Search NASA⌕ Search

SEARCH · Search NASA

Results for “MEASURING INSTRUMENTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Experimental Report: Multi-Instrument Comparison of AAF Size Distribution Instruments

Aerosols are particles suspended in the atmosphere, ranging in size from nanometers to micrometers. Their size distribution affects key atmospheric processes, including nucleation, coagulation, scavenging, activation, and radiative properties (Seinfeld and Pandis 2016). Aerosol size distribution is a critical parameter in atmospheric science, influencing processes such as cloud formation and radiative forcing. Accurate representation of aerosol size distributions is essential for understanding their impact on climate, air quality, and human health. However, aerosol size and composition vary significantly across time and space due to meteorological conditions and natural or anthropogenic sources. (Wu and Boor 2021). Various instruments are used to measure aerosol size distributions, each with distinct principles, advantages, and limitations. This report begins with an in-depth overview of aerosol size-distribution comparison studies, focusing on the passive cavity aerosol spectrometer probe (PCASP), portable optical particle spectrometer (POPS), ultra-high-sensitivity aerosol spectrometer (UHSAS), aerodynamic particle sizer (APS), and scanning mobility particle sizer (SMPS). All of these instruments are used by the U.S. Department of Energy Atmospheric Radiation Measurement (ARM) Aerial Facility (AAF), which commissioned this comparison and report. The report evaluates the strengths and weaknesses of these instruments, highlights their applications, and discusses efforts to merge data from multiple instruments for comprehensive analysis.

54 ENVIRONMENTAL SCIENCES↗

Assessment of Different Approaches for Measuring Shear Fracture Appearance in Charpy Tests

In this work, different approaches for establishing shear fracture appearance (SFA) on tested Charpy specimens were assessed and compared, namely (in order of increasing expected accuracy) estimates based on characteristic forces from instrumented Charpy tests, optical measurements using image analysis software, and measurements performed with the aid of a scanning electron microscope. Comparisons between different SFA values for 129 instrumented Charpy tests currently included in the National Institute of Standards and Technology database allowed us to establish the relationships between the different available approaches and formulate recommendations for the revision of the standards ASTM E2298-18, Standard Test Method for Instrumented Impact Testing of Metallic Materials, and ISO 14556:2015, Metallic Materials — Charpy V-Notch Pendulum Impact Test — Instrumented Test Method, which currently provide four empirical correlations that can be used to estimate SFA.

36 MATERIALS SCIENCE↗

Atmospheric Observation System for Greenhouse Gases (GHG) Instrument Handbook

The Greenhouse Gas (GhG) Measurement system is a combination of two systems in series: (1) the Tower Gas Processing (TGP) System, an instrument rack which pulls, pressurizes, and dries air streams from an atmospheric sampling tower through a series of control and monitoring components, and (2) the Picarro model G2301 cavity ringdown spectrometer (CRDS), which measures CO2, CH4, and H2O vapor; the primary measurements of the GhG system.

54 ENVIRONMENTAL SCIENCES↗

Feasibility of using thermal response methods for nonintrusive compressed air flow measurement

Robust, low-cost nonintrusive flow meters are of interest in many industries. Particularly, a reliable nonintrusive flow measurement for the diagnosis of air leaks in compressed air systems is desirable. Measurement of the air flow due to leaks in the system ensures an accurate estimation of potential cost and energy savings. This study evaluates a novel method of using thermal responses to nonintrusively measure leakage rates in compressed air lines. The method uses heat and the resulting thermal response to calculate the flow rate inside the compressed air line. Compared to the current methods for flow measurement, this method can simplify flow measurement while decreasing the sensitivity to errors when measuring flow rates. In this study, the methodology of the proposed method is explained along with the potential advantages to the design. Two approaches are evaluated: a dynamic step response and sinusoidal frequency response. Simulated tests evaluate the feasibility of the proposed methods, followed by experiments that validate the simulation results. A clear correlation between the thermal step response and the flow rate indicate viability of the proposed method in simulation. Experimental results yielded similar results, confirming the validity of the proposed method. The results of a field test in an industrial environment demonstrate the capability of the approach to other flow rate measurement techniques.

42 ENGINEERING↗

Enhancement of EM Pump Performance through Modeling and Testing

Liquid sodium has seen development as a nuclear reactor coolant in the United States for over 50 years. While sodium has many desirable characteristics as a heat transfer fluid, its reactivity poses numerous engineering challenges for even the most basic plant components like pumps. Despite the challenges, mechanical pumps have seen success in sodium service albeit at the expense of simplicity and flexibility. In fact, significant failures of these pumps have been recorded which can be attributed to their complexity. Notwithstanding the complexity, mechanical pumps are still widely proposed for the main circuit pump of sodium cooled reactors. However, an alternative to mechanical pumps are Electromagnetic Induction Pumps (EMIPs) which use the principle of the Lorentz Force. EMIPs avoid mechanically moving parts in contact with sodium which simplifies the design by avoiding mechanical wear and seals. Therefore, these pumps are generally safer and more reliable than their mechanical counterparts. That being said, EMIPs suffer from relatively low efficiencies that range from 5% to 45%. Some of the inefficiencies are inherent to the EMIPs pumps; namely, inefficiencies arise in the form of resistive heating losses in the fluid itself. However, other inefficiencies arise from Edge Effects which include Finite Length and Finite Width effects. Due to the significant safety advantages EMIPs have compared to mechanical pumps, there is a strong motivation to integrate these technologies into the design of Generation IV liquid-metal-cooled nuclear power plants. However, EMIPs have low efficiencies partly attributed to Edge Effects. Much of the literature focusing on Edge Effects is dated or simply does not exist in the public domain. More recently, numerical models of EMIPs have shown promising results. However, these models are often custom solvers or use complex software suits which limit their application. This report describes the work completed to understand Edge Effects in two EMIPs designs. These designs are the Annular Linear Induction Pump (ALIP) and Permanent Magnet Induction Pump (PMIP) also known as a Moving Magnet Pump (MMP). The methodology developed during this project aim at measuring key performance parameters (pressure-flowrate and efficiency-slip performance) using high temperature liquid-sodium. Baseline experimental measurements were then used to verify the accuracy of numerical models developed in the software suit ANSYS/FLUENT. On the experimental side, instrumentation was developed to characterize the pressure-flowrate and efficiency-slip performance of both the ALIP and PMIP in high-temperature liquid-sodium. Additionally, instrumentation was developed to measure potential output pressure pulsations and the magnetic field distributions. Moreover, a specialized ALIP was constructed to study the impacts magnetic field tapering, also known as coil grading, on the Finite Length Effect. Lastly, experimental performance curves of the PMIP were collected at 300 oC and 600 oC and compared to analytical theory which accounted for Finite Width Effects. These results showed that the Finite Width Effect and non-uniform magnetic field in a PMIP impact the performance. On the numerical side, models were developed using the software suit FLUENT/ANSYS. These methods were initially compared against a simple MHD flow in a Permanent Magnet Electromagnet Flowmeter (PMEMFM). The results were significant in that they showed agreeance between the numerical model and demonstrated that PMEMFM’s could be calibrated numerically. These modeling methods were then applied to a prototypic PMIP. Results showed that this simple model provided reasonably accurate results of the PMIP p-Q performance.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Fluorescent bioaerosol particle concentrations measured by the DU WIBS during the AGINSGP field experiment

Real-time, immersion mode ambient fluorescent bioaerosol concentrations were measured at ARM’s Southern Great Plains (SGP) site during the AGINSGP field experiment using a Wideband Integrated Bioaerosol Sensor (DMT Inc.; WIBS-4A). The WIBS-4A is an optical particle counter that also measures single particle fluorescence in three channels, along with particle asymmetry. Particles are grouped into different types depending on which channels they fluoresce in. The instrument was located in the guest instrument facility (GIF) and measured fluorescent particle concentrations from April 7th to April 29th. Data presented here are the concentrations for each particle type, binned in 5 minute increments. Air was drawn into the GIF through custom aluminum stack inlets (6” inner diameter) attached vertically to the outer GIF wall and the GIF outside platform. A blower pulled air through the stacks at a velocity of 1 m/s. Aerosol instruments subsampled via wall ports, through either 3/8” or 1/4" copper lines, depending on sample flow of the instrument. Particles were dried using a silica diffusion dryer prior to analysis.

54 ENVIRONMENTAL SCIENCES↗

Measurements and Characterization

The Measurements and Characterization scientists at the National Renewable Energy Laboratory provide characterization support, conduct collaborative research, and develop new measurement capabilities and diagnostics to advance the photovoltaic (PV) generation of energy. We use state-of- the-art characterization tools to solve problems in all phases of material and device development. Results lead to an increased understanding that drives advances in the performance, reliability, cost, and manufacturability of PV materials, devices, and systems.

14 SOLAR ENERGY↗

Cosmological constraints from a joint DESI DR1 Full-Shape and DR2 BAO

We present a cosmological analysis combining full-shape (FS) clustering measurements from the Dark Energy Spectroscopic Instrument (DESI) DR1 with baryon acoustic oscillation (BAO) measurements from DESI DR2. To achieve a robust combination that accounts for the correlation between the two data releases, we employ the ShapeFit compression method and estimate the joint covariance using EZmocks. This compressed approach inherently mitigates the prior volume effects that have previously dominated Bayesian constraints from DESI data with minimal external priors. Consequently, we obtain — for the first time within a Bayesian framework — reliable DESI-only constraints on extensions to ΛCDM using only a Big Bang Nucleosynthesis prior on the baryon density and a wide prior on the spectral index. In flat ΛCDM, we find Ω m = 0.3035 ± 0.0085, h = 0.6876 ± 0.0059, and σ 8 = 0.822 ± 0.034. For the w 0 w a CDM dynamical dark energy model, we measure w 0 = -0.49 ± 0.25 and w a = -1.52 ± 0.77, improving constraints by ∼ 30% relative to the analogous DR1 measurement and reducing the discrepancy with ΛCDM to 1.4σ when compared to BAO only analyses. We also report competitive limits on the sum of neutrino masses and spatial curvature. This work demonstrates that the ShapeFit compression provides a prior-robust and computationally efficient pathway to constrain beyond-ΛCDM physics with large-scale structure.

baryon acoustic oscillations↗

Locating Partial Discharges in Power Transformers with Convolutional Iterative Filtering

The most common source of transformer failure is in the insulation, and the most prevalent warning signal for insulation weakness is partial discharge (PD). Locating the positions of these partial discharges would help repair the transformer to prevent failures. This work investigates algorithms that could be deployed to locate the position of a PD event using data from ultra-high frequency (UHF) sensors inside the transformer. These algorithms typically proceed in two steps: first determining the signal arrival time, and then locating the position based on time differences. This paper reviews available methods for each task and then propose new algorithms: a convolutional iterative filter with thresholding (CIFT) to determine the signal arrival time and a reference table of travel times to resolve the source location. The effectiveness of these algorithms are tested with a set of laboratory-triggered PD events and two sets of simulated PD events inside transformers in production use. Tests show the new approach provides more accurate locations than the best-known data analysis algorithms, and the difference is particularly large, 3.7X, when the signal sources are far from sensors.

47 OTHER INSTRUMENTATION↗

Sensitivity and Importance Measure Analyses for Various Design Architectures for High Safety-Significant Safety-Related Digital Instrumentation and Control Systems of Nuclear Power Plants

A transition from analog instrumentation and control (I&C) technologies to digital I&C technologies is taking place for license renewals of existing nuclear power plants and for operating licenses of new advanced reactors. This transition necessitates research on risk and economic assessments of digital I&C technologies to ensure the long-term safety and reliability of vital systems, reduce uncertainty in licensing costs in addition to timeline, support integration of digital I&C systems in the plant, and find the most efficient technology upgrades. Adding redundancy within systems or components is a common means of improving design safety; however, it can also make designs more prone to common-cause failures (CCFs). Introducing diversity into redundant systems or components is a way to mitigate and possibly eliminate CCFs, but it also increases plant complexity and may be costly. The balance between redundancy and diversity remains a challenge for digital I&C systems. This study performs sensitivity and importance analyses for four design architectures of two digital I&C systems—the reactor-trip system and the engineered safety features actuation system. For each system, two architectures are examined, including a redundant, non-diverse configuration and a redundant, diverse configuration. The sensitivity analysis will provide insights on the impact of introducing diversity to system reliability. The importance results will help identify risk-significant and risk-sensitive components and failure modes, which may be good candidates for future design improvement.

99 GENERAL AND MISCELLANEOUS↗

Unattended Single Channel Analyzer (USCA) FY20 Summary Report

In FY20 LANL was funded to design, fabricate, test and document an instrument that can be used by the IAEA for gamma ray measurements in scintillator applications. This instrument, the Unattended Single Channel Analyzer (USCA), will be part of the family of IAEA unattended instruments and completes the suite of most used data acquisition needs provided by the previously designed UNAP instrument. The USCA is designed to meet all the same IAEA requirements designed into the UMSR and UDCM. The new instrument has the same look and feel making it simple for agency staff to move between instruments. This project taps into all the design functions developed during the UMSR and UDCM development. Along with the design and fabrication of a USCA, this project included production of a prototype for IAEA testing and a complete set of documentation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗