CTV model in clinical practice could ensure a high probability of encompassing the regions at risk of harboring metastatic disease while minimizing the dose to adjacent normal tissues.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Treatment of Locally Advanced Vaginal Cancer With Radiochemotherapy and Magnetic Resonance Image-Guided Adaptive Brachytherapy: Dose-Volume Parameters and First Clinical Results

Purpose: To investigate the clinical feasibility of magnetic resonance image-guided adaptive brachytherapy (IGABT) for patients with locally advanced vaginal cancer and to report treatment outcomes. Methods and Materials: Thirteen patients with vaginal cancer were treated with external beam radiotherapy (45-50.4 Gy) plus IGABT with or without chemotherapy. Distribution of International Federation of Gynecology and Obstetrics stages among patients were as follows: 4 patients had Stage II cancer, 5 patients had Stage III cancer, and 4 patients had Stage IV cancer. The concept of IGABT as developed for cervix cancer was transferred and adapted for vaginal cancer, with corresponding treatment planning and reporting. Doses were converted to the equivalent dose in 2 Gy, applying the linear quadratic model ({alpha}/{beta} = 10 Gy for tumor; {alpha}/{beta} = 3 for organs at risk). Endpoints studied were gross tumor volume (GTV), dose-volume parameters for high-risk clinical target volume (HRCTV), and organs at risk, local control (LC), adverse side effects, and survival. Results: The mean GTV ({+-} 1 standard deviation) at diagnosis was 45.3 ({+-}30) cm{sup 3}, and the mean GTV at brachytherapy was 10 ({+-}14) cm{sup 3}. The mean D90 for the HRCTV was 86 ({+-}13) Gy. The mean D2cc for bladder, urethra, rectum, and sigmoid colon were 80 ({+-}20) Gy, 76 ({+-}16) Gy, 70 ({+-}9) Gy, and 60 ({+-}9) Gy, respectively. After a median follow-up of 43 months (range, 19-87 months), one local recurrence and two distant metastases cases were observed. Actuarial LC and overall survival rates at 3 years were 92% and 85%. One patient with Stage IVA and 1 patient with Stage III disease experienced fistulas (one vesicovaginal, one rectovaginal), and 1 patient developed periurethral necrosis. Conclusions: The concept of IGABT, originally developed for treating cervix cancer, appears to be applicable to vaginal cancer treatment with only minor adaptations. Dose-volume parameters for HRCTV and organs at risk are in a comparable range. First clinical results indicate excellent LC. Further prospective multicenter studies are needed to establish this method and to confirm these results.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Wide Operational Windows of Edge-Localized Mode Suppression by Resonant Magnetic Perturbations in the DIII-D Tokamak

Edge-Localized-Mode (ELM) suppression by resonant magnetic perturbations (RMPs) generally occurs over very narrow ranges of the plasma current (or magnetic safety factor $q_{95}$) in the DIII-D tokamak. However, wide $q_{95}$ ranges of ELM suppression are needed for the safety and operational flexibility of ITER and future reactors. In DIII-D ITER Similar Shape (ISS) plasmas with $n$=3 RMPs, the range of $q_{95}$ for ELM suppression is found to increase with decreasing electron density. Nonlinear two-fluid MHD simulations reproduce the observed $q_{95}$ windows of ELM suppression and the dependence on plasma density, based on the conditions for resonant field penetration at the top of the pedestal. When the RMP amplitude is close to the threshold for resonant field penetration, only narrow isolated magnetic islands form near the top of the pedestal, leading to narrow $q_{95}$ windows of ELM suppression. However, as the threshold for field penetration decreases with decreasing density, resonant field penetration can take place over a wider range of $q_{95}$. For sufficiently low density (penetration threshold) multiple magnetic islands form near the top of the pedestal giving rise to continuous $q_{95}$ windows of ELM suppression. The model predicts that wide $q_{95}$ windows of ELM suppression can be achieved at substantially higher pedestal pressure in DIII-D by shifting to higher toroidal mode number ($n$=4) RMPs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effects of resonant magnetic perturbations on radial electric fields in DIII-D tokamak

Here, gyrokinetic simulations of DIII-D tokamak equilibrium find that resonant magnetic perturbation (RMP) drives a neoclassical non-ambipolar electron particle flux, which causes a rapid change of equilibrium radial electric fields consistent with experimental observations during the suppression of the edge localized mode (ELM). The simulation results provide a support for the conjecture that RMP-induced changes of radial electric fields lead to the enhanced turbulent transport at the pedestal top during the ELM suppression (Taimourzadeh et al 2019 Nucl. Fusion 59 046005). Furthermore, gyrokinetic simulations of collisionless damping of zonal flows show that resonant responses to the RMP decrease the residual level of the zonal flows and damp the geodesic acoustic mode.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

RASER MRI: Magnetic resonance images formed spontaneously exploiting cooperative nonlinear interaction

The spatial resolution of magnetic resonance imaging (MRI) is limited by the width of Lorentzian point spread functions associated with the transverse relaxation rate 1/T 2 * . Here, we show a different contrast mechanism in MRI by establishing RASER (radio-frequency amplification by stimulated emission of radiation) in imaged media. RASER imaging bursts emerge out of noise and without applying radio-frequency pulses when placing spins with sufficient population inversion in a weak magnetic field gradient. Small local differences in initial population inversion density can create stronger image contrast than conventional MRI. This different contrast mechanism is based on the cooperative nonlinear interaction between all slices. On the other hand, the cooperative nonlinear interaction gives rise to imaging artifacts, such as amplitude distortions and side lobes outside of the imaging domain. Contrast mechanism and artifacts are explored experimentally and predicted by simulations on the basis of a proposed RASER MRI theory.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗